Wojciech Orzepowski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wojciech Orzepowski has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Grzegorz Pęczkowski
Department of Environmental Protection and Management, Wroclaw University of Environmental and Life Sciences, Pl. Grunwaldzki 24, 50-363 Wroclaw, Poland
4 shared publications - Ryszard Pokładek
Faculty of Environmental Engineering and Geodesy, Wrocław University of Environmental and Life Sciences, Grunwaldzka St. 55, bldg. C5, 50-357 Wrocław, Poland
3 shared publications - Tomasz Kowalczyk
Department of Environmental Protection and Development, Wroclaw University of Environmental and Life Sciences, Grunwaldzki Sq. 24, 50-363 Wrocław, Poland
3 shared publications - Katarzyna Szawernoga
Institute of Environmental Protection and Management, Wroclaw University of Environmental and Life Sciences, Pl. Grunwaldzki 24, 50-363 Wroclaw, Poland
2 shared publications - Rafal Wojcik
Department of Environmental Protection and Management, Wroclaw University of Environmental and Life Sciences, Pl. Grunwaldzki 24, 50-363 Wroclaw, Poland
2 shared publications - Adam Mariusz Paruch
Division of Environment and Natural Resources, Norwegian Institute of Bioeconomy Research-NIBIO, Oluf Thesens vei 43, 1433, Ås, Norway
1 shared publication
Latest Publications
- Open Access
- 26 December 2025
- Published by MDPI AG in Sustainability
- Vol. 18 (1) , 269
Cooling Performance of Green Walls Under Diverse Conditions in the Urban Zone of Lower Silesia
Green facades, commonly referred to as vertical plant systems, offer sustainable solutions. They improve the energy efficiency of buildings, reduce energy consumption, and positively impact the microclimate both at the microscale and at the urban level. Their ability to regulate temperature and improve thermal comfort, including mitigating the heat island effect, makes them a valuable element of sustainable architectural design. They also contribute to reduced energy consumption, reduced noise, mitigation of air pollution, and aesthetic and wind protection. The main goal of the study was to analyse the cooling effectiveness of green walls in a transitional temperate climate zone. The study was conducted on two experimental models located on the campus of the Wrocław University of Environmental and Life Sciences and at the Research and Educational Station in a suburban area. Both locations had different characteristics: the former contained urban development, while the latter contained open and sparsely developed areas. On warm and sunny days, the cooling effects of the systems were observed independently for both locations and their exposures. For data acquisition at a distance of 5 cm from the plants, a higher data concentration and a lower variability in the mean temperature drop were observed. In the same group, on sunny days, the cooling effect averaged 4–7 °C and depended on the location. On cloudy days, the mean maximum cooling in this group did not exceed 4 °C.
- 26 December 2025
- Published by MDPI AG in Sustainability
- Vol. 18 (1) , 269
Open AccessCooling Performance of Green Walls Under Diverse Conditions in the Urban Zone of Lower Silesia
Green facades, commonly referred to as vertical plant systems, offer sustainable solutions. They improve the energy efficiency of buildings, reduce energy consumption, and positively impact the microclimate both at the microscale and at the urban level. Their ability to regulate temperature and improve thermal comfort, including mitigating the heat island effect, makes them a valuable element of sustainable architectural design. They also contribute to reduced energy consumption, reduced noise, mitigation of air pollution, and aesthetic and wind protection. The main goal of the study was to analyse the cooling effectiveness of green walls in a transitional temperate climate zone. The study was conducted on two experimental models located on the campus of the Wrocław University of Environmental and Life Sciences and at the Research and Educational Station in a suburban area. Both locations had different characteristics: the former contained urban development, while the latter contained open and sparsely developed areas. On warm and sunny days, the cooling effects of the systems were observed independently for both locations and their exposures. For data acquisition at a distance of 5 cm from the plants, a higher data concentration and a lower variability in the mean temperature drop were observed. In the same group, on sunny days, the cooling effect averaged 4–7 °C and depended on the location. On cloudy days, the mean maximum cooling in this group did not exceed 4 °C.
