Behrad Golshani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Behrad Golshani has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Cyrus P. Bateni
Department of Radiology, UC Davis Health
1 shared publication - Kambiz Motamedi
Department of Radiology, University of California, Los Angeles Medical Center, Los Angeles, USA
1 shared publication - Leanne L. Seeger
Radiology, David Geffen School of Medicine at University of California Los Angeles, Los Angeles, USA
1 shared publication Sara Bamrungchart
Radiology, University of California Davis School of Medicine, Bangkok, THA
1 shared publication- Scott D. Nelson
University of California, Los Angeles (UCLA)
1 shared publication - Steven Kwong
Radiology, David Geffen School of Medicine at University of California Los Angeles, Los Angeles, USA
1 shared publication
Latest Publications
- Open Access
- 27 December 2018
- Published by Springer Nature in Cureus
- Vol. 10 (12) , e3784
Intraneural Hemangioma: Case Report of a Rare Tibial Nerve Lesion
An intraneural hemangioma is a rare, benign mesodermal lesion. We present a case of a three-year-old female with the inability to straighten her right knee and fullness over the right popliteal fossa for one year. Magnetic resonance imaging (MRI) demonstrated a T2 hyperintense lesion of the popliteal fossa, within the tibial nerve. The patient underwent an uncomplicated right knee excisional biopsy, which confirmed the diagnosis of an intraneural hemangioma. Although rare, an intraneural hemangioma should be considered in the differential diagnosis of a soft tissue lesion located in the expected course of a peripheral nerve.
- 27 December 2018
- Published by Springer Nature in Cureus
- Vol. 10 (12) , e3784
Open AccessIntraneural Hemangioma: Case Report of a Rare Tibial Nerve Lesion
An intraneural hemangioma is a rare, benign mesodermal lesion. We present a case of a three-year-old female with the inability to straighten her right knee and fullness over the right popliteal fossa for one year. Magnetic resonance imaging (MRI) demonstrated a T2 hyperintense lesion of the popliteal fossa, within the tibial nerve. The patient underwent an uncomplicated right knee excisional biopsy, which confirmed the diagnosis of an intraneural hemangioma. Although rare, an intraneural hemangioma should be considered in the differential diagnosis of a soft tissue lesion located in the expected course of a peripheral nerve.
- Open Access
- 1 September 2018
- Published by Springer Nature in Cureus
- Vol. 10 (9) , e3262
Radiographic Evaluation of Meniscal Extrusion
Background Magnetic resonance imaging (MRI) is well established as the preferred noninvasive tool for meniscal evaluation. To our knowledge, there has been no study examining the utility of diagnosing meniscal extrusion from radiography alone. We hypothesize that with appropriate window settings, meniscal extrusion may be diagnosed on radiography with high sensitivity and specificity. Materials and methods We included 190 patients with MRI of the knee performed within three months of knee radiography. As defined within the literature, we utilized the MRI criteria of meniscal extrusion as meniscal tissue extending 3 mm or greater beyond the tibial plateau, excluding osteophytes. Two attending radiologists blindly and independently identified the absence or presence, in millimeters, of medial meniscal extrusion on plain film radiography. Kappa test and Pearson correlation coefficient were calculated to assess the extent of inter-reader agreement and correlation. Sensitivity and specificity were calculated for each reader, assuming the concurrent MRI served as the gold standard. Results Ninety-six patients had medial meniscal extrusion and 94 had no medial extrusion by MRI. Kappa test for inter-reader agreement = 0.61. Pearson coefficient for inter-reader measurement correlation = 0.69. Reader A had sensitivity of 0.59 (95% CI 0.49-0.69) and specificity of 0.88 (95% CI 0.79-0.94). Reader B had sensitivity of 0.61 (95% CI 0.51-0.71) and specificity of 0.85 (95% CI 0.76-0.91). Conclusion There is substantial inter-reader agreement and high correlation of meniscal extrusion measurement between readers. Our results suggest that while radiographs have low sensitivity for evaluation of meniscal extrusion, their high specificity may be of clinical utility.
- 1 September 2018
- Published by Springer Nature in Cureus
- Vol. 10 (9) , e3262
Open AccessRadiographic Evaluation of Meniscal Extrusion
Background Magnetic resonance imaging (MRI) is well established as the preferred noninvasive tool for meniscal evaluation. To our knowledge, there has been no study examining the utility of diagnosing meniscal extrusion from radiography alone. We hypothesize that with appropriate window settings, meniscal extrusion may be diagnosed on radiography with high sensitivity and specificity. Materials and methods We included 190 patients with MRI of the knee performed within three months of knee radiography. As defined within the literature, we utilized the MRI criteria of meniscal extrusion as meniscal tissue extending 3 mm or greater beyond the tibial plateau, excluding osteophytes. Two attending radiologists blindly and independently identified the absence or presence, in millimeters, of medial meniscal extrusion on plain film radiography. Kappa test and Pearson correlation coefficient were calculated to assess the extent of inter-reader agreement and correlation. Sensitivity and specificity were calculated for each reader, assuming the concurrent MRI served as the gold standard. Results Ninety-six patients had medial meniscal extrusion and 94 had no medial extrusion by MRI. Kappa test for inter-reader agreement = 0.61. Pearson coefficient for inter-reader measurement correlation = 0.69. Reader A had sensitivity of 0.59 (95% CI 0.49-0.69) and specificity of 0.88 (95% CI 0.79-0.94). Reader B had sensitivity of 0.61 (95% CI 0.51-0.71) and specificity of 0.85 (95% CI 0.76-0.91). Conclusion There is substantial inter-reader agreement and high correlation of meniscal extrusion measurement between readers. Our results suggest that while radiographs have low sensitivity for evaluation of meniscal extrusion, their high specificity may be of clinical utility.