Keiko Ishii
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Keiko Ishii has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Koji Fumoto
Department of Mechanical Engineering, Aoyama Gakuin University, Sagamihara, Japan
6 shared publications Koji Okamoto
4 shared publicationsYanrong Li
4 shared publicationsKaoru Tominaga
3 shared publicationsMasayuki Saeki
Tokyo University of Science
3 shared publicationsMitsunori Uchida
3 shared publications
Latest Publications
- Open Access
- 7 March 2026
- Published by Elsevier in International Journal of Thermofluids
- Vol. 33
Clustering of magnetic microcapsules in forced convection: Effects of temperature
- 7 March 2026
- Published by Elsevier in International Journal of Thermofluids
- Vol. 33
Open AccessClustering of magnetic microcapsules in forced convection: Effects of temperature
- Open Access
- 6 February 2026
- Published by Elsevier in SSRN Electronic Journal
Development of a Two-color Microparticle Method for Simultaneous Temperature and Velocity Field Measurement
In recent years, the importance of simultaneous measurement techniques for temperature and velocity fields in strongly coupled thermo-fluid flows has increased due to the demand for high-efficiency thermal energy devices. However, conventional laser-induced fluorescence (LIF) and two-color LIF method require fluorescent dyes to be dissolved in the working fluid, making the measurements susceptible to variations in the chemical properties and concentration of the fluid.To address these issues, this study develops a two-color microparticle method in which temperature sensitivity is imparted into solid microparticles, enabling simultaneous temperature and velocity measurements in unsteady thermo-fluid flows while minimizing the influence of the working fluid. Lumisis G-3300 was employed as a reference dye, while Pt (II) meso-tetra(pentafluorophenyl) porphine was used as a temperature-sensitive dye. These dyes were encapsulated within a polymer matrix to fabricate two-color microparticles. The particles were synthesized using a liquid-phase drying method and exhibited stable two-color emission characteristics with a high signal-to-noise ratio, enabling non-contact temperature measurement based on the fluorescence intensity ratio.Validation experiments in a uniform temperature field demonstrated a temperature measurement accuracy characterized by an average standard deviation in both time and space of 1.18 °C over the temperature range of 15–35 °C, confirming accuracy comparable to or higher than that of conventional thermography. The proposed method was applied to a natural convection flow in a simple water tank by combining it with particle image velocimetry (PIV). The obtained temperature distributions and flow structures agreed well with previous studies, demonstrating the validity of the proposed method.
- 6 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDevelopment of a Two-color Microparticle Method for Simultaneous Temperature and Velocity Field Measurement
In recent years, the importance of simultaneous measurement techniques for temperature and velocity fields in strongly coupled thermo-fluid flows has increased due to the demand for high-efficiency thermal energy devices. However, conventional laser-induced fluorescence (LIF) and two-color LIF method require fluorescent dyes to be dissolved in the working fluid, making the measurements susceptible to variations in the chemical properties and concentration of the fluid.To address these issues, this study develops a two-color microparticle method in which temperature sensitivity is imparted into solid microparticles, enabling simultaneous temperature and velocity measurements in unsteady thermo-fluid flows while minimizing the influence of the working fluid. Lumisis G-3300 was employed as a reference dye, while Pt (II) meso-tetra(pentafluorophenyl) porphine was used as a temperature-sensitive dye. These dyes were encapsulated within a polymer matrix to fabricate two-color microparticles. The particles were synthesized using a liquid-phase drying method and exhibited stable two-color emission characteristics with a high signal-to-noise ratio, enabling non-contact temperature measurement based on the fluorescence intensity ratio.Validation experiments in a uniform temperature field demonstrated a temperature measurement accuracy characterized by an average standard deviation in both time and space of 1.18 °C over the temperature range of 15–35 °C, confirming accuracy comparable to or higher than that of conventional thermography. The proposed method was applied to a natural convection flow in a simple water tank by combining it with particle image velocimetry (PIV). The obtained temperature distributions and flow structures agreed well with previous studies, demonstrating the validity of the proposed method.
