Yoshiyuki Hirano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yoshiyuki Hirano has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Hikaru Souda
Heavy Ion Medical Center, Gunma University, 3-39-22 Showa-Machi, Maebashi, Gunma, 371-8511, Japan
2 shared publicationsMasami Torikoshi
Heavy Ion Medical Center, Gunma University, 3-39-22 Showa-Machi, Maebashi, Gunma, 371-8511, Japan
2 shared publications- Satoshi Kodaira
National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan
2 shared publications - Seiichi Yamamoto
Waseda University
2 shared publications Tsukasa Aso
Electronics and Computer Engineering, National Institute of Technology, Toyama College, Japan
2 shared publications- Akie Nagao
Department of Electronics and Informatics, Gunma University, Kiryu 376-8515, Gunma, Japan
1 shared publication
Latest Publications
- 24 April 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (19)
Raman spectroscopy-based DNA damage profile induced by UVB, UVC, and gamma-ray irradiation under equivalent energy absorption conditions
Linear energy transfer (LET) is commonly used as an indicator of radiation quality in radiation therapy. In contrast, Raman spectroscopy may provide a more detailed and sensitive measure of radiation quality than LET. Raman spectroscopy was used to characterize DNA damage induced by UVB, UVC, and gamma-ray irradiation under equivalent energy absorption conditions. A total of 89 Raman bands were identified in non-irradiated DNA, among which 79 displayed intensity or positional changes after irradiation. We introduced a "damage profile," which summarizes changes in Raman intensity and band position to characterize the molecular state of DNA. The overall intensity-based damage profiles showed similar tendencies among the three radiation types. In contrast, shift-based profiles revealed distinct patterns: UVB and UVC were comparable, whereas gamma-rays showed clearly different behavior, consistent with their distinct damage mechanisms. UV irradiation produced pronounced perturbations in both pyrimidine-related bands and backbone-associated vibrations, reflecting pyrimidine dimer formation and local conformational changes. Gamma-ray irradiation caused more localized but characteristic modifications, particularly in guanine-associated bands indicative of oxidative lesions. These results demonstrate that Raman-based DNA damage profiles provide sensitive molecular fingerprints capable of distinguishing radiation quality and may contribute to improved prediction of biological effectiveness in radiation therapy.
- 24 April 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (19)
Raman spectroscopy-based DNA damage profile induced by UVB, UVC, and gamma-ray irradiation under equivalent energy absorption conditions
Linear energy transfer (LET) is commonly used as an indicator of radiation quality in radiation therapy. In contrast, Raman spectroscopy may provide a more detailed and sensitive measure of radiation quality than LET. Raman spectroscopy was used to characterize DNA damage induced by UVB, UVC, and gamma-ray irradiation under equivalent energy absorption conditions. A total of 89 Raman bands were identified in non-irradiated DNA, among which 79 displayed intensity or positional changes after irradiation. We introduced a "damage profile," which summarizes changes in Raman intensity and band position to characterize the molecular state of DNA. The overall intensity-based damage profiles showed similar tendencies among the three radiation types. In contrast, shift-based profiles revealed distinct patterns: UVB and UVC were comparable, whereas gamma-rays showed clearly different behavior, consistent with their distinct damage mechanisms. UV irradiation produced pronounced perturbations in both pyrimidine-related bands and backbone-associated vibrations, reflecting pyrimidine dimer formation and local conformational changes. Gamma-ray irradiation caused more localized but characteristic modifications, particularly in guanine-associated bands indicative of oxidative lesions. These results demonstrate that Raman-based DNA damage profiles provide sensitive molecular fingerprints capable of distinguishing radiation quality and may contribute to improved prediction of biological effectiveness in radiation therapy.
