Gary Liney
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Gary Liney has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Robba Rai
Liverpool and Macarthur Cancer Therapy Centres and Ingham Institute, Sydney, Australia
5 shared publications - Jason Dowling
Commonwealth Scientific and Industrial Research Organisation, Australian E-Health Research Centre, Herston, QLD 4029, Australia
3 shared publications - Lois Holloway
South Western Sydney Clinical School, Faculty of Medicine, UNSW, Sydney, Australia
3 shared publications - David Thwaites
Institute of Medical Physics, School of Physics, University of Sydney, Sydney, Australia
2 shared publications - Paul Keall
The University of Sydney
2 shared publications - Peter B. Greer
University of Newcastle, Newcastle, Australia
2 shared publications
Latest Publications
- Open Access
- 23 May 2023
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 46 (3) , 1015-1021
Clinical validation of MR imaging time reduction for substitute/synthetic CT generation for prostate MRI-only treatment planning
Radiotherapy treatment planning based only on magnetic resonance imaging (MRI) has become clinically achievable. Though computed tomography (CT) is the gold standard for radiotherapy imaging, directly providing the electron density values needed for planning calculations, MRI has superior soft tissue visualisation to guide treatment planning decisions and optimisation. MRI-only planning removes the need for the CT scan, but requires generation of a substitute/synthetic/pseudo CT (sCT) for electron density information. Shortening the MRI imaging time would improve patient comfort and reduce the likelihood of motion artefacts. A volunteer study was previously carried out to investigate and optimise faster MRI sequences for a hybrid atlas-voxel conversion to sCT for prostate treatment planning. The aim of this follow-on study was to clinically validate the performance of the new optimised sequence for sCT generation in a treated MRI-only prostate patient cohort. 10 patients undergoing MRI-only treatment were scanned on a Siemens Skyra 3T MRI as part of the MRI-only sub-study of the NINJA clinical trial (ACTRN12618001806257). Two sequences were used, the standard 3D T2-weighted SPACE sequence used for sCT conversion which has been previously validated against CT, and a modified fast SPACE sequence, selected based on the volunteer study. Both were used to generate sCT scans. These were then compared to evaluate the fast sequence conversion for anatomical and dosimetric accuracy against the clinically approved treatment plans. The average Mean Absolute Error (MAE) for the body was 14.98 ± 2.35 HU, and for bone was 40.77 ± 5.51 HU. The external volume contour comparison produced a Dice Similarity Coefficient (DSC) of at least 0.976, and an average of 0.985 ± 0.004, and the bony anatomy contour comparison a DSC of at least 0.907, and an average of 0.950 ± 0.018. The fast SPACE sCT agreed with the gold standard sCT within an isocentre dose of -0.28% ± 0.16% and an average gamma pass rate of 99.66% ± 0.41% for a 1%/1 mm gamma tolerance. In this clinical validation study, the fast sequence, which reduced the required imaging time by approximately a factor of 4, produced an sCT with similar clinical dosimetric results compared to the standard sCT, demonstrating its potential for clinical use for treatment planning.
- 23 May 2023
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 46 (3) , 1015-1021
Open AccessClinical validation of MR imaging time reduction for substitute/synthetic CT generation for prostate MRI-only treatment planning
Radiotherapy treatment planning based only on magnetic resonance imaging (MRI) has become clinically achievable. Though computed tomography (CT) is the gold standard for radiotherapy imaging, directly providing the electron density values needed for planning calculations, MRI has superior soft tissue visualisation to guide treatment planning decisions and optimisation. MRI-only planning removes the need for the CT scan, but requires generation of a substitute/synthetic/pseudo CT (sCT) for electron density information. Shortening the MRI imaging time would improve patient comfort and reduce the likelihood of motion artefacts. A volunteer study was previously carried out to investigate and optimise faster MRI sequences for a hybrid atlas-voxel conversion to sCT for prostate treatment planning. The aim of this follow-on study was to clinically validate the performance of the new optimised sequence for sCT generation in a treated MRI-only prostate patient cohort. 10 patients undergoing MRI-only treatment were scanned on a Siemens Skyra 3T MRI as part of the MRI-only sub-study of the NINJA clinical trial (ACTRN12618001806257). Two sequences were used, the standard 3D T2-weighted SPACE sequence used for sCT conversion which has been previously validated against CT, and a modified fast SPACE sequence, selected based on the volunteer study. Both were used to generate sCT scans. These were then compared to evaluate the fast sequence conversion for anatomical and dosimetric accuracy against the clinically approved treatment plans. The average Mean Absolute Error (MAE) for the body was 14.98 ± 2.35 HU, and for bone was 40.77 ± 5.51 HU. The external volume contour comparison produced a Dice Similarity Coefficient (DSC) of at least 0.976, and an average of 0.985 ± 0.004, and the bony anatomy contour comparison a DSC of at least 0.907, and an average of 0.950 ± 0.018. The fast SPACE sCT agreed with the gold standard sCT within an isocentre dose of -0.28% ± 0.16% and an average gamma pass rate of 99.66% ± 0.41% for a 1%/1 mm gamma tolerance. In this clinical validation study, the fast sequence, which reduced the required imaging time by approximately a factor of 4, produced an sCT with similar clinical dosimetric results compared to the standard sCT, demonstrating its potential for clinical use for treatment planning.