- Open Access
- 8 July 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (2)
Enhanced thermal conductivity of fluids by percolating high-concentration few-layer graphene
High-performance and small-sized heat exchangers have been demanded due to the miniaturization and higher output of electronic devices, lasers, and energy harvesting/storage systems. Graphene nanosheet suspension has attracted attention as a next-generation nanofluid because of its high thermal conductivity and low pressure drop, while being dispersed stably without any additives. Graphene-based nanofluids have been mostly investigated using graphene oxide, and there are a few studies on pure graphene because of the limitation in mass production and stabilization at high concentrations of graphene. In this study, we prepared a 10 wt. % high-concentration few-layer graphene suspension by pulverizing graphite particles. Scanning electron microscopy, atomic force microscopy, and Raman spectra confirmed the few-layer graphene is formed in the suspension. The thermal conductivity of the suspension increased with concentration and suddenly jumped at a specific concentration. Furthermore, a significant improvement in thermal conductivity of >40% compared to base liquid was confirmed at 10 wt. % graphene content. A similar trend was observed for electrical resistance; 10 wt. % graphene suspension showed 62% lower resistance than that of 1 wt. %. These results suggest the percolation of graphene in a liquid, which has not been observed for graphene-based materials in previous research.
- 8 July 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (2)
Open AccessEnhanced thermal conductivity of fluids by percolating high-concentration few-layer graphene
High-performance and small-sized heat exchangers have been demanded due to the miniaturization and higher output of electronic devices, lasers, and energy harvesting/storage systems. Graphene nanosheet suspension has attracted attention as a next-generation nanofluid because of its high thermal conductivity and low pressure drop, while being dispersed stably without any additives. Graphene-based nanofluids have been mostly investigated using graphene oxide, and there are a few studies on pure graphene because of the limitation in mass production and stabilization at high concentrations of graphene. In this study, we prepared a 10 wt. % high-concentration few-layer graphene suspension by pulverizing graphite particles. Scanning electron microscopy, atomic force microscopy, and Raman spectra confirmed the few-layer graphene is formed in the suspension. The thermal conductivity of the suspension increased with concentration and suddenly jumped at a specific concentration. Furthermore, a significant improvement in thermal conductivity of >40% compared to base liquid was confirmed at 10 wt. % graphene content. A similar trend was observed for electrical resistance; 10 wt. % graphene suspension showed 62% lower resistance than that of 1 wt. %. These results suggest the percolation of graphene in a liquid, which has not been observed for graphene-based materials in previous research.
- 16 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 884-888
Numerical Investigation of Shape of Blood Heat Exchange Catheter
Despite the numerous advantages of blood heat exchange catheters, there is a high risk of thrombosis. It is believed that thrombus formation is accelerated by the presence of vortices and shear rate. In this study, the blood flow around a catheter in a blood vessel was analyzed using computational fluid dynamics to investigate the shape of a blood heat exchange catheter that suppresses thrombus formation and improves cooling efficiency. The flow was evaluated based on the velocity vector, vorticity, shear rate, pressure, and temperature. The results show that some convex shapes improve heat exchange performance without generating shear rates that promote thrombus formation.
- 16 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 884-888
Numerical Investigation of Shape of Blood Heat Exchange Catheter
Despite the numerous advantages of blood heat exchange catheters, there is a high risk of thrombosis. It is believed that thrombus formation is accelerated by the presence of vortices and shear rate. In this study, the blood flow around a catheter in a blood vessel was analyzed using computational fluid dynamics to investigate the shape of a blood heat exchange catheter that suppresses thrombus formation and improves cooling efficiency. The flow was evaluated based on the velocity vector, vorticity, shear rate, pressure, and temperature. The results show that some convex shapes improve heat exchange performance without generating shear rates that promote thrombus formation.