- Open Access
- 19 January 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (3) , 035001
Accessibility of deoxyribose hydrogens to hydroxyl radicals in nucleosomal and naked DNA in water: a molecular dynamics study with LAMMPS
Ionizing radiation induces DNA damage both directly and indirectly through hydroxyl radicals (·OH) generated by water radiolysis. The indirect action involves hydrogen abstraction from deoxyribose, leading to DNA damage such as base release and strand breaks. The probability of such events depends on the accessibility of specific hydrogen atoms to ·OH radicals. Previous computational studies have examined naked DNA fragments; however, the effect of nucleosomal organization has not been addressed. Here, we performed molecular dynamics (MD) simulations using LAMMPS (Large-scale Atomic Molecular Massively Parallel Simulator) to evaluate the accessibility of ·OH radicals to deoxyribose hydrogens in both 12-bp naked B-type DNA and nucleosomal DNA containing histone proteins. The accessibility to the hydrogens increased, following the order H1′ ≈ H2′ ≈ H3′ < H4′ < H5′, consistent with previous studies. Accessibility was approximately proportional to the solvent accessible surface area (SASA), supporting SASA as a practical predictor of accessibility even in base-dependent differences were observed. In nucleosomal DNA, accessibility of hydrogens facing the histone core was significantly reduced compared to solvent-facing hydrogens, despite comparable SASA values. This reduction suggests that histones physically hinder ·OH radical penetration. These findings highlight the importance of considering protein–DNA complexes when modeling indirect radiation effects.
- 19 January 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (3) , 035001
Open AccessAccessibility of deoxyribose hydrogens to hydroxyl radicals in nucleosomal and naked DNA in water: a molecular dynamics study with LAMMPS
Ionizing radiation induces DNA damage both directly and indirectly through hydroxyl radicals (·OH) generated by water radiolysis. The indirect action involves hydrogen abstraction from deoxyribose, leading to DNA damage such as base release and strand breaks. The probability of such events depends on the accessibility of specific hydrogen atoms to ·OH radicals. Previous computational studies have examined naked DNA fragments; however, the effect of nucleosomal organization has not been addressed. Here, we performed molecular dynamics (MD) simulations using LAMMPS (Large-scale Atomic Molecular Massively Parallel Simulator) to evaluate the accessibility of ·OH radicals to deoxyribose hydrogens in both 12-bp naked B-type DNA and nucleosomal DNA containing histone proteins. The accessibility to the hydrogens increased, following the order H1′ ≈ H2′ ≈ H3′ < H4′ < H5′, consistent with previous studies. Accessibility was approximately proportional to the solvent accessible surface area (SASA), supporting SASA as a practical predictor of accessibility even in base-dependent differences were observed. In nucleosomal DNA, accessibility of hydrogens facing the histone core was significantly reduced compared to solvent-facing hydrogens, despite comparable SASA values. This reduction suggests that histones physically hinder ·OH radical penetration. These findings highlight the importance of considering protein–DNA complexes when modeling indirect radiation effects.
- 4 December 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 11 (1) , 015027
Effect of Cherenkov light on cell survival in x-ray irradiation of LINAC based on Monte Carlo simulation and cell survival measurements
Cherenkov radiation is emitted during x-ray irradiation in a linear accelerator (LINAC). Cherenkov light contains many short wavelength components, including ultraviolet (UV) light, which is well-known for its bactericidal effects. A similar phenomenon is probable for human cancer cells. To assess the effect of Cherenkov light on cell death in x-ray irradiation, we employed simulations and UV cell survival data. We measured the survival rates of HeLa cells exposed to 254 nm (UVC) and 310 nm (UVB) light to determine the 50% lethal dose (LD50) required to kill 50% of the cells. For other wavelengths, we utilized literature values to establish the relationship between wavelength and LD50. Due to the broad range of the Cherenkov light spectrum, we need LD50 as a function of wavelength to estimate cell survival solely from Cherenkov light. A Monte Carlo simulation was used to calculate the fluence distribution of Cherenkov light in a 300 mm3 phantom comprised of soft tissue, both with and without absorption of visible light. The latter scenario is considered to be most influenced by Cherenkov light. By combining the fluence distribution and the wavelength-LD50 relationship, we determined the distribution of the survival rate. Our findings indicate that, in the absence of absorption, a radiation dose of approximately 90 Gy or greater is necessary for Cherenkov light to have any effect. As a result, the impact of Cherenkov light on cell survival can be considered negligible for typical dose of 2 Gy.
