Yoshikiyo Moriguchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yoshikiyo Moriguchi has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
Hiroaki Minamide
Research Institute of Electrical Communication, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai, Miyagi 980-8577, Japan
4 shared publicationsKouji Nawata
RIKEN Center for Advanced Photonics, RIKEN, 519-1399 Aramaki-aoba, Aoba-ku, Sendai,Miyagi 980-0845, Japan
4 shared publicationsShigenori Nagano
Topcon Corporation, 75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan
4 shared publicationsYu Tokizane
RIKEN Center for Advanced Photonics, RIKEN, 519-1399 Aramaki-aoba, Aoba-ku, Sendai,Miyagi 980-0845, Japan
4 shared publications- Masahiro Akiba
Topcon Corporation, Tokyo, Japan
3 shared publications Masato Tamura
Research & Development Division, Topcon Corporation, Itabashi, Japan
3 shared publications
Latest Publications
- 10 January 2026
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 264 (5) , 1327-1336
Exploratory investigation of OCTA-VISTA for longitudinal monitoring of neovascular age-related macular degeneration treatment
- 10 January 2026
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 264 (5) , 1327-1336
Exploratory investigation of OCTA-VISTA for longitudinal monitoring of neovascular age-related macular degeneration treatment
- Open Access
- 25 November 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (23) , 7140
Optical Attenuation Coefficient-Based En Face Optical Coherence Tomography Imaging for the Reliable Assessment of the Ellipsoid Zone
Objective: This study used optical attenuation coefficient (OAC)-based optical coherence tomography (OCT) en face images to assess the ellipsoid zone (EZ) in the foveal region. Methods: This retrospective, observational, cross-sectional study of 41 healthy volunteers and 34 patients with retinal diseases included imaging data acquired using a prototype swept-source OCT system. EZ en face images were generated from OCT raster scan volumes based on OAC, followed by denoising and binarization to quantify the percentage of EZ structural normality or abnormality relative to the total imaging area. We evaluated the reliability of the OAC-based method compared with the OCT signal intensity-based method in healthy and diseased eyes. In addition, the validated program was applied to patients with various retinal conditions. Results: The estimated normal EZ area in healthy eyes was 96.2 ± 5.6% using the OAC-based method versus 89.3 ± 18.8% for the intensity-based method. The OAC-based method effectively mitigated various artifacts caused by retinal blood vessels and other factors in both healthy and diseased eyes. In a pilot study involving six diseased eyes, the area exhibiting EZ structural abnormalities was 27.5–99.6%. Conclusions: The OAC-based EZ assessment robustly suppressed image artifacts and reliably characterized structural abnormalities in the EZ from OCT volumes.
- 25 November 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (23) , 7140
Open AccessOptical Attenuation Coefficient-Based En Face Optical Coherence Tomography Imaging for the Reliable Assessment of the Ellipsoid Zone
Objective: This study used optical attenuation coefficient (OAC)-based optical coherence tomography (OCT) en face images to assess the ellipsoid zone (EZ) in the foveal region. Methods: This retrospective, observational, cross-sectional study of 41 healthy volunteers and 34 patients with retinal diseases included imaging data acquired using a prototype swept-source OCT system. EZ en face images were generated from OCT raster scan volumes based on OAC, followed by denoising and binarization to quantify the percentage of EZ structural normality or abnormality relative to the total imaging area. We evaluated the reliability of the OAC-based method compared with the OCT signal intensity-based method in healthy and diseased eyes. In addition, the validated program was applied to patients with various retinal conditions. Results: The estimated normal EZ area in healthy eyes was 96.2 ± 5.6% using the OAC-based method versus 89.3 ± 18.8% for the intensity-based method. The OAC-based method effectively mitigated various artifacts caused by retinal blood vessels and other factors in both healthy and diseased eyes. In a pilot study involving six diseased eyes, the area exhibiting EZ structural abnormalities was 27.5–99.6%. Conclusions: The OAC-based EZ assessment robustly suppressed image artifacts and reliably characterized structural abnormalities in the EZ from OCT volumes.
