Jakub Kolarik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jakub Kolarik has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Jan Nedoma
Department of Telecommunications, Faculty of Electrical Engineering and Computer Science, VSB—Technical University of Ostrava, 17. Listopadu 2172/15, 708 00 Ostrava, Czech Republic
8 shared publications - Radek Martinek
Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB–Technical University of Ostrava, Ostrava, Czechia
8 shared publications - Radana Kahankova
Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB–Technical University of Ostrava
6 shared publications Radek Martinek
VŠB–Technical University of Ostrava
4 shared publications- Jindrich Brablik
Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB–Technical University of Ostrava, Ostrava, Czechia
3 shared publications Lukas Soustek
VŠB–Technical University of Ostrava
3 shared publications
Latest Publications
- Open Access
- 22 July 2023
- Published by Springer Nature in Archives of Computational Methods in Engineering
- Vol. 31 (1) , 221-242
Tool Condition Monitoring Methods Applicable in the Metalworking Process
This article reviews and analyzes the approaches utilized for monitoring cutting tool conditions. The Research focuses on publications from 2012 to 2022 (10 years), in which Machine Learning and other statistical processes are used to determine the quality, condition, wear, and remaining useful life (RUL) of shearing tools. The paper quantifies the typical signals utilized by researchers and scientists (vibration of the cutting tool and workpiece, the tool cutting force, and the tool’s temperature, for example). These signals are sensitive to changes in the workpiece quality condition; therefore, they are used as a proxy of the tool degradation and the quality of the product. The selection of signals to analyze the workpiece quality and the tool wear level is still in development; however, the article shows the main signals used over the years and their correlation with the cutting tool condition. These signals can be taken directly from the cutting tool or the workpiece, the choice varies, and both have shown promising results. In parallel, the Research presents, analyzes, and quantifies some of the most utilized statistical techniques that serve as filters to cleanse the collected data before the prediction and classification phase. These methods and techniques also extract relevant and wear-sensitive information from the collected signals, easing the classifiers’ work by numerically changing alongside the tool wear and the product quality.
- 22 July 2023
- Published by Springer Nature in Archives of Computational Methods in Engineering
- Vol. 31 (1) , 221-242
Open AccessTool Condition Monitoring Methods Applicable in the Metalworking Process
This article reviews and analyzes the approaches utilized for monitoring cutting tool conditions. The Research focuses on publications from 2012 to 2022 (10 years), in which Machine Learning and other statistical processes are used to determine the quality, condition, wear, and remaining useful life (RUL) of shearing tools. The paper quantifies the typical signals utilized by researchers and scientists (vibration of the cutting tool and workpiece, the tool cutting force, and the tool’s temperature, for example). These signals are sensitive to changes in the workpiece quality condition; therefore, they are used as a proxy of the tool degradation and the quality of the product. The selection of signals to analyze the workpiece quality and the tool wear level is still in development; however, the article shows the main signals used over the years and their correlation with the cutting tool condition. These signals can be taken directly from the cutting tool or the workpiece, the choice varies, and both have shown promising results. In parallel, the Research presents, analyzes, and quantifies some of the most utilized statistical techniques that serve as filters to cleanse the collected data before the prediction and classification phase. These methods and techniques also extract relevant and wear-sensitive information from the collected signals, easing the classifiers’ work by numerically changing alongside the tool wear and the product quality.
- Open Access
- 27 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 26 (6) , 2594-2605
A Comparison of Alternative Approaches to MR Cardiac Triggering: A Pilot Study at 3 Tesla
This pilot comparative study evaluates the usability of the alternative approaches to magnetic resonance (MR) cardiac triggering based on ballistocardiography (BCG): fiber-optic sensor (O-BCG) and pneumatic sensor (P-BCG). The comparison includes both the objective and subjective assessment of the proposed sensors in comparison with a gold standard of ECG-based triggering. The objective evaluation included several image quality assessment (IQA) parameters, whereas the subjective analysis was performed by 10 experts rating the diagnostic quality (scale 1 - 3, 1 corresponding to the best image quality and 3 the worst one). Moreover, for each examination, we provided the examination time and comfort rating (scale 1 - 3). The study was performed on 10 healthy subjects. All data were acquired on a 3 T SIEMENS MAGNETOM Prisma. In image quality analysis, all approaches reached comparable results, with ECG slightly outperforming the BCG-based methods, especially according to the objective metrics. The subjective evaluation proved the best quality of ECG (average score of 1.68) and higher performance of P-BCG (1.97) than O-BCG (2.03). In terms of the comfort rating and total examination time, the ECG method achieved the worst results, i.e. the highest score and the longest examination time: 2.6 and 10:49 s, respectively. The BCG-based alternatives achieved comparable results (P-BCG 1.5 and 8:06 s; OBCG 1.9, 9:08 s). This study confirmed that the proposed BCG-based alternative approaches to MR cardiac triggering offer comparable quality of resulting images with the benefits of reduced examination time and increased patient comfort.