- 4 December 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 11 (1) , 015027
Effect of Cherenkov light on cell survival in x-ray irradiation of LINAC based on Monte Carlo simulation and cell survival measurements
Cherenkov radiation is emitted during x-ray irradiation in a linear accelerator (LINAC). Cherenkov light contains many short wavelength components, including ultraviolet (UV) light, which is well-known for its bactericidal effects. A similar phenomenon is probable for human cancer cells. To assess the effect of Cherenkov light on cell death in x-ray irradiation, we employed simulations and UV cell survival data. We measured the survival rates of HeLa cells exposed to 254 nm (UVC) and 310 nm (UVB) light to determine the 50% lethal dose (LD50) required to kill 50% of the cells. For other wavelengths, we utilized literature values to establish the relationship between wavelength and LD50. Due to the broad range of the Cherenkov light spectrum, we need LD50 as a function of wavelength to estimate cell survival solely from Cherenkov light. A Monte Carlo simulation was used to calculate the fluence distribution of Cherenkov light in a 300 mm3 phantom comprised of soft tissue, both with and without absorption of visible light. The latter scenario is considered to be most influenced by Cherenkov light. By combining the fluence distribution and the wavelength-LD50 relationship, we determined the distribution of the survival rate. Our findings indicate that, in the absence of absorption, a radiation dose of approximately 90 Gy or greater is necessary for Cherenkov light to have any effect. As a result, the impact of Cherenkov light on cell survival can be considered negligible for typical dose of 2 Gy.
- 13 November 2024
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 200 (16-18) , 1787-1791
Monitoring of tritium concentrations in tap water and rainwater collected in Thailand
This study aimed to measure tritium (3H) concentrations in Thailand. Nationwide tap water samples were collected in July 2021. Rainwater samples were collected monthly during May–October 2020, April–October 2021, and February–March 2022 in Chonburi province and in Chiang Mai province during July–November 2021, January 2022, and March–June 2022. The measurements of 3H activity concentrations were conducted by Osaka Sangyo University (OSU) and were compared with measurements by the Thailand Institute of Nuclear Technology (TINT). The results from OSU and TINT showed that 3H concentrations in tap water were matched in the ranged from 0.08 ± 0.03 to 0.28 ± 0.04 Bq L−1, while those in rainwater samples collected from Chonburi province and Chiang Mai province are also matched in the ranged from 0.11 ± 0.02 to 0.21 ± 0.03 Bq L−1 and 0.19 ± 0.02 to 0.57 ± 0.04 Bq L−1, respectively. Our measured result suggests that 3H concentration in tap water and rainwater shows a similar relation depending on latitude.
- 13 November 2024
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 200 (16-18) , 1787-1791
Monitoring of tritium concentrations in tap water and rainwater collected in Thailand
This study aimed to measure tritium (3H) concentrations in Thailand. Nationwide tap water samples were collected in July 2021. Rainwater samples were collected monthly during May–October 2020, April–October 2021, and February–March 2022 in Chonburi province and in Chiang Mai province during July–November 2021, January 2022, and March–June 2022. The measurements of 3H activity concentrations were conducted by Osaka Sangyo University (OSU) and were compared with measurements by the Thailand Institute of Nuclear Technology (TINT). The results from OSU and TINT showed that 3H concentrations in tap water were matched in the ranged from 0.08 ± 0.03 to 0.28 ± 0.04 Bq L−1, while those in rainwater samples collected from Chonburi province and Chiang Mai province are also matched in the ranged from 0.11 ± 0.02 to 0.21 ± 0.03 Bq L−1 and 0.19 ± 0.02 to 0.57 ± 0.04 Bq L−1, respectively. Our measured result suggests that 3H concentration in tap water and rainwater shows a similar relation depending on latitude.
- Open Access
- 1 January 2024
- Published by Japan Society for Simulation Technology in Journal of Advanced Simulation in Science and Engineering
- Vol. 11 (1) , 207-221
Estimation of produced oxygens in the track of heavy-ion using Geant4-DNA
In X-ray irradiation, decreasing oxygen concentration correlates with a reduction in radiosensitivity. However, this effect is minimal in heavy ion irradiation due to the generation of oxygen along the ion track, called as the "oxygen in the heavy ion track hypothesis." We verified this hypothesis using Geant4-DNA by calculating oxygen generation and time change in distribution for 35 MeV/u and 200 MeV/u carbon ions, and 1 MeV electrons within a cell nucleus. The results showed, under hypoxic conditions (0% dissolved oxygen), the oxygen concentration increased to a maximum of 3.7% in a localized region around the track, persisting for about 100 ns after the penetration of 35 MeV/u carbon ion, while the increase for 1 MeV electrons was negligible. This finding supports the validity of the oxygen in the heavy ion track hypothesis.