- 24 March 2023
- Published by Elsevier in Applied Thermal Engineering
- Vol. 228
Flat plate pulsating heat pipe operating at ultra-low filling ratio
- 24 March 2023
- Published by Elsevier in Applied Thermal Engineering
- Vol. 228
Flat plate pulsating heat pipe operating at ultra-low filling ratio
- Open Access
- 1 January 2022
- Published by The Visualization Society of Japan in Journal of the Visualization Society of Japan
- Vol. 42 (164) , 22-25
磁性ナノ粒子含有マイクロ粒子を用いた磁性流れ場の可視化
磁性流体は液体そのものが磁性を持ったかのようにふるまう.中でも,“感温磁性流体”は100度以下の範囲で磁化の温度依存性が大きいことから,熱輸送デバイスへの応用が期待されている.磁性流体中の強磁性粒子は鎖状クラスターを構成することが知られており,このクラスター構造が熱移動の促進を引き起こす一方で,閉塞を引き起こすトレードオフの関係にある.デバイスの実用化,高機能化に際して,このクラスターの形成特性の理解と制御が重要である.しかし,磁性流体は黒色不透明かつ,磁性粒子はナノサイズであるため,実験的な局所流れ場の取得が困難である.そこで,著者らは磁性ナノ粒子をそれよりも大粒形のポリマーマイクロ粒子に封入し,蛍光標識をすることで磁性流れ場,クラスターの挙動を可視化計測し,流動特性の把握を試みている.著者らが合成した磁性マイクロ粒子,計測した磁性クラスターや流れ場について最近の試みを紹介する.
- 1 January 2022
- Published by The Visualization Society of Japan in Journal of the Visualization Society of Japan
- Vol. 42 (164) , 22-25
Open Access磁性ナノ粒子含有マイクロ粒子を用いた磁性流れ場の可視化
磁性流体は液体そのものが磁性を持ったかのようにふるまう.中でも,“感温磁性流体”は100度以下の範囲で磁化の温度依存性が大きいことから,熱輸送デバイスへの応用が期待されている.磁性流体中の強磁性粒子は鎖状クラスターを構成することが知られており,このクラスター構造が熱移動の促進を引き起こす一方で,閉塞を引き起こすトレードオフの関係にある.デバイスの実用化,高機能化に際して,このクラスターの形成特性の理解と制御が重要である.しかし,磁性流体は黒色不透明かつ,磁性粒子はナノサイズであるため,実験的な局所流れ場の取得が困難である.そこで,著者らは磁性ナノ粒子をそれよりも大粒形のポリマーマイクロ粒子に封入し,蛍光標識をすることで磁性流れ場,クラスターの挙動を可視化計測し,流動特性の把握を試みている.著者らが合成した磁性マイクロ粒子,計測した磁性クラスターや流れ場について最近の試みを紹介する.
- Open Access
- 1 January 2022
- Published by The Visualization Society of Japan in Journal of the Visualization Society of Japan
- Vol. 42 (164) , 1
Visualization of Complex Fluid Flow
- 1 January 2022
- Published by The Visualization Society of Japan in Journal of the Visualization Society of Japan
- Vol. 42 (164) , 1
Open AccessVisualization of Complex Fluid Flow
- 1 February 2021
- Published by AIP Publishing in Physics of Fluids
- Vol. 33 (2) , 027101
Relationship between human exhalation diffusion and posture in face-to-face scenario with utterance
Because of the COVID-19, the world has been affected significantly. Not only health and medical problems but also the decline in life quality and economic activity due to the suspension of social activities cannot be disregarded. It is assumed that the virus is transmitted through coughing and sneezing; however, the possibility of airborne infection by aerosols containing viruses scattered in the air has become a popular topic recently. In airborne infections, the risk of infection increases when the mucous membrane is exposed to exhaled aerosols for a significant amount of time. Therefore, in this study, we visualize human breath using the smoke of electronic cigarettes as tracer particles. Exhalation when speaking was visualized for four human posture patterns. The result shows that the exhaled breath is affected by the body wall temperature; it rises when it remains in the boundary layer by wearing a mask. On the other hand, without a mask, it initially flows downward due to the structure of the nose and mouth, so it flows downward due to inertia and diffuses randomly. This finding is effective in reducing the risk of infection during face-to-face customer service.