- 27 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 26 (6) , 2594-2605
Open AccessA Comparison of Alternative Approaches to MR Cardiac Triggering: A Pilot Study at 3 Tesla
This pilot comparative study evaluates the usability of the alternative approaches to magnetic resonance (MR) cardiac triggering based on ballistocardiography (BCG): fiber-optic sensor (O-BCG) and pneumatic sensor (P-BCG). The comparison includes both the objective and subjective assessment of the proposed sensors in comparison with a gold standard of ECG-based triggering. The objective evaluation included several image quality assessment (IQA) parameters, whereas the subjective analysis was performed by 10 experts rating the diagnostic quality (scale 1 - 3, 1 corresponding to the best image quality and 3 the worst one). Moreover, for each examination, we provided the examination time and comfort rating (scale 1 - 3). The study was performed on 10 healthy subjects. All data were acquired on a 3 T SIEMENS MAGNETOM Prisma. In image quality analysis, all approaches reached comparable results, with ECG slightly outperforming the BCG-based methods, especially according to the objective metrics. The subjective evaluation proved the best quality of ECG (average score of 1.68) and higher performance of P-BCG (1.97) than O-BCG (2.03). In terms of the comfort rating and total examination time, the ECG method achieved the worst results, i.e. the highest score and the longest examination time: 2.6 and 10:49 s, respectively. The BCG-based alternatives achieved comparable results (P-BCG 1.5 and 8:06 s; OBCG 1.9, 9:08 s). This study confirmed that the proposed BCG-based alternative approaches to MR cardiac triggering offer comparable quality of resulting images with the benefits of reduced examination time and increased patient comfort.
- Open Access
New Methods to Seismic Monitoring: Laboratory Comparative Study of Michelson Fiber-Optic Interferometer and Pneumatic Measurement Systems
New possibilities of vibration monitoring can be found in completely different physical approaches, where all measuring technology is currently based on sensors in the electrical domain. This paper presents two different promising alternative approaches to vibration measurement, specifically in the field of fiber-optics and pneumatic sensors. The proposed solution uses a Michelson fiber-optic interferometer designed without polarization fading and with operationally passive demodulation technique using three mutually phase-shifted optical outputs. Experimentally developed sensor systems for the registration of anthropogenic seismic phenomena were complemented by standard instrumentation for measuring seismicity used as a standard. The measurement was performed under simplified conditions using a calibrated stroke as a source of dynamic loading. In addition to alternative systems, the paper also presents the results of recalculation of the measured values in a time domain and basic relationships for the conversion to basic units derived from the SI (International System of Units) system and used internationally in the field of seismic engineering. The results presented demonstrate that even systems operating on a different physical principle have great potential to replace the existing seismic devices. The correlation coefficients for both sensory devices were high (above 0.9) and the average deviations from the measured values of the amplitude of the oscillation velocity did not exceed the value of 0.02, neither with the fiber-optic or pneumatic sensor.
Open AccessNew Methods to Seismic Monitoring: Laboratory Comparative Study of Michelson Fiber-Optic Interferometer and Pneumatic Measurement Systems
New possibilities of vibration monitoring can be found in completely different physical approaches, where all measuring technology is currently based on sensors in the electrical domain. This paper presents two different promising alternative approaches to vibration measurement, specifically in the field of fiber-optics and pneumatic sensors. The proposed solution uses a Michelson fiber-optic interferometer designed without polarization fading and with operationally passive demodulation technique using three mutually phase-shifted optical outputs. Experimentally developed sensor systems for the registration of anthropogenic seismic phenomena were complemented by standard instrumentation for measuring seismicity used as a standard. The measurement was performed under simplified conditions using a calibrated stroke as a source of dynamic loading. In addition to alternative systems, the paper also presents the results of recalculation of the measured values in a time domain and basic relationships for the conversion to basic units derived from the SI (International System of Units) system and used internationally in the field of seismic engineering. The results presented demonstrate that even systems operating on a different physical principle have great potential to replace the existing seismic devices. The correlation coefficients for both sensory devices were high (above 0.9) and the average deviations from the measured values of the amplitude of the oscillation velocity did not exceed the value of 0.02, neither with the fiber-optic or pneumatic sensor.
