Erica Kholinne
Research Subjects
Erica Kholinne has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Jae-Man Kwak
Department of Orthopedic Surgery, Uijeongbu Eulji Medical Center, Eulji University College of Medicine, Uijeongbu, Korea
4 shared publications - In-Ho Jeon
Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
2 shared publications - In-Ho Jeon
Department of Orthopedic Surgery, Asan Medical Center, College of Medicine, Ulsan University, Seoul, South Korea
2 shared publications - Seung-Jun Hwang
Department of Anatomy, College of Medicine, University of Ulsan, Seoul, Korea
2 shared publications Asrafi Rizki Gatam
Department of Orthopedics, Gatam Institute, Tangerang, Indonesia
1 shared publication- Gu-Hee Jung
Department of Orthopedic Surgery, Gyeongsang National University Changwon Hospital, Gyeongsang National University College of Medicine, Changwon, Korea
1 shared publication
Latest Publications
- Open Access
- 20 January 2025
- Published by Frontiers Media SA in Frontiers in Surgery
- Vol. 11, 1495251
Robotic pedicle screw placement for minimal invasive thoracolumbar spine surgery: a technical note
Background: Pedicle screw placement in spine surgery is a complex and delicate procedure that requires precise and accurate placement of pedicle screws. This technical note describes the steps involved in performing robotic assistance pedicle screw insertion in thoracolumbar spine surgery using the ExcelsiusGPS platform.Methods: This paper outlines the surgical techniques and intraoperative workflow for pedicle screw placement using the ExcelsiusGPS system. It also covers the surgical process, including patient positioning, dynamic reference placement, intraoperative cone-beam tomography, screw planning, exposure, and insertion techniques for spinal stabilization.Discussion: A meta-analysis highlighted the significant advantages of robotic spine surgery over traditional freehand techniques, including a notably lower complication rate (4.83% vs. 14.97%) and up to a tenfold reduction in surgeon radiation exposure compared to fluoroscopy. Additionally, robotic systems enhance pedicle screw placement accuracy, achieving a 91.7% success rate. This higher accuracy is attributed to real-time screw planning, trajectory guidance, and precise adjustments in robotic-assisted surgery. These advantages establish robotic assistance as a crucial innovation for enhancing surgical precision and patient safety, although it requires careful handling of technical challenges like alignment changes in highly flexible bones and ensuring accurate instrument trajectory during screw placement.Conclusion: Robotic-assisted spine surgery improves pedicle screw accuracy with real-time planning and trajectory adjustments, reducing complications and radiation exposure. However, higher costs and increased screw use warrant careful evaluation of its cost-effectiveness and impact on healthcare resources.
- 20 January 2025
- Published by Frontiers Media SA in Frontiers in Surgery
- Vol. 11, 1495251
Open AccessRobotic pedicle screw placement for minimal invasive thoracolumbar spine surgery: a technical note
Background: Pedicle screw placement in spine surgery is a complex and delicate procedure that requires precise and accurate placement of pedicle screws. This technical note describes the steps involved in performing robotic assistance pedicle screw insertion in thoracolumbar spine surgery using the ExcelsiusGPS platform.Methods: This paper outlines the surgical techniques and intraoperative workflow for pedicle screw placement using the ExcelsiusGPS system. It also covers the surgical process, including patient positioning, dynamic reference placement, intraoperative cone-beam tomography, screw planning, exposure, and insertion techniques for spinal stabilization.Discussion: A meta-analysis highlighted the significant advantages of robotic spine surgery over traditional freehand techniques, including a notably lower complication rate (4.83% vs. 14.97%) and up to a tenfold reduction in surgeon radiation exposure compared to fluoroscopy. Additionally, robotic systems enhance pedicle screw placement accuracy, achieving a 91.7% success rate. This higher accuracy is attributed to real-time screw planning, trajectory guidance, and precise adjustments in robotic-assisted surgery. These advantages establish robotic assistance as a crucial innovation for enhancing surgical precision and patient safety, although it requires careful handling of technical challenges like alignment changes in highly flexible bones and ensuring accurate instrument trajectory during screw placement.Conclusion: Robotic-assisted spine surgery improves pedicle screw accuracy with real-time planning and trajectory adjustments, reducing complications and radiation exposure. However, higher costs and increased screw use warrant careful evaluation of its cost-effectiveness and impact on healthcare resources.
