Mohammad A. Alhassan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mohammad A. Alhassan has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Athanasios Stamos
National Technical University of Athens
1 shared publication - Emmanouil Vougioukas
Assistant Professor, Department of Civil Engineering, National Technical University of Athens, Athens, Greece
1 shared publication - Khairedin Abdalla
Department of Civil Engineering, Jordan University of Science and Technology, Irbid 22110, Jordan
1 shared publication Khairedin M. Abdalla
Civil Engineering Program, Al Ain University, Al Ain, United Arab Emirates
1 shared publicationMohammad E. Al-Shatnawi
Civil Engineering Program, Al Ain University, Al Ain, United Arab Emirates
1 shared publication- Nikos D. Lagaros
National Technical University of Athens (NTUA)
1 shared publication
Latest Publications
- Open Access
- 28 January 2023
- Published by MDPI AG in Construction Materials
- Vol. 3 (1) , 38-61
Cyclic Behavior of FRP Strengthened Beam-Column Joints under Various Concrete Damage Levels
This paper is intended to examine the efficiency of utilizing the FRP composite material with an externally bonded technique in enhancing the behavior of the damaged B-C joints and controlling their failure mode using the NLFEA approach. At first, the modeled Beam-Column joint was validated as per the previously-attained experimentally-attained results. Later, the model was widened to experiment with the impact of axial-column load and the concrete compressive strength on the reinforced and un-reinforced models with FRP. To run the experiment, there were three cases of applying the axial column load: no load applied (0%), applying 25%, applying 50%, and applying 75%, while the concrete compressive strength degradation level was (0% damage), (25% damage), and (50% damage). All models were evaluated for structural performance, considering: the failure mode, stresses distribution, and the ultimate capacities in pulling and pushing with its corresponding displacements. However, the horizontal load-displacement hysteretic loops and envelopes, stiffness degradation, displacement ductility, and energy dissipation were reported. The experimental results revealed that using FRP to externally-reinforce B-C joints improved overall cyclic performance, as the FRP caused a rise in the ultimate load capacity, horizontal displacement, ductility of displacement, and displacement energy dissipation, while it slowed down the stiffness degradation. In addition, the FRP material converted the failure mode of the region between the joint and column from brittle to ductile due to the formation of a plastic hinge only on the side of the beam when the axial column load exceeded 25%. It must be noticed that when the column’s axial load is less than 25%, the ultimate capacity of axial load and resultant deflection is solely improved. However, it has been stated that increasing the column’s axial loading by 25% increases the resulting stiffness degradation by 3% for undamaged joints, which further increases by 16% for each increased damage level. In contrast, the absorbed energy is increased by 170% under axial loading, increasing by 25%, which is reduced to only one-fourth under the various damage levels. Generally, the resulting observations help specialized engineers retrofit appropriate B-C joints in already-standing buildings due to their accuracy.
- 28 January 2023
- Published by MDPI AG in Construction Materials
- Vol. 3 (1) , 38-61
Open AccessCyclic Behavior of FRP Strengthened Beam-Column Joints under Various Concrete Damage Levels
This paper is intended to examine the efficiency of utilizing the FRP composite material with an externally bonded technique in enhancing the behavior of the damaged B-C joints and controlling their failure mode using the NLFEA approach. At first, the modeled Beam-Column joint was validated as per the previously-attained experimentally-attained results. Later, the model was widened to experiment with the impact of axial-column load and the concrete compressive strength on the reinforced and un-reinforced models with FRP. To run the experiment, there were three cases of applying the axial column load: no load applied (0%), applying 25%, applying 50%, and applying 75%, while the concrete compressive strength degradation level was (0% damage), (25% damage), and (50% damage). All models were evaluated for structural performance, considering: the failure mode, stresses distribution, and the ultimate capacities in pulling and pushing with its corresponding displacements. However, the horizontal load-displacement hysteretic loops and envelopes, stiffness degradation, displacement ductility, and energy dissipation were reported. The experimental results revealed that using FRP to externally-reinforce B-C joints improved overall cyclic performance, as the FRP caused a rise in the ultimate load capacity, horizontal displacement, ductility of displacement, and displacement energy dissipation, while it slowed down the stiffness degradation. In addition, the FRP material converted the failure mode of the region between the joint and column from brittle to ductile due to the formation of a plastic hinge only on the side of the beam when the axial column load exceeded 25%. It must be noticed that when the column’s axial load is less than 25%, the ultimate capacity of axial load and resultant deflection is solely improved. However, it has been stated that increasing the column’s axial loading by 25% increases the resulting stiffness degradation by 3% for undamaged joints, which further increases by 16% for each increased damage level. In contrast, the absorbed energy is increased by 170% under axial loading, increasing by 25%, which is reduced to only one-fourth under the various damage levels. Generally, the resulting observations help specialized engineers retrofit appropriate B-C joints in already-standing buildings due to their accuracy.
- Open Access
- 30 September 2020
- Published by Frontiers Media SA in Frontiers in Built Environment
- Vol. 6
Critical Evaluation of the Shear Lag Factor Provisions for W-Sections
Shear lagging, resulting from non-uniformity of stress distribution around the connection, is one of the most important design considerations in steel construction since it reduces the load capacity of tension members. In this paper, the rationality of the AISC provisions for calculating the shear lag factor (U) for W and WT-sections was assessed. In the current AISC provisions, there is an enormous difference in the calculated value of U using two allowed for W and WT sections; yet the AISC allows using the largest value for U. Accordingly, this study was conducted to investigate the reasonable value of U in W and WT-sections based on finite element analysis (FEA). Two criteria were used to calculate this lagging for 50 sizes of W sections and 50 sizes of WT sections. For each section size, three models with different connection lengths were created, which results in 150 models for W sections and 150 models for WT-sections. For each section type, the influence of the bolt diameter, the connection eccentricity, flange width, depth, flange area, and gross-sectional area were evaluated individually through a parametric study. It was shown that the calculated values for U based on the two cases allowed by the AISC provisions were comparable for shallow W and WT sections, but differ enormously for larger sections. Accordingly, a new equation was developed for a more reasonable calculation of U for any W and WT standard size.
- 30 September 2020
- Published by Frontiers Media SA in Frontiers in Built Environment
- Vol. 6
Open AccessCritical Evaluation of the Shear Lag Factor Provisions for W-Sections
Shear lagging, resulting from non-uniformity of stress distribution around the connection, is one of the most important design considerations in steel construction since it reduces the load capacity of tension members. In this paper, the rationality of the AISC provisions for calculating the shear lag factor (U) for W and WT-sections was assessed. In the current AISC provisions, there is an enormous difference in the calculated value of U using two allowed for W and WT sections; yet the AISC allows using the largest value for U. Accordingly, this study was conducted to investigate the reasonable value of U in W and WT-sections based on finite element analysis (FEA). Two criteria were used to calculate this lagging for 50 sizes of W sections and 50 sizes of WT sections. For each section size, three models with different connection lengths were created, which results in 150 models for W sections and 150 models for WT-sections. For each section type, the influence of the bolt diameter, the connection eccentricity, flange width, depth, flange area, and gross-sectional area were evaluated individually through a parametric study. It was shown that the calculated values for U based on the two cases allowed by the AISC provisions were comparable for shallow W and WT sections, but differ enormously for larger sections. Accordingly, a new equation was developed for a more reasonable calculation of U for any W and WT standard size.