Sławomir Grabarczyk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Sławomir Grabarczyk has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
- Robert Grabarczyk
Faculty of Civil Engineering, Mechanics and Petrochemistry, Warsaw University of Technology, 17 Łukasiewicza St., 09-400 Płock, Poland
1 shared publication
Latest Publications
- Open Access
- 1 September 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (17) , 8786
Cumulative Energy Demand and Carbon Footprint of the Greenhouse Cultivation System
The paper describes the influence of horticultural production in greenhouses under Polish climate conditions on energy consumption, contributing to greenhouse gas emissions and global warming. Four scenarios were studied, two of which were non-renewable fuels: coal and natural gas, while the other two were renewable energy sources: wood pellets and wood chips, to identify opportunities for reducing energy costs and greenhouse gas emissions. Cumulative energy demand was defined to assess these four scenarios. The environmental impact was determined using the carbon footprint of the principal greenhouse gases emitted and using CO2 as the reference gas (CO2-equivalents). Renewable energy sources in greenhouse production can reduce the cumulative energy demand by 83.3% and greenhouse gas emissions by 95% compared to the coal-burning scenario. The presented research results relate to a greenhouse intended for growing flowers in pots, which has not been conducted so far. The article also updates the data on the environmental impact of crops grown in greenhouses located in Poland. The study provides important information for horticultural producers, mainly due to increasing competition and consumer awareness of the origin of products. Renewable energy sources in horticulture reveal a great potential in the reduction in greenhouse gases, and thus may become an inspiration to look for new solutions in this area.
- 1 September 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (17) , 8786
Open AccessCumulative Energy Demand and Carbon Footprint of the Greenhouse Cultivation System
The paper describes the influence of horticultural production in greenhouses under Polish climate conditions on energy consumption, contributing to greenhouse gas emissions and global warming. Four scenarios were studied, two of which were non-renewable fuels: coal and natural gas, while the other two were renewable energy sources: wood pellets and wood chips, to identify opportunities for reducing energy costs and greenhouse gas emissions. Cumulative energy demand was defined to assess these four scenarios. The environmental impact was determined using the carbon footprint of the principal greenhouse gases emitted and using CO2 as the reference gas (CO2-equivalents). Renewable energy sources in greenhouse production can reduce the cumulative energy demand by 83.3% and greenhouse gas emissions by 95% compared to the coal-burning scenario. The presented research results relate to a greenhouse intended for growing flowers in pots, which has not been conducted so far. The article also updates the data on the environmental impact of crops grown in greenhouses located in Poland. The study provides important information for horticultural producers, mainly due to increasing competition and consumer awareness of the origin of products. Renewable energy sources in horticulture reveal a great potential in the reduction in greenhouse gases, and thus may become an inspiration to look for new solutions in this area.
- Open Access
- 13 August 2018
- Published by EDP Sciences
- Vol. 49, 00037
Modeling of heat consumption in a greenhouse using experimental data
The use of experimental research results to teach artificial neural networks was aimed at determining the relationship between heat consumption and measured variables. The mechanism of changes in heat consumption was determined by changes in external climate parameters, microclimate conditions in the greenhouse and parameters describing the functioning of the technical equipment of the facility. The accuracy of modeling the heat consumption in the case of changes in the properties of the building's external partitions has been determined. In a greenhouse, this is related to the functioning of an additional movable curtain - a thermal screen. MLP networks - multilayer perceptrons with hidden layers proved to be particularly useful for predicting changes in heat consumption. In the analysis attention was paid to the accuracy of modeling depending on the size of the measurement data set. The sources of information are collections with different intervals between registered measurement records, which were collected during the tests carried out during the full calendar year.
- 13 August 2018
- Published by EDP Sciences
- Vol. 49, 00037
Open AccessModeling of heat consumption in a greenhouse using experimental data
The use of experimental research results to teach artificial neural networks was aimed at determining the relationship between heat consumption and measured variables. The mechanism of changes in heat consumption was determined by changes in external climate parameters, microclimate conditions in the greenhouse and parameters describing the functioning of the technical equipment of the facility. The accuracy of modeling the heat consumption in the case of changes in the properties of the building's external partitions has been determined. In a greenhouse, this is related to the functioning of an additional movable curtain - a thermal screen. MLP networks - multilayer perceptrons with hidden layers proved to be particularly useful for predicting changes in heat consumption. In the analysis attention was paid to the accuracy of modeling depending on the size of the measurement data set. The sources of information are collections with different intervals between registered measurement records, which were collected during the tests carried out during the full calendar year.
- Open Access
- 13 August 2018
- Published by EDP Sciences
- Vol. 49, 00036
Analysis of the influence of selected factors on natural greenhouse ventilation
In greenhouses, in order to maintain proper indoor air temperature, during the period of high values of solar radiation intensity, shading treatments using thermal screens and ventilation are applied. The research was carried out in a mono-span greenhouse in order to determine the effectiveness of natural ventilation. The object of analysis is a greenhouse with a thermal screen installed inside. The tests were carried out during the summer days. The effect of the research was to determine the ventilation air flow through the vents of the greenhouse on the basis of measurements and calculation analyzes. The dependence of the air flow on the windward and leeward side was determined from the wind speed and the temperature difference between the indoor and outdoor air. On the basis of calculations made from observation during shading of the cultivated area and with open ventilators, the coefficients of air exchange per unit floor area of the greenhouse were determined. It was established that at a wind speed exceeding 0.8 m/s, the air exchange rate in the tested greenhouse exceeds the value recommended by the American Society of Agricultural Engineers of 0.04 m3/(s.m2).
- 13 August 2018
- Published by EDP Sciences
- Vol. 49, 00036
Open AccessAnalysis of the influence of selected factors on natural greenhouse ventilation
In greenhouses, in order to maintain proper indoor air temperature, during the period of high values of solar radiation intensity, shading treatments using thermal screens and ventilation are applied. The research was carried out in a mono-span greenhouse in order to determine the effectiveness of natural ventilation. The object of analysis is a greenhouse with a thermal screen installed inside. The tests were carried out during the summer days. The effect of the research was to determine the ventilation air flow through the vents of the greenhouse on the basis of measurements and calculation analyzes. The dependence of the air flow on the windward and leeward side was determined from the wind speed and the temperature difference between the indoor and outdoor air. On the basis of calculations made from observation during shading of the cultivated area and with open ventilators, the coefficients of air exchange per unit floor area of the greenhouse were determined. It was established that at a wind speed exceeding 0.8 m/s, the air exchange rate in the tested greenhouse exceeds the value recommended by the American Society of Agricultural Engineers of 0.04 m3/(s.m2).