- 9 September 2024
- Published by Springer Nature in International Orthopaedics
- Vol. 48 (11) , 2903-2909
Lateral collateral ligament complex insufficiency in recalcitrant lateral epicondylitis: MRI evaluation with arthroscopic findings
Purpose To evaluate the concomitant pathology in recalcitrant LE using MRI with arthroscopic finding correlation. Methods A total of 49 patients were diagnosed with chronic recalcitrant LE and divided into two: LCL complex-intact and LCL complex-involved groups by evaluating MRI as confirmed by a radiologist. Patient information for the history of steroid injection and symptom duration was extracted from the medical records. Arthroscopic images taken during arthroscopic extensor carpi radialis brevis release were evaluated to assess the quality of lateral capsule and concomitant plica. Results A total of 24 and 25 patients were included in the LCL-intact and LCL-involved groups, respectively. Among them, seven had complete RCL tears recorded in the LCL-involved group. Symptom duration (15 ± 9 vs. 22 ± 13, p = 0.029) and the number of steroid injections (3 ± 2 vs. 5 ± 3, p = 0.040) were significantly higher in the LCL-involved group than that in the LCL-intact group. A capsular tear was detected for 5 (20%) patients in the LCL-intact and 14 (56%) in the LCL-involved group (p = 0.027). Concomitant plica was observed in 15 (62%) patients in LCL-intact and seven (28%) in the LCL-involved group (p = 0.015). RC joint widening was observed in four patients in the LCL-involved group. Conclusion The recalcitrant LE is highly a concomitant pathology including LCL complex insufficiency and pathologic elbow plica lesion. The risk factors of LCL insufficiency associated with refractory LE may include multiple steroid injections. Arthroscopic finding such as capsular tears and elbow drive-through signs can be suspected signs for LCL complex insufficiency.
- 9 September 2024
- Published by Springer Nature in International Orthopaedics
- Vol. 48 (11) , 2903-2909
Lateral collateral ligament complex insufficiency in recalcitrant lateral epicondylitis: MRI evaluation with arthroscopic findings
Purpose To evaluate the concomitant pathology in recalcitrant LE using MRI with arthroscopic finding correlation. Methods A total of 49 patients were diagnosed with chronic recalcitrant LE and divided into two: LCL complex-intact and LCL complex-involved groups by evaluating MRI as confirmed by a radiologist. Patient information for the history of steroid injection and symptom duration was extracted from the medical records. Arthroscopic images taken during arthroscopic extensor carpi radialis brevis release were evaluated to assess the quality of lateral capsule and concomitant plica. Results A total of 24 and 25 patients were included in the LCL-intact and LCL-involved groups, respectively. Among them, seven had complete RCL tears recorded in the LCL-involved group. Symptom duration (15 ± 9 vs. 22 ± 13, p = 0.029) and the number of steroid injections (3 ± 2 vs. 5 ± 3, p = 0.040) were significantly higher in the LCL-involved group than that in the LCL-intact group. A capsular tear was detected for 5 (20%) patients in the LCL-intact and 14 (56%) in the LCL-involved group (p = 0.027). Concomitant plica was observed in 15 (62%) patients in LCL-intact and seven (28%) in the LCL-involved group (p = 0.015). RC joint widening was observed in four patients in the LCL-involved group. Conclusion The recalcitrant LE is highly a concomitant pathology including LCL complex insufficiency and pathologic elbow plica lesion. The risk factors of LCL insufficiency associated with refractory LE may include multiple steroid injections. Arthroscopic finding such as capsular tears and elbow drive-through signs can be suspected signs for LCL complex insufficiency.
