ETEiichi Tanaka

Eiichi Tanaka

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Eiichi Tanaka has a total of 47 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of Androgen Deprivation Therapy on Other-Cause of Mortality in Elderly Patients with Clinically Localized Prostate Cancer Treated with Modern Radiotherapy: Is There a Negative Impact?

    by Hideya Yamazaki, Koji Masui, Gen Suzuki, Satoaki Nakamura, Norihiro Aibe, Daisuke Shimizu, Kei Yamada, Koji Okihara, Takumi Shiraishi, Tadayuki Kotsuma, et al.

    The influence of androgen deprivation therapy (ADT) on other-cause of mortality (OCM) was investigated in patients with localized prostate cancer treated with modern high-dose radiotherapy. A retrospective review was conducted on 1125 patients with localized prostate cancer treated with high-dose radiotherapy, including image-guided, intensity-modulated radiotherapy or brachytherapy with a median follow-up of 80.7 months. Overall survival rate was no different between ADT (+) and ADT (−) group in high-, intermediate-, and low-risk groups. OCM was found in 71 patients, consisting of 4% (10/258) in the ADT (−) group and 7% (61/858) in the ADT (+) group (p = 0.0422). The 10-year OCM-free survival rate (OCMFS), if divided by the duration of ADT (ADT naïve (ADT (−)), ADT p = 0.0039) for the ADT (−), ADT p = 0.0189), respectively, whereas it was 90.7%, 89.9%, and 89.0% (p = 0.4716), respectively, in their younger counterparts. In localized prostate cancer patients, treatment with longer ADT for ≥2 years potentially increases the risk of OCM, especially in patients aged ≥75 years.


  • Open Access

    Radiotherapy for Elderly Patients Aged ≥75 Years with Clinically Localized Prostate Cancer—Is There a Role of Brachytherapy?

    by Hideya Yamazaki, Koji Masui, Gen Suzuki, Satoaki Nakamura, Norihiro Aibe, Daisuke Shimizu, Tatsuyuki Nishikawa, Haruumi Okabe, Ken Yoshida, Tadayuki Kotsuma, et al.

    We compared radiotherapy outcomes between 241 elderly patients aged ≥75 years and 867 younger controls (age 0.999) for the low-risk group, 94.6% (92.8% and 100%, p = 0.203) for the intermediate-risk group, and 80.5% (91.2% and 73.6%, p = 0.0195) for the high-risk group. BT showed higher GU toxicity and equivalent GI toxicity to IG-IMRT. In conclusion, elderly patients showed bNED and toxicity that were equivalent to those observed in younger controls, and BT is a plausible option also for healthy elderly with potential to improve bNED, with higher but acceptable GU toxicity.


  • Open Access

    High-Dose-Rate Brachytherapy Monotherapy versus Image-Guided Intensity-Modulated Radiotherapy with Helical Tomotherapy for Patients with Localized Prostate Cancer

    by Hideya Yamazaki, Koji Masui, Gen Suzuki, Satoaki Nakamura, Daisuke Shimizu, Tatsuyuki Nishikawa, Haruumi Okabe, Ken Yoshida, Tadayuki Kotsuma, Eiichi Tanaka, et al.

    The aim of this paper is to compare outcomes between high-dose-rate interstitial brachytherapy (HDR-BT) monotherapy and image-guided intensity-modulated radiotherapy (IG-IMRT) for localized prostate cancer. We examined 353 HDR-BT and 270 IG-IMRT patients. To reduce background selection bias, we used the method of inverse probability treatment weighting (IPTW) with propensity scores. The actuarial five-year biochemical failure-free survival rates were 92.9% and 96.7% (p = 0.1847; p = 0.077 in IPTW) for HDR-BT and IG-IMRT, respectively; they were 100% and 95.8% (p = 0.286) for the low-risk group, 95.6% and 92% (p = 0.42) for the intermediate-risk group, 90.4% and 84.9% (p = 0.1059; p = 0.04 in IPTW) for the high-risk group, and 87.1% and 89.2% (p = 0.3816) for the very-high-risk group. In the assessment of accumulated incidences of grade ≥ 2 toxicity (Common Terminology Criteria for Adverse Events version 4.0) at five years, HDR-BT monotherapy showed higher genitourinary toxicity (11.9%) than IG-IMRT (3.3%) (p < 0.0001). The gastrointestinal toxicity was equivalent for HDR-BT (2.3%) and IG-IMRT (5.5%) (p = 0.063). No Grade 4 or 5 toxicity was detected in either modality. HDR-BT showed higher genitourinary toxicity than IG-IMRT. HDR-BT and IG-IMRT showed equivalent outcomes in low-, intermediate-, and very-high-risk groups. For high-risk patients, HDR-BT showed potential to improve prostate-specific antigen (PSA) control rate compared to IG-IMRT.


