DKDaewon Kim

Daewon Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Daewon Kim has a total of 36 co-authors. Here are the top co-authors by number of shared publications:

  • Junsung Park

    Atomic and Molecular Physics Division Center for Astrophysics | Harvard & Smithsonian Cambridge MA USA

    7 shared publications
  • Hanlim Lee

    Professor, Major of Spatial Information Engineering, Division of Earth Environmental System Sciences, Pukyong National University, Busan, Republic of Korea

    5 shared publications
  • Hanlim Lee

    Division of Earth Environmental System Science, Major of Spatial Information Engineering, Pukyong National University, Busan, Republic of Korea

    4 shared publications
  • Hyunkee Hong

    Environmental Satellite Center, National Institute of Environmental Research, Incheon, Republic of Korea

    4 shared publications
  • Jhoon Kim

    Department of Atmospheric Sciences, Yonsei University, Seoul, South Korea

    4 shared publications
  • Wonei Choi

    Division of Earth Environmental System Science, Major of Spatial Information Engineering, Pukyong National University, Busan, Republic of Korea

    4 shared publications

Latest Publications

  • Open Access

    First-time comparison between NO2 vertical columns from Geostationary Environmental Monitoring Spectrometer (GEMS) and Pandora measurements

    by Serin Kim, Daewon Kim, Hyunkee Hong, Lim-Seok Chang, Hanlim Lee, Deok-Rae Kim, Donghee Kim, Jeong-Ah Yu, Dongwon Lee, Ukkyo Jeong, et al.

    The Geostationary Environmental Monitoring Spectrometer (GEMS) is a UV-visible (UV-Vis) spectrometer on board the GEO-KOMPSAT-2B (Geostationary Korea Multi-Purpose Satellite 2B) satellite launched into a geostationary orbit in February 2020. To evaluate the GEMS NO2 total column data, a comparison was carried out using the NO2 vertical column density (VCD) that measured direct sunlight using the Pandora spectrometer system at four sites in Seosan, South Korea, from November 2020 to January 2021. Correlation coefficients between GEMS and Pandora NO2 data at four sites ranged from 0.35 to 0.48, with root mean square errors (RMSEs) from 4.7×1015 to 5.5×1015 molec. cm−2 for a cloud fraction (CF) 15 to 5.0×1015 molec. cm−2 were found with CF 2 in less cloudy conditions. Overall, the GEMS NO2 total column data tended to be lower than the Pandora data, owing to differences in the representative spatial coverage, with a large negative bias under high CF conditions. With a correction for horizontal representativeness in the Pandora measurement coverage, correlation coefficients ranging from 0.69 to 0.81, with RMSEs from 3.2×1015 to 4.9×1015 molec. cm−2, were achieved for CF <0.3, showing a better correlation with the correction than without the correction.


  • Open Access

    Comment on amt-2023-11

    by Serin Kim, Daewon Kim, Hyunkee Hong, Lim-Seok Chang, Hanlim Lee, Deok-Rae Kim, Donghee Kim, Jeong-Ah Yu, Dongwon Lee, Ukkyo Jeong, et al.

    The Geostationary Environmental Monitoring Spectrometer (GEMS) is a UV–visible spectrometer onboard the GEO-KOMPSAT-2B satellite launched into geostationary orbit in February 2020. To evaluate GEMS NO2 column data, comparison was carried out using NO2 vertical column density (VCD) measured using direct-sunlight observations by the Pandora spectrometer system at four sites in Seosan, South Korea, during November 2020 to January 2021. Correlation coefficients between GEMS and Pandora NO2 data at four sites ranged from 0.35 to 0.48, with root mean square errors (RMSEs) from 4.7 × 1015 molec. cm-2 to 5.5 × 1015 molec. cm-2 for cloud fraction (CF) < 0.7. Higher correlation coefficients of 0.62–0.78 with lower RMSEs from 3.3 × 1015 molec. cm-2 to 4.3 × 1015 molec. cm-2 were found with CF < 0.3, indicating the higher sensitivity of GEMS to atmospheric NO2 in less-cloudy conditions. Overall, GEMS NO2 column data tend to be lower than those of Pandora due to differences in representative spatial coverage, with a large negative bias under high-CF conditions. With correction for horizontal representativeness in Pandora measurement coverage, the correlation coefficients range from 0.69 to 0.81 with RMSEs from 3.2 × 1015 molec. cm-2 to 4.9 × 1015 molec. cm-2 were achieved for CF < 0.3, showing the better correlation with the correction than that without the correction.