- Open Access
- 29 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Reviews in Biomedical Engineering
- Vol. 15 (19373333) , 200-221
Monitoring and Synchronization of Cardiac and Respiratory Traces in Magnetic Resonance Imaging: A Review
Synchronization of human vital signs, namely the cardiac cycle and respiratory excursions, is necessary during magnetic resonance imaging of the cardiovascular system and the abdominal cavity to achieve optimal image quality with minimized artifacts. This review summarizes techniques currently available in clinical practice, as well as methods under development, outlines the benefits and disadvantages of each approach, and offers some unique solutions for consideration.
- 29 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Reviews in Biomedical Engineering
- Vol. 15 (19373333) , 200-221
Open AccessMonitoring and Synchronization of Cardiac and Respiratory Traces in Magnetic Resonance Imaging: A Review
Synchronization of human vital signs, namely the cardiac cycle and respiratory excursions, is necessary during magnetic resonance imaging of the cardiovascular system and the abdominal cavity to achieve optimal image quality with minimized artifacts. This review summarizes techniques currently available in clinical practice, as well as methods under development, outlines the benefits and disadvantages of each approach, and offers some unique solutions for consideration.
- Open Access
- 3 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 127648-127658
PDMS-FBG-Based Fiber Optic System for Traffic Monitoring in Urban Areas
This article introduces fiber Bragg grating (FBG) system for monitoring selected traffic flow parameters in urban areas. The system is able to monitor traffic density or speed of cars driving in single lane. The proposed system consists of five Bragg gratings encapsulated in Polydimethylsiloxane polymer and is characterized by easy and inexpensive installation in the milled upper layer of the road covered with an asphalt mixture. The results of first operational tests presented in this study include 3978 passing vehicles of various specifications. The system’s vehicle detection success rate is 99.62%. And further, a mean absolute error 1.35 kph and a relative error 2.62% when measuring vehicle speed.
- 3 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 127648-127658
Open AccessPDMS-FBG-Based Fiber Optic System for Traffic Monitoring in Urban Areas
This article introduces fiber Bragg grating (FBG) system for monitoring selected traffic flow parameters in urban areas. The system is able to monitor traffic density or speed of cars driving in single lane. The proposed system consists of five Bragg gratings encapsulated in Polydimethylsiloxane polymer and is characterized by easy and inexpensive installation in the milled upper layer of the road covered with an asphalt mixture. The results of first operational tests presented in this study include 3978 passing vehicles of various specifications. The system’s vehicle detection success rate is 99.62%. And further, a mean absolute error 1.35 kph and a relative error 2.62% when measuring vehicle speed.
- Open Access
- 1 January 2020
- Published by EJournal Publishing in International Journal of Machine Learning and Computing
- Vol. 10 (2) , 368-373
Comparison of Computing Performance of Image Processing on Different HW Platforms
The work describes the evaluation of selected platforms in computing performance on a defined task. The work includes a description of the individual platforms and their hardware equipment. The chosen representatives are from categories of personal computers, embedded devices and industrial controller with on board FPGA. The evaluation of selected platforms is executed by the rising difficulty of given problem by changing the size of input data. In this case, it is the resolution of the image used by the Canny edge detecting algorithm. The result of this work is the relative comparison of the platforms, even with the increase in the volume of data processed by the algorithm. This experiment can be used to simplify architecture and hardware selection in practical applications due to presented performance in account of time complexity of given task.
