Jun Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jun Chen has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Caiqian Yang
School of Civil Engineering, Southeast University, Nanjing 210096, People’s Republic of China
3 shared publications - Junshi Li
School of Civil Engineering, Xiangtan University, Xiangtan 411105, China
2 shared publications - Bai Zhang
School of Civil and Environmental Engineering Changsha University of Science and Technology Changsha China
1 shared publication - Faxing Ding
School of Civil Engineering, Central South University, Changsha, China
1 shared publication - Feng Wen
School of Civil Engineering, Xiangtan University, Xiangtan 411105, China
1 shared publication - Fu Xu
College of Civil Engineering, Xiangtan University, Xiangtan 411105, China
1 shared publication
Latest Publications
- Open Access
Experimental Study of Bridge Expansion Joint Damage Based on Natural Frequency
In this paper, three studies on modal bridge expansion joints were conducted through experiments. The advantages and disadvantages of acceleration and fiber optic strain sensors in the tested modal expansion joints were compared. Secondly, the variation in the natural frequency of the modal bridge expansion joints at different concrete curing periods was investigated. Finally, the effect of damage on natural frequency in different parts (the center beam, the support bar, and concrete in the anchorage zone) of the modal bridge expansion joint was analyzed. For this purpose, three specimens were cast, each with six damage states. Manual methods damaged the specimens. An impact hammer was used to excite the corresponding parts of the different components. The results showed that the acceleration sensor is optimal for the modal bridge expansion joint test. The specimen’s natural frequency increased with the curing time’s growth. The natural frequency increased by 10 Hz from day 3 to day 28 of curing. With the gradual increase in damage, the natural frequencies of the center beam and support bar showed a gradual decreasing trend. The damage to the concrete in the anchorage zone caused less significant changes in the natural frequency, but the overall natural frequency still had a decreasing trend. The sensitivity of each frequency to the damage was different in different parts.
Open AccessExperimental Study of Bridge Expansion Joint Damage Based on Natural Frequency
In this paper, three studies on modal bridge expansion joints were conducted through experiments. The advantages and disadvantages of acceleration and fiber optic strain sensors in the tested modal expansion joints were compared. Secondly, the variation in the natural frequency of the modal bridge expansion joints at different concrete curing periods was investigated. Finally, the effect of damage on natural frequency in different parts (the center beam, the support bar, and concrete in the anchorage zone) of the modal bridge expansion joint was analyzed. For this purpose, three specimens were cast, each with six damage states. Manual methods damaged the specimens. An impact hammer was used to excite the corresponding parts of the different components. The results showed that the acceleration sensor is optimal for the modal bridge expansion joint test. The specimen’s natural frequency increased with the curing time’s growth. The natural frequency increased by 10 Hz from day 3 to day 28 of curing. With the gradual increase in damage, the natural frequencies of the center beam and support bar showed a gradual decreasing trend. The damage to the concrete in the anchorage zone caused less significant changes in the natural frequency, but the overall natural frequency still had a decreasing trend. The sensitivity of each frequency to the damage was different in different parts.
- Open Access
Sound Damage Detection of Bridge Expansion Joints Using a Support Vector Data Description
A novel method is proposed for the damage identification of modal bridge expansion joints (MBEJs) based on sound signals. Two modal bridge expansion joint specimens were fabricated to simulate healthy and damaged states. A microphone was used to collect the impact signals from different specimens. The wavelet packet energy ratio of the sound signal was used to identify the difference in specimen state. Firstly, the wavelet packet energy ratio was used to establish the feature vectors, which were reduced dimensionality using principal component analysis. Subsequently, a support vector data description model was established to detect the difference in the signals. The identification effects of three parameter optimization methods (particle swarm optimization, genetic algorithm optimization, and Bayesian optimization) were compared. The results showed that the wavelet packet energy ratio of sound signals could effectively distinguish the state of the support bar. The support vector data description of Bayesian optimization worked best, and the proposed method could successfully detect damage to the support bar of MBEJs with an accuracy of 99%.
