PSPhitsini Suvarnaphaet

Phitsini Suvarnaphaet

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Phitsini Suvarnaphaet has a total of 33 co-authors. Here are the top co-authors by number of shared publications:

  • Suejit Pechprasarn

    College of Biomedical Engineering, Rangsit University, Pathum Thani 12000, Thailand

    7 shared publications
  • Suejit Pechprasarn

    Rangsit University,College of Biomedical Engineering,Pathum Thani,Thailand

    6 shared publications
  • Chayanisa Sukkasem

    Rangsit University,College of Biomedical Engineering,Pathum Thani,Thailand

    4 shared publications
  • Kodchakorn Ittipornnuson

    Faculty of Biomedical Engineering, Rangsit University, Pathum Thani, Thailand

    3 shared publications
  • Naphat Albutt

    Division of Industrial Materials Science, Faculty of Science and Technology, Rajamangala University of Technology Phra Nakhon, Bangkok, Thailand

    3 shared publications
  • Suvicha Sasivimolkul

    Rangsit University,College of Biomedical Engineering,Pathum Thani,Thailand

    3 shared publications

Latest Publications

  • Open Access

    Fabry–Perot Resonance in 2D Dielectric Grating for Figure of Merit Enhancement in Refractive Index Sensing

    by Suejit Pechprasarn, Suvicha Sasivimolkul, Phitsini Suvarnaphaet

    We have recently reported in our previous work that one-dimensional dielectric grating can provide an open structure for Fabry–Perot mode excitation. The grating gaps allow the sample refractive index to fill up the grating spaces enabling the sample to perturb the Fabry–Perot mode resonant condition. Thus, the grating structure can be utilized as a refractive index sensor and provides convenient sample access from the open end of the grating with an enhanced figure of merit compared to the other thin-film technologies. Here, we demonstrate that 2D grating structures, such as rectangular pillars and circular pillars, can further enhance refractive index sensing performance. The refractive index theory for rectangular pillars and circular pillars are proposed and validated with rigorous coupled wave theory. An effective refractive index theory is proposed to simplify the 2D grating computation and accurately predict the Fabry–Perot mode positions. The 2D gratings have more grating space leading to a higher resonant condition perturbation and sensitivity. They also provide narrower Fabry–Perot mode reflectance dips leading to a 4.5 times figure of merit enhancement than the Fabry–Perot modes excited in the 1D grating. The performance comparison for thin-film technologies for refractive index sensing is also presented and discussed.


  • Open Access

    Analysis of Dielectric Waveguide Grating and Fabry–Perot Modes in Elastic Grating in Optical Detection of Ultrasound

    by Suejit Pechprasarn, Chayanisa Sukkasem, Phitsini Suvarnaphaet

    In our previous work, we have demonstrated that dielectric elastic grating can support Fabry–Perot modes and provide embedded optical interferometry to measure ultrasonic pressure. The Fabry–Perot modes inside the grating provide an enhancement in sensitivity and figure of merit compared to thin film-based Fabry–Perot structures. Here, in this paper, we propose a theoretical framework to explain that the elastic grating also supports dielectric waveguide grating mode, in which optical grating parameters control the excitation of the two modes. The optical properties of the two modes, including coupling conditions and loss mechanisms, are discussed. The proposed grating has the grating period in micron scale, which is shorter than the wavelength of the incident ultrasound leading to an ultrasonic scattering. The gap regions in the grating allow the elastic grating thickness to be compressed by the incident ultrasound and coupled to a surface acoustic wave mode. The thickness compression can be measured using an embedded interferometer through one of the optical guided modes. The dielectric waveguide grating is a narrow bandpass optical filter enabling an ultrasensitive mode to sense changes in optical displacement. This enhancement in mechanical and optical properties gives rise to a broader detectable pressure range and figure of merit in ultrasonic detection; the detectable pressure range and figure of merit can be enhanced by 2.7 times and 23 times, respectively, compared to conventional Fabry–Perot structures.