  • Open Access

    First-time comparison between NO2 vertical columns from GEMS and Pandora measurements

    by Serin Kim, Daewon Kim, Hyunkee Hong, Lim-Seok Chang, Hanlim Lee, Deok-Rae Kim, Donghee Kim, Jeong-Ah Yu, Dongwon Lee, Ukkyo Jeong, et al.

    The Geostationary Environmental Monitoring Spectrometer (GEMS) is a UV–visible spectrometer onboard the GEO-KOMPSAT-2B satellite launched into geostationary orbit in February 2020. To evaluate GEMS NO2 column data, comparison was carried out using NO2 vertical column density (VCD) measured using direct-sunlight observations by the Pandora spectrometer system at four sites in Seosan, South Korea, during November 2020 to January 2021. Correlation coefficients between GEMS and Pandora NO2 data at four sites ranged from 0.35 to 0.48, with root mean square errors (RMSEs) from 4.7 × 1015 molec. cm-2 to 5.5 × 1015 molec. cm-2 for cloud fraction (CF) < 0.7. Higher correlation coefficients of 0.62–0.78 with lower RMSEs from 3.3 × 1015 molec. cm-2 to 4.3 × 1015 molec. cm-2 were found with CF < 0.3, indicating the higher sensitivity of GEMS to atmospheric NO2 in less-cloudy conditions. Overall, GEMS NO2 column data tend to be lower than those of Pandora due to differences in representative spatial coverage, with a large negative bias under high-CF conditions. With correction for horizontal representativeness in Pandora measurement coverage, the correlation coefficients range from 0.69 to 0.81 with RMSEs from 3.2 × 1015 molec. cm-2 to 4.9 × 1015 molec. cm-2 were achieved for CF < 0.3, showing the better correlation with the correction than that without the correction.

  • Open Access

    Investigation of Aerosol Peak Height Effect on PBL and Volcanic Air Mass Factors for SO2 Column Retrieval from Space-Borne Hyperspectral UV Sensors

    by Wonei Choi, Jiwon Yang, Hanlim Lee, Michel Van Roozendael, Ja-Ho Koo, Junsung Park, Daewon Kim

    We investigate the effects of aerosol peak height (APH) and various parameters on the air mass factor (AMF) for SO2 retrieval. Increasing aerosol optical depth (AOD) leads to multiple scattering within the planetary boundary layer (PBL) and an increase in PBL SO2 AMF. However, under high AOD conditions, aerosol shielding effects dominate, which causes the PBL SO2 AMF to decrease with increasing AOD. The height of the SO2 layer and the APH are found to significantly influence the PBL SO2 AMF under high AOD conditions. When the SO2 and aerosol layers are of the same height, aerosol multiple scattering occurs dominantly within the PBL, which leads to an increase in the PBL SO2 AMF. When the APH is greater than the SO2 layer height, aerosol shielding effects dominate, which decreases the PBL SO2 AMF. When the SO2 and aerosol layers are of the same height under low AOD and solar zenith angle (SZA) conditions, increased surface reflectance is found to significantly increase the PBL SO2 AMF. However, high AOD dominates the surface reflectance contribution to PBL SO2 AMF. Under high SZA conditions, Rayleigh scattering contributes to a reduction in the light path length and PBL SO2 AMF. For volcanic SO2 AMF, high SZA enhances the light path length within the volcanic SO2 layer, as well as the volcanic SO2 AMF, because of the negligible photon loss by Rayleigh scattering at high altitudes. High aerosol loading and an APH that is greater than the SO2 peak height lead to aerosol shielding effects, which reduce the volcanic SO2 AMF. The SO2 AMF errors are also quantified as a function of uncertainty in the input data of AOD, APH, and surface reflectance. The SO2 AMF sensitivities and error analysis provided here can be used to develop effective error reduction strategies for satellite-based SO2 retrievals.


