Irfan Aditya Dharma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Irfan Aditya Dharma has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Adhika Widyaparaga
Department of Mechanical and Industrial Engineering, Faculty of Engineering, Universitas Gadjah Mada, Yogyakarta, Indonesia
2 shared publications - Daisuke Kawashima
Graduate School of Engineering, Chiba University
2 shared publications - Indro Pranoto
Universitas Gadjah Mada
2 shared publications - Khasani
Department of Mechanical and Industrial Engineering, Faculty of Engineering, Universitas Gadjah Mada, Yogyakarta 55281, Indonesia
2 shared publications - Marlin Ramadhan Baidillah
Research Center for Electronics, National Research and Innovation Agency, KST Samaun Samadikun, Bandung 40135, Indonesia
2 shared publications - Masahiro Takei
Graduate School of Engineering, Chiba University
2 shared publications
Latest Publications
- 9 June 2021
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 7 (4) , 045019
In-vivo viscoelastic properties estimation in subcutaneous adipose tissue by integration of poroviscoelastic-mass transport model (pve-MTM) into wearable electrical impedance tomography (w-EIT)
In-vivo viscoelastic properties have been estimated in human subcutaneous adipose tissue (SAT) by integration of poroviscoelastic-mass transport model ( pve -MTM) into wearable electrical impedance tomography ( w -EIT) under the influence of external compressive pressure − P . The pve -MTM predicts the ion concentration distribution c m o d ( t ) by coupling the poroviscoelastic and mass transport model to describe the hydrodynamics, rheology, and transport phenomena inside SAT. The w -EIT measures the time-difference conductivity distribution ∆ γ ( t ) in SAT resulted from the ion transport. Based on the integration, the two viscoelastic properties which are viscoelastic shear modulus of SAT G v and relaxation time of SAT τ v are estimated by applying an iterative curve-fitting between the normalized average ion concentration distribution c ˆ m o d ( t ) predicted from pve -MTM and the experimental normalized average ion concentration distribution c ˆ exp ( t ) derived from w -EIT. The in-vivo experiments were conducted by applying external compressive pressure − P on human calf boundary to induce interstitial fluid flow and ion movement in SAT. As a result, the value of G v was range from 4.9–6.3 kPa and the value of τ v was range from 27.50–38.5 s with the value of average goodness-of-fit curve fitting R 2 > 0.76. These values of G v and τ v were compared to the human and animal tissue from the literature in order to verify this method. The results from pve -MTM provide evidence that G v and τ v play a role in the predicted value of c ˆ m o d .
- 9 June 2021
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 7 (4) , 045019
In-vivo viscoelastic properties estimation in subcutaneous adipose tissue by integration of poroviscoelastic-mass transport model (pve-MTM) into wearable electrical impedance tomography (w-EIT)
In-vivo viscoelastic properties have been estimated in human subcutaneous adipose tissue (SAT) by integration of poroviscoelastic-mass transport model ( pve -MTM) into wearable electrical impedance tomography ( w -EIT) under the influence of external compressive pressure − P . The pve -MTM predicts the ion concentration distribution c m o d ( t ) by coupling the poroviscoelastic and mass transport model to describe the hydrodynamics, rheology, and transport phenomena inside SAT. The w -EIT measures the time-difference conductivity distribution ∆ γ ( t ) in SAT resulted from the ion transport. Based on the integration, the two viscoelastic properties which are viscoelastic shear modulus of SAT G v and relaxation time of SAT τ v are estimated by applying an iterative curve-fitting between the normalized average ion concentration distribution c ˆ m o d ( t ) predicted from pve -MTM and the experimental normalized average ion concentration distribution c ˆ exp ( t ) derived from w -EIT. The in-vivo experiments were conducted by applying external compressive pressure − P on human calf boundary to induce interstitial fluid flow and ion movement in SAT. As a result, the value of G v was range from 4.9–6.3 kPa and the value of τ v was range from 27.50–38.5 s with the value of average goodness-of-fit curve fitting R 2 > 0.76. These values of G v and τ v were compared to the human and animal tissue from the literature in order to verify this method. The results from pve -MTM provide evidence that G v and τ v play a role in the predicted value of c ˆ m o d .