- 14 July 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (8) , 4112-4125
Extended and adjustable field-of-view of variable interscan time analysis by ammonite-scanning swept-source optical coherence tomography angiography
A novel scanning protocol, ammonite scan, is proposed for widefield optical coherence tomography angiography (OCTA) and relative retinal blood flow velocity imaging in the human retina using variable interscan time analysis (VISTA). A repeated circle scan using a 400 kHz swept-source was employed to achieve an interscan time of 1.28 ms. The center of the repeated circular scan continuously moved spirally towards the peripheral region, ensuring an extended and adjustable scan range while preserving the short interscan time. Image artifacts due to eye movement were eliminated via extra motion-correction processing using data redundancy. The relative blood flow velocity in superficial and deep plexus layers was calculated from the VISTA image, and their ratio was used to explore the microvascular flow parameter in the healthy human eye.& COPY; 2023 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement
- 14 July 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (8) , 4112-4125
Extended and adjustable field-of-view of variable interscan time analysis by ammonite-scanning swept-source optical coherence tomography angiography
A novel scanning protocol, ammonite scan, is proposed for widefield optical coherence tomography angiography (OCTA) and relative retinal blood flow velocity imaging in the human retina using variable interscan time analysis (VISTA). A repeated circle scan using a 400 kHz swept-source was employed to achieve an interscan time of 1.28 ms. The center of the repeated circular scan continuously moved spirally towards the peripheral region, ensuring an extended and adjustable scan range while preserving the short interscan time. Image artifacts due to eye movement were eliminated via extra motion-correction processing using data redundancy. The relative blood flow velocity in superficial and deep plexus layers was calculated from the VISTA image, and their ratio was used to explore the microvascular flow parameter in the healthy human eye.& COPY; 2023 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement
- 18 October 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (30) , 9553-9559
Sensorless astigmatism correction using a variable cross-cylinder for high lateral resolution optical coherence tomography in a human retina
High lateral resolution ( ∼ 5 µ m ) optical coherence tomography (OCT) that employs a variable cross-cylinder (VCC) to compensate for astigmatism is presented for visualizing minute structures of the human retina. The VCC and its sensorless optimization process enable ocular astigmatism correction of up to − 5.0 diopter within a few seconds. VCC correction has been proven to increase the signal-to-noise ratio and lateral resolution using a model eye. This process is also validated using the human eye by visualizing the capillary network and human cone mosaic. The proposed method is applicable to existing OCT, making high lateral resolution OCT practical in clinical settings.
- 18 October 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (30) , 9553-9559
Sensorless astigmatism correction using a variable cross-cylinder for high lateral resolution optical coherence tomography in a human retina
High lateral resolution ( ∼ 5 µ m ) optical coherence tomography (OCT) that employs a variable cross-cylinder (VCC) to compensate for astigmatism is presented for visualizing minute structures of the human retina. The VCC and its sensorless optimization process enable ocular astigmatism correction of up to − 5.0 diopter within a few seconds. VCC correction has been proven to increase the signal-to-noise ratio and lateral resolution using a model eye. This process is also validated using the human eye by visualizing the capillary network and human cone mosaic. The proposed method is applicable to existing OCT, making high lateral resolution OCT practical in clinical settings.
- Open Access
- 1 September 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (9) , 093002
Injection-seeded terahertz-wave parametric generator with timing stabilized excitation for nondestructive testing applications
An injection-seeded terahertz (THz)-wave parametric generator (is-TPG) with a footprint the size of an A3 paper is presented. We improved the measurement performance of the is-TPG source for nondestructive inspection applications. A high pulse repetition rate up to 70 kHz and a low pulse timing jitter of a few tens of picoseconds, which is approximately one ten-thousandth of the conventional is-TPG, were achieved. THz waves exhibited excellent performance with a maximum average output power of 20 µW, a monochromatic spectrum linewidth of ∼20 GHz, and a frequency tuning range of 1.7–3.0 THz. This was achieved by designing the entire system configuration from the pump laser source to THz-wave generation. A new double-pass all-solid-state optical amplifier was developed with a high gain and low noise using an externally pulse-modulated laser diode (LD) as the master oscillator source. An achromatic optical injection system was developed for the is-TPG with a 40% reduction in the conventional path length. They were housed in a single enclosure in two layers. LDs and optical fiber amplifiers could be rack-mounted, and the outputs were delivered to the housing via optical fibers. The developed THz-wave source performed nondestructive imaging of a human hair sample fixed with Scotch tape on a test pattern in an envelope by irradiating 2.1 THz waves. A clearly recognizable THz-wave image of an enclosed hair with a spatial resolution close to the THz wavelength was obtained.