- 1 July 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 9 (04) , 044005-16
Repeatability and reproducibility of magnetic resonance imaging-based radiomic features in rectal cancer
Purpose: Radiomics of magnetic resonance images (MRIs) in rectal cancer can non-invasively characterize tumor heterogeneity with potential to discover new imaging biomarkers. However, for radiomics to be reliable, the imaging features measured must be stable and reproducible. The aim of this study is to quantify the repeatability and reproducibility of MRI-based radiomic features in rectal cancer.Approach: An MRI radiomics phantom was used to measure the longitudinal repeatability of radiomic features and the impact of post-processing changes related to image resolution and noise. Repeatability measurements in rectal cancers were also quantified in a cohort of 10 patients with test–retest imaging among two observers.Results: We found that many radiomic features, particularly from texture classes, were highly sensitive to changes in image resolution and noise. About 49% of features had coefficient of variations ≤10 % in longitudinal phantom measurements. About 75% of radiomic features in in vivo test–retest measurements had an intraclass correlation coefficient of ≥0.8. We saw excellent interobserver agreement with mean Dice similarity coefficient of 0.95 ± 0.04 for test and retest scans.Conclusions: The results of this study show that even when using a consistent imaging protocol many radiomic features were unstable. Therefore, caution must be taken when selecting features for potential imaging biomarkers.
- 1 July 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 9 (04) , 044005-16
Repeatability and reproducibility of magnetic resonance imaging-based radiomic features in rectal cancer
Purpose: Radiomics of magnetic resonance images (MRIs) in rectal cancer can non-invasively characterize tumor heterogeneity with potential to discover new imaging biomarkers. However, for radiomics to be reliable, the imaging features measured must be stable and reproducible. The aim of this study is to quantify the repeatability and reproducibility of MRI-based radiomic features in rectal cancer.Approach: An MRI radiomics phantom was used to measure the longitudinal repeatability of radiomic features and the impact of post-processing changes related to image resolution and noise. Repeatability measurements in rectal cancers were also quantified in a cohort of 10 patients with test–retest imaging among two observers.Results: We found that many radiomic features, particularly from texture classes, were highly sensitive to changes in image resolution and noise. About 49% of features had coefficient of variations ≤10 % in longitudinal phantom measurements. About 75% of radiomic features in in vivo test–retest measurements had an intraclass correlation coefficient of ≥0.8. We saw excellent interobserver agreement with mean Dice similarity coefficient of 0.95 ± 0.04 for test and retest scans.Conclusions: The results of this study show that even when using a consistent imaging protocol many radiomic features were unstable. Therefore, caution must be taken when selecting features for potential imaging biomarkers.
