Jitka Komrsková
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jitka Komrsková has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Antonín Jabor
Department of Laboratory Methods, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
3 shared publications - Janka Franeková
Department of Laboratory Methods, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
3 shared publications A Jabor
2 shared publicationsJ Franeková
2 shared publications- Jiří Vymětalík
Department of Laboratory Methods, Institute for Clinical and Experimental Medicine, Vídeňská 1958/9, 140 21 Prague 4, Czech Republic
2 shared publications - Aleš Březina
Department of Anesthesiology and Resuscitation, Institute for Clinical and Experimental Medicine, Vídeňská 1958/9, 140 21 Prague 4, Czech Republic
1 shared publication
Latest Publications
- Open Access
- 14 March 2023
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 37 (5)
Significant elevations of serum amylase caused by macroamylase: Case reports and detection possibilities
Background: The presence of isolated elevated serum amylase levels can be caused by high molecular mass complexes. We describe 13 cases of hyperamylasemia detected in adult patients without clinical symptoms of a pancreatic disorder. Five of them were thoroughly examined using different tools for the detection of macrocomplexes.Methods: We performed both screening and more advanced methods of macroamylase detection, including polyethylene glycol precipitation, sample storage at 4°C and separation by gel filtration.Results: The presence of macroamylase in the suspected samples was confirmed by the methods described, except for the sample storage at 4°C. In this method, the enzyme activity did not decrease. The polyethylene glycol precipitation activity (% PPA) averaged 89.1% for amylase, whereas the control samples averaged 30.7%. Gel filtration chromatography confirmed an IgA macroamylase peak in three samples and an IgG macroamylase peak in two samples.Conclusion: The presence of macroamylase should be suspected whenever the clinical history and condition of the patient do not match the measured enzyme value to avoid diagnostic errors and unnecessary invasive examinations. The presence of macrocomplexes is considered a benign process that may occur in apparently healthy individuals. Cooperation between clinicians and laboratory staff is necessary.
- 14 March 2023
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 37 (5)
Open AccessSignificant elevations of serum amylase caused by macroamylase: Case reports and detection possibilities
Background: The presence of isolated elevated serum amylase levels can be caused by high molecular mass complexes. We describe 13 cases of hyperamylasemia detected in adult patients without clinical symptoms of a pancreatic disorder. Five of them were thoroughly examined using different tools for the detection of macrocomplexes.Methods: We performed both screening and more advanced methods of macroamylase detection, including polyethylene glycol precipitation, sample storage at 4°C and separation by gel filtration.Results: The presence of macroamylase in the suspected samples was confirmed by the methods described, except for the sample storage at 4°C. In this method, the enzyme activity did not decrease. The polyethylene glycol precipitation activity (% PPA) averaged 89.1% for amylase, whereas the control samples averaged 30.7%. Gel filtration chromatography confirmed an IgA macroamylase peak in three samples and an IgG macroamylase peak in two samples.Conclusion: The presence of macroamylase should be suspected whenever the clinical history and condition of the patient do not match the measured enzyme value to avoid diagnostic errors and unnecessary invasive examinations. The presence of macrocomplexes is considered a benign process that may occur in apparently healthy individuals. Cooperation between clinicians and laboratory staff is necessary.
- Open Access
- 6 January 2021
- Published by Wiley in Mediators of Inflammation
- Vol. 2021 (1)
Changes in Sepsis Biomarkers after Immunosuppressant Administration in Transplant Patients
Sepsis biomarkers change continuously during the postoperative period. We aimed to demonstrate the influence of immunosuppressants after transplantation (Tx) on presepsin, procalcitonin, CRP, white blood cells, and IL‐6. A group of 140 patients after major surgery (86 non‐Tx, 54 Tx) without any signs of sepsis or infectious complications was followed for 7 days. The changes in biomarkers were analyzed with respect to the type of surgery, organ, and induction immunosuppressant used (antithymocyte globulin, corticosteroids, or basiliximab/rituximab). Concentrations (95th percentiles) of presepsin and procalcitonin were higher in the Tx group (presepsin: Tx < 2380 vs. non‐Tx < 1368 ng/L, p < 0.05; procalcitonin: μg/L, p < 0.05). In contrast, CRP and IL‐6 were lower in the Tx group (CRP: Tx < 84.2 vs. non‐Tx < 229 mg/L, p < 0.05; IL‐6: p < 0.05). Decreases in CRP and IL‐6 were found for all immunosuppressants, and procalcitonin was increased after antithymocyte globulin and corticosteroids. Negligible changes were found for white blood cells. Different responses of presepsin, procalcitonin, CRP, and IL‐6 were therefore found in patients without any infectious complications after major surgery or transplantation. Immunosuppression decreased significantly IL‐6 and CRP in comparison to non‐Tx patients, while procalcitonin was increased after corticosteroids and antithymocyte globulin only. Cautious interpretation of sepsis biomarkers is needed in the early posttransplant period. This work was conducted as a noninterventional (nonregistered) study.
