Aurelie Dehlinger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Aurelie Dehlinger has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Haidl
Institute for X-Optics, University of Applied Sciences Koblenz, Joseph-Rovan-Allee 2, Remagen 53424, Germany
3 shared publications Birgit KanngieBer
Berlin Laboratory for innovative X-ray Technologies (BLiX)' Berlin' Germany
2 shared publicationsChristian Seim
Physikalisch-Technische Bundesanstalt, X-ray Spectrometry, Abbestr. 2-12, 10587 Berlin, Germany
2 shared publications- Hanna Dierks
Institute of Optics and Atomic Physics, Technische Universität Berlin, Hardenbergstraße 36, Berlin 10623, Germany
2 shared publications Holger Stiel
Berlin Laboratory for Innovative X-ray technologies (BLiX), Hardenbergstraße 36, Berlin 10623, Germany
2 shared publications- Konstantin Andrianov
Institute for X-Optics, University of Applied Sciences Koblenz, Joseph-Rovan-Allee 2, Remagen 53424, Germany
2 shared publications
Latest Publications
- 7 October 2020
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 26 (6) , 1124-1132
Laboratory Soft X-Ray Microscopy with an Integrated Visible-Light Microscope—Correlative Workflow for Faster 3D Cell Imaging
Laboratory transmission soft X-ray microscopy (L-TXM) has emerged as a complementary tool to synchrotron-based TXM and high-resolution biomedical 3D imaging in general in recent years. However, two major operational challenges in L-TXM still need to be addressed: a small field of view and a potentially misaligned rotation stage. As it is not possible to alter the magnification during operation, the field of view in L-TXM is usually limited to a few tens of micrometers. This complicates locating areas and objects of interest in the sample. Additionally, if the rotation axis of the sample stage cannot be adjusted prior to the experiments, an efficient workflow for tomographic imaging cannot be established, as refocusing and sample repositioning will become necessary after each recorded projection. Both these limitations have been overcome with the integration of a visible-light microscope (VLM) into the L-TXM system. Here, we describe the calibration procedure of the goniometer sample stage and the integrated VLM and present the resulting 3D imaging of a test sample. In addition, utilizing this newly integrated VLM, the extracellular matrix of cryofixed THP-1 cells (human acute monocytic leukemia cells) was visualized by L-TXM for the first time in the context of an ongoing biomedical research project.
- 7 October 2020
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 26 (6) , 1124-1132
Laboratory Soft X-Ray Microscopy with an Integrated Visible-Light Microscope—Correlative Workflow for Faster 3D Cell Imaging
Laboratory transmission soft X-ray microscopy (L-TXM) has emerged as a complementary tool to synchrotron-based TXM and high-resolution biomedical 3D imaging in general in recent years. However, two major operational challenges in L-TXM still need to be addressed: a small field of view and a potentially misaligned rotation stage. As it is not possible to alter the magnification during operation, the field of view in L-TXM is usually limited to a few tens of micrometers. This complicates locating areas and objects of interest in the sample. Additionally, if the rotation axis of the sample stage cannot be adjusted prior to the experiments, an efficient workflow for tomographic imaging cannot be established, as refocusing and sample repositioning will become necessary after each recorded projection. Both these limitations have been overcome with the integration of a visible-light microscope (VLM) into the L-TXM system. Here, we describe the calibration procedure of the goniometer sample stage and the integrated VLM and present the resulting 3D imaging of a test sample. In addition, utilizing this newly integrated VLM, the extracellular matrix of cryofixed THP-1 cells (human acute monocytic leukemia cells) was visualized by L-TXM for the first time in the context of an ongoing biomedical research project.
- 21 January 2019
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 26 (2) , 430-438
Scanning transmission X-ray microscopy with efficient X-ray fluorescence detection (STXM-XRF) for biomedical applications in the soft and tender energy range
Scanning transmission X-ray microscopy, especially in combination with X-ray fluorescence detection (STXM-XRF) in the soft X-ray energy range, is becoming an increasingly important tool for life sciences. Using X-ray fluorescence detection, the study of biochemical mechanisms becomes accessible. As biological matrices generally have a low fluorescence yield and thus a low fluorescence signal, high detector efficiency (e.g. large solid angle) is indispensable for avoiding long measurement times and radiation damage. Here, the new AnImaX STXM-XRF microscope equipped with a large solid angle of detection enabling fast scans and the first proof-of-principle measurements on biomedical samples are described. In addition, characterization measurements for future quantitative elemental imaging are presented.
- 21 January 2019
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 26 (2) , 430-438
Scanning transmission X-ray microscopy with efficient X-ray fluorescence detection (STXM-XRF) for biomedical applications in the soft and tender energy range
Scanning transmission X-ray microscopy, especially in combination with X-ray fluorescence detection (STXM-XRF) in the soft X-ray energy range, is becoming an increasingly important tool for life sciences. Using X-ray fluorescence detection, the study of biochemical mechanisms becomes accessible. As biological matrices generally have a low fluorescence yield and thus a low fluorescence signal, high detector efficiency (e.g. large solid angle) is indispensable for avoiding long measurement times and radiation damage. Here, the new AnImaX STXM-XRF microscope equipped with a large solid angle of detection enabling fast scans and the first proof-of-principle measurements on biomedical samples are described. In addition, characterization measurements for future quantitative elemental imaging are presented.
- 10 August 2018
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 24 (S2) , 162-163
A Compact Vibration Reduced Set-up for Scanning nm-XRF and STXM.
- 10 August 2018
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 24 (S2) , 162-163
A Compact Vibration Reduced Set-up for Scanning nm-XRF and STXM.
- 10 August 2018
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 24 (S2) , 250-251
Towards High Performance Soft X-ray Cryo-Tomography in the Laboratory
- 10 August 2018
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 24 (S2) , 250-251
Towards High Performance Soft X-ray Cryo-Tomography in the Laboratory
- 10 August 2018
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 24 (S2) , 230-231
A Portable Endstation for Analytical X-ray Microscopy Using Soft X-ray Synchrotron Radiation
A Portable Endstation for Analytical X-ray Microscopy Using Soft X-ray Synchrotron Radiation - Volume 24 Issue S2
- 10 August 2018
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 24 (S2) , 230-231
A Portable Endstation for Analytical X-ray Microscopy Using Soft X-ray Synchrotron Radiation
A Portable Endstation for Analytical X-ray Microscopy Using Soft X-ray Synchrotron Radiation - Volume 24 Issue S2