- 1 January 2020
- Published by EJournal Publishing in International Journal of Machine Learning and Computing
- Vol. 10 (2) , 368-373
Open AccessComparison of Computing Performance of Image Processing on Different HW Platforms
The work describes the evaluation of selected platforms in computing performance on a defined task. The work includes a description of the individual platforms and their hardware equipment. The chosen representatives are from categories of personal computers, embedded devices and industrial controller with on board FPGA. The evaluation of selected platforms is executed by the rising difficulty of given problem by changing the size of input data. In this case, it is the resolution of the image used by the Canny edge detecting algorithm. The result of this work is the relative comparison of the platforms, even with the increase in the volume of data processed by the algorithm. This experiment can be used to simplify architecture and hardware selection in practical applications due to presented performance in account of time complexity of given task.
- Open Access
- 31 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 4149-4170
A Comparison Between Novel FPGA-Based Pad Monitoring System Using Ballistocardiography and the Conventional Systems for Synchronization and Gating of CMRI at 3 Tesla: A Pilot Study
This pilot pre-clinical study demonstrates the applicability of a new type of pneumatic cardiac triggering (PCT) for cardiac imaging. The pilot research compares the novel FPGA-based pad monitoring system for cardiac triggering using ballistocardiography (BCG) with conventional systems based on electrocardiography (ECG) and photoplethysmography (PPG). The implemented system enables cardiac triggering without the need to fix the sensors to the patient’s body. This unique approach has the potential to reduce the preparation time for examination and the examination itself and to increase patient’s comfort. The pilot pre-clinical study was conducted on 10 subjects at the Siemens Prisma 3T MRI Scanner within the CEITEC Multimodal and Functional Imaging Laboratory -Central European Institute of Technology, Masaryk University, upon the approval of the Ethics Committee. In total, 748 peaks (heart beats) were detected, with 7.347 correctly identified as true positive peaks, 140 incorrectly detected as false positive peaks, and 106 missed peaks (false negative). For all subjects, the total accuracy reached 96.31% and F1 score reached 98.18%. The applicability of the proposed BCG system was also analyzed in terms of objective (BRISQUE, NIQE, PIQE) and subjective evaluation of the images by 10 experts. The study compares images from two basic cardiac sequences -TRUE FISP (Free Induction Decay Steady-State Precession) and PSIR (Phase Sensitive Inversion Recovery) sequences. The BCG system achieves comparable results with the most frequently used and most accurate clinical ECG system used as gold standard. The results prove that the BCG signal captured by our new sensor can be used as a substitute for ECG signal during MRI exam with reliability of 97%.
- 31 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 4149-4170
Open AccessA Comparison Between Novel FPGA-Based Pad Monitoring System Using Ballistocardiography and the Conventional Systems for Synchronization and Gating of CMRI at 3 Tesla: A Pilot Study
This pilot pre-clinical study demonstrates the applicability of a new type of pneumatic cardiac triggering (PCT) for cardiac imaging. The pilot research compares the novel FPGA-based pad monitoring system for cardiac triggering using ballistocardiography (BCG) with conventional systems based on electrocardiography (ECG) and photoplethysmography (PPG). The implemented system enables cardiac triggering without the need to fix the sensors to the patient’s body. This unique approach has the potential to reduce the preparation time for examination and the examination itself and to increase patient’s comfort. The pilot pre-clinical study was conducted on 10 subjects at the Siemens Prisma 3T MRI Scanner within the CEITEC Multimodal and Functional Imaging Laboratory -Central European Institute of Technology, Masaryk University, upon the approval of the Ethics Committee. In total, 748 peaks (heart beats) were detected, with 7.347 correctly identified as true positive peaks, 140 incorrectly detected as false positive peaks, and 106 missed peaks (false negative). For all subjects, the total accuracy reached 96.31% and F1 score reached 98.18%. The applicability of the proposed BCG system was also analyzed in terms of objective (BRISQUE, NIQE, PIQE) and subjective evaluation of the images by 10 experts. The study compares images from two basic cardiac sequences -TRUE FISP (Free Induction Decay Steady-State Precession) and PSIR (Phase Sensitive Inversion Recovery) sequences. The BCG system achieves comparable results with the most frequently used and most accurate clinical ECG system used as gold standard. The results prove that the BCG signal captured by our new sensor can be used as a substitute for ECG signal during MRI exam with reliability of 97%.