    • 1 May 2014
      • Vol. 34  (5) , 2537-40

    A novel minimally invasive technique of high-dose rate image-based intracavitary brachytherapy for endometrial cancer using a single fine and soft, flexible applicator.

    by Koji Masui, Ken Yoshida, Tadashi Takenaka, Tadayuki Kotsuma, Eiichi Tanaka, Keiji Tatsumi, Hideya Yamazaki, Kei Yamada

    We report on a minimally invasive computed tomography (CT)/magnetic resonance imaging (MRI)-based image-guided intracavitary brachytherapy (ICBT) for an elder patient with endometrial cancer, who was unfit for anesthesia, using a fine and soft flexible applicator. The patient was an 82-year-old female. She was identified as having T1bN0M0 (stage IB) tumor, and histological findings revealed grade 2 adenocarcinoma. She was contraindicated for surgery because of advanced age and severe pulmonary emphysema; therefore, she was managed with CT/MRI-based ICBT alone. The total treatment dose was 26 Gy (6.5 Gy per fraction). The dose-volume histogram of the gross tumor volume, the clinical target volume, and organs at risk were calculated. The patient safely completed the ICBT course without pre-medication. Tumor growth was controlled, with complete disappearance after 32 months. No acute or late adverse effects were observed. MRI-guided ICBT can visualize the gross tumor volume in the uterine body, which cannot be detected by CT. We successfully and safely performed minimally invasive CT/MRI-based ICBT without pre-medication in a patient with endometrial cancer with high surgical risks, using a fine and soft, flexible applicator.

    • 1 April 2013
      • Vol. 33  (4) , 1679-84

    Comparison of calculated dose by helical tomotherapy treatment planning machine and measured dose of radiophotoluminescence glass dosimeter in lung lesions using Rando Phantom.

    by Hideya Yamazaki, Kazuki Iwama, Takuya Nishimura, Yasunori Iwai, Norihiro Aibe, Tadashi Takenaka, Shunsuke Miyake, Eiichi Tanaka, Ken Yoshida, Yoshitaka Oota, et al.

    To examine the compatibility of the measured and calculated dose for the treatment of lung lesions by helical tomotherapy. The administered dose was measured a total of 55 times at 22 points with a radiophotoluminescence glass dosimeter (RPLGD) inserted in the position of an anthropomorphic Rando Phantom. Two Gy were prescribed and calculated with a tomotherapy planning machine for a 3-cm diameter spherical planning target volume (PTV) created in the lung area. Compatibility (measured dose/calculated dose and σ value=(D(meas)-D(calc))/D(prescribed)) × 100 (%)) was analyzed according to dosimeter location. Deviations between measured and calculated doses for the lung lesion were within 4% for planning target volume, indicating that adequate dose delivery to the PTV was achievable. On the other hand, we found dose deviations up to 15% for the lower prescribed dose range (64% or less) for the measured dose/calculated comparison and a 6% deviation according to the σ value in or near inhomogeneous tissue. Although the measured dose satisfied the clinical requirement in almost all areas including PTV, we should note that there may be discrepancies between expected calculated dose and irradiated dose in or near inhomogeneous area.