- 1 February 2021
- Published by AIP Publishing in Physics of Fluids
- Vol. 33 (2) , 027101
Relationship between human exhalation diffusion and posture in face-to-face scenario with utterance
Because of the COVID-19, the world has been affected significantly. Not only health and medical problems but also the decline in life quality and economic activity due to the suspension of social activities cannot be disregarded. It is assumed that the virus is transmitted through coughing and sneezing; however, the possibility of airborne infection by aerosols containing viruses scattered in the air has become a popular topic recently. In airborne infections, the risk of infection increases when the mucous membrane is exposed to exhaled aerosols for a significant amount of time. Therefore, in this study, we visualize human breath using the smoke of electronic cigarettes as tracer particles. Exhalation when speaking was visualized for four human posture patterns. The result shows that the exhaled breath is affected by the body wall temperature; it rises when it remains in the boundary layer by wearing a mask. On the other hand, without a mask, it initially flows downward due to the structure of the nose and mouth, so it flows downward due to inertia and diffuses randomly. This finding is effective in reducing the risk of infection during face-to-face customer service.
- 15 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Magnetics Letters
- Vol. 11 (1949307X) , 1-5
Two-Dimensional Flow Field Visualization of Temperature-Sensitive Magnetic Fluids Using a Luminescent Microcapsule
There has been no study for measuring the comprehensive flow field of magnetic fluid. A pumpless transport system has been proposed based on the temperature dependence of the magnetization of magnetic fluid; however, the knowledge regarding the internal flow is still limited. It is difficult to optimize the design and realize practical use of the transport system using magnetic fluid. Therefore, in this study, for the first time, a two-dimensional flow field was visualized by encapsulating a magnetic material in a microcapsule and labeling it with fluorescence. The flow field was measured with high accuracy using the fluorescent capsule, and the effectiveness of this method was demonstrated. When a magnetic field was applied, the location of the velocity peak shifted toward the magnetic field. Chain clusters were generated and gathered on a wall. The clusters maintained their shape and slid on the wall owing to the fluid shear force. At high temperatures, the capsules did not form clusters, and there was no change in peak velocity. In a previous study, it was shown that the heat transfer efficiency of magnetic fluid increases when a magnetic field is applied. In this study, it was suggested for the first time that the clusters generated on the wall promoted heat transfer on the wall, and the wall velocity could induce a change in the temperature boundary condition. The results of this study can help elucidate the flow characteristics of magnetic fluid and optimize the device design of the transport system using magnetic fluid.
- 15 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Magnetics Letters
- Vol. 11 (1949307X) , 1-5
Two-Dimensional Flow Field Visualization of Temperature-Sensitive Magnetic Fluids Using a Luminescent Microcapsule
There has been no study for measuring the comprehensive flow field of magnetic fluid. A pumpless transport system has been proposed based on the temperature dependence of the magnetization of magnetic fluid; however, the knowledge regarding the internal flow is still limited. It is difficult to optimize the design and realize practical use of the transport system using magnetic fluid. Therefore, in this study, for the first time, a two-dimensional flow field was visualized by encapsulating a magnetic material in a microcapsule and labeling it with fluorescence. The flow field was measured with high accuracy using the fluorescent capsule, and the effectiveness of this method was demonstrated. When a magnetic field was applied, the location of the velocity peak shifted toward the magnetic field. Chain clusters were generated and gathered on a wall. The clusters maintained their shape and slid on the wall owing to the fluid shear force. At high temperatures, the capsules did not form clusters, and there was no change in peak velocity. In a previous study, it was shown that the heat transfer efficiency of magnetic fluid increases when a magnetic field is applied. In this study, it was suggested for the first time that the clusters generated on the wall promoted heat transfer on the wall, and the wall velocity could induce a change in the temperature boundary condition. The results of this study can help elucidate the flow characteristics of magnetic fluid and optimize the device design of the transport system using magnetic fluid.