  • Open Access

    Development of Raman Lidar for Remote Sensing of CO2 Leakage at an Artificial Carbon Capture and Storage Site

    by Daewon Kim, Hyeongwoo Kang, Jea-Yong Ryu, Seong-Chun Jun, Seong-Taek Yun, SungChul Choi, SunHo Park, MoonSang Yoon, Hanlim Lee

    We developed a Raman lidar system that can remotely detect CO2 leakage and its volume mixing ratio (VMR). The system consists of a laser, a telescope, an optical receiver, and detectors. Indoor CO2 cell measurements show that the accuracy of the Raman lidar is 99.89%. Field measurements were carried out over a four-day period in November 2017 at the Eumsong Environmental Impact Evaluation Test Facility (EIT), Korea, where a CO2 leak was located 0.2 km from the Raman lidar. The results show good agreement between CO2 VMR measured by the Raman lidar system (CO2 VMRRaman LIDAR) and that measured by in situ instruments (CO2 VMRIn-situ). The correlation coefficient (R), mean absolute error (MAE), root mean square error (RMSE), and percentage difference between CO2 VMRIn-situ and CO2 VMRRaman LIDAR are 0.81, 0.27%, 0.37%, and 4.92%, respectively. The results indicate that Raman lidar is an effective tool in detecting CO2 leakage and in measuring CO2 VMR remotely.


  • Open Access

    Retrieval Accuracy of HCHO Vertical Column Density from Ground-Based Direct-Sun Measurement and First HCHO Column Measurement Using Pandora

    by Junsung Park, Hanlim Lee, Jhoon Kim, Jay Herman, Woogyung Kim, Hyunkee Hong, Wonei Choi, Jiwon Yang, Daewon Kim

    In the present study, we investigate the effects of signal to noise (SNR), slit function (FWHM), and aerosol optical depth (AOD) on the accuracy of formaldehyde (HCHO) vertical column density (HCHOVCD) using the ground-based direct-sun synthetic radiance based on differential optical absorption spectroscopy (DOAS). We found that the effect of SNR on HCHO retrieval accuracy is larger than those of FWHM and AOD. When SNR = 650 (1300), FWHM = 0.6, and AOD = 0.2, the absolute percentage difference (APD) between the true HCHOVCD values and those retrieved ranges from 54 (30%) to 5% (1%) for the HCHOVCD of 5.0 × 1015 and 1.1 × 1017 molecules cm−2, respectively. Interestingly, the maximum AOD effect on the HCHO accuracy was found for the HCHOVCD of 3.0 × 1016 molecules cm−2. In addition, we carried out the first ground-based direct-sun measurements in the ultraviolet (UV) wavelength range to retrieve the HCHOVCD using Pandora in Seoul. The HCHOVCD was low at 12:00 p.m. local time (LT) in all seasons, whereas it was high in the morning (10:00 a.m. LT) and late afternoon (4:00 p.m. LT), except in winter. The maximum HCHOVCD values were 2.68 × 1016, 3.19 × 1016, 2.00 × 1016, and 1.63 × 1016 molecules cm−2 at 10:00 a.m. LT in spring, 10:00 a.m. LT in summer, 1:00 p.m. LT in autumn, and 9:00 a.m. LT in winter, respectively. The minimum values of Pandora HCHOVCD were 1.63 × 1016, 2.23 × 1016, 1.26 × 1016, and 0.82 × 1016 molecules cm−2 at around 1:45 p.m. LT in spring, summer, autumn, and winter, respectively. This seasonal pattern of high values in summer and low values in winter implies that photo-oxidation plays an important role in HCHO production. The correlation coefficient (R) between the monthly HCHOVCD values from Pandora and those from the Ozone Monitoring Instrument (OMI) is 0.61, and the slope is 1.25.