Open AccessSound Damage Detection of Bridge Expansion Joints Using a Support Vector Data Description
A novel method is proposed for the damage identification of modal bridge expansion joints (MBEJs) based on sound signals. Two modal bridge expansion joint specimens were fabricated to simulate healthy and damaged states. A microphone was used to collect the impact signals from different specimens. The wavelet packet energy ratio of the sound signal was used to identify the difference in specimen state. Firstly, the wavelet packet energy ratio was used to establish the feature vectors, which were reduced dimensionality using principal component analysis. Subsequently, a support vector data description model was established to detect the difference in the signals. The identification effects of three parameter optimization methods (particle swarm optimization, genetic algorithm optimization, and Bayesian optimization) were compared. The results showed that the wavelet packet energy ratio of sound signals could effectively distinguish the state of the support bar. The support vector data description of Bayesian optimization worked best, and the proposed method could successfully detect damage to the support bar of MBEJs with an accuracy of 99%.
- Open Access
Behavior of an Advanced Bolted Shear Connector in Prefabricated Steel-Concrete Composite Beams
The high-strength bolt shear connector in prefabricated concrete slab has advantages in applications as it reduces time during the construction of steel-concrete composite building structures and bridges. In this research, an innovative and advanced bolt shear connector in steel-concrete composite structures is proposed. To investigate the fundamental mechanical behavior and the damage form, 22 static push-off tests were conducted with consideration of different bolt dimensions, the reserved hole constraint condition, and the dimension of slab holes. A finite element (FE) model was established and verified by using test results, and then the model was utilized to investigate the influence of concrete strength, bolt dimension, yield strength, bolt pretension, as well as length-to-diameter ratio of high strength bolts on the performances of shear connectors. On the basis of FE simulation and test results, new design formulas for the calculation of shear resistance behavior were proposed, and comparisons were made with current standards, including AISC, EN 1994-1-1, GB 50017-2017, and relevant references, to check the calculation efficiency. It is confirmed that the proposed equation is in better agreement with the experimental results.
Open AccessBehavior of an Advanced Bolted Shear Connector in Prefabricated Steel-Concrete Composite Beams
The high-strength bolt shear connector in prefabricated concrete slab has advantages in applications as it reduces time during the construction of steel-concrete composite building structures and bridges. In this research, an innovative and advanced bolt shear connector in steel-concrete composite structures is proposed. To investigate the fundamental mechanical behavior and the damage form, 22 static push-off tests were conducted with consideration of different bolt dimensions, the reserved hole constraint condition, and the dimension of slab holes. A finite element (FE) model was established and verified by using test results, and then the model was utilized to investigate the influence of concrete strength, bolt dimension, yield strength, bolt pretension, as well as length-to-diameter ratio of high strength bolts on the performances of shear connectors. On the basis of FE simulation and test results, new design formulas for the calculation of shear resistance behavior were proposed, and comparisons were made with current standards, including AISC, EN 1994-1-1, GB 50017-2017, and relevant references, to check the calculation efficiency. It is confirmed that the proposed equation is in better agreement with the experimental results.
- 1 November 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 144 (11)
Bond Performance between Slightly Corroded Steel Bar and Concrete after Exposure to High Temperature
Bond-slip characteristics of slightly corroded (less than 2% mass loss) reinforcing steel bars embedded in concrete were investigated with pull-out tests conducted after exposure to high temperature and subsequent cooling. Twenty-five scenarios consisting of five corrosion levels (0.0%, 0.5%, 1.0%, 1.5%, and 2.0% corrosion loss) and five exposed temperatures (20°C, 200°C, 400°C, 600°C, and 800°C) were tested. The results indicate that the slight corrosion of the reinforcement not only affects the bond performance of concrete and steel bars but also influences their reaction to elevated temperature before the exposure temperature exceeds 400°C. The effect of slight corrosion on bond-mechanics behavior was eliminated by the dramatic decrease in concrete strength and significantly different thermal expansion between concrete and steel as the exposure temperature reached 600°C.
- 1 November 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 144 (11)
Bond Performance between Slightly Corroded Steel Bar and Concrete after Exposure to High Temperature
Bond-slip characteristics of slightly corroded (less than 2% mass loss) reinforcing steel bars embedded in concrete were investigated with pull-out tests conducted after exposure to high temperature and subsequent cooling. Twenty-five scenarios consisting of five corrosion levels (0.0%, 0.5%, 1.0%, 1.5%, and 2.0% corrosion loss) and five exposed temperatures (20°C, 200°C, 400°C, 600°C, and 800°C) were tested. The results indicate that the slight corrosion of the reinforcement not only affects the bond performance of concrete and steel bars but also influences their reaction to elevated temperature before the exposure temperature exceeds 400°C. The effect of slight corrosion on bond-mechanics behavior was eliminated by the dramatic decrease in concrete strength and significantly different thermal expansion between concrete and steel as the exposure temperature reached 600°C.