- 13 December 2023
- Published by Springer Nature in International Orthopaedics
- Vol. 48 (1) , 143-150
Arthroscopic assessment for lateral collateral ligament complex deficiency of the elbow: a cadaveric study
Purpose To evaluate whether elbow instability due to lateral collateral ligament complex injury can be assessed reliably through arthroscopy. Methods Eight fresh human cadaveric elbows were placed in a simulated lateral decubitus position. The radiocapitellar joint (RCJ) gap and ulnohumeral joint (UHJ) gap (mm) were measured with different sizes of probes from the posterolateral viewing portal. The elbow was 90 degrees flexed with neutral forearm rotation for RCJ gap measurement and 30 degrees flexed with full supination for UHJ gap measurement. Sequential testing was performed from Stage 0 to Stage 3 (Stage 0: intact; Stage 1: the release of the anterior 1/3 LCL complex; Stage 2: the release of the anterior two thirds of the LCL complex; and Stage 3: the release of the entire LCL complex) on each specimen. The mean gap of RCJ and lateral UHJ was used for the comparison between stages with the intact elbow. Results The mean RCJ gap distance in Stage 2 and Stage 3 was significantly increased compared to that in Stage 0 (Stage 0 vs. Stage 2: P = .008; Stage 0 vs. Stage 3: P = .010). The mean UHJ gap distance of Stage 1, Stage 2, and Stage 3 was significantly increased compared to that in Stage 0 (Stage 0 vs. Stage 1: P = 0.025; Stage 0 vs. Stage 2: P = .010; Stage 0 vs. Stage 3: P = .011). In contrast, the release of the anterior 1/3 of the LCL complex (Stage 1) was not significantly increased compared to the mean joint gap distance of RCJ (P = .157). Conclusion Arthroscopic measurement of joint gap widening in RCJ and UHJ is a reliable assessment method to detect LCL complex deficiency that involves the anterior two thirds or more.
- 13 December 2023
- Published by Springer Nature in International Orthopaedics
- Vol. 48 (1) , 143-150
Arthroscopic assessment for lateral collateral ligament complex deficiency of the elbow: a cadaveric study
Purpose To evaluate whether elbow instability due to lateral collateral ligament complex injury can be assessed reliably through arthroscopy. Methods Eight fresh human cadaveric elbows were placed in a simulated lateral decubitus position. The radiocapitellar joint (RCJ) gap and ulnohumeral joint (UHJ) gap (mm) were measured with different sizes of probes from the posterolateral viewing portal. The elbow was 90 degrees flexed with neutral forearm rotation for RCJ gap measurement and 30 degrees flexed with full supination for UHJ gap measurement. Sequential testing was performed from Stage 0 to Stage 3 (Stage 0: intact; Stage 1: the release of the anterior 1/3 LCL complex; Stage 2: the release of the anterior two thirds of the LCL complex; and Stage 3: the release of the entire LCL complex) on each specimen. The mean gap of RCJ and lateral UHJ was used for the comparison between stages with the intact elbow. Results The mean RCJ gap distance in Stage 2 and Stage 3 was significantly increased compared to that in Stage 0 (Stage 0 vs. Stage 2: P = .008; Stage 0 vs. Stage 3: P = .010). The mean UHJ gap distance of Stage 1, Stage 2, and Stage 3 was significantly increased compared to that in Stage 0 (Stage 0 vs. Stage 1: P = 0.025; Stage 0 vs. Stage 2: P = .010; Stage 0 vs. Stage 3: P = .011). In contrast, the release of the anterior 1/3 of the LCL complex (Stage 1) was not significantly increased compared to the mean joint gap distance of RCJ (P = .157). Conclusion Arthroscopic measurement of joint gap widening in RCJ and UHJ is a reliable assessment method to detect LCL complex deficiency that involves the anterior two thirds or more.
