Nicholas A. Thurn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nicholas A. Thurn has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Mary R. Williams
National Center for Forensic Science, University of Central Florida, P.O. Box 162367, Orlando, FL 32816-2367, USA
2 shared publications - Michael E. Sigman
Department of Chemistry, University of Central Florida, P.O. Box 162367, Orlando, FL 32816-2366, USA
2 shared publications - Alyssa Allen
Department of Chemistry, University of Central Florida, P.O. Box 162367, Orlando, FL 32816-2366, USA
1 shared publication
Latest Publications
- Open Access
- 31 October 2018
- Published by MDPI AG in Separations
- Vol. 5 (4) , 52
Application of Self-Organizing Maps to the Analysis of Ignitable Liquid and Substrate Pyrolysis Samples
Classification of un-weathered ignitable liquids is a problem that is currently addressed by visual pattern recognition under the guidelines of Standard Test Method for Ignitable Liquid Residues in Extracts from Fire Debris Samples by Gas Chromatography-Mass Spectrometry, ASTM E1618-14. This standard method does not separately address the identification of substrate pyrolysis patterns. This report details the use of a Kohonen self-organizing map coupled with extracted ion spectra to organize ignitable liquids and substrate pyrolysis samples on a two-dimensional map with groupings that correspond to the ASTM-classifications and separate the substrate pyrolysis samples from the ignitable liquids. The component planes give important information regarding the ions from the extracted ion spectra that contribute to the different classes. Some additional insight is gained into grouping of substrate pyrolysis samples based on the nature of the unburned material as a wood or non-wood material. Further subclassification was not apparent from the self-organizing maps (SOM) results.
- 31 October 2018
- Published by MDPI AG in Separations
- Vol. 5 (4) , 52
Open AccessApplication of Self-Organizing Maps to the Analysis of Ignitable Liquid and Substrate Pyrolysis Samples
Classification of un-weathered ignitable liquids is a problem that is currently addressed by visual pattern recognition under the guidelines of Standard Test Method for Ignitable Liquid Residues in Extracts from Fire Debris Samples by Gas Chromatography-Mass Spectrometry, ASTM E1618-14. This standard method does not separately address the identification of substrate pyrolysis patterns. This report details the use of a Kohonen self-organizing map coupled with extracted ion spectra to organize ignitable liquids and substrate pyrolysis samples on a two-dimensional map with groupings that correspond to the ASTM-classifications and separate the substrate pyrolysis samples from the ignitable liquids. The component planes give important information regarding the ions from the extracted ion spectra that contribute to the different classes. Some additional insight is gained into grouping of substrate pyrolysis samples based on the nature of the unburned material as a wood or non-wood material. Further subclassification was not apparent from the self-organizing maps (SOM) results.
- Open Access
- 3 September 2018
- Published by MDPI AG in Separations
- Vol. 5 (3) , 44
Model Distribution Effects on Likelihood Ratios in Fire Debris Analysis
Computational models for determining the strength of fire debris evidence based on likelihood ratios (LR) were developed and validated against data sets derived from different distributions of ASTM E1618-14 designated ignitable liquid class and substrate pyrolysis contributions using in-silico generated data. The models all perform well in cross validation against the distributions used to generate the model. However, a model generated based on data that does not contain representatives from all of the ASTM E1618-14 classes does not perform well in validation with data sets that contain representatives from the missing classes. A quadratic discriminant model based on a balanced data set (ignitable liquid versus substrate pyrolysis), with a uniform distribution of the ASTM E1618-14 classes, performed well (receiver operating characteristic area under the curve of 0.836) when tested against laboratory-developed casework-relevant samples of known ground truth.
- 3 September 2018
- Published by MDPI AG in Separations
- Vol. 5 (3) , 44
Open AccessModel Distribution Effects on Likelihood Ratios in Fire Debris Analysis
Computational models for determining the strength of fire debris evidence based on likelihood ratios (LR) were developed and validated against data sets derived from different distributions of ASTM E1618-14 designated ignitable liquid class and substrate pyrolysis contributions using in-silico generated data. The models all perform well in cross validation against the distributions used to generate the model. However, a model generated based on data that does not contain representatives from all of the ASTM E1618-14 classes does not perform well in validation with data sets that contain representatives from the missing classes. A quadratic discriminant model based on a balanced data set (ignitable liquid versus substrate pyrolysis), with a uniform distribution of the ASTM E1618-14 classes, performed well (receiver operating characteristic area under the curve of 0.836) when tested against laboratory-developed casework-relevant samples of known ground truth.