Richard Everly
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Richard Everly has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Stephen Edward Saddow
Department of Electrical Engineering, University of South Florida, 4202 East Fowler Avenue, ENB118, Tampa, FL 33620, USA
3 shared publications - Christopher L. Frewin
Department of Bioengineering, University of Texas at Dallas, Dallas, TX 75080, USA
2 shared publications - Evans K. Bernardin
Department of Biomedical Engineering, University of South Florida, Tampa, FL 33620, USA
2 shared publications - Jawad Ul Hassan
Linköping University
2 shared publications - Ashok Kumar
Physics Department, Tezpur University, Napaam, Assam - 784 028, Tezpur, Assam, 784028, INDIA
1 shared publication - Chenyin Feng
Institute of Microelectronics and Integrated Circuits, School of Microelectronics, Hubei University 1 , Wuhan 430062
1 shared publication
Latest Publications
- Open Access
- 13 July 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (7) , 821
A Flexible a-SiC-Based Neural Interface Utilizing Pyrolyzed-Photoresist Film (C) Active Sites
Carbon containing materials, such as graphene, carbon-nanotubes (CNT), and graphene oxide, have gained prominence as possible electrodes in implantable neural interfaces due to their excellent conductive properties. While carbon is a promising electrochemical interface, many fabrication processes are difficult to perform, leading to issues with large scale device production and overall repeatability. Here we demonstrate that carbon electrodes and traces constructed from pyrolyzed-photoresist-film (PPF) when combined with amorphous silicon carbide (a-SiC) insulation could be fabricated with repeatable processes which use tools easily available in most semiconductor facilities. Directly forming PPF on a-SiC simplified the fabrication process which eliminates noble metal evaporation/sputtering and lift-off processes on small features. PPF electrodes in oxygenated phosphate buffered solution at pH 7.4 demonstrated excellent electrochemical charge storage capacity (CSC) of 14.16 C/cm2, an impedance of 24.8 ± 0.4 kΩ, and phase angle of −35.9 ± 0.6° at 1 kHz with a 1.9 kµm2 recording site area.
- 13 July 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (7) , 821
Open AccessA Flexible a-SiC-Based Neural Interface Utilizing Pyrolyzed-Photoresist Film (C) Active Sites
Carbon containing materials, such as graphene, carbon-nanotubes (CNT), and graphene oxide, have gained prominence as possible electrodes in implantable neural interfaces due to their excellent conductive properties. While carbon is a promising electrochemical interface, many fabrication processes are difficult to perform, leading to issues with large scale device production and overall repeatability. Here we demonstrate that carbon electrodes and traces constructed from pyrolyzed-photoresist-film (PPF) when combined with amorphous silicon carbide (a-SiC) insulation could be fabricated with repeatable processes which use tools easily available in most semiconductor facilities. Directly forming PPF on a-SiC simplified the fabrication process which eliminates noble metal evaporation/sputtering and lift-off processes on small features. PPF electrodes in oxygenated phosphate buffered solution at pH 7.4 demonstrated excellent electrochemical charge storage capacity (CSC) of 14.16 C/cm2, an impedance of 24.8 ± 0.4 kΩ, and phase angle of −35.9 ± 0.6° at 1 kHz with a 1.9 kµm2 recording site area.
- Open Access
- 10 September 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (9) , 451
Correction: Bernardin E.K.; et al. Demonstration of a Robust All-Silicon-Carbide Intracortical Neural Interface. Micromachines, 2018, 9, 412
The authors would like to indicate the following financial support they received to the Acknowledgement Section of their published paper
- 10 September 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (9) , 451
Open AccessCorrection: Bernardin E.K.; et al. Demonstration of a Robust All-Silicon-Carbide Intracortical Neural Interface. Micromachines, 2018, 9, 412
The authors would like to indicate the following financial support they received to the Acknowledgement Section of their published paper
- Open Access
- 18 August 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (8) , 412
Demonstration of a Robust All-Silicon-Carbide Intracortical Neural Interface
Intracortical neural interfaces (INI) have made impressive progress in recent years but still display questionable long-term reliability. Here, we report on the development and characterization of highly resilient monolithic silicon carbide (SiC) neural devices. SiC is a physically robust, biocompatible, and chemically inert semiconductor. The device support was micromachined from p-type SiC with conductors created from n-type SiC, simultaneously providing electrical isolation through the resulting p-n junction. Electrodes possessed geometric surface area (GSA) varying from 496 to 500 K μm2. Electrical characterization showed high-performance p-n diode behavior, with typical turn-on voltages of ~2.3 V and reverse bias leakage below 1 nArms. Current leakage between adjacent electrodes was ~7.5 nArms over a voltage range of −50 V to 50 V. The devices interacted electrochemically with a purely capacitive relationship at frequencies less than 10 kHz. Electrode impedance ranged from 675 ± 130 kΩ (GSA = 496 µm2) to 46.5 ± 4.80 kΩ (GSA = 500 K µm2). Since the all-SiC devices rely on the integration of only robust and highly compatible SiC material, they offer a promising solution to probe delamination and biological rejection associated with the use of multiple materials used in many current INI devices.
- 18 August 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (8) , 412
Open AccessDemonstration of a Robust All-Silicon-Carbide Intracortical Neural Interface
Intracortical neural interfaces (INI) have made impressive progress in recent years but still display questionable long-term reliability. Here, we report on the development and characterization of highly resilient monolithic silicon carbide (SiC) neural devices. SiC is a physically robust, biocompatible, and chemically inert semiconductor. The device support was micromachined from p-type SiC with conductors created from n-type SiC, simultaneously providing electrical isolation through the resulting p-n junction. Electrodes possessed geometric surface area (GSA) varying from 496 to 500 K μm2. Electrical characterization showed high-performance p-n diode behavior, with typical turn-on voltages of ~2.3 V and reverse bias leakage below 1 nArms. Current leakage between adjacent electrodes was ~7.5 nArms over a voltage range of −50 V to 50 V. The devices interacted electrochemically with a purely capacitive relationship at frequencies less than 10 kHz. Electrode impedance ranged from 675 ± 130 kΩ (GSA = 496 µm2) to 46.5 ± 4.80 kΩ (GSA = 500 K µm2). Since the all-SiC devices rely on the integration of only robust and highly compatible SiC material, they offer a promising solution to probe delamination and biological rejection associated with the use of multiple materials used in many current INI devices.