- 3 April 2023
- Published by Springer Nature in International Orthopaedics
- Vol. 47 (7) , 1779-1786
Biomechanical impact of elbow motion in elbow stiffness
Background A mechanical block in the elbow due to osteophytes in the olecranon fossa is a common clinical symptom for elbow stiffness. Purpose/hypothesis This study aims to understand the biomechanical characteristics or changes in the stiff elbow in the resting (or neutral) and swing position of the arm using a cadaveric model. The hypotheses included the following: (1) a difference exists in the articular contact pressure of the elbow by comparing the non-stiff and stiff models in in vivo studies; (2) the degree of stiffness would affect the increase of the joint loading of the elbow. Study design Controlled laboratory study, cadaveric study. Methods Eight fresh-frozen specimens from individuals of both sexes were included in the biomechanical study. The specimen was mounted on a custom-designed jig system with gravity-assisted muscle contracture to mimic the elbow in a standing position. The elbow was tested in two conditions (the resting and passive swing). Contact pressure was recorded for three seconds in the resting position, which was the neutral position of the humerus. By dropping the forearm from 90° of the elbow flexion, the passive swing was performed. The specimens were tested sequentially in three stages of stiffness (stage 0, no stiffness; stage 1, 30° of extension limitation; and stage 2, 60° of extension limitation). After data collection was completed in stage 0, a stiff model was sequentially created for each stage. The stiff model of the elbow was created by blocking the olecranon by inserting a 2.0 K-wire into the olecranon fossa horizontally with the intercondylar axis. Results The mean contact pressures were 279 ± 23, 302 ± 6, and 349 ± 23 kPa in stages 0, 1, and 2, respectively. The increases in the mean contact pressure in stages 2 versus 0 were significant (P < 0.0001). The mean contact pressures were 297 ± 19, 310 ± 14, and 326 ± 13 kPa in stages 0, 1, and 2, respectively. The peak contact pressures were 420 ± 54, 448 ± 84, and 500 ± 67 kPa in stages 0, 1, and 2, respectively. The increases in mean contact pressure in stage 2 versus 0 were significant (P = 0.039). The increases in peak contact pressure in stages 0 versus 2 were significant (P = 0.007). Conclusions The elbow bears the load created by gravity and muscle contracture in the resting and swing motion. Moreover, extension limitation of stiff elbow increases the load bearing in the resting position and swing motion. Careful surgical management should be considered for meticulous clearance of bony spur around olecranon fossa to resolve the extension limitation of the elbow.
- 3 April 2023
- Published by Springer Nature in International Orthopaedics
- Vol. 47 (7) , 1779-1786
Biomechanical impact of elbow motion in elbow stiffness
Background A mechanical block in the elbow due to osteophytes in the olecranon fossa is a common clinical symptom for elbow stiffness. Purpose/hypothesis This study aims to understand the biomechanical characteristics or changes in the stiff elbow in the resting (or neutral) and swing position of the arm using a cadaveric model. The hypotheses included the following: (1) a difference exists in the articular contact pressure of the elbow by comparing the non-stiff and stiff models in in vivo studies; (2) the degree of stiffness would affect the increase of the joint loading of the elbow. Study design Controlled laboratory study, cadaveric study. Methods Eight fresh-frozen specimens from individuals of both sexes were included in the biomechanical study. The specimen was mounted on a custom-designed jig system with gravity-assisted muscle contracture to mimic the elbow in a standing position. The elbow was tested in two conditions (the resting and passive swing). Contact pressure was recorded for three seconds in the resting position, which was the neutral position of the humerus. By dropping the forearm from 90° of the elbow flexion, the passive swing was performed. The specimens were tested sequentially in three stages of stiffness (stage 0, no stiffness; stage 1, 30° of extension limitation; and stage 2, 60° of extension limitation). After data collection was completed in stage 0, a stiff model was sequentially created for each stage. The stiff model of the