- 1 September 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (9) , 093002
Open AccessInjection-seeded terahertz-wave parametric generator with timing stabilized excitation for nondestructive testing applications
An injection-seeded terahertz (THz)-wave parametric generator (is-TPG) with a footprint the size of an A3 paper is presented. We improved the measurement performance of the is-TPG source for nondestructive inspection applications. A high pulse repetition rate up to 70 kHz and a low pulse timing jitter of a few tens of picoseconds, which is approximately one ten-thousandth of the conventional is-TPG, were achieved. THz waves exhibited excellent performance with a maximum average output power of 20 µW, a monochromatic spectrum linewidth of ∼20 GHz, and a frequency tuning range of 1.7–3.0 THz. This was achieved by designing the entire system configuration from the pump laser source to THz-wave generation. A new double-pass all-solid-state optical amplifier was developed with a high gain and low noise using an externally pulse-modulated laser diode (LD) as the master oscillator source. An achromatic optical injection system was developed for the is-TPG with a 40% reduction in the conventional path length. They were housed in a single enclosure in two layers. LDs and optical fiber amplifiers could be rack-mounted, and the outputs were delivered to the housing via optical fibers. The developed THz-wave source performed nondestructive imaging of a human hair sample fixed with Scotch tape on a test pattern in an envelope by irradiating 2.1 THz waves. A clearly recognizable THz-wave image of an enclosed hair with a spatial resolution close to the THz wavelength was obtained.
- 17 December 2019
- Published by Optica Publishing Group in Optics Letters
- Vol. 45 (1) , 77-80
Frequency-agile injection-seeded terahertz-wave parametric generation
An injection-seeded terahertz (THz)-wave parametric generator (is-TPG) enables access to low-frequency fingerprints of molecules in the THz frequency region. However, its conventional scan repetition rate (SRR) is limited below 1 Hz. Thus, in this Letter, we propose an electrically controlled tuning system for the is-TPG, which provides high-speed scanning and random hopping agility. We achieved rapid THz frequency scanning on a pulse-by-pulse basis by employing a gain-switched laser diode and a micro-electromechanical system tunable vertical-cavity surface-emitting laser as the pump and seed lasers. A THz spectrum was acquired with a 10 times higher SRR of 10 Hz for the 1.6–3 THz range with a sampling resolution of 4.6 GHz.
- 17 December 2019
- Published by Optica Publishing Group in Optics Letters
- Vol. 45 (1) , 77-80
Frequency-agile injection-seeded terahertz-wave parametric generation
An injection-seeded terahertz (THz)-wave parametric generator (is-TPG) enables access to low-frequency fingerprints of molecules in the THz frequency region. However, its conventional scan repetition rate (SRR) is limited below 1 Hz. Thus, in this Letter, we propose an electrically controlled tuning system for the is-TPG, which provides high-speed scanning and random hopping agility. We achieved rapid THz frequency scanning on a pulse-by-pulse basis by employing a gain-switched laser diode and a micro-electromechanical system tunable vertical-cavity surface-emitting laser as the pump and seed lasers. A THz spectrum was acquired with a 10 times higher SRR of 10 Hz for the 1.6–3 THz range with a sampling resolution of 4.6 GHz.
- Open Access
- 17 September 2018
- Published by AIP Publishing in Applied Physics Letters
- Vol. 113 (12) , 121103
High-average and high-peak output-power terahertz-wave generation by optical parametric down-conversion in MgO:LiNbO3
A widely tunable terahertz (THz)-wave generation that has a high repetition rate and a narrow line width is demonstrated in this paper by injection-seeded THz-wave parametric generation (is-TPG) in a MgO:LiNbO3 crystal. By pumping the crystal using a passively Q-switched neodymium-doped yttrium vanadate microchip laser with a time duration of 140 ps and an average power of up to 5 W, a THz-wave output with an average output power of 30 μW, a peak power of 4 W, a pulse duration of 73 ps, and a pulse-repetition frequency of 100 kHz is obtained. To prevent laser damage and photorefractive damage to the crystal, the constraints on the pumping condition of the MgO:LiNbO3 crystal are experimentally studied by changing the pumping parameters. As a result, we achieved the stable generation of the THz-wave signal in the 100 kHz regime. Moreover, we performed THz-wave imaging by using the developed is-TPG source. The obtained THz image indicated that the developed system has a good stability over long periods of time.