- Open Access
- 17 November 2025
- Published by MDPI AG in Preprints.org
Cooling Performance of Green Walls Under Diverse Conditions in the Urban Zone of Lower Silesia
Environmental awareness and sustainable development in the context of energy secu-rity, including reduced energy consumption, increasingly require the introduction of innovative solutions in urban areas. These will primarily be systems based on natural architecture, particularly green facades and green roofs. In the near future, they will undoubtedly constitute an integral element of most architectural solutions and are al-ready a standard within global development strategies. Society faces the priority of achieving carbon neutrality, reducing the consumption of natural resources, and minimising the carbon footprint. This paper analyses the temperature around the canopy and the rear surfaces of two experimental models of green facades located on the campus of the University of Life Sciences in the centre of Wroclaw and at the Re-search and Educational Station of the same institution located in the suburban area of Swojec, southern Poland. In both cases, the locations can be classified within the same region, a transitional temperate climate zone. The purpose of the study was to evaluate the thermal effect of two locations with different characteristics, determined in the first case by dense urban development, and in the second by open and sparsely devel-oped areas. Analysis of average temperature reductions for warm and sunny days re-vealed a significant cooling effect. This effect was observed for green surfaces, regard-less of the location and display of the model. For the variant at a distance of 5 cm from the plants, a higher data concentration and a lower variability were recorded. In the same group, on sunny days, the cooling effect, depending on the location, was 4-7° C. On cloudy days, average maximum cooling in this group did not exceed 4° C. It should be emphasised that future research should focus on other elements of these systems, employ a multidisciplinary approach, and additionally have a significant impact on the urban microclimate and the immediate surroundings of the facades.
- 17 November 2025
- Published by MDPI AG in Preprints.org
Open AccessCooling Performance of Green Walls Under Diverse Conditions in the Urban Zone of Lower Silesia
Environmental awareness and sustainable development in the context of energy secu-rity, including reduced energy consumption, increasingly require the introduction of innovative solutions in urban areas. These will primarily be systems based on natural architecture, particularly green facades and green roofs. In the near future, they will undoubtedly constitute an integral element of most architectural solutions and are al-ready a standard within global development strategies. Society faces the priority of achieving carbon neutrality, reducing the consumption of natural resources, and minimising the carbon footprint. This paper analyses the temperature around the canopy and the rear surfaces of two experimental models of green facades located on the campus of the University of Life Sciences in the centre of Wroclaw and at the Re-search and Educational Station of the same institution located in the suburban area of Swojec, southern Poland. In both cases, the locations can be classified within the same region, a transitional temperate climate zone. The purpose of the study was to evaluate the thermal effect of two locations with different characteristics, determined in the first case by dense urban development, and in the second by open and sparsely devel-oped areas. Analysis of average temperature reductions for warm and sunny days re-vealed a significant cooling effect. This effect was observed for green surfaces, regard-less of the location and display of the model. For the variant at a distance of 5 cm from the plants, a higher data concentration and a lower variability were recorded. In the same group, on sunny days, the cooling effect, depending on the location, was 4-7° C. On cloudy days, average maximum cooling in this group did not exceed 4° C. It should be emphasised that future research should focus on other elements of these systems, employ a multidisciplinary approach, and additionally have a significant impact on the urban microclimate and the immediate surroundings of the facades.
- Open Access
Economic Analysis of the Operation of a Hydropower Plant in a Wastewater Treatment Plant: Toruń, Poland
The energy industry is constantly changing and evolving. One of the visible solutions is the pursuit of low-emission solutions. One such solution is investment in renewable energy sources (RESs), including hydropower, which in 2023 will constitute a dominant share in the production of electricity from RESs (47.02%) in the world. One of the alternative solutions is the use of hydropower in wastewater treatment plants, whose global potential is estimated at about 4350 TWh. An important issue in the operation of these facilities is their profitability. This article presents an economic analysis of a hydropower plant in the wastewater treatment plant in Toruń (northern Poland) in order to assess its profitability in the context of profits, costs, and payback period. The analyses showed the profitability of 9 out of 12 characterized variants, with the payback period estimated for real variants at 10.75–23.74 years and for theoretical variants at 5.06–5.32 years. The most significant factor in reducing the payback period was the level of electricity production between years, while different types of settlements and changes in electricity sales prices played a lesser role. Taking into account all profitable variants, after 25 years of operation, the net income will amount to PLN 1.07 million for the actual variants and PLN 3.18 million for the theoretical variants. The work can contribute to understanding the specifics of the operation of such facilities, which is consistent with, among others, the goals of sustainable development, climate and energy policies, or the circular economy.
