Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Benjamin Ralph has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Compressed Timeline Approach to Residential Corridor Smoke Control Modelling Using Initial Apartment Conditions

    by Charlie Hopkin, Jun Heng Low, Benjamin Ralph, Danny Hopkin

    It is common for fire engineers in the UK to consider a time-dependent series of events when using the Fire Dynamics Simulator to assess the performance of residential corridor smoke control systems. A significant proportion of this established timeline focusses on producing the necessary buildup of smoke and heat in the apartment of origin, prior to any smoke spreading to the corridor or stairs. This paper proposes an alternative approach that enables a compressed modelling timeline by using uniform initial condition parameters in the apartment of origin for the soot mass fraction, room gas temperature, wall and ceiling temperatures, and slab temperature. These conditions can be applied from the outset for separate means of escape and firefighting phases, providing greater flexibility and reducing the wall-clock times for simulations. To achieve this, simulations for a 1000 kW medium growth rate fire in a single reasonable worst-case exemplar arrangement were undertaken using an established timeline approach. This was then used to estimate the approximate initial conditions needed to inform the compressed timeline input parameters. When comparing the established and compressed timeline approaches, close agreement was demonstrated for the estimated conditions of corridor visibility and temperature. The paper also suggests prospective correlations for the initial condition parameters needed to represent a given maximum heat release rate. The paper ultimately provides engineers with a method for residential corridor smoke control modelling that reduces simulation times, as well as providing greater consistency in the demonstrated performance, by proposing initial conditions independent of the dimensions of the apartment.


  • Coupled hybrid modelling within the Fire Dynamics Simulator: transient transport and mass storage

    by Benjamin Ralph, Ricky Carvel, Jason Floyd

    Non-prescriptive design within fire engineering is becoming more prevalent as buildings get taller and more complex. This necessitates the increased use of reliable deterministic predictions, typically computational fluid dynamics-based models. Driven by time constraints, modellers are required to limit the domain to reduce wall time. This ignores the two-way coupling of a fire and a total building system which could embody risk to life. One way to address this risk is the use of coupled hybrid modelling to expand the domain, explicitly quantifying risk-related quantities in the far field whilst maintaining practicable wall times. Fire Dynamics Simulator (FDS) version 5.5 opened the door to coupled hybrid modelling within FDS and introduced the HVAC network submodel. Until FDS version 6.5.3, the submodel did not account for transient transport or mass storage. In this work, a new transient transport and mass storage subroutine has been introduced into HVAC which is available in FDS version 6.5.3 onwards. The relevant conservation equations and numerical solution are described. Successful verification cases are presented for various arrangements to test the implementation of the solution scheme. To demonstrate the benefits of the new method, a fire engineering test case is presented. The test case illustrates the potential risks contained within the pre-existing coupled hybrid modelling method. These risks include unrealistic predictions of hot layer height and head height temperatures and visibility. The test case demonstrates that the new coupled hybrid modelling method address these shortcomings and could form part of a most robust fire safety engineering solution. Based on experimental benchmarking exercises, recommended model correction coefficients are put forward. The new model implementation can be used by designers to quantitatively examine the fire hazard embodied within the two-way coupling of a fire and a total building system.