YMYoshikiyo Moriguchi

Yoshikiyo Moriguchi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yoshikiyo Moriguchi has a total of 45 co-authors. Here are the top co-authors by number of shared publications:

  • Hiroaki Minamide

    Research Institute of Electrical Communication, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai, Miyagi 980-8577, Japan

    4 shared publications
  • Kouji Nawata

    RIKEN Center for Advanced Photonics, RIKEN, 519-1399 Aramaki-aoba, Aoba-ku, Sendai,Miyagi 980-0845, Japan

    4 shared publications
  • Shigenori Nagano

    Topcon Corporation, 75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan

    4 shared publications
  • Yu Tokizane

    RIKEN Center for Advanced Photonics, RIKEN, 519-1399 Aramaki-aoba, Aoba-ku, Sendai,Miyagi 980-0845, Japan

    4 shared publications
  • Masahiro Akiba

    Topcon Corporation, Tokyo, Japan

    3 shared publications
  • Masato Tamura

    Research & Development Division, Topcon Corporation, Itabashi, Japan

    3 shared publications

Latest Publications

  • Exploratory investigation of OCTA-VISTA for longitudinal monitoring of neovascular age-related macular degeneration treatment

    by Fumi Tanaka, Toshihiro Mino, Yoshikiyo Moriguchi, Hidenori Nagahama, Hiroaki Sakai, Masato Tamura, Masahiro Akiba, Hiroshi Enaida

  • Open Access

    Optical Attenuation Coefficient-Based En Face Optical Coherence Tomography Imaging for the Reliable Assessment of the Ellipsoid Zone

    by Hiroaki Sakai, Riku Kuji, Yoshikiyo Moriguchi, Shoko Yamashita, Ayako Takamori, Masato Tamura, Toshihiro Mino, Masahiro Akiba, Hiroshi Enaida

    Objective: This study used optical attenuation coefficient (OAC)-based optical coherence tomography (OCT) en face images to assess the ellipsoid zone (EZ) in the foveal region. Methods: This retrospective, observational, cross-sectional study of 41 healthy volunteers and 34 patients with retinal diseases included imaging data acquired using a prototype swept-source OCT system. EZ en face images were generated from OCT raster scan volumes based on OAC, followed by denoising and binarization to quantify the percentage of EZ structural normality or abnormality relative to the total imaging area. We evaluated the reliability of the OAC-based method compared with the OCT signal intensity-based method in healthy and diseased eyes. In addition, the validated program was applied to patients with various retinal conditions. Results: The estimated normal EZ area in healthy eyes was 96.2 ± 5.6% using the OAC-based method versus 89.3 ± 18.8% for the intensity-based method. The OAC-based method effectively mitigated various artifacts caused by retinal blood vessels and other factors in both healthy and diseased eyes. In a pilot study involving six diseased eyes, the area exhibiting EZ structural abnormalities was 27.5–99.6%. Conclusions: The OAC-based EZ assessment robustly suppressed image artifacts and reliably characterized structural abnormalities in the EZ from OCT volumes.


  • Extended and adjustable field-of-view of variable interscan time analysis by ammonite-scanning swept-source optical coherence tomography angiography

    by Toshihiro Mino, Yoshikiyo Moriguchi, Masato Tamura, Akiko Matsumoto, Atsushi Kubota, Masahiro Akiba, Yunchan Hwang, Shuichi Makita, Yoshiaki Yasuno, Hiroshi Enaida, et al.

    A novel scanning protocol, ammonite scan, is proposed for widefield optical coherence tomography angiography (OCTA) and relative retinal blood flow velocity imaging in the human retina using variable interscan time analysis (VISTA). A repeated circle scan using a 400 kHz swept-source was employed to achieve an interscan time of 1.28 ms. The center of the repeated circular scan continuously moved spirally towards the peripheral region, ensuring an extended and adjustable scan range while preserving the short interscan time. Image artifacts due to eye movement were eliminated via extra motion-correction processing using data redundancy. The relative blood flow velocity in superficial and deep plexus layers was calculated from the VISTA image, and their ratio was used to explore the microvascular flow parameter in the healthy human eye.& COPY; 2023 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement


  • Sensorless astigmatism correction using a variable cross-cylinder for high lateral resolution optical coherence tomography in a human retina

    by Masato Tamura, Yoshikiyo Moriguchi, Shu-Yun Yeh, Akiko Matsumoto, Masahiro Shibutani, Takahiro Asao, Toshihiro Mino, Michiko Nakanishi, Atsushi Kubota, Masahiro Akiba

    High lateral resolution ( ∼ 5 µ m ) optical coherence tomography (OCT) that employs a variable cross-cylinder (VCC) to compensate for astigmatism is presented for visualizing minute structures of the human retina. The VCC and its sensorless optimization process enable ocular astigmatism correction of up to − 5.0 diopter within a few seconds. VCC correction has been proven to increase the signal-to-noise ratio and lateral resolution using a model eye. This process is also validated using the human eye by visualizing the capillary network and human cone mosaic. The proposed method is applicable to existing OCT, making high lateral resolution OCT practical in clinical settings.