Open AccessEconomic Analysis of the Operation of a Hydropower Plant in a Wastewater Treatment Plant: Toruń, Poland
The energy industry is constantly changing and evolving. One of the visible solutions is the pursuit of low-emission solutions. One such solution is investment in renewable energy sources (RESs), including hydropower, which in 2023 will constitute a dominant share in the production of electricity from RESs (47.02%) in the world. One of the alternative solutions is the use of hydropower in wastewater treatment plants, whose global potential is estimated at about 4350 TWh. An important issue in the operation of these facilities is their profitability. This article presents an economic analysis of a hydropower plant in the wastewater treatment plant in Toruń (northern Poland) in order to assess its profitability in the context of profits, costs, and payback period. The analyses showed the profitability of 9 out of 12 characterized variants, with the payback period estimated for real variants at 10.75–23.74 years and for theoretical variants at 5.06–5.32 years. The most significant factor in reducing the payback period was the level of electricity production between years, while different types of settlements and changes in electricity sales prices played a lesser role. Taking into account all profitable variants, after 25 years of operation, the net income will amount to PLN 1.07 million for the actual variants and PLN 3.18 million for the theoretical variants. The work can contribute to understanding the specifics of the operation of such facilities, which is consistent with, among others, the goals of sustainable development, climate and energy policies, or the circular economy.
- Open Access
- 11 June 2020
- Published by MDPI AG in Sustainability
- Vol. 12 (11) , 4793
Runoff and Water Quality in the Aspect of Environmental Impact Assessment of Experimental Area of Green Roofs in Lower Silesia
Green architecture, including green roofs, can limit the effects of urbanization. Green roofs soften the thermal effect in urban conditions, especially considering the significant increase in the European and global population and that a significant share of the age group, mainly the elderly is exposed to diseases caused by high temperatures. We studied runoff and the quality of water from green roof systems in Lower Silesia, within the area of the Agro and Hydrometeorology Station Wrocław-Swojec, in the years 2012–2016. In the study, two systems with a vegetation layer based on light expanded clay aggregate and perlite were analyzed. The studies were based on the assessment of peak flow reduction, rainwater volume preservation and peak wave reduction. The calculated maximum retention performance indicator, relative to rainfall, for perlite surfaces was up to 65%, and in relation to the control surface up to 49%. In addition, the quality of water from runoff was estimated in the conditions of annual atmospheric deposition, taking into account such indicators as electrolytic conductivity; the content of N, NO3, NO2, NH4, P, PO4; and the content of metals, Cu, Zn, Pb and Cd. The load of total nitrogen exceeded the values of concentration in rainwater and amounted to 7.17 and 13.01 mg∙L−1 for leca and perlite, respectively. In the case of the metal content, significantly higher concentrations of copper and zinc from green surfaces were observed in relation to precipitation. For surfaces with perlite, these were 320 mg∙L−1 and 241 mg∙L−1, respectively, with rainwater concentrations of 50 and 31 mg∙L−1.
- 11 June 2020
- Published by MDPI AG in Sustainability
- Vol. 12 (11) , 4793
Open AccessRunoff and Water Quality in the Aspect of Environmental Impact Assessment of Experimental Area of Green Roofs in Lower Silesia
Green architecture, including green roofs, can limit the effects of urbanization. Green roofs soften the thermal effect in urban conditions, especially considering the significant increase in the European and global population and that a significant share of the age group, mainly the elderly is exposed to diseases caused by high temperatures. We studied runoff and the quality of water from green roof systems in Lower Silesia, within the area of the Agro and Hydrometeorology Station Wrocław-Swojec, in the years 2012–2016. In the study, two systems with a vegetation layer based on light expanded clay aggregate and perlite were analyzed. The studies were based on the assessment of peak flow reduction, rainwater volume preservation and peak wave reduction. The calculated maximum retention performance indicator, relative to rainfall, for perlite surfaces was up to 65%, and in relation to the control surface up to 49%. In addition, the quality of water from runoff was estimated in the conditions of annual atmospheric deposition, taking into account such indicators as electrolytic conductivity; the content of N, NO3, NO2, NH4, P, PO4; and the content of metals, Cu, Zn, Pb and Cd. The load of total nitrogen exceeded the values of concentration in rainwater and amounted to 7.17 and 13.01 mg∙L−1 for leca and perlite, respectively. In the case of the metal content, significantly higher concentrations of copper and zinc from green surfaces were observed in relation to precipitation. For surfaces with perlite, these were 320 mg∙L−1 and 241 mg∙L−1, respectively, with rainwater concentrations of 50 and 31 mg∙L−1.