    • 6 February 2009
      • Vol. 28, 3913-20

    Reduction of irradiation volume and toxicities with 3-D radiotherapy planning over conventional radiotherapy for prostate cancer treated with long-term hormonal therapy.

    by Hideya Yamazaki, Kinji Nishiyama, Eiichi Tanaka, Osamu Maeda, Norio Meguro, Toshiaki Kinouchi, Michiyuki Usami, Kenichi Kakimoto, Yutaka Ono, Tsunehiko Nishimura

    As hormonal therapy has an influence not only on outcome but also on toxicities, we compare the efficacy of three-dimensional radiotherapy planning (3D-RTP) and of conventional radiotherapy (Conv-RT) in association with long-term hormonal therapy in reducing toxicity of treatment. A retrospective case-control study was performed comparing the frequency of radiation toxicity between 63 Conv-RT and 52 3D-RTP patients with locally advanced prostate cancer (intermediate to high risk) treated with combined hormonal therapy. The average duration of neoadjuvant treatment was 7 months (1-38 months) and that of adjuvant treatment was 38 months (4-94 months). Patients were treated with 70 Gy of box field radiotherapy for the same clinical target volume (60 Gy prostate + seminal vesicle and 10 Gy boost to prostate). Treatment volumes (= X(RL) x Y(SI) x X(AP), where X(RL) = right left length of anterior-posterior portals, X(AP) = anterior posterior length of lateral portals and Y(SI) = superior inferior length of anterior-posterior portals) were significantly smaller in the 3D-RTP group (630 +/- 130 cm3) than in the Conv-RT group (1036 +/- 223 cm3) (p < 0.0001). Acute side-effects in urological tracts (GU) were associated with XRL (p = 0.02), Y(SI) (p = 0.008) and treatment technique (Conv-RT vs. 3D-RTP: p = 0.01). The frequency of acute gastrointestinal tract (GI) toxicity was associated with X(RL) (p = 0.02), X(AP) (p = 0.03). Late GU toxicities were associated with YAP (p = 0.02) and X(RL) (p = 0.03). Treatment technique was the determinant of late GI toxicities (p = 0.03). Frequency of late GI toxicities of G2 or more was reduced from 35% in the Conv-RT group to 15% in the 3D-RTP group (p = 0.03, odds ratio = 0.43). Patients with late GI toxicity received longer periods (39 +/- 19 months) of adjuvant hormonal therapy than the patients without (31 +/- 18 months, p = 0.04). Prostate-specific antigen (PSA) failure-free survival rates at 3 years were 92% for the 3D-RTP group and 90% for the Conv-RT group (73% at 5 years, 67% at 10 years). Overall survival rates were 97% (3-year), 91% (5-year), and 91% (10-year) in the Conv-RT group, compared to 100% at 3 years in the 3D-RTP group. Long-term hormonal therapy has the potential to improve outcome but induce late GI toxicity. 3D-RTP simultaneously reduced treatment volume and frequency of acute urinary and late GI toxicities even with long-term hormonal therapy.


    • 19 August 2007
      • Vol. 27, 2965-71

    Dummy run for a phase II multi-institute trial of chemoradiotherapy for unresectable pancreatic cancer: inter-observer variance in contour delineation.

    by Hideya Yamazaki, Kinji Nishiyama, Eiichi Tanaka, Keiichiro Koiwai, Naoto Shikama, Yoshinori Ito, Satoko Arahira, Tetsuro Tamamoto, Toru Shibata, Yoshio Tamaki, et al.

    The aim of this study was to examine the interobserver variance in delineating the contour of unresectable pancreatic cancer for chemoradiotherapy. CT images of two cases of unresectable pancreatic tumors (head and body cancer) were sent to eight radiation therapy facilities in a CD-ROM. Gross tumor volume (GTV) and planning target volume (PTV) were delineated using the radiotherapy treatment planning system (RTP) of the respective facilities. The mean and variance of the GTV and PTV of 11 plans by the eight facilities were analyzed. The respective mean volumes of the GTV of pancreatic head and body cancer cases were 34.8 cm3 (SD, 30.4; median, 31.8; range, 13.5-122 cm3) and 73.4 cm3 (SD, 28.1; median, 67.9; range, 46.3-152 cm3). The ratios of the largest to the smallest contoured GTV were 9 and 3, respectively. The corresponding average volumes of PTV were 148 cm3 (SD, 84.3; median, 129; range, 69.6-363 cm3) and 240 cm3 (SD, 79.8; median, 227; range, 148-420 cm3). The ratios of the largest to the smallest contoured volume were 5 and 2.8 for PTV delineation, respectively. Dummy run using CD-ROM is possible on a multi-institute scale but also disclosed interobserver variance. Unified protocol interpretation to reduce inter-observer variance is therefore essential for successful multi-institute clinical trials.