  • Open Access

    Estimation of Surface NO2 Volume Mixing Ratio in Four Metropolitan Cities in Korea Using Multiple Regression Models with OMI and AIRS Data

    by Daewon Kim, Hanlim Lee, Hyunkee Hong, Wonei Choi, Yun Gon Lee, Junsung Park

    Surface NO2 volume mixing ratio (VMR) at a specific time (13:45 Local time) (NO2 VMRST) and monthly mean surface NO2 VMR (NO2 VMRM) are estimated for the first time using three regression models with Ozone Monitoring Instrument (OMI) data in four metropolitan cities in South Korea: Seoul, Gyeonggi, Daejeon, and Gwangju. Relationships between the surface NO2 VMR obtained from in situ measurements (NO2 VMRIn-situ) and tropospheric NO2 vertical column density obtained from OMI from 2007 to 2013 were developed using regression models that also include boundary layer height (BLH) from Atmospheric Infrared Sounder (AIRS) and surface pressure, temperature, dew point, and wind speed and direction. The performance of the regression models is evaluated via comparison with the NO2 VMRIn-situ for two validation years (2006 and 2014). Of the three regression models, a multiple regression model shows the best performance in estimating NO2 VMRST and NO2 VMRM. In the validation period, the average correlation coefficient (R), slope, mean bias (MB), mean absolute error (MAE), root mean square error (RMSE), and percent difference between NO2 VMRIn-situ and NO2 VMRST estimated by the multiple regression model are 0.66, 0.41, −1.36 ppbv, 6.89 ppbv, 8.98 ppbv, and 31.50%, respectively, while the average corresponding values for the other two models are 0.75, 0.41, −1.40 ppbv, 3.59 ppbv, 4.72 ppbv, and 16.59%, respectively. All three models have similar performance for NO2 VMRM, with average R, slope, MB, MAE, RMSE, and percent difference between NO2 VMRIn-situ and NO2 VMRM of 0.74, 0.49, −1.90 ppbv, 3.93 ppbv, 5.05 ppbv, and 18.76%, respectively.


  • Open Access

    Long-Range Transport of SO2 from Continental Asia to Northeast Asia and the Northwest Pacific Ocean: Flow Rate Estimation Using OMI Data, Surface in Situ Data, and the HYSPLIT Model

    by Junsung Park, Jaeyong Ryu, Daewon Kim, Jaeho Yeo, Hanlim Lee

    This present study suggests a method to calculate the SO2 flow rate from a source area to receptor areas on a regional scale using Ozone Monitoring Instrument (OMI) SO2 products, surface in situ SO2 data, and the hybrid single particle Lagrangian integrated trajectory (HYSPLIT) model. The method was implemented to calculate the SO2 flow rate from continental Asia to northeast Asia and the Northwest Pacific Ocean. For the high SO2 events when SO2 was transported from continental Asia to Japan via the Korean Peninsula on 22–24 December 2006, the long-range transported SO2 flow rates were 14.0 (21.0) Mg·h−1 OMI·gird−1 at Gangneung (Seoul) in Korea and 4.2 (5.3) Mg·h−1 OMI·gird−1 at Hiroshima (Kumamoto) in Japan. For the long-range transport of SO2 from continental Asia to the Northwest Pacific Ocean on 6–7 October 2008 (9–11 October 2006), the flow rates were 16.1 (16.2) Mg·h−1 OMI·gird−1 at Hokkaido, Japan (Vladivostok, Russia) and 5.6 (16.7) Mg·h−1 OMI·gird−1 at the Aleutian Islands, Northwest Pacific Ocean (Bering Sea). The mean rates of decrease in the SO2 flow rate per 1000 km were also calculated between continental Asia and the receptor areas. Uncertainties in the flow rate estimates were also assessed and discussed.