- Open Access
Hydrological Performance and Runoff Water Quality of Experimental Green Roofs
Within the scope of the conducted experiment the authors analysed the efficiency of runoff reduction by the system of extensive type green roofs. The observations were based on storm events in the area of Lower Silesia at the Agro and Hydrometeorology Station Wrocław-Swojec. The authors analysed the thickness of plant substrate, and also estimated the quality of runoff waters under the conditions of periodic atmospheric deposition. Also considered were such indicators as electrolytic conductivity, N, NO3−, NO2−, NH4+, P, PO43−. The experiment included roof substrates designed in two variants, with known hydraulic and physical properties of the soil material. The analysis was performed for models with vegetation layer based on pumice and zelolite, covered with five plant species from the sedum family. The modelling of the hydraulic properties was conducted with variably saturated medium, using the Hydrus 1D software. The performance of systems with primary layer thickness of 11 cm and 9, 8, 7, 6 and 5 cm was estimated. The designed models reduced the average peak flows to 89%, and in addition they caused a delay in the initiation of the runoff which was dependent on the intensity and distribution of rainfalls in time, and on the initial moisture of the profiles. Simulations, performed for variable substrate thickness, permit the conclusion that in the case of thin-layer profiles (5 cm), the relative retention index was decidedly lower and amounted to 35.9% for the substrate with zeolite (originally 60.6%) and 41% for the substrate with pumice (originally 65.7%). In the case of total nitrogen and phosphates, statistical analysis revealed significant differences (p < 0.05) in relation to specific concentrations in the rainwater and in the control surface. The total nitrogen in the runoff from the green roof was nearly twice as high as that in the rainwater and amounted to, on average, 8.3 mg L−1.
Open AccessHydrological Performance and Runoff Water Quality of Experimental Green Roofs
Within the scope of the conducted experiment the authors analysed the efficiency of runoff reduction by the system of extensive type green roofs. The observations were based on storm events in the area of Lower Silesia at the Agro and Hydrometeorology Station Wrocław-Swojec. The authors analysed the thickness of plant substrate, and also estimated the quality of runoff waters under the conditions of periodic atmospheric deposition. Also considered were such indicators as electrolytic conductivity, N, NO3−, NO2−, NH4+, P, PO43−. The experiment included roof substrates designed in two variants, with known hydraulic and physical properties of the soil material. The analysis was performed for models with vegetation layer based on pumice and zelolite, covered with five plant species from the sedum family. The modelling of the hydraulic properties was conducted with variably saturated medium, using the Hydrus 1D software. The performance of systems with primary layer thickness of 11 cm and 9, 8, 7, 6 and 5 cm was estimated. The designed models reduced the average peak flows to 89%, and in addition they caused a delay in the initiation of the runoff which was dependent on the intensity and distribution of rainfalls in time, and on the initial moisture of the profiles. Simulations, performed for variable substrate thickness, permit the conclusion that in the case of thin-layer profiles (5 cm), the relative retention index was decidedly lower and amounted to 35.9% for the substrate with zeolite (originally 60.6%) and 41% for the substrate with pumice (originally 65.7%). In the case of total nitrogen and phosphates, statistical analysis revealed significant differences (p < 0.05) in relation to specific concentrations in the rainwater and in the control surface. The total nitrogen in the runoff from the green roof was nearly twice as high as that in the rainwater and amounted to, on average, 8.3 mg L−1.