Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


John A. M. Ramshaw has a total of 550 co-authors. Here are the top co-authors by number of shared publications:

  • Jerome A. Werkmeister

    CSIRO Manufacturing, Bayview Avenue, Clayton, Victoria 3169, Australia

    50 shared publications
  • Veronica Glattauer

    CSIRO Manufacturing, Bayview Avenue, Clayton, VIC 3169, Australia

    28 shared publications
  • Jacinta F. White

    CSIRO Manufacturing, Bayview Avenue, Clayton, VIC 3169, Australia

    18 shared publications
  • Barbara Brodsky

    Department of Biochemistry, University of Medicine and Dentistry of New Jersey-Robert Wood Johnson Medical School, 675 Hoes Lane, Piscataway, NJ 08854, USA

    15 shared publications
  • Yong Y. Peng

    CSIRO Manufacturing, Bayview Avenue, Clayton, Victoria 3169, Australia

    13 shared publications
  • Alan Kirkpatrick

    Department of Biochemistry, University of Medicine and Dentistry of New Jersey, Piscataway, New Jersey 08852, and CSIRO Molecular and Health Technologies, Bayview Avenue, Clayton, Victoria 3169, Australia

    11 shared publications

Latest Publications

  • Open Access

    Progress on production of collagen-like proteins by expression in Escherichia coli

    by John A.M. Ramshaw, Veronica Glattauer, Jerome A Werkmeister

    The use of E. coli for the expression of various collagen-like triple helical protein constructs has continued to develop significantly, and certain commercially made proteins are now available. The use of auxotroph designs to assist in the expression of hydroxylated proteins is an important development. A range of other new constructs have been described, including those that contain a segment of a natural collagen sequence and those that are based on collagen-like proteins from prokaryotes, especially the Scl2 protein from Streptococcus pyogenes. The other constructs that have gained increased attention are those where multiple copies, often 16, of a small native collagen sequence are expressed as tandem repeated sequences, with these being of particular interest for biomedical applications. Ascertaining which construct is being used, however, can create difficulties when the same acronym is used for different constructs, and many are frequently described as ‘humanized’ even though no sequence changes have been included to make the construct resemble a human sequence more closely.


  • Top Cited Papers
    Open Access

    Comprehensive review on collagen extraction from food by-products and waste as a value-added material

    by Nisa V. Salim, Balaraman Madhan, Veronica Glattauer, John A.M. Ramshaw


  • Open Access

    Suitability of Marine- and Porcine-Derived Collagen Type I Hydrogels for Bioprinting and Tissue Engineering Scaffolds

    by Malachy Maher, Veronica Glattauer, Carmine Onofrillo, Serena Duchi, Zhilian Yue, Timothy C. Hughes, John A. M. Ramshaw, Gordon G. Wallace

    Collagens from a wide array of animals have been explored for use in tissue engineering in an effort to replicate the native extracellular environment of the body. Marine-derived biomaterials offer promise over their conventional mammalian counterparts due to lower risk of disease transfer as well as being compatible with more religious and ethical groups within society. Here, collagen type I derived from a marine source (Macruronus novaezelandiae, Blue Grenadier) is compared with the more established porcine collagen type I and its potential in tissue engineering examined. Both collagens were methacrylated, to allow for UV crosslinking during extrusion 3D printing. The materials were shown to be highly cytocompatible with L929 fibroblasts. The mechanical properties of the marine-derived collagen were generally lower than those of the porcine-derived collagen; however, the Young’s modulus for both collagens was shown to be tunable over a wide range. The marine-derived collagen was seen to be a potential biomaterial in tissue engineering; however, this may be limited due to its lower thermal stability at which point it degrades to gelatin.