- 1 January 2024
- Published by Japan Society for Simulation Technology in Journal of Advanced Simulation in Science and Engineering
- Vol. 11 (1) , 207-221
Open AccessEstimation of produced oxygens in the track of heavy-ion using Geant4-DNA
In X-ray irradiation, decreasing oxygen concentration correlates with a reduction in radiosensitivity. However, this effect is minimal in heavy ion irradiation due to the generation of oxygen along the ion track, called as the "oxygen in the heavy ion track hypothesis." We verified this hypothesis using Geant4-DNA by calculating oxygen generation and time change in distribution for 35 MeV/u and 200 MeV/u carbon ions, and 1 MeV electrons within a cell nucleus. The results showed, under hypoxic conditions (0% dissolved oxygen), the oxygen concentration increased to a maximum of 3.7% in a localized region around the track, persisting for about 100 ns after the penetration of 35 MeV/u carbon ion, while the increase for 1 MeV electrons was negligible. This finding supports the validity of the oxygen in the heavy ion track hypothesis.
- Open Access
Calculation of Stopping-Power Ratio from Multiple CT Numbers Using Photon-Counting CT System: Two- and Three-Parameter-Fitting Method
The two-parameter-fitting method (PFM) is commonly used to calculate the stopping-power ratio (SPR). This study proposes a new formalism: a three-PFM, which can be used in multiple spectral computed tomography (CT). Using a photon-counting CT system, seven rod-shaped samples of aluminium, graphite, and poly(methyl methacrylate) (PMMA), and four types of biological phantom materials were placed in a water-filled sample holder. The X-ray tube voltage and current were set at 150 kV and 40 μA respectively, and four CT images were obtained at four threshold settings. A semi-empirical correction method that corrects the difference between the CT values from the photon-counting CT images and theoretical values in each spectral region was also introduced. Both the two- and three-PFMs were used to calculate the effective atomic number and electron density from multiple CT numbers. The mean excitation energy was calculated via parameterisation with the effective atomic number, and the SPR was then calculated from the calculated electron density and mean excitation energy. Then, the SPRs from both methods were compared with the theoretical values. To estimate the noise level of the CT numbers obtained from the photon-counting CT, CT numbers, including noise, were simulated to evaluate the robustness of the aforementioned PFMs. For the aluminium and graphite, the maximum relative errors for the SPRs calculated using the two-PFM and three-PFM were 17.1% and 7.1%, respectively. For the PMMA and biological phantom materials, the maximum relative errors for the SPRs calculated using the two-PFM and three-PFM were 5.5% and 2.0%, respectively. It was concluded that the three-PFM, compared with the two-PFM, can yield SPRs that are closer to the theoretical values and is less affected by noise.Open AccessCalculation of Stopping-Power Ratio from Multiple CT Numbers Using Photon-Counting CT System: Two- and Three-Parameter-Fitting Method
The two-parameter-fitting method (PFM) is commonly used to calculate the stopping-power ratio (SPR). This study proposes a new formalism: a three-PFM, which can be used in multiple spectral computed tomography (CT). Using a photon-counting CT system, seven rod-shaped samples of aluminium, graphite, and poly(methyl methacrylate) (PMMA), and four types of biological phantom materials were placed in a water-filled sample holder. The X-ray tube voltage and current were set at 150 kV and 40 μA respectively, and four CT images were obtained at four threshold settings. A semi-empirical correction method that corrects the difference between the CT values from the photon-counting CT images and theoretical values in each spectral region was also introduced. Both the two- and three-PFMs were used to calculate the effective atomic number and electron density from multiple CT numbers. The mean excitation energy was calculated via parameterisation with the effective atomic number, and the SPR was then calculated from the calculated electron density and mean excitation energy. Then, the SPRs from both methods were compared with the theoretical values. To estimate the noise level of the CT numbers obtained from the photon-counting CT, CT numbers, including noise, were simulated to evaluate the robustness of the aforementioned PFMs. For the aluminium and graphite, the maximum relative errors for the SPRs calculated using the two-PFM and three-PFM were 17.1% and 7.1%, respectively. For the PMMA and biological phantom materials, the maximum relative errors for the SPRs calculated using the two-PFM and three-PFM were 5.5% and 2.0%, respectively. It was concluded that the three-PFM, compared with the two-PFM, can yield SPRs that are closer to the theoretical values and is less affected by noise. - 9 December 2020
