Matthew R. Dimmock
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Matthew R. Dimmock has a total of 96 co-authors. Here are the top co-authors by number of shared publications:
- Richard Bassed
Department of Forensic Medicine, Monash University, Southbank, Australia
8 shared publications - Edel Doyle
Monash University, Department of Forensic Medicine, Melbourne, VIC, Australia
5 shared publications - Kam L. Lee
Australian Radiation Protection and Nuclear Safety Agency, Yallambie, Australia
5 shared publications - Chris Hall
Australian Synchrotron, Clayton, Australia
4 shared publications - Sarah Lewis
Discipline of Medical Imaging Science, School of Health Sciences, Faculty of Medicine and Health, University of Sydney, Sydney 2006, Australia
4 shared publications - Seyedamir Tavakoli Taba
Medical Image Optimisation and Perceptions Group, Discipline of Medical Imaging Science, Faculty of Medicine and Health, The University of Sydney, Australia
4 shared publications
Latest Publications
- Open Access
- 24 January 2026
- Published by Elsevier in Radiography
- Vol. 32 (3) , 103333
Fracture detection using a low-dose computed tomography paediatric bone fracture phantom: A multi-reader study of radiographers
- 24 January 2026
- Published by Elsevier in Radiography
- Vol. 32 (3) , 103333
Open AccessFracture detection using a low-dose computed tomography paediatric bone fracture phantom: A multi-reader study of radiographers
- Open Access
- 6 November 2025
- Published by Elsevier in Radiography
- Vol. 32 (1) , 103214
Clinical and MRI variables in decision support systems for prostate MRI: A systematic review of decision support tools, nomograms, and risk models
- 6 November 2025
- Published by Elsevier in Radiography
- Vol. 32 (1) , 103214
Open AccessClinical and MRI variables in decision support systems for prostate MRI: A systematic review of decision support tools, nomograms, and risk models
- Open Access
- 13 February 2025
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 73 (S2) , S9-S25
Proposed Diagnostic Reference Levels for Frequently Performed Paediatric Radiographic Examinations
Introduction: Paediatric diagnostic reference levels (DRLs) are dose levels for typical medical imaging examinations for broadly defined types of equipment with weight‐stratification preferred by the International Commission on Radiological Protection. Australia has never published paediatric DRLs for general radiography. The aim of this study was to collect radiation dose metrics for commonly performed radiographic projections in children in Australia and propose weight‐based DRLs. Methods: Ethics approval was granted to collect data, along with a waiver of consent. Radiographs were acquired in accordance with local protocols using direct digital X‐ray equipment for children who presented for routine radiographic imaging. A spreadsheet was provided to each centre to record the patient's age and weight, as well as tube voltage and current‐time product, source‐to‐image distance, use of a grid, additional filtration, automatic exposure control chamber selection and the displayed air kerma area product (KAP). Facility reference levels (FRLs) were calculated as the median for each X‐ray unit based on data submitted for a minimum of three patients. The 75th percentiles of the FRLs across nine X‐ray units from five centres were calculated as the proposed Local DRLs (LDRLs). Results: The most commonly radiographed body parts in children were the chest, wrist, abdomen, elbow and foot. The proposed LDRLs range from 4 mGy•cm 2 (oblique hand in 5–15 kg) to 884 mGy•cm 2 (antero‐posterior pelvis in 50–80 kg). Conclusion: The estimation of LDRLs for radiographs from a weight‐based patient study offers Australian reference values for guidance in the optimisation process.
- 13 February 2025
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 73 (S2) , S9-S25
Open AccessProposed Diagnostic Reference Levels for Frequently Performed Paediatric Radiographic Examinations
Introduction: Paediatric diagnostic reference levels (DRLs) are dose levels for typical medical imaging examinations for broadly defined types of equipment with weight‐stratification preferred by the International Commission on Radiological Protection. Australia has never published paediatric DRLs for general radiography. The aim of this study was to collect radiation dose metrics for commonly performed radiographic projections in children in Australia and propose weight‐based DRLs. Methods: Ethics approval was granted to collect data, along with a waiver of consent. Radiographs were acquired in accordance with local protocols using direct digital X‐ray equipment for children who presented for routine radiographic imaging. A spreadsheet was provided to each centre to record the patient's age and weight, as well as tube voltage and current‐time product, source‐to‐image distance, use of a grid, additional filtration, automatic exposure control chamber selection and the displayed air kerma area product (KAP). Facility reference levels (FRLs) were calculated as the median for each X‐ray unit based on data submitted for a minimum of three patients. The 75th percentiles of the FRLs across nine X‐ray units from five centres were calculated as the proposed Local DRLs (LDRLs). Results: The most commonly radiographed body parts in children were the chest, wrist, abdomen, elbow and foot. The proposed LDRLs range from 4 mGy•cm 2 (oblique hand in 5–15 kg) to 884 mGy•cm 2 (antero‐posterior pelvis in 50–80 kg). Conclusion: The estimation of LDRLs for radiographs from a weight‐based patient study offers Australian reference values for guidance in the optimisation process.