- 6 January 2021
- Published by Wiley in Mediators of Inflammation
- Vol. 2021 (1)
Open AccessChanges in Sepsis Biomarkers after Immunosuppressant Administration in Transplant Patients
Sepsis biomarkers change continuously during the postoperative period. We aimed to demonstrate the influence of immunosuppressants after transplantation (Tx) on presepsin, procalcitonin, CRP, white blood cells, and IL‐6. A group of 140 patients after major surgery (86 non‐Tx, 54 Tx) without any signs of sepsis or infectious complications was followed for 7 days. The changes in biomarkers were analyzed with respect to the type of surgery, organ, and induction immunosuppressant used (antithymocyte globulin, corticosteroids, or basiliximab/rituximab). Concentrations (95th percentiles) of presepsin and procalcitonin were higher in the Tx group (presepsin: Tx < 2380 vs. non‐Tx < 1368 ng/L, p < 0.05; procalcitonin: μg/L, p < 0.05). In contrast, CRP and IL‐6 were lower in the Tx group (CRP: Tx < 84.2 vs. non‐Tx < 229 mg/L, p < 0.05; IL‐6: p < 0.05). Decreases in CRP and IL‐6 were found for all immunosuppressants, and procalcitonin was increased after antithymocyte globulin and corticosteroids. Negligible changes were found for white blood cells. Different responses of presepsin, procalcitonin, CRP, and IL‐6 were therefore found in patients without any infectious complications after major surgery or transplantation. Immunosuppression decreased significantly IL‐6 and CRP in comparison to non‐Tx patients, while procalcitonin was increased after corticosteroids and antithymocyte globulin only. Cautious interpretation of sepsis biomarkers is needed in the early posttransplant period. This work was conducted as a noninterventional (nonregistered) study.
- Open Access
- 1 December 2019
- Published by Česká lékařská společnost Jana Evangelisty Purkyně, z.s. in Klinická biochemie a metabolismus
- Vol. 27 (4) , 172-176
Macro-complexes and possibilities of their detection
C?l studie: Zpracov?n? aktu?ln?ch znalost? o klinick? problematice makro-komplex? a mo?nostech jejich detekce.Typ studie: P?ehledn? pr?ce.N?zev a s?dlo pracovi?t?: Institut klinick? a experiment?ln? medic?ny, V?de?sk? 1958/9, 140 21 Praha 4.Ma... C?l studie: Zpracov?n? aktu?ln?ch znalost? o klinick? problematice makro-komplex? a mo?nostech jejich detekce.Typ studie: P?ehledn? pr?ce.N?zev a s?dlo pracovi?t?: Institut klinick? a experiment?ln? medic?ny, V?de?sk? 1958/9, 140 21 Praha 4.Ma...
- 1 December 2019
- Published by Česká lékařská společnost Jana Evangelisty Purkyně, z.s. in Klinická biochemie a metabolismus
- Vol. 27 (4) , 172-176
Open AccessMacro-complexes and possibilities of their detection
C?l studie: Zpracov?n? aktu?ln?ch znalost? o klinick? problematice makro-komplex? a mo?nostech jejich detekce.Typ studie: P?ehledn? pr?ce.N?zev a s?dlo pracovi?t?: Institut klinick? a experiment?ln? medic?ny, V?de?sk? 1958/9, 140 21 Praha 4.Ma... C?l studie: Zpracov?n? aktu?ln?ch znalost? o klinick? problematice makro-komplex? a mo?nostech jejich detekce.Typ studie: P?ehledn? pr?ce.N?zev a s?dlo pracovi?t?: Institut klinick? a experiment?ln? medic?ny, V?de?sk? 1958/9, 140 21 Praha 4.Ma...
- Open Access
- 1 December 2018
- Published by Česká lékařská společnost Jana Evangelisty Purkyně, z.s. in Klinická biochemie a metabolismus
- Vol. 26 (4) , 173-177
Hemolysis index as a tool for determination of free hemoglobin in plasma
C?l studie: Zaveden? laboratorn?ho vy?et?en? voln?ho hemoglobinu v plazm? do rutinn?ho provozu laborato?e pomoc? v?po?tov? metody zalo?en? na hodnot? hemolytick?ho indexu (HI), kter? m??e b?t k dispozici klinick?m odd?len?m po 24 hodin denn?. ... C?l studie: Zaveden? laboratorn?ho vy?et?en? voln?ho hemoglobinu v plazm? do rutinn?ho provozu laborato?e pomoc? v?po?tov? metody zalo?en? na hodnot? hemolytick?ho indexu (HI), kter? m??e b?t k dispozici klinick?m odd?len?m po 24 hodin denn?. ...
- 1 December 2018
- Published by Česká lékařská společnost Jana Evangelisty Purkyně, z.s. in Klinická biochemie a metabolismus
- Vol. 26 (4) , 173-177
Open AccessHemolysis index as a tool for determination of free hemoglobin in plasma
C?l studie: Zaveden? laboratorn?ho vy?et?en? voln?ho hemoglobinu v plazm? do rutinn?ho provozu laborato?e pomoc? v?po?tov? metody zalo?en? na hodnot? hemolytick?ho indexu (HI), kter? m??e b?t k dispozici klinick?m odd?len?m po 24 hodin denn?. ... C?l studie: Zaveden? laboratorn?ho vy?et?en? voln?ho hemoglobinu v plazm? do rutinn?ho provozu laborato?e pomoc? v?po?tov? metody zalo?en? na hodnot? hemolytick?ho indexu (HI), kter? m??e b?t k dispozici klinick?m odd?len?m po 24 hodin denn?. ...
- 1 November 2018
- Published by Elsevier in Clinica Chimica Acta
- Vol. 486, 311-312
Within-subject biological variation of pairs of heavy/light immunoglobulin IgM chains (HLC IgM κ and λ) is low and requires monitoring: A comparison with HLC IgA, HLC IgG, and free light immunoglobulin chains (FLC) in healthy subjects
- 1 November 2018
- Published by Elsevier in Clinica Chimica Acta
- Vol. 486, 311-312
Within-subject biological variation of pairs of heavy/light immunoglobulin IgM chains (HLC IgM κ and λ) is low and requires monitoring: A comparison with HLC IgA, HLC IgG, and free light immunoglobulin chains (FLC) in healthy subjects