- Published by IOP Publishing in Physica Scripta
- Vol. 96 (2) , 025302
Position distribution calculation of annihilation radiations and bremsstrahlung x rays in water during irradiation of positive muons: a Monte Carlo simulation study
Range, momentum and deviation of momentum determinations of muons are important for quality assessment (QA) of beams. Imaging of annihilation radiations emitted from positrons decayed from positive muons and that of bremsstrahlung x-rays emitted from positrons and secondary electrons from positive muons are possible methods of imaging muons. However, the energies and intensities as well as position distributions of these radiations have not been obvious. Thus we calculated the energy spectrum and the distributions of annihilation radiations as well as bremsstrahlung x-rays produced in water during irradiation of positive muons using Monte Carlo simulation. The calculations were conducted for 84.5 MeV /c positive muons, which is the same beam condition used in an experimental facility at the Japan Proton Accelerator Research Complex (J-PARC). We were able to calculate the energy spectrum as well as the position distributions of annihilation radiations and bremsstrahlung x-rays. The energy spectrum showed a broad distribution of bremsstrahlung x-rays, mainly from decayed positrons with an energy range up to 50 MeV with higher intensity in low-energy bremsstrahlung x-rays. The spectrum also showed a sharp peak at 511-keV from annihilation radiations. The position distribution of annihilation radiations was wider than those of the bremsstrahlung x-rays. The position distribution of the bremsstrahlung x-rays were nearly identical to the Cerenkov-light position distribution emitted by the decayed positrons in water. We conclude that imaging of bremsstrahlung x-rays from decayed positrons by using an x-ray camera is a promising method for the QA of positive muons and that higher spatial resolution images of positron distributions will be measured than those measured by annihilation radiations.
- 9 December 2020
- Published by IOP Publishing in Physica Scripta
- Vol. 96 (2) , 025302
Position distribution calculation of annihilation radiations and bremsstrahlung x rays in water during irradiation of positive muons: a Monte Carlo simulation study
Range, momentum and deviation of momentum determinations of muons are important for quality assessment (QA) of beams. Imaging of annihilation radiations emitted from positrons decayed from positive muons and that of bremsstrahlung x-rays emitted from positrons and secondary electrons from positive muons are possible methods of imaging muons. However, the energies and intensities as well as position distributions of these radiations have not been obvious. Thus we calculated the energy spectrum and the distributions of annihilation radiations as well as bremsstrahlung x-rays produced in water during irradiation of positive muons using Monte Carlo simulation. The calculations were conducted for 84.5 MeV /c positive muons, which is the same beam condition used in an experimental facility at the Japan Proton Accelerator Research Complex (J-PARC). We were able to calculate the energy spectrum as well as the position distributions of annihilation radiations and bremsstrahlung x-rays. The energy spectrum showed a broad distribution of bremsstrahlung x-rays, mainly from decayed positrons with an energy range up to 50 MeV with higher intensity in low-energy bremsstrahlung x-rays. The spectrum also showed a sharp peak at 511-keV from annihilation radiations. The position distribution of annihilation radiations was wider than those of the bremsstrahlung x-rays. The position distribution of the bremsstrahlung x-rays were nearly identical to the Cerenkov-light position distribution emitted by the decayed positrons in water. We conclude that imaging of bremsstrahlung x-rays from decayed positrons by using an x-ray camera is a promising method for the QA of positive muons and that higher spatial resolution images of positron distributions will be measured than those measured by annihilation radiations.