elbow was created by blocking the olecranon by inserting a 2.0 K-wire into the olecranon fossa horizontally with the intercondylar axis. Results The mean contact pressures were 279 ± 23, 302 ± 6, and 349 ± 23 kPa in stages 0, 1, and 2, respectively. The increases in the mean contact pressure in stages 2 versus 0 were significant (P < 0.0001). The mean contact pressures were 297 ± 19, 310 ± 14, and 326 ± 13 kPa in stages 0, 1, and 2, respectively. The peak contact pressures were 420 ± 54, 448 ± 84, and 500 ± 67 kPa in stages 0, 1, and 2, respectively. The increases in mean contact pressure in stage 2 versus 0 were significant (P = 0.039). The increases in peak contact pressure in stages 0 versus 2 were significant (P = 0.007). Conclusions The elbow bears the load created by gravity and muscle contracture in the resting and swing motion. Moreover, extension limitation of stiff elbow increases the load bearing in the resting position and swing motion. Careful surgical management should be considered for meticulous clearance of bony spur around olecranon fossa to resolve the extension limitation of the elbow.
- Open Access
Improvement of arthroscopic surgical performance using a new wide-angle arthroscope
Background: We have developed a new arthroscope with a field of view of 150°. This requires less motion to maneuver, and the optical error is decreased. It also improves how novices learn arthroscopy. We hypothesized that surgical performance using this arthroscope is superior to a conventional arthroscope. This study tested the hypothesis using motion analysis and a new validated parameter, “dimensionless squared jolt” (DSJ). Methods: We compared the surgical performance using between the wide-angle and the conventional arthroscope among 14 novice orthopedic residents who performed three standardized tasks three times with each arthroscope. The tasks simulated arthroscopic rotator cuff repair surgical skills. Their motion was analyzed using an optical tracking system. The differences in performance parameters, such as time taken, average acceleration of the hands (m/s 2 ), the number of movements, and the total path length (m) including DSJ between the two arthroscopes, were investigated using paired t-tests. Results: All the estimated values for the tasks using the 150° arthroscope were lower than those for the 105° arthroscope. There were statistically significant differences in performance between the two arthroscopes only for DSJ (p = 0.014) and average acceleration (p = 0.039). Conclusions: DSJ and average acceleration are reliable parameters for representing hand-eye coordination. The surgical performance of novice arthroscopists was better with the new wide-angle arthroscope than with the conventional arthroscope.
Open AccessImprovement of arthroscopic surgical performance using a new wide-angle arthroscope
Background: We have developed a new arthroscope with a field of view of 150°. This requires less motion to maneuver, and the optical error is decreased. It also improves how novices learn arthroscopy. We hypothesized that surgical performance using this arthroscope is superior to a conventional arthroscope. This study tested the hypothesis using motion analysis and a new validated parameter, “dimensionless squared jolt” (DSJ). Methods: We compared the surgical performance using between the wide-angle and the conventional arthroscope among 14 novice orthopedic residents who performed three standardized tasks three times with each arthroscope. The tasks simulated arthroscopic rotator cuff repair surgical skills. Their motion was analyzed using an optical tracking system. The differences in performance parameters, such as time taken, average acceleration of the hands (m/s 2 ), the number of movements, and the total path length (m) including DSJ between the two arthroscopes, were investigated using paired t-tests. Results: All the estimated values for the tasks using the 150° arthroscope were lower than those for the 105° arthroscope. There were statistically significant differences in performance between the two arthroscopes only for DSJ (p = 0.014) and average acceleration (p = 0.039). Conclusions: DSJ and average acceleration are reliable parameters for representing hand-eye coordination. The surgical performance of novice arthroscopists was better with the new wide-angle arthroscope than with the conventional arthroscope.