LYLi Yu

Li Yu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Li Yu has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Online Assessment of Conservation Voltage Reduction Effects With Micro-perturbation

    by Jian Xu, Boyu Xie, Siyang Liao, Yuanzhang Sun, Deping Ke, Jun Yang, Peng Li, Li Yu, Quan Xu, Xiyuan Ma

    Online assessment of conservation voltage reduction (CVR) has great effects on the performance of CVR-based appli-cations, especially for real-time CVR-based controls. The chal-lenges of online CVR assessment mainly come from time-varying load composition and inevitable noise. Besides, the dynamic pro-cess resulting from motors further complicates this problem. This paper proposes a micro-perturbation based load-to-voltage (LTV) process identification method to online assess the CVR effects. In particular, we construct a well-designed pseudo-random-binary-sequence voltage perturbation to excite the CVR process continu-ally and fully. With the experimental data, the CVR factor and transfer function of LTV are estimated by the cross-correlation method, which can reflect both steady-state and dynamic CVR ef-fects without being affected by noise. The proposed method is ver-ified on a specific hardware-in-the-loop testbed under various cases. In addition, through the energy-saving and power smooth-ing applications, the impact of CVR assessment on performance of CVR-based applications is also analyzed, which further verify the validity and economic benefits of the proposed assessment method.


  • Open Access

    Traveling-Wave Based Fault Location for Phase-to-Ground Fault in Non-Effectively Earthed Distribution Networks

    by Yani Wang, Tao Zheng, Chang Yang, Li Yu

    This paper presents a multi-terminal traveling-wave-based fault location method for phase-to-ground fault in non-effectively earthed distribution systems. To improve the accuracy of fault location, a two-terminal approach is used to identify the faulty branch and a single-ended approach is followed to determine the fault distance based on the arrival time of reflected traveling waves. Wavelet decomposition is employed to extract the time-frequency component of the aerial-mode traveling waves. Magnitude and polarity of the wavelet coefficients are used to estimate the fault distance starting from the propagation fault point to the branch terminal. In addition, the network is divided into several sub-networks in order to reduce the number of measurement units. The effectiveness of this approach is demonstrated by simulations considering the phase-to-ground fault that happens at different positions in the distribution network.


  • Open Access

    Research on Optimal D-PMU Placement Technology to Improve the Observability of Smart Distribution Networks

    by Xiangyu Kong, Xiaoxiao Yuan, Yuting Wang, Yong Xu, Li Yu

    With the continuous development of smart distribution networks, their observable problems have become more serious. Research on the optimal placement of the distribution phasor measurement unit (D-PMU) is an important way to improve the measurability, observability and controllability of a smart distribution network. In this paper, the optimal D-PMU placement methods and implementation technology were studied to determine the optimal D-PMU placement scheme. Considering the bus vulnerability index and the different operating states of the system, the more practical one-time optimal placement methods to ensure complete system observability was proposed. On this basis, the system's measurement redundancy and unobservable depth were considered to realize the multistage optimal D-PMU placement. The corresponding mathematical model and solution flow were given. Then the implementation technology of the methods was studied and the optimal D-PMU placement assistant decision-making software for smart distribution network was developed. Thereby, the structure and requirements of different distribution networks can be satisfied. The application analysis, functional architecture and the overall design process were given. Finally, the methods and software were analyzed by using the IEEE 33 bus system and an actual project, the Guangzhou Nansha Yuan'an Substation. The verification results showed that the method and software mentioned in this paper can provide convenient and quick operation for optimal D-PMU placement, improve the efficiency of smart distribution network planning work, and promote the theoretical application level of smart distribution network planning results.