- 24 March 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (5) , 055701
Albumin diffusivity coefficient estimation in imitated porous structure of interstitial space by integration of albumin diffusion model (ADM) to electrical impedance tomography (EIT)
Albumin diffusivity coefficient D I a in imitated porous structure of interstitial space has been estimated by means of the integration of albumin diffusion model (ADM) to electrical impedance tomography (EIT) (iADM-EIT) under five different porosity ϕ conditions (from ϕ 1 = 0.922 to ϕ 5 = 0.990) for transport phenomena quantification. The iADM-EIT was conducted by applying an iterative curve-fitting between spatio-temporal albumin concentration C I a derived from ADM and spatio-temporal distribution of conductivity difference Δ σ reconstructed by EIT. The essential point of the iADM-EIT is the quantification of experimental C I ex a from Δ σ by establishing a constitutive relationship among C I ex a , Δ σ , and ϕ . ADM is developed based on Fick’s second law implemented in Krogh tissue cylinder. EIT is performed to image the Δ σ caused by increase of C I a due to albumin diffusion phenomenon from a capillary to the imitated porous structure. The imitated porous structure is manufactured with agarose gel in a dynamic phantom including a capillary. As a result, the relative albumin diffusivity coefficient D I a / D 0 a ( D 0 a : free diffusivity of albumin coefficient) is increased with the increase of ϕ in the range from 0.271 to 0.694, which are correspondent to the literature data with percent average relative error δ = 6.83 ± 2.72%.
- 24 March 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (5) , 055701
Albumin diffusivity coefficient estimation in imitated porous structure of interstitial space by integration of albumin diffusion model (ADM) to electrical impedance tomography (EIT)
Albumin diffusivity coefficient D I a in imitated porous structure of interstitial space has been estimated by means of the integration of albumin diffusion model (ADM) to electrical impedance tomography (EIT) (iADM-EIT) under five different porosity ϕ conditions (from ϕ 1 = 0.922 to ϕ 5 = 0.990) for transport phenomena quantification. The iADM-EIT was conducted by applying an iterative curve-fitting between spatio-temporal albumin concentration C I a derived from ADM and spatio-temporal distribution of conductivity difference Δ σ reconstructed by EIT. The essential point of the iADM-EIT is the quantification of experimental C I ex a from Δ σ by establishing a constitutive relationship among C I ex a , Δ σ , and ϕ . ADM is developed based on Fick’s second law implemented in Krogh tissue cylinder. EIT is performed to image the Δ σ caused by increase of C I a due to albumin diffusion phenomenon from a capillary to the imitated porous structure. The imitated porous structure is manufactured with agarose gel in a dynamic phantom including a capillary. As a result, the relative albumin diffusivity coefficient D I a / D 0 a ( D 0 a : free diffusivity of albumin coefficient) is increased with the increase of ϕ in the range from 0.271 to 0.694, which are correspondent to the literature data with percent average relative error δ = 6.83 ± 2.72%.
- 1 January 2020
- Published by AIP Publishing
- Vol. 2248, 030003
A 2-D CFD model of albumin-rich-fluid distribution in human subcutaneous tissue for early stage of Lymphedema prediction
- 1 January 2020
- Published by AIP Publishing
- Vol. 2248, 030003
A 2-D CFD model of albumin-rich-fluid distribution in human subcutaneous tissue for early stage of Lymphedema prediction
- Open Access
- 1 May 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 532 (1) , 012002
Performance Evaluation of a Liquid-Liquid Cylindrical Cyclone (LLCC) for Oil-Water Separation
In this experimental study, the type of Hydrocyclone Separators that used is Liquid-Liquid Cylindrical Cyclone (LLCC). The objective of this experimental study is to understand the influences of operating and design parameters such as inlet velocity, split-ratio, and vortex finder diameter towards the result of separation process (LLCC's performance). The separation performance of LLCC is determined by measuring the watercut that goes through the lower output called as underflow. The examined inlet mixture velocity in this experimental study are 1 m/s and 1.2 m/s with split-ratio variation of 5%, 15%, 30%, 45%, 60%, 75%, and 90%. The diameters of vortex finder that used in this experimental study are 18 mm, 22 mm, and 27 mm. All variables are tested under a constant inlet oil volume fraction 25%. From the experiment with those various variables, LLCC can achieve 99% of watercut with different Optimum Split Ratio (OSR) for each inlet mixture velocity and vortex finder diameter.