- 6 July 2021
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 44 (3) , 799-807
Effects of MR imaging time reduction on substitute CT generation for prostate MRI-only treatment planning
The introduction of MRI linear accelerators (MR-linacs) and the increased use of MR imaging in radiotherapy, requires improved approaches to MRI-only radiotherapy. MRI provides excellent soft tissue visualisation but does not provide any electron density information required for radiotherapy dose calculation, instead MRI is registered to CT images to enable dose calculations. MRI-only radiotherapy eliminates registration errors and reduces patient discomfort, workload and cost. Electron density requirements may be addressed in different ways, from manually applying bulk density corrections, to more computationally intensive methods to produce substitute CT datasets (sCT), requiring additional sequences, increasing overall imaging time. Reducing MR imaging time would reduce potential artefacts from intrafraction motion and patient discomfort. The aim of this study was to assess the impact of reducing MR imaging time on a hybrid atlas-voxel sCT conversion for prostate MRI-only treatment planning, considering both anatomical and dosimetric parameters. 10 volunteers were scanned on a Siemens Skyra 3T MRI. Sequences included the 3D T2-weighted (T2-w) SPACE sequence used for sCT conversion as previously validated against CT, along with variations to this sequence in repetition time (TR), turbo factor, and combinations of these to reduce the imaging time. All scans were converted to sCT and were compared to the sCT from the original SPACE sequence, evaluating for anatomical changes and dosimetric differences for a standard prostate VMAT plan. Compared to the previously validated T2-w SPACE sequence, scan times were reduced by up to 80%. The external volume and bony anatomy were compared, with all but one sequence meeting a DICE coefficient of 0.9 or better, with the largest variations occurring at the edges of the external body volume. The generated sCT agreed with the gold standard sCT within an isocentre dose of 1% and a gamma pass rate of 99% for a 1%/1 mm gamma tolerance for all but one sequence. This study demonstrates that the MR imaging sequence time was able to be reduced by approximately 80% with similar dosimetric results.
- 6 July 2021
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 44 (3) , 799-807
Effects of MR imaging time reduction on substitute CT generation for prostate MRI-only treatment planning
The introduction of MRI linear accelerators (MR-linacs) and the increased use of MR imaging in radiotherapy, requires improved approaches to MRI-only radiotherapy. MRI provides excellent soft tissue visualisation but does not provide any electron density information required for radiotherapy dose calculation, instead MRI is registered to CT images to enable dose calculations. MRI-only radiotherapy eliminates registration errors and reduces patient discomfort, workload and cost. Electron density requirements may be addressed in different ways, from manually applying bulk density corrections, to more computationally intensive methods to produce substitute CT datasets (sCT), requiring additional sequences, increasing overall imaging time. Reducing MR imaging time would reduce potential artefacts from intrafraction motion and patient discomfort. The aim of this study was to assess the impact of reducing MR imaging time on a hybrid atlas-voxel sCT conversion for prostate MRI-only treatment planning, considering both anatomical and dosimetric parameters. 10 volunteers were scanned on a Siemens Skyra 3T MRI. Sequences included the 3D T2-weighted (T2-w) SPACE sequence used for sCT conversion as previously validated against CT, along with variations to this sequence in repetition time (TR), turbo factor, and combinations of these to reduce the imaging time. All scans were converted to sCT and were compared to the sCT from the original SPACE sequence, evaluating for anatomical changes and dosimetric differences for a standard prostate VMAT plan. Compared to the previously validated T2-w SPACE sequence, scan times were reduced by up to 80%. The external volume and bony anatomy were compared, with all but one sequence meeting a DICE coefficient of 0.9 or better, with the largest variations occurring at the edges of the external body volume. The generated sCT agreed with the gold standard sCT within an isocentre dose of 1% and a gamma pass rate of 99% for a 1%/1 mm gamma tolerance for all but one sequence. This study demonstrates that the MR imaging sequence time was able to be reduced by approximately 80% with similar dosimetric results.
- Open Access
- 1 April 2021
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 18, 26-33
Multi-parametric magnetic resonance imaging assessment of whole tumour heterogeneity for chemoradiotherapy response prediction in rectal cancer
- 1 April 2021
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 18, 26-33
Open AccessMulti-parametric magnetic resonance imaging assessment of whole tumour heterogeneity for chemoradiotherapy response prediction in rectal cancer
- 24 April 2019
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 92 (1098) , 20190056
Reduced motion and improved rectal dosimetry through endorectal immobilization for prostate stereotactic body radiotherapy
Objective: PROMETHEUS (ACTRN12615000223538) is a multicentre clinical trial investigating the feasibility of 19 Gy in 2 fractions of stereotactic body radiotherapy (SBRT) as a boost technique for p...
- 24 April 2019
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 92 (1098) , 20190056
Reduced motion and improved rectal dosimetry through endorectal immobilization for prostate stereotactic body radiotherapy
Objective: PROMETHEUS (ACTRN12615000223538) is a multicentre clinical trial investigating the feasibility of 19 Gy in 2 fractions of stereotactic body radiotherapy (SBRT) as a boost technique for p...