  • Open Access

    Multi Objective for PMU Placement in Compressed Distribution Network Considering Cost and Accuracy of State Estimation

    by Xiangyu Kong, Yuting Wang, Xiaoxiao Yuan, Li Yu

    A phasor measurement unit (PMU) can provide phasor measurements to the distribution network to improve observability. Based on pre-configuration and existing measurements, a network compression method is proposed to reduce PMU candidate locations. Taking the minimum number of PMUs and the lowest state estimation error as the objective functions and taking full observability of distribution network as the constraint, a multi objective model of optimal PMU placement (OPP) is proposed. A hybrid state estimator based on supervisory control and data acquisition (SCADA) and PMU measurements is proposed. To reduce the number of PMUs required for full observability, SCADA measurement data are also considered into the constraint by update and equivalent. In addition, a non-dominated sorting genetic algorithm-II (NSGA-II) is applied to solve the model to get the Pareto set. Finally, the optimal solution is selected from the Pareto set by the technique for order preference by similarity to ideal solution (TOPSIS). The effectiveness of the proposed method is verified by IEEE standard bus systems.


  • Open Access

    Consensus Control of Distributed Energy Resources in a Multi-Bus Microgrid for Reactive Power Sharing and Voltage Control

    by Li Yu, Di Shi, Guangyue Xu, Xiaobin Guo, Zhen Jiang, Chaoyang Jing

    The hierarchical control architecture, including layers of primary, secondary and tertiary controls, is becoming the standard operating paradigm for microgrids (MGs). Two major factors that limit the adoption of existing hierarchical control in microgrid are the low accuracy in reactive power sharing and the requirement for complex communication infrastructure. This paper addresses this problem by proposing a novel distributed primary and secondary control for distributed generators dispersed in a multi-bus microgrid. The proposed method realizes voltage control and accurate reactive power sharing in a distributed manner using minimum communication. Each distributed generator only needs its own information and minimum information from its neighboring units. Topology of the network can be flexible which supports the plug-and-play feature of microgrids. In a distribution system, high R/X ratio and system imbalance can no longer be neglected and thus the sequence component analysis and virtual impedance are implemented in the proposed control framework. The proposed framework is validated by simulation results on a MG testbed modified from the IEEE 13-bus distribution system.


  • Open Access

    A Hybrid State Estimator Based on SCADA and PMU Measurements for Medium Voltage Distribution System

    by Xiangyu Kong, Ying Chen, Tao Xu, Chengshan Wang, Chengsi Yong, Peng Li, Li Yu

    With the increasing importance of renewable energy and flexible loads, the operation of the distribution system is becoming more stochastic and complex, and it is necessary to monitor the power system in real-time. Considering the gradual applications of intelligent electronic devices in the distribution systems, a hybrid state estimator based on supervisory control and data acquisition (SCADA) and phasor measurement unit (PMU) measurements is proposed in this paper, which consists of the improved robust estimation and linear state estimation. At the time of SCADA data acquisition, the improved robust estimation combining the SCADA measurements with PMU measurements is performed. To eliminate the effect of bad data, the internal student residual method is introduced, and the robust thresholds are adjusted adaptively. Then the linear state estimation is performed at the time of PMU data acquisition based on the results of the previous estimation time and the PMU measurements, which can quickly correct the robust estimation results and track the changes of the distribution system. Finally, the effectiveness and performance of the proposed method are verified in a modified IEEE 33-bus distribution system and a real distribution system in China.


  • Open Access

    Robust Smart Meter Data Analytics Using Smoothed ALS and Dynamic Time Warping

    by Zhen Jiang, Di Shi, Xiaobin Guo, Guangyue Xu, Li Yu, Chaoyang Jing

    This paper presents a robust data-driven framework for clustering large-scale daily chronological load curves from smart meters, with a focus on the challenges encountered in practice. The first challenge is the low data quality issue due to bad and missing data, which has been a major obstacle for various in-depth analyses of smart meter data. A novel Smoothed Alternating Least Squares (SALS) approach is proposed to recover missing/bad smart meter data by taking advantage of their low-rank property. The second challenge is brought by different data reporting rates of smart meters. A Dynamic Time Warping (DTW)-based approach is proposed that is more efficient and eliminates the need for data interpolation or measurement downsampling. The proposed approach enables flexible data collection strategies and gateway locations to meet various smart grid performance requirements. The proposed framework is tested through experiments using real-world smart meter data.