- Open Access
- 15 April 2024
- Published by Springer Nature in International journal of legal medicine
- Vol. 138 (5) , 1857-1866
Effectiveness of low dose computed tomography to detect fractures in paediatric suspected physical abuse: a systematic review
Purpose: The skeletal survey X-ray series is the current ‘gold standard’ when investigating suspected physical abuse (SPA) of children, in addition to a non-contrast computed tomography (CT) brain scan. This systematic literature review synthesised findings of published research to determine if low dose computed tomography (LDCT) could detect subtle fractures and therefore replace the skeletal survey X-ray series in the investigation of SPA in children aged under 3 years. Methods: Five electronic databases and grey literature were systematically searched from their inception to 28 April 2022. Primary studies were included where the population comprised paediatric patients up to 16 years and LDCT was used to detect fractures associated with SPA. Studies involving imaging investigations of the head, standard dose CT examinations or accidental trauma were excluded. Results: Three studies met the inclusion criteria, all of which were case series. These studies did not report many of the criteria required to compare the accuracy of LDCT to X-ray, i.e. they did not meet the criteria for a diagnostic accuracy test. Therefore, it is difficult to conclude from the case series if LDCT is accurate enough to replace X-rays. Conclusion: Due to the gap in current literature, a phantom study and subsequent post-mortem CT study are recommended as the primary investigative methods to assess the ability of low-dose CT to identify the subtle fractures associated with SPA and to calculate how low the achievable CT dose can be.
- 15 April 2024
- Published by Springer Nature in International journal of legal medicine
- Vol. 138 (5) , 1857-1866
Open AccessEffectiveness of low dose computed tomography to detect fractures in paediatric suspected physical abuse: a systematic review
Purpose: The skeletal survey X-ray series is the current ‘gold standard’ when investigating suspected physical abuse (SPA) of children, in addition to a non-contrast computed tomography (CT) brain scan. This systematic literature review synthesised findings of published research to determine if low dose computed tomography (LDCT) could detect subtle fractures and therefore replace the skeletal survey X-ray series in the investigation of SPA in children aged under 3 years. Methods: Five electronic databases and grey literature were systematically searched from their inception to 28 April 2022. Primary studies were included where the population comprised paediatric patients up to 16 years and LDCT was used to detect fractures associated with SPA. Studies involving imaging investigations of the head, standard dose CT examinations or accidental trauma were excluded. Results: Three studies met the inclusion criteria, all of which were case series. These studies did not report many of the criteria required to compare the accuracy of LDCT to X-ray, i.e. they did not meet the criteria for a diagnostic accuracy test. Therefore, it is difficult to conclude from the case series if LDCT is accurate enough to replace X-rays. Conclusion: Due to the gap in current literature, a phantom study and subsequent post-mortem CT study are recommended as the primary investigative methods to assess the ability of low-dose CT to identify the subtle fractures associated with SPA and to calculate how low the achievable CT dose can be.