- 1 May 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 532 (1) , 012002
Open AccessPerformance Evaluation of a Liquid-Liquid Cylindrical Cyclone (LLCC) for Oil-Water Separation
In this experimental study, the type of Hydrocyclone Separators that used is Liquid-Liquid Cylindrical Cyclone (LLCC). The objective of this experimental study is to understand the influences of operating and design parameters such as inlet velocity, split-ratio, and vortex finder diameter towards the result of separation process (LLCC's performance). The separation performance of LLCC is determined by measuring the watercut that goes through the lower output called as underflow. The examined inlet mixture velocity in this experimental study are 1 m/s and 1.2 m/s with split-ratio variation of 5%, 15%, 30%, 45%, 60%, 75%, and 90%. The diameters of vortex finder that used in this experimental study are 18 mm, 22 mm, and 27 mm. All variables are tested under a constant inlet oil volume fraction 25%. From the experiment with those various variables, LLCC can achieve 99% of watercut with different Optimum Split Ratio (OSR) for each inlet mixture velocity and vortex finder diameter.
- 16 August 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2001 (1) , 030001
Visualization study on oil-water separation phenomena in a liquid-liquid cylindrical cyclone (LLCC) separator
This study aims to understand the mechanism of oil-water separation process inside Liquid-Liquid Cylindrical Cyclone (LLCC) and the effect of operating parameters to the separation characteristics. Some experimental runs have been designed and commissioned, then the results from both experiments and visualization data are presented. General characteristics of separation process and flow behavior in the LLCC were explained in the form of qualitative observation and quantitative explanation. For the experimental runs, the LLCC was tested under the wide range of operating parameters such as inlet mixture velocity, split-ratio, and different inlet oil volumetric concentration. The acquired data includ e overflow oil volume fraction.
- 16 August 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2001 (1) , 030001
Visualization study on oil-water separation phenomena in a liquid-liquid cylindrical cyclone (LLCC) separator
This study aims to understand the mechanism of oil-water separation process inside Liquid-Liquid Cylindrical Cyclone (LLCC) and the effect of operating parameters to the separation characteristics. Some experimental runs have been designed and commissioned, then the results from both experiments and visualization data are presented. General characteristics of separation process and flow behavior in the LLCC were explained in the form of qualitative observation and quantitative explanation. For the experimental runs, the LLCC was tested under the wide range of operating parameters such as inlet mixture velocity, split-ratio, and different inlet oil volumetric concentration. The acquired data includ e overflow oil volume fraction.
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1737 (1) , 040013
Development of liquid-liquid cylindrical cyclone (LLCC) separator for oil-water separation
This study aims to determine the phenomena of water and oil separation and the performance of the Liquid-Liquid Cylindrical Cyclone (LLCC). The experiments were conducted with water and oil in a transparent LLCC separator that allows the visualization of the mixture. Series of experiments for various of inlet mixture velocity (Vm), inlet oil volume fraction (α), and split-ratio have been performed. Volume fraction of oil in the inlet were 0.06 (6 %), 0.1 (10%), and 0.15 (15 %). The examined inlet mixture velocity variations were 1.0 m / s, 1.5 m / s, and 2.0 m / s. Split-ratio was made in the range 25-70 %. The watercut in underflow were the variables measured. The experimental results show that the LLCC was able to separate water and oil and produced free water with concentration up to 98%. By increasing the value of the split-ratio, watercut in underflow increase and reached the optimum point. Optimal split-ratio observed is between 60 % and 70 % depend on the inlet oil volume fraction.
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1737 (1) , 040013
Development of liquid-liquid cylindrical cyclone (LLCC) separator for oil-water separation
This study aims to determine the phenomena of water and oil separation and the performance of the Liquid-Liquid Cylindrical Cyclone (LLCC). The experiments were conducted with water and oil in a transparent LLCC separator that allows the visualization of the mixture. Series of experiments for various of inlet mixture velocity (Vm), inlet oil volume fraction (α), and split-ratio have been performed. Volume fraction of oil in the inlet were 0.06 (6 %), 0.1 (10%), and 0.15 (15 %). The examined inlet mixture velocity variations were 1.0 m / s, 1.5 m / s, and 2.0 m / s. Split-ratio was made in the range 25-70 %. The watercut in underflow were the variables measured. The experimental results show that the LLCC was able to separate water and oil and produced free water with concentration up to 98%. By increasing the value of the split-ratio, watercut in underflow increase and reached the optimum point. Optimal split-ratio observed is between 60 % and 70 % depend on the inlet oil volume fraction.