IDIrfan Aditya Dharma

Irfan Aditya Dharma

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Irfan Aditya Dharma has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • In-vivo viscoelastic properties estimation in subcutaneous adipose tissue by integration of poroviscoelastic-mass transport model (pve-MTM) into wearable electrical impedance tomography (w-EIT)

    by Irfan Aditya Dharma, Daisuke Kawashima, Marlin Ramadhan Baidillah, Panji Nursetia Darma, Masahiro Takei

    In-vivo viscoelastic properties have been estimated in human subcutaneous adipose tissue (SAT) by integration of poroviscoelastic-mass transport model ( pve -MTM) into wearable electrical impedance tomography ( w -EIT) under the influence of external compressive pressure − P . The pve -MTM predicts the ion concentration distribution c m o d ( t ) by coupling the poroviscoelastic and mass transport model to describe the hydrodynamics, rheology, and transport phenomena inside SAT. The w -EIT measures the time-difference conductivity distribution ∆ γ ( t ) in SAT resulted from the ion transport. Based on the integration, the two viscoelastic properties which are viscoelastic shear modulus of SAT G v and relaxation time of SAT τ v are estimated by applying an iterative curve-fitting between the normalized average ion concentration distribution c ˆ m o d ( t ) predicted from pve -MTM and the experimental normalized average ion concentration distribution c ˆ exp ( t ) derived from w -EIT. The in-vivo experiments were conducted by applying external compressive pressure − P on human calf boundary to induce interstitial fluid flow and ion movement in SAT. As a result, the value of G v was range from 4.9–6.3 kPa and the value of τ v was range from 27.50–38.5 s with the value of average goodness-of-fit curve fitting R 2 > 0.76. These values of G v and τ v were compared to the human and animal tissue from the literature in order to verify this method. The results from pve -MTM provide evidence that G v and τ v play a role in the predicted value of c ˆ m o d .


  • Albumin diffusivity coefficient estimation in imitated porous structure of interstitial space by integration of albumin diffusion model (ADM) to electrical impedance tomography (EIT)

    by Irfan Aditya Aditya Dharma, Daisuke Kawashima, Marlin Ramadhan Baidillah, Panji Nursetia Darma, Masahiro Takei

    Albumin diffusivity coefficient D I a in imitated porous structure of interstitial space has been estimated by means of the integration of albumin diffusion model (ADM) to electrical impedance tomography (EIT) (iADM-EIT) under five different porosity ϕ conditions (from ϕ 1 = 0.922 to ϕ 5 = 0.990) for transport phenomena quantification. The iADM-EIT was conducted by applying an iterative curve-fitting between spatio-temporal albumin concentration C I a derived from ADM and spatio-temporal distribution of conductivity difference Δ σ reconstructed by EIT. The essential point of the iADM-EIT is the quantification of experimental C I ex a from Δ σ by establishing a constitutive relationship among C I ex a , Δ σ , and ϕ . ADM is developed based on Fick’s second law implemented in Krogh tissue cylinder. EIT is performed to image the Δ σ caused by increase of C I a due to albumin diffusion phenomenon from a capillary to the imitated porous structure. The imitated porous structure is manufactured with agarose gel in a dynamic phantom including a capillary. As a result, the relative albumin diffusivity coefficient D I a / D 0 a ( D 0 a : free diffusivity of albumin coefficient) is increased with the increase of ϕ in the range from 0.271 to 0.694, which are correspondent to the literature data with percent average relative error δ = 6.83 ± 2.72%.


  • A 2-D CFD model of albumin-rich-fluid distribution in human subcutaneous tissue for early stage of Lymphedema prediction

    by Irfan Aditya Dharma, Marlin Ramadhan Baidillah, Michiko Sugawara, Masahiro Takei

  • Open Access

    Performance Evaluation of a Liquid-Liquid Cylindrical Cyclone (LLCC) for Oil-Water Separation

    by I A Dharma, A Widyaparaga, F I Faza

    In this experimental study, the type of Hydrocyclone Separators that used is Liquid-Liquid Cylindrical Cyclone (LLCC). The objective of this experimental study is to understand the influences of operating and design parameters such as inlet velocity, split-ratio, and vortex finder diameter towards the result of separation process (LLCC's performance). The separation performance of LLCC is determined by measuring the watercut that goes through the lower output called as underflow. The examined inlet mixture velocity in this experimental study are 1 m/s and 1.2 m/s with split-ratio variation of 5%, 15%, 30%, 45%, 60%, 75%, and 90%. The diameters of vortex finder that used in this experimental study are 18 mm, 22 mm, and 27 mm. All variables are tested under a constant inlet oil volume fraction 25%. From the experiment with those various variables, LLCC can achieve 99% of watercut with different Optimum Split Ratio (OSR) for each inlet mixture velocity and vortex finder diameter.


  • Visualization study on oil-water separation phenomena in a liquid-liquid cylindrical cyclone (LLCC) separator

    by Irfan Aditya Dharma, Adhika Widyaparaga, Indro Pranoto, Khasani

    This study aims to understand the mechanism of oil-water separation process inside Liquid-Liquid Cylindrical Cyclone (LLCC) and the effect of operating parameters to the separation characteristics. Some experimental runs have been designed and commissioned, then the results from both experiments and visualization data are presented. General characteristics of separation process and flow behavior in the LLCC were explained in the form of qualitative observation and quantitative explanation. For the experimental runs, the LLCC was tested under the wide range of operating parameters such as inlet mixture velocity, split-ratio, and different inlet oil volumetric concentration. The acquired data includ e overflow oil volume fraction.

  • Development of liquid-liquid cylindrical cyclone (LLCC) separator for oil-water separation

    by Irfan Aditya Dharma, Fuad Arffan, Anggi Riyo Prambudi, Adhika Widyaparaga, Indro Pranoto, Khasani

    This study aims to determine the phenomena of water and oil separation and the performance of the Liquid-Liquid Cylindrical Cyclone (LLCC). The experiments were conducted with water and oil in a transparent LLCC separator that allows the visualization of the mixture. Series of experiments for various of inlet mixture velocity (Vm), inlet oil volume fraction (α), and split-ratio have been performed. Volume fraction of oil in the inlet were 0.06 (6 %), 0.1 (10%), and 0.15 (15 %). The examined inlet mixture velocity variations were 1.0 m / s, 1.5 m / s, and 2.0 m / s. Split-ratio was made in the range 25-70 %. The watercut in underflow were the variables measured. The experimental results show that the LLCC was able to separate water and oil and produced free water with concentration up to 98%. By increasing the value of the split-ratio, watercut in underflow increase and reached the optimum point. Optimal split-ratio observed is between 60 % and 70 % depend on the inlet oil volume fraction.