- Open Access
- 21 January 2024
- Published by Elsevier in EBioMedicine
- Vol. 100, 104976
Brainstem processing of cough sensory inputs in chronic cough hypersensitivity
- 21 January 2024
- Published by Elsevier in EBioMedicine
- Vol. 100, 104976
Open AccessBrainstem processing of cough sensory inputs in chronic cough hypersensitivity
- Open Access
- 21 August 2023
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 71 (1) , 35-43
Comparison of typical radiation doses and risks using an anthropomorphic ‘bone fracture’ phantom for commonly performed X‐ray projections in a 5‐year‐old
Introduction: Diagnostic reference levels (DRLs) are typical dose levels for medical imaging examinations for groups of standard-sized patients or standard phantoms for broadly defined types of equipment used as a tool to aid optimisation of protection for medical exposures. Currently, there are no paediatric DRLs for conventional radiography (i.e. general X-rays) published in Australia. The aim of this study was to establish typical radiation doses and risks that are representative of those delivered for commonly performed X-ray projections for a 5-year-old/20 kg child using a 5-year-old anthropomorphic 'bone fracture' phantom in three dedicated paediatric radiology departments in Victoria. Methods: A total of 20 projection images were acquired for a standard 5-year-old/20 kg phantom using digital radiography X-ray equipment. The air kerma-area product (KAP) measured at each centre by a KAP metre, which was calibrated to a national primary standard, was considered to represent the median value for that centre for each X-ray projection. Organ doses and effective dose were estimated using PCXMC software, and risks of radiation-induced cancer and radiation-induced death were calculated based on the BEIR VII report. Results: The typical doses for the individual X-ray projections ranged from 3 mGy & BULL;cm(2) to 86 mGy & BULL;cm(2), whilst the effective doses ranged from 0.00004 to 0.07 mSv. The radiation risks were 'minimal' to 'negligible'. Conclusion: The estimation of typical radiation doses and associated risks for a 5-year-old/20 kg phantom study provides reference values for guidance and is a first step in assisting optimisation at other institutions until national DRLs, based on patient data from the clinical setting, are published.
- 21 August 2023
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 71 (1) , 35-43
Open AccessComparison of typical radiation doses and risks using an anthropomorphic ‘bone fracture’ phantom for commonly performed X‐ray projections in a 5‐year‐old
Introduction: Diagnostic reference levels (DRLs) are typical dose levels for medical imaging examinations for groups of standard-sized patients or standard phantoms for broadly defined types of equipment used as a tool to aid optimisation of protection for medical exposures. Currently, there are no paediatric DRLs for conventional radiography (i.e. general X-rays) published in Australia. The aim of this study was to establish typical radiation doses and risks that are representative of those delivered for commonly performed X-ray projections for a 5-year-old/20 kg child using a 5-year-old anthropomorphic 'bone fracture' phantom in three dedicated paediatric radiology departments in Victoria. Methods: A total of 20 projection images were acquired for a standard 5-year-old/20 kg phantom using digital radiography X-ray equipment. The air kerma-area product (KAP) measured at each centre by a KAP metre, which was calibrated to a national primary standard, was considered to represent the median value for that centre for each X-ray projection. Organ doses and effective dose were estimated using PCXMC software, and risks of radiation-induced cancer and radiation-induced death were calculated based on the BEIR VII report. Results: The typical doses for the individual X-ray projections ranged from 3 mGy & BULL;cm(2) to 86 mGy & BULL;cm(2), whilst the effective doses ranged from 0.00004 to 0.07 mSv. The radiation risks were 'minimal' to 'negligible'. Conclusion: The estimation of typical radiation doses and associated risks for a 5-year-old/20 kg phantom study provides reference values for guidance and is a first step in assisting optimisation at other institutions until national DRLs, based on patient data from the clinical setting, are published.
- Open Access
- 22 August 2022
- Published by Springer Nature in Pediatric Radiology
- Vol. 53 (1) , 57-68
Typical median effective radiation doses using an anthropomorphic bone fracture phantom for initial radiographic skeletal surveys in the investigation of suspected physical abuse
Background: A series of 31 radiographs is recommended by the Royal College of Radiologists (RCR) when investigating suspected physical abuse (SPA). Objective: To determine the radiation dose delivered for skeletal surveys performed for SPA in Victorian radiology departments based on their local protocols. Materials and methods: A 5-year-old paediatric bone fracture phantom was radiographed at five radiology sites using both the RCR recommended protocol and, where applicable, the local departmental SPA protocol. The radiation doses were measured and recorded. These were scaled down to estimate the effective radiation doses for a 2-year-old child at each site and the associated radiation risks estimated. Results: The median effective dose for all radiographic projections in the RCR skeletal survey radiographic series was 0.09 mSv. The estimated risk of radiation-induced cancer and radiation-induced death from cancer for 2-year-old children is classified as “very low,” with girls having a higher risk than boys. Conclusion: The median effective radiation dose for the RCR skeletal survey for imaging in SPA was 0.09 mSv resulting in a “very low” additional risk of radiation-induced cancer. The authors will now aim to ascertain whether whole-body CT skeletal survey can replace the radiographic series for imaging in SPA while maintaining a comparable radiation dose.