- 17 September 2018
- Published by AIP Publishing in Applied Physics Letters
- Vol. 113 (12) , 121103
Open AccessHigh-average and high-peak output-power terahertz-wave generation by optical parametric down-conversion in MgO:LiNbO3
A widely tunable terahertz (THz)-wave generation that has a high repetition rate and a narrow line width is demonstrated in this paper by injection-seeded THz-wave parametric generation (is-TPG) in a MgO:LiNbO3 crystal. By pumping the crystal using a passively Q-switched neodymium-doped yttrium vanadate microchip laser with a time duration of 140 ps and an average power of up to 5 W, a THz-wave output with an average output power of 30 μW, a peak power of 4 W, a pulse duration of 73 ps, and a pulse-repetition frequency of 100 kHz is obtained. To prevent laser damage and photorefractive damage to the crystal, the constraints on the pumping condition of the MgO:LiNbO3 crystal are experimentally studied by changing the pumping parameters. As a result, we achieved the stable generation of the THz-wave signal in the 100 kHz regime. Moreover, we performed THz-wave imaging by using the developed is-TPG source. The obtained THz image indicated that the developed system has a good stability over long periods of time.
- 1 January 2018
- Published by Optica Publishing Group
- p. MW3C.4
100-kHz-Repetition-Rate Terahertz-Wave Parametric Generator for Imaging Applications
We investigated the performance of an injection-seeded THz-wave parametric generator at a repetition frequency in the 100-kHz regime. We obtained a THz-wave output of ~30 μW in the range of 1.0–2.8 THz.
- 1 January 2018
- Published by Optica Publishing Group
- p. MW3C.4
100-kHz-Repetition-Rate Terahertz-Wave Parametric Generator for Imaging Applications
We investigated the performance of an injection-seeded THz-wave parametric generator at a repetition frequency in the 100-kHz regime. We obtained a THz-wave output of ~30 μW in the range of 1.0–2.8 THz.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
High-Repetition-Rate, widely tunable, injection-seeded terahertz-wave parametric generator
We have developed a record high-repetition-rate terahertz-wave parametric generator using MgO:LiNbO 3 . The generator is pumped using a post-amplified, sub-nanosecond, and passively Q-switched SESAM microchip laser running with a 100 kHz repetition frequency. A double-pass dual-end-pumped Nd:YVO 4 amplifier was developed and the microchip laser output was efficiently amplified between 5 mW-4.4 W. This high-repetition-rate amplified pump source allows high-intensity pumping without damage to the nonlinear crystal. Consequently, we have succeeded in generating monochromatic terahertz waves with a repetition-rate a thousand times higher than that of a conventional terahertz-wave parametric generator. The average power and the pulse width of the terahertz waves were ~10 μW and 73 ps, respectively. The tunable frequency was confirmed to be in the range 1.0-2.8 THz.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
High-Repetition-Rate, widely tunable, injection-seeded terahertz-wave parametric generator
We have developed a record high-repetition-rate terahertz-wave parametric generator using MgO:LiNbO 3 . The generator is pumped using a post-amplified, sub-nanosecond, and passively Q-switched SESAM microchip laser running with a 100 kHz repetition frequency. A double-pass dual-end-pumped Nd:YVO 4 amplifier was developed and the microchip laser output was efficiently amplified between 5 mW-4.4 W. This high-repetition-rate amplified pump source allows high-intensity pumping without damage to the nonlinear crystal. Consequently, we have succeeded in generating monochromatic terahertz waves with a repetition-rate a thousand times higher than that of a conventional terahertz-wave parametric generator. The average power and the pulse width of the terahertz waves were ~10 μW and 73 ps, respectively. The tunable frequency was confirmed to be in the range 1.0-2.8 THz.
- 1 January 2015
- Published by Japan Society for Laser Surgery and Medicine in THE JOURNAL OF JAPAN SOCIETY FOR LASER SURGERY AND MEDICINE
- Vol. 35 (4) , 409-415
Progress of OCT Diagnostic Instrument in Ophthalmology
- 1 January 2015
- Published by Japan Society for Laser Surgery and Medicine in THE JOURNAL OF JAPAN SOCIETY FOR LASER SURGERY AND MEDICINE
- Vol. 35 (4) , 409-415
Progress of OCT Diagnostic Instrument in Ophthalmology