  • Open Access

    Injection-seeded terahertz-wave parametric generator with timing stabilized excitation for nondestructive testing applications

    by Hiroaki Minamide, Kouji Nawata, Yoshikiyo Moriguchi, Yuma Takida, Takashi Notake

    An injection-seeded terahertz (THz)-wave parametric generator (is-TPG) with a footprint the size of an A3 paper is presented. We improved the measurement performance of the is-TPG source for nondestructive inspection applications. A high pulse repetition rate up to 70 kHz and a low pulse timing jitter of a few tens of picoseconds, which is approximately one ten-thousandth of the conventional is-TPG, were achieved. THz waves exhibited excellent performance with a maximum average output power of 20 µW, a monochromatic spectrum linewidth of ∼20 GHz, and a frequency tuning range of 1.7–3.0 THz. This was achieved by designing the entire system configuration from the pump laser source to THz-wave generation. A new double-pass all-solid-state optical amplifier was developed with a high gain and low noise using an externally pulse-modulated laser diode (LD) as the master oscillator source. An achromatic optical injection system was developed for the is-TPG with a 40% reduction in the conventional path length. They were housed in a single enclosure in two layers. LDs and optical fiber amplifiers could be rack-mounted, and the outputs were delivered to the housing via optical fibers. The developed THz-wave source performed nondestructive imaging of a human hair sample fixed with Scotch tape on a test pattern in an envelope by irradiating 2.1 THz waves. A clearly recognizable THz-wave image of an enclosed hair with a spatial resolution close to the THz wavelength was obtained.


  • Frequency-agile injection-seeded terahertz-wave parametric generation

    by Yoshikiyo Moriguchi, Yu Tokizane, Yuma Takida, Kouji Nawata, Shigenori Nagano, Manabu Sato, Taiichi Otsuji, Hiroaki Minamide

    An injection-seeded terahertz (THz)-wave parametric generator (is-TPG) enables access to low-frequency fingerprints of molecules in the THz frequency region. However, its conventional scan repetition rate (SRR) is limited below 1 Hz. Thus, in this Letter, we propose an electrically controlled tuning system for the is-TPG, which provides high-speed scanning and random hopping agility. We achieved rapid THz frequency scanning on a pulse-by-pulse basis by employing a gain-switched laser diode and a micro-electromechanical system tunable vertical-cavity surface-emitting laser as the pump and seed lasers. A THz spectrum was acquired with a 10 times higher SRR of 10 Hz for the 1.6–3 THz range with a sampling resolution of 4.6 GHz.


  • Open Access

    High-average and high-peak output-power terahertz-wave generation by optical parametric down-conversion in MgO:LiNbO3

    by Yoshikiyo Moriguchi, Yu Tokizane, Yuma Takida, Kouji Nawata, Taizo Eno, Shigenori Nagano, Hiroaki Minamide

    A widely tunable terahertz (THz)-wave generation that has a high repetition rate and a narrow line width is demonstrated in this paper by injection-seeded THz-wave parametric generation (is-TPG) in a MgO:LiNbO3 crystal. By pumping the crystal using a passively Q-switched neodymium-doped yttrium vanadate microchip laser with a time duration of 140 ps and an average power of up to 5 W, a THz-wave output with an average output power of 30 μW, a peak power of 4 W, a pulse duration of 73 ps, and a pulse-repetition frequency of 100 kHz is obtained. To prevent laser damage and photorefractive damage to the crystal, the constraints on the pumping condition of the MgO:LiNbO3 crystal are experimentally studied by changing the pumping parameters. As a result, we achieved the stable generation of the THz-wave signal in the 100 kHz regime. Moreover, we performed THz-wave imaging by using the developed is-TPG source. The obtained THz image indicated that the developed system has a good stability over long periods of time.


  • 100-kHz-Repetition-Rate Terahertz-Wave Parametric Generator for Imaging Applications

    by Yoshikiyo Moriguchi, Yu Tokizane, Yuma Takida, Kouji Nawata, Shigenori Nagano, Taizo Eno, Masahiro Akiba, Hiroaki Minamide

    We investigated the performance of an injection-seeded THz-wave parametric generator at a repetition frequency in the 100-kHz regime. We obtained a THz-wave output of ~30 μW in the range of 1.0–2.8 THz.


  • High-Repetition-Rate, widely tunable, injection-seeded terahertz-wave parametric generator

    by Yoshikiyo Moriguchi, Kouji Nawata, Yuma Takida, Yu Tokizane, Shigenori Nagano, Taizo Eno, Kaoru Kumagai, Hiroaki Minamide

    We have developed a record high-repetition-rate terahertz-wave parametric generator using MgO:LiNbO 3 . The generator is pumped using a post-amplified, sub-nanosecond, and passively Q-switched SESAM microchip laser running with a 100 kHz repetition frequency. A double-pass dual-end-pumped Nd:YVO 4 amplifier was developed and the microchip laser output was efficiently amplified between 5 mW-4.4 W. This high-repetition-rate amplified pump source allows high-intensity pumping without damage to the nonlinear crystal. Consequently, we have succeeded in generating monochromatic terahertz waves with a repetition-rate a thousand times higher than that of a conventional terahertz-wave parametric generator. The average power and the pulse width of the terahertz waves were ~10 μW and 73 ps, respectively. The tunable frequency was confirmed to be in the range 1.0-2.8 THz.