Debopoma Kar Ray
Research Subjects
Debopoma Kar Ray has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Surajit Chattopadhyay
Department of Electrical Engineering, Ghani Khan Choudhury Institute of Engineering and Technology, Malda, West Bengal, India
8 shared publications - Tamal Roy
Department of Electrical Engineering, MCKV Institute of Engineering, Liluah, Howrah, India
4 shared publications Abhishek Mishra
Electrical Engineering Department, MCKV Institute of Engineering, Howrah, India
1 shared publicationAnisha Rai
Electrical Engineering Department, MCKV Institute of Engineering, Howrah, India
1 shared publicationAnkit Kumar Khetan
Electrical Engineering Department, MCKV Institute of Engineering, Howrah, India
1 shared publicationDebarati Das
MCKV Institute of Engineering
1 shared publication
Latest Publications
- 13 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 39 (1) , 107-115
Skewness Driven DFIG's DC Link Bus Short and Open Circuit Faults Diagnosis Using Rotor and Stator Currents
DC link bus plays an important role in the operation of doubly fed induction generators (DFIG) and sustainable power generation. It is used in the converter section connected between the rotor side converter (RSC) and stator side converter (SSC). Here a Skewness-driven deep learning method has been proposed for DFIG's DC link bus fault diagnosis using rotor current as well as stator current. Study shows that harmonics in both rotor and stator currents are influenced by faults. Stator and rotor current signature Wavelet decomposition-based Skewness-driven statistical scanning has been made to disintegrate normal, short circuit, and open circuit fault conditions incorporating an artificial neural network (ANN) based algorithm. The method has been first applied in a simulated environment and then testified in real fault conditions. The results obtained are satisfactory for effective fault identification from the rotor as well as from the stator sides.
- 13 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 39 (1) , 107-115
Skewness Driven DFIG's DC Link Bus Short and Open Circuit Faults Diagnosis Using Rotor and Stator Currents
DC link bus plays an important role in the operation of doubly fed induction generators (DFIG) and sustainable power generation. It is used in the converter section connected between the rotor side converter (RSC) and stator side converter (SSC). Here a Skewness-driven deep learning method has been proposed for DFIG's DC link bus fault diagnosis using rotor current as well as stator current. Study shows that harmonics in both rotor and stator currents are influenced by faults. Stator and rotor current signature Wavelet decomposition-based Skewness-driven statistical scanning has been made to disintegrate normal, short circuit, and open circuit fault conditions incorporating an artificial neural network (ANN) based algorithm. The method has been first applied in a simulated environment and then testified in real fault conditions. The results obtained are satisfactory for effective fault identification from the rotor as well as from the stator sides.
- 1 January 2022
- Published by Springer Nature
- p. 569-578
Potential Energy-Driven Stability Analysis of Tie Lines in Ring Network
- 1 January 2022
- Published by Springer Nature
- p. 569-578
Potential Energy-Driven Stability Analysis of Tie Lines in Ring Network
- Open Access
- 30 March 2021
- Published by Institution of Engineering and Technology (IET) in IET Nanodielectrics
- Vol. 4 (3) , 121-129
Switching transient‐based state of Ampere‐hour prediction of lithium‐ion, nickel‐cadmium, nickel‐metal‐hydride and lead acid batteries used in vehicles
The state of the ampere‐hour capacity of the battery depends on the condition of materials used in it. Large reduction of capacity ends with maintenance or replacement of the battery. Modern battery materials include application of nanomaterials and nanotechnology in various stages of production. This article attempts to monitor the capacity of battery used for vehicles which are made of different types of materials using switching transients. The analytical part was done using wavelet‐based decompositions. Data sets of large number of coefficients have been developed for learning. Their statistical behaviour has been studied, and monitoring was initially carried out by some selective parameters. Then the artificial neural network‐based algorithm was developed which includes all features of statistical variation for better monitoring. Case studies have been carried out followed by comparison. The study ends with a satisfactory monitoring.
- 30 March 2021
- Published by Institution of Engineering and Technology (IET) in IET Nanodielectrics
- Vol. 4 (3) , 121-129
Open AccessSwitching transient‐based state of Ampere‐hour prediction of lithium‐ion, nickel‐cadmium, nickel‐metal‐hydride and lead acid batteries used in vehicles
The state of the ampere‐hour capacity of the battery depends on the condition of materials used in it. Large reduction of capacity ends with maintenance or replacement of the battery. Modern battery materials include application of nanomaterials and nanotechnology in various stages of production. This article attempts to monitor the capacity of battery used for vehicles which are made of different types of materials using switching transients. The analytical part was done using wavelet‐based decompositions. Data sets of large number of coefficients have been developed for learning. Their statistical behaviour has been studied, and monitoring was initially carried out by some selective parameters. Then the artificial neural network‐based algorithm was developed which includes all features of statistical variation for better monitoring. Case studies have been carried out followed by comparison. The study ends with a satisfactory monitoring.
- 17 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (5) , 6952-6961
Skewness Scanning for Diagnosis of a Small Inter-Turn Fault in Quadcopter’s Motor Based on Motor Current Signature Analysis
This paper deals with hall sensor based very small inter-turn short circuit fault assessment of singlephase quadcopter system using current signature analysis of connected brushless DC motors at the transient condition. Firstly, a quadcopter has been modeled with a proportionaldifferential controller, and roll, pitch, and yaw angles have been adjusted as reference inputs. Secondly, the current signal of each motor has been captured through a hall sensor for monitoring at various conditions. Then, Skewness scanning is performed on multi-resolution analysis based wavelet coefficients obtained from the starting transients. Variation in the asymmetrical distribution of coefficients has been observed at different decomposition levels. Levels that show almost linear variation with the increase of fault are selected for fault detection. An algorithm of Skewness scanning has been proposed for the detection of the number of shorted turns present in the system. Practical validation of the work has been done with data captured by the data acquisition system through the Hall probe; satisfactory diagnosis has been observed in experimentation.