  • Open Access

    Variation in Hydrogel Formation and Network Structure for Telo-, Atelo- and Methacrylated Collagens

    by Malachy Kevin Maher, Jacinta F. White, Veronica Glattauer, Zhilian Yue, Timothy C. Hughes, John A. M. Ramshaw, Gordon G. Wallace

    As the most abundant protein in the extracellular matrix, collagen has become widely studied in the fields of tissue engineering and regenerative medicine. Of the various collagen types, collagen type I is the most commonly utilised in laboratory studies. In tissues, collagen type I forms into fibrils that provide an extended fibrillar network. In tissue engineering and regenerative medicine, little emphasis has been placed on the nature of the network that is formed. Various factors could affect the network structure, including the method used to extract collagen from native tissue, since this may remove the telopeptides, and the nature and extent of any chemical modifications and crosslinking moieties. The structure of any fibril network affects cellular proliferation and differentiation, as well as the overall modulus of hydrogels. In this study, the network-forming properties of two distinct forms of collagen (telo- and atelo-collagen) and their methacrylated derivatives were compared. The presence of the telopeptides facilitated fibril formation in the unmodified samples, but this benefit was substantially reduced by subsequent methacrylation, leading to a loss in the native self-assembly potential. Furthermore, the impact of the methacrylation of the collagen, which enables rapid crosslinking and makes it suitable for use in 3D printing, was investigated. The crosslinking of the methacrylated samples (both telo- and atelo-) was seen to improve the fibril-like network compared to the non-crosslinked samples. This contrasted with the samples of methacrylated gelatin, which showed little, if any, fibrillar or ordered network structure, regardless of whether they were crosslinked.


  • Open Access

    Issue Information

    by James Anderson, Ahmed El, Ghannam Andrés, Garcia Kevin, Eugene Healy, John A. M. Ramshaw, Shelly Sakiyama, Elbert Mei, Wei Jennifer, West Masayuki, et al.

  • Open Access

    Aberrant activation of Wnt signaling pathway altered osteocyte mineralization

    by Yinghong Zhou, Jinying Lin, Jin Shao, Qiliang Zuo, Shengfang Wang, Annalena Wolff, Dung Trung Nguyen, Llew Rintoul, Zhibin Du, Yuantong Gu, et al.


  • Open Access

    Porous carbon fibers made from collagen derived from an animal by-product

    by N.V. Salim, X. Jin, S. Mateti, H. Lin, V. Glattauer, B. Fox, J.A.M. Ramshaw


  • Modelling of focused ion beam induced increases in sample temperature: a case study of heat damage in biological samples

    by A. Wolff, N. Klingner, W. Thompson, Y. Zhou, J. Lin, Y.Y. Peng, J.A.M. Ramshaw, Y. Xiao

    Summary: Ion beam induced heat damage in soft materials and biological samples is not yet well understood in Focused Ion Beam systems (FIBs). The work presented here discusses the physics behind the ion beam – sample interactions and the effects which lead to increases in sample temperature and potential heat damage. A model by which heat damage can be estimated and which allows parameters to be determined that reduce/prevent heat damage was derived from Fourier's law of heat transfer and compared to finite element simulations, numerical modelling results and experiments. The results suggests that ion beam induced heat damage can be prevented/minimised by reducing the ion beam current (local dose rate), decreasing the beam overlap (reduced local ion dose) and by introducing a blur (increased surface cross‐section area, reduced local dose) while sputtering, patterning or imaging soft material and nonresin‐embedded biological samples using FIBs.Lay description: FIB/SEMs, which combine a scanning electron microscope with a focused ion beam in a single device, have found increasing interest biological research. The device allows to cut samples at precisely selected areas and reveal sub surface information as well as preparing transmission electron microscope samples from bulk materials. Preparing biological samples has proven to be challenging due to the induced heat damage. This work explores the physics behind the sample cutting and proposes a model and a method, based on physical principles which allows the user to estimate the induced heat during the cutting process and to select cutting parameters which avoid heat damage in the sample.


  • Open Access

    Issue Information

    by James M. Anderson, Ahmed El‐Ghannam, Andr Es, Garcia Kevin, Eugene Healy, John A. M. Ramshaw, Shelly Sakiyama, Elbert Mei, Wei Jennifer, West Masayuki, et al.