- Open Access
- 23 June 2020
- Published by IOP Publishing in Journal of Physics Communications
- Vol. 4 (7) , 075002
Radioluminescence by synchrotron radiation with lower energy than the Cherenkov light threshold in water
Radioluminescence by protons and carbon ions of energy lower than the Cherenkov threshold (∼260 keV) in water has been observed. However, the origin of the luminescence has not been investigated well. In the present work, we imaged radioluminescence in water using synchrotron radiation that was of sufficiently lower energy (11 keV) than the Cherenkov threshold and we measured its spectrum using a high-sensitivity cooled CCD camera and optical longpass filters having 5 different thresholds. In addition, to determine effects of impurities in water, the water target was changed from ultrapure water to tap water. Monte Carlo simulation (Geant4) was also performed to compare its results with the experimentally obtained radioluminescence distribution. In the simulation, photons were generated in proportion to the energy deposition in water. As a result, the beam trajectory was clearly imaged by the radioluminescence in water. The spectrum was proportional to λ −3.4±0.4 under an assumption of no peaks. In the spectrum and distribution, no differences were observed between ultrapure water and tap water. TOC (total organic carbon) contents of ultrapure water and tap water as an impurity were measured and these were 0.26 mg l−1 and 2.3 mg l−1, respectively. The radioluminescence seemed to be attributable to water molecules not impurities. The radioluminescence distribution of the simulation was consistent with the experimental distribution and this suggested that radioluminescence was proportional to dose, which is expected to allow use for dose measurement.
- 23 June 2020
- Published by IOP Publishing in Journal of Physics Communications
- Vol. 4 (7) , 075002
Open AccessRadioluminescence by synchrotron radiation with lower energy than the Cherenkov light threshold in water
Radioluminescence by protons and carbon ions of energy lower than the Cherenkov threshold (∼260 keV) in water has been observed. However, the origin of the luminescence has not been investigated well. In the present work, we imaged radioluminescence in water using synchrotron radiation that was of sufficiently lower energy (11 keV) than the Cherenkov threshold and we measured its spectrum using a high-sensitivity cooled CCD camera and optical longpass filters having 5 different thresholds. In addition, to determine effects of impurities in water, the water target was changed from ultrapure water to tap water. Monte Carlo simulation (Geant4) was also performed to compare its results with the experimentally obtained radioluminescence distribution. In the simulation, photons were generated in proportion to the energy deposition in water. As a result, the beam trajectory was clearly imaged by the radioluminescence in water. The spectrum was proportional to λ −3.4±0.4 under an assumption of no peaks. In the spectrum and distribution, no differences were observed between ultrapure water and tap water. TOC (total organic carbon) contents of ultrapure water and tap water as an impurity were measured and these were 0.26 mg l−1 and 2.3 mg l−1, respectively. The radioluminescence seemed to be attributable to water molecules not impurities. The radioluminescence distribution of the simulation was consistent with the experimental distribution and this suggested that radioluminescence was proportional to dose, which is expected to allow use for dose measurement.
- 9 November 2019
- Published by Wiley in Medical Physics
- Vol. 47 (2) , 781-789
Estimations of relative biological effectiveness of secondary fragments in carbon ion irradiation of water using CR‐39 plastic detector and microdosimetric kinetic model
Purpose: To estimate relative biological effectiveness (RBE) ascribed to secondary fragments in a lateral distribution of carbon ion irradiation. The RBE was estimated with the microdosimetric kinetic (MK) model and measured linear energy transfer (LET) obtained with CR‐39 plastic detectors.Methods: A water phantom was irradiated by a 12C pencil beam with energy of 380 MeV/u at the Gunma University Heavy Ion Medical Center (GHMC), and CR‐39 detectors were exposed to secondary fragments. Because CR‐39 was insensitive to low LET, we conducted Monte Carlo simulations with Geant4 to calculate low LET particles. The spectra of low LET particles were combined with experimental spectra to calculate RBE. To estimate accuracy of RBE, we calculated RBE by changing yield of low LET particles by ± 10% and ± 40%.Results: At a small angle, maximum RBE by secondary fragments was 1.3 for 10% survival fractions. RBE values of fragments gradually decreased as the angle became larger. The shape of the LET spectra in the simulation reproduced the experimental spectra, but there was a discrepancy between the simulation and experiment for the relative yield of fragments. When the yield of low LET particles was changed by ± 40%, the change in RBE was smaller than 10%.Conclusions: An RBE of 1.3 was expected for secondary fragments emitted at a small angle. Although, we observed a discrepancy in the relative yield of secondary fragments between simulation and experiment, precision of RBE was not so sensitive to the yield of low LET particles.