- Open Access
Alternative Approaches to Vibration Measurement Due to the Blasting Operation: A Pilot Study
As the infrastructure grows, space on the surface in the urban area is diminishing, and the view of the builders is increasingly moving underground. Implementation of underground structures, however, presents a number of problems during construction. One of the primary side effects of tunnel excavation is vibration. These vibrations need to be monitored for potential damage to structures on the surface, and this monitoring is an integral part of any such structure. This paper brings an original pilot comparative study of standard seismic instrumentation with experimentally developed fiber-optic interferometric and acoustic systems for the purpose of monitoring vibration caused by the blasting operation. The results presented show that systems operating on physical principles (other than those previously used) have the potential to be an alternative that will replace the existing costly seismic equipment. The paper presents waveform images and frequency spectra from experimental measurements of the dynamic response of the rock environment, due to blasting operation performed shallowly during the tunnel excavation of a sewer collector. In the time and frequency domain, there is, by comparison, significant agreement both in the character of the waveform images (recording length, blasting operation timing) and in the spectra (bandwidth, dominant maxima).
Open AccessAlternative Approaches to Vibration Measurement Due to the Blasting Operation: A Pilot Study
As the infrastructure grows, space on the surface in the urban area is diminishing, and the view of the builders is increasingly moving underground. Implementation of underground structures, however, presents a number of problems during construction. One of the primary side effects of tunnel excavation is vibration. These vibrations need to be monitored for potential damage to structures on the surface, and this monitoring is an integral part of any such structure. This paper brings an original pilot comparative study of standard seismic instrumentation with experimentally developed fiber-optic interferometric and acoustic systems for the purpose of monitoring vibration caused by the blasting operation. The results presented show that systems operating on physical principles (other than those previously used) have the potential to be an alternative that will replace the existing costly seismic equipment. The paper presents waveform images and frequency spectra from experimental measurements of the dynamic response of the rock environment, due to blasting operation performed shallowly during the tunnel excavation of a sewer collector. In the time and frequency domain, there is, by comparison, significant agreement both in the character of the waveform images (recording length, blasting operation timing) and in the spectra (bandwidth, dominant maxima).
- 13 April 2019
- Published by Springer Nature
- p. 429-438
IoT Approach to Street Lighting Control Using MQTT Protocol
- 13 April 2019
- Published by Springer Nature
- p. 429-438
IoT Approach to Street Lighting Control Using MQTT Protocol
- 8 October 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10801, 14
A comparison of probes based on Bragg grating sensor and microphones for heart sounds measurement
This paper presents the comparison of fibre-optic Bragg Grating Sensor with the commercially available probes for heart sounds measurement based on microphones. The analysis of the sensitivity and specificity was carried out to assess the efficacy of the individual measuring probes. Since fibre-optic sensing uses light in optical fibre rather than electricity, it solves the limitations of electrical sensors such as transmission loss and susceptibility to electromagnetic interference (EMI). Experimental results have shown that Fibre-Optic Bragg Grating Sensor significantly outperforms the devices using the microphones. Moreover, the sensor embedded in polydimethylsiloxane polymer and is fixed on the thorax by means of elastic belt. The material is biocompatible and immune to electromagnetic interference, which is major advantage for the healthcare environment. The probe dimensions are small; therefore, it would be convenient for the patient and easily implemented into clinical practice. Nevertheless, the signal processing methods must be applied to separate the desired signal from the environmental noise.
- 8 October 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10801, 14
A comparison of probes based on Bragg grating sensor and microphones for heart sounds measurement
This paper presents the comparison of fibre-optic Bragg Grating Sensor with the commercially available probes for heart sounds measurement based on microphones. The analysis of the sensitivity and specificity was carried out to assess the efficacy of the individual measuring probes. Since fibre-optic sensing uses light in optical fibre rather than electricity, it solves the limitations of electrical sensors such as transmission loss and susceptibility to electromagnetic interference (EMI). Experimental results have shown that Fibre-Optic Bragg Grating Sensor significantly outperforms the devices using the microphones. Moreover, the sensor embedded in polydimethylsiloxane polymer and is fixed on the thorax by means of elastic belt. The material is biocompatible and immune to electromagnetic interference, which is major advantage for the healthcare environment. The probe dimensions are small; therefore, it would be convenient for the patient and easily implemented into clinical practice. Nevertheless, the signal processing methods must be applied to separate the desired signal from the environmental noise.