- Open Access
- 22 April 2019
- Published by Wiley in Medical Physics
- Vol. 46 (7) , 3254-3258
Technical Note: The first live treatment on a 1.0 Tesla inline MRI‐linac
Purpose This work describes the first live imaging and radiation delivery performed on a prototype 1.0 Tesla inline MRI‐Linac system in a rat brain tumour model, which was conducted on 29th January 2019. Methods A human scale 1.0 Tesla MRI‐Linac was adapted to be suitable for animal studies via a specially constructed open 6‐channel receiver radiofrequency (RF) coil. A Fischer rat injected with 9L glioma cells in the right hemisphere was imaged and irradiated at day 11 post surgery as part of a larger cohort survival study. The rat was anaesthetized and positioned at the iscocentre of the MRI‐Linac. Imaging was used to localize the brain and confirm the presence of a tumour following the administration of a gadolinium nanoparticle contrast agent. A single dose of 10 Gy was delivered using a 2.25 x 2.90 cm radiation field covering the whole brain and verified with radiosensitive film in situ. Real‐time imaging was used throughout the irradiation period to monitor the animal and target position. Results The signal‐to‐noise ratio (SNR) measured in the rat brain was 38. Post‐contrast imaging was able to demonstrate a tumour of 5 mm diameter in the upper right hemisphere of the brain approximately 45 minutes after administration of the nanoparticles. The radiation beam had no impact on SNR and images at the rate of 2 Hz were effective in monitoring both respiration and intrafractional motion. In vivo film dosimetry confirmed the intended dose delivery. The total procedure time was 35 minutes. Conclusions We have successfully used MRI guidance to localize and subsequently deliver a radiation field to the whole brain of a rat with a right hemispheric tumour. Real‐time imaging during beam‐on was of sufficient quality to monitor breathing and perform exception gating of the treatment. This represents the first live use of a high field inline MRI‐Linac.
- 22 April 2019
- Published by Wiley in Medical Physics
- Vol. 46 (7) , 3254-3258
Open AccessTechnical Note: The first live treatment on a 1.0 Tesla inline MRI‐linac
Purpose This work describes the first live imaging and radiation delivery performed on a prototype 1.0 Tesla inline MRI‐Linac system in a rat brain tumour model, which was conducted on 29th January 2019. Methods A human scale 1.0 Tesla MRI‐Linac was adapted to be suitable for animal studies via a specially constructed open 6‐channel receiver radiofrequency (RF) coil. A Fischer rat injected with 9L glioma cells in the right hemisphere was imaged and irradiated at day 11 post surgery as part of a larger cohort survival study. The rat was anaesthetized and positioned at the iscocentre of the MRI‐Linac. Imaging was used to localize the brain and confirm the presence of a tumour following the administration of a gadolinium nanoparticle contrast agent. A single dose of 10 Gy was delivered using a 2.25 x 2.90 cm radiation field covering the whole brain and verified with radiosensitive film in situ. Real‐time imaging was used throughout the irradiation period to monitor the animal and target position. Results The signal‐to‐noise ratio (SNR) measured in the rat brain was 38. Post‐contrast imaging was able to demonstrate a tumour of 5 mm diameter in the upper right hemisphere of the brain approximately 45 minutes after administration of the nanoparticles. The radiation beam had no impact on SNR and images at the rate of 2 Hz were effective in monitoring both respiration and intrafractional motion. In vivo film dosimetry confirmed the intended dose delivery. The total procedure time was 35 minutes. Conclusions We have successfully used MRI guidance to localize and subsequently deliver a radiation field to the whole brain of a rat with a right hemispheric tumour. Real‐time imaging during beam‐on was of sufficient quality to monitor breathing and perform exception gating of the treatment. This represents the first live use of a high field inline MRI‐Linac.
- 1 November 2018
- Published by Elsevier in Clinical Oncology
- Vol. 30 (11) , 686-691
MRI-Linear Accelerator Radiotherapy Systems
- 1 November 2018
- Published by Elsevier in Clinical Oncology
- Vol. 30 (11) , 686-691
MRI-Linear Accelerator Radiotherapy Systems