- 22 August 2022
- Published by Springer Nature in Pediatric Radiology
- Vol. 53 (1) , 57-68
Open AccessTypical median effective radiation doses using an anthropomorphic bone fracture phantom for initial radiographic skeletal surveys in the investigation of suspected physical abuse
Background: A series of 31 radiographs is recommended by the Royal College of Radiologists (RCR) when investigating suspected physical abuse (SPA). Objective: To determine the radiation dose delivered for skeletal surveys performed for SPA in Victorian radiology departments based on their local protocols. Materials and methods: A 5-year-old paediatric bone fracture phantom was radiographed at five radiology sites using both the RCR recommended protocol and, where applicable, the local departmental SPA protocol. The radiation doses were measured and recorded. These were scaled down to estimate the effective radiation doses for a 2-year-old child at each site and the associated radiation risks estimated. Results: The median effective dose for all radiographic projections in the RCR skeletal survey radiographic series was 0.09 mSv. The estimated risk of radiation-induced cancer and radiation-induced death from cancer for 2-year-old children is classified as “very low,” with girls having a higher risk than boys. Conclusion: The median effective radiation dose for the RCR skeletal survey for imaging in SPA was 0.09 mSv resulting in a “very low” additional risk of radiation-induced cancer. The authors will now aim to ascertain whether whole-body CT skeletal survey can replace the radiographic series for imaging in SPA while maintaining a comparable radiation dose.
- 18 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 41 (11) , 2980-2990
Imaging Breast Microcalcifications Using Dark-Field Signal in Propagation-Based Phase-Contrast Tomography
Breast microcalcifications are an important primary radiological indicator of breast cancer. However, microcalcification classification and diagnosis may be still challenging for radiologists due to limitations of the standard 2D mammography technique, including spatial and contrast resolution. In this study, we propose an approach to improve the detection of microcalcifications in propagation-based phase-contrast X-ray computed tomography of breast tissues. Five fresh mastectomies containing microcalcifications were scanned at different X-ray energies and radiation doses using synchrotron radiation. Both bright-field (i.e. conventional phase-retrieved images) and dark-field images were extracted from the same data sets using different image processing methods. A quantitative analysis was performed in terms of visibility and contrast-to-noise ratio of microcalcifications. The results show that while the signal-to-noise and the contrast-to-noise ratios are lower, the visibility of the microcalcifications is more than two times higher in the dark-field images compared to the bright-field images. Dark-field images have also provided more accurate information about the size and shape of the microcalcifications.
- 18 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 41 (11) , 2980-2990
Imaging Breast Microcalcifications Using Dark-Field Signal in Propagation-Based Phase-Contrast Tomography
Breast microcalcifications are an important primary radiological indicator of breast cancer. However, microcalcification classification and diagnosis may be still challenging for radiologists due to limitations of the standard 2D mammography technique, including spatial and contrast resolution. In this study, we propose an approach to improve the detection of microcalcifications in propagation-based phase-contrast X-ray computed tomography of breast tissues. Five fresh mastectomies containing microcalcifications were scanned at different X-ray energies and radiation doses using synchrotron radiation. Both bright-field (i.e. conventional phase-retrieved images) and dark-field images were extracted from the same data sets using different image processing methods. A quantitative analysis was performed in terms of visibility and contrast-to-noise ratio of microcalcifications. The results show that while the signal-to-noise and the contrast-to-noise ratios are lower, the visibility of the microcalcifications is more than two times higher in the dark-field images compared to the bright-field images. Dark-field images have also provided more accurate information about the size and shape of the microcalcifications.
- Open Access
- 1 January 2022
- Published by Elsevier in Medical Dosimetry
- Vol. 47 (1) , 92-97
Application of an automated dose accumulation workflow in high-risk prostate cancer - validation and dose-volume analysis between planned and delivered dose
- 1 January 2022
- Published by Elsevier in Medical Dosimetry
- Vol. 47 (1) , 92-97
Open AccessApplication of an automated dose accumulation workflow in high-risk prostate cancer - validation and dose-volume analysis between planned and delivered dose
- Open Access
- 1 September 2021
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 502, 176-182
An electromagnetic physics constructor for low energy polarised X-/gamma ray transport in Geant4
- 1 September 2021
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 502, 176-182
Open AccessAn electromagnetic physics constructor for low energy polarised X-/gamma ray transport in Geant4