- 9 November 2019
- Published by Wiley in Medical Physics
- Vol. 47 (2) , 781-789
Estimations of relative biological effectiveness of secondary fragments in carbon ion irradiation of water using CR‐39 plastic detector and microdosimetric kinetic model
Purpose: To estimate relative biological effectiveness (RBE) ascribed to secondary fragments in a lateral distribution of carbon ion irradiation. The RBE was estimated with the microdosimetric kinetic (MK) model and measured linear energy transfer (LET) obtained with CR‐39 plastic detectors.Methods: A water phantom was irradiated by a 12C pencil beam with energy of 380 MeV/u at the Gunma University Heavy Ion Medical Center (GHMC), and CR‐39 detectors were exposed to secondary fragments. Because CR‐39 was insensitive to low LET, we conducted Monte Carlo simulations with Geant4 to calculate low LET particles. The spectra of low LET particles were combined with experimental spectra to calculate RBE. To estimate accuracy of RBE, we calculated RBE by changing yield of low LET particles by ± 10% and ± 40%.Results: At a small angle, maximum RBE by secondary fragments was 1.3 for 10% survival fractions. RBE values of fragments gradually decreased as the angle became larger. The shape of the LET spectra in the simulation reproduced the experimental spectra, but there was a discrepancy between the simulation and experiment for the relative yield of fragments. When the yield of low LET particles was changed by ± 40%, the change in RBE was smaller than 10%.Conclusions: An RBE of 1.3 was expected for secondary fragments emitted at a small angle. Although, we observed a discrepancy in the relative yield of secondary fragments between simulation and experiment, precision of RBE was not so sensitive to the yield of low LET particles.
- 1 September 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (18) , 185006
Linear energy transfer (LET) spectra and survival fraction distribution based on the CR-39 plastic charged-particle detector in a spread-out Bragg peak irradiation by a 12 C beam
Facilities for heavy ion therapies are steadily increasing in number worldwide. One of the advantages of heavy ions is their high relative biological effect (RBE). In a model used at NIRS (National Institute of Radiological Sciences), linear energy transfer (LET) spectra are required to estimate biological dose (physical dose × RBE). The CR-39 plastic charged-particle detector (CR-39) is suitable for measurement of LET. For the present study, done at the Gunma University Heavy Ion Medical Center (GHMC), we measured LET spectra at 11 depths in spread-out Bragg peak (SOBP) irradiation by a 12 C beam of 380 MeV/u. The lower threshold of the CR-39 to measure LET was about 5 keV µ m −1 due to poor sensitivity for low LET. Then we calculated biological dose and survival fraction distributions and compared them with treatment planning results at GHMC. We used Monte Carlo simulation (Geant4) to calculate LET spectra. The simulation results were in good agreement with the experimental spectra. Moreover, the biological dose and survival fraction distributions estimated from the CR-39 reproduced the treatment planning. The CR-39 is suitable for estimating biological dose in carbon ion therapy.
- 1 September 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (18) , 185006
Linear energy transfer (LET) spectra and survival fraction distribution based on the CR-39 plastic charged-particle detector in a spread-out Bragg peak irradiation by a 12 C beam
Facilities for heavy ion therapies are steadily increasing in number worldwide. One of the advantages of heavy ions is their high relative biological effect (RBE). In a model used at NIRS (National Institute of Radiological Sciences), linear energy transfer (LET) spectra are required to estimate biological dose (physical dose × RBE). The CR-39 plastic charged-particle detector (CR-39) is suitable for measurement of LET. For the present study, done at the Gunma University Heavy Ion Medical Center (GHMC), we measured LET spectra at 11 depths in spread-out Bragg peak (SOBP) irradiation by a 12 C beam of 380 MeV/u. The lower threshold of the CR-39 to measure LET was about 5 keV µ m −1 due to poor sensitivity for low LET. Then we calculated biological dose and survival fraction distributions and compared them with treatment planning results at GHMC. We used Monte Carlo simulation (Geant4) to calculate LET spectra. The simulation results were in good agreement with the experimental spectra. Moreover, the biological dose and survival fraction distributions estimated from the CR-39 reproduced the treatment planning. The CR-39 is suitable for estimating biological dose in carbon ion therapy.