- 17 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (5) , 6952-6961
Skewness Scanning for Diagnosis of a Small Inter-Turn Fault in Quadcopter’s Motor Based on Motor Current Signature Analysis
This paper deals with hall sensor based very small inter-turn short circuit fault assessment of singlephase quadcopter system using current signature analysis of connected brushless DC motors at the transient condition. Firstly, a quadcopter has been modeled with a proportionaldifferential controller, and roll, pitch, and yaw angles have been adjusted as reference inputs. Secondly, the current signal of each motor has been captured through a hall sensor for monitoring at various conditions. Then, Skewness scanning is performed on multi-resolution analysis based wavelet coefficients obtained from the starting transients. Variation in the asymmetrical distribution of coefficients has been observed at different decomposition levels. Levels that show almost linear variation with the increase of fault are selected for fault detection. An algorithm of Skewness scanning has been proposed for the detection of the number of shorted turns present in the system. Practical validation of the work has been done with data captured by the data acquisition system through the Hall probe; satisfactory diagnosis has been observed in experimentation.
- 20 September 2020
- Published by Springer Nature
- p. 281-294
Condition Monitoring of PV-Wind System Using Stockwell Transform
- 20 September 2020
- Published by Springer Nature
- p. 281-294
Condition Monitoring of PV-Wind System Using Stockwell Transform
- Open Access
- 1 August 2020
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 14 (6) , 639-650
Fault analysis in solar–wind microgrid using multi‐resolution analysis and Stockwell transform‐based statistical analysis
This study deals with the unsymmetrical fault assessment in a solar–wind hybrid microgrid, analysing the grid current signature, multi‐resolution analysis of discrete wavelet transform and Stockwell transform coefficient's statistical analysis‐based best‐fit solution. The recorded grid current at normal and unsymmetrical faults is analysed using these techniques and an algorithm has been developed for effective fault analysis in the grid. Practical validation of the work has been done with the data obtained from the field study and percentage deviations of the optimised results from theoretical calculations have been evaluated. Comparative study of the proposed technique is done with the data collected from the industry to authenticate the effectiveness of the approach.
- 1 August 2020
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 14 (6) , 639-650
Open AccessFault analysis in solar–wind microgrid using multi‐resolution analysis and Stockwell transform‐based statistical analysis
This study deals with the unsymmetrical fault assessment in a solar–wind hybrid microgrid, analysing the grid current signature, multi‐resolution analysis of discrete wavelet transform and Stockwell transform coefficient's statistical analysis‐based best‐fit solution. The recorded grid current at normal and unsymmetrical faults is analysed using these techniques and an algorithm has been developed for effective fault analysis in the grid. Practical validation of the work has been done with the data obtained from the field study and percentage deviations of the optimised results from theoretical calculations have been evaluated. Comparative study of the proposed technique is done with the data collected from the industry to authenticate the effectiveness of the approach.
- 11 July 2020
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 101 (4) , 335-345
Brush Fault Analysis for Indian DC Traction Locomotive Using DWT-Based Multi-resolution Analysis
- 11 July 2020
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 101 (4) , 335-345
Brush Fault Analysis for Indian DC Traction Locomotive Using DWT-Based Multi-resolution Analysis
- 25 October 2018
- Published by Springer Nature
- p. 57-71
Fault Diagnosis in Isolated Renewable Energy Conversion System Using Skewness and Kurtosis Assessment
- 25 October 2018
- Published by Springer Nature
- p. 57-71
Fault Diagnosis in Isolated Renewable Energy Conversion System Using Skewness and Kurtosis Assessment
- 6 August 2018
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 66 (4) , 491-504
Multi-Resolution-Analysis-based Line-to-Ground Fault Detection in a VSC-Based HVDC System
This paper deals with the identification of single line-to-ground (LG) fault in a voltage source controller based high voltage direct current (HVDC) link, monitoring the multi-resolution-analysis (MRA)-based discrete wavelet transform (DWT) coefficients. A prototype model has been developed to assess the system at normal and at LG fault at the receiving end of the HVDC link, monitoring the AC sending end current in the system. This study also deals with the assessment of locations of LG faults in the HVDC link at different positions, from the sending end. Case studies have been carried out using field data and different DWT-based statistical parameters have been estimated and their variations due to fault have been observed. Then DWT-level-based optimization and parametric optimization have been done. An algorithm has been developed for fault assessment. Based on the specific outcome of the case studies, distance relaying scheme has been proposed, which has been validated with software simulation based on real field data.
- 6 August 2018
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 66 (4) , 491-504
Multi-Resolution-Analysis-based Line-to-Ground Fault Detection in a VSC-Based HVDC System
This paper deals with the identification of single line-to-ground (LG) fault in a voltage source controller based high voltage direct current (HVDC) link, monitoring the multi-resolution-analysis (MRA)-based discrete wavelet transform (DWT) coefficients. A prototype model has been developed to assess the system at normal and at LG fault at the receiving end of the HVDC link, monitoring the AC sending end current in the system. This study also deals with the assessment of locations of LG faults in the HVDC link at different positions, from the sending end. Case studies have been carried out using field data and different DWT-based statistical parameters have been estimated and their variations due to fault have been observed. Then DWT-level-based optimization and parametric optimization have been done. An algorithm has been developed for fault assessment. Based on the specific outcome of the case studies, distance relaying scheme has been proposed, which has been validated with software simulation based on real field data.