  • Open Access

    Analysis of Embedded Optical Interferometry in Transparent Elastic Grating for Optical Detection of Ultrasonic Waves

    by Chayanisa Sukkasem, Suvicha Sasivimolkul, Phitsini Suvarnaphaet, Suejit Pechprasarn

    In this paper, we propose a theoretical framework to explain how the transparent elastic grating structure can be employed to enhance the mechanical and optical properties for ultrasonic detection. Incident ultrasonic waves can compress the flexible material, where the change in thickness of the elastic film can be measured through an optical interferometer. Herein, the polydimethylsiloxane (PDMS) was employed in the design of a thin film grating pattern. The PDMS grating with the grating period shorter than the ultrasound wavelength allowed the ultrasound to be coupled into surface acoustic wave (SAW) mode. The grating gaps provided spaces for the PDMS grating to be compressed when the ultrasound illuminated on it. This grating pattern can provide an embedded thin film based optical interferometer through Fabry–Perot resonant modes. Several optical thin film-based technologies for ultrasonic detection were compared. The proposed elastic grating gave rise to higher sensitivity to ultrasonic detection than a surface plasmon resonance-based sensor, a uniform PDMS thin film, a PDMS sensor with shearing interference, and a conventional Fabry–Perot-based sensor. The PDMS grating achieved the enhancement of sensitivity up to 1.3 × 10−5 Pa−1 and figure of merit of 1.4 × 10−5 Pa−1 which were higher than those of conventional Fabry–Perot structure by 7 times and 4 times, respectively.


  • Machine Learning to identify factors that affect Human Systolic Blood Pressure

    by Suejit Pechprasarn, Chayanisa Sukkasem, Suvicha Sasivimolkul, Phitsini Suvarnaphaet

    This paper employs different machine learning algorithms to perform a regression study to predict systolic blood pressure (SBP) levels. We used blood pressure dataset of Dr. Raymond Lam, GlaxoSmithKline, Toronto, Ontario, Canada in this study. There are 500 patients in the dataset, 250 have normal blood pressure level and the other 250 have hypertension. There are 500 predictors in the dataset. 17 predictors are patients’ non-genomic information and the rest are 483 genetic markers. In this paper, we have selected only the following 13 factors as predictors in this study to reduce the complexity of the problem. The predictors included in this study are ’gender’, ’married’, ’smoke’, ’exercise level’, ’age’, ’weight’, ’height’, ’alcohol consumption’, ’treatment for hypertension’, ’stress level’, ’salt intake level’, ’income’ and ’education level’. The regression model that gave the lowest root mean square error in SBP of 25.68 for the 13 predictors is Gaussian Process Regression using the squared exponential function in the regression model. Although the RMS value was quite high, it was sufficient to draw some conclusions and identify the factors that do affect the SBP level.


  • Biodegradable Electrode patch made of Graphene/PHA for ECG detecting Applications

    by Phitsini Suvarnaphaet, Suvicha Sasivimolkul, Chayanisa Sukkasem, Danai Pukesamsombut, Nuttapol Tanadchangsaeng, Sani Boonyagul, Suejit Pechprasarn

    A biomedical electrode patch for detecting an electrocardiogram signal which is provoked by electrical activity through the heart has been investigated. The electrode patch was made of chemical derived graphene as an electrically conductive layer and polyhydroxyalkanoate (PHA) as a flexible substrate. This gra-phene/PHA patch has been promised to be completely biocom-patible and biodegradable by microbes in terrestrial environments. According to the fabrication of the electrode patch, gra-phene was synthesized using Hummers’ method and reduction with hydrazine hydrate. The PHA membrane, an aliphatic polyester bioplastic, was accumulated by Ralstonia eutropha and then was casted using electrospinning technique to serve nanofiber scaffold for an abundance of graphene to be addressed. The gra-phene/PHA electrodes were interfaced to 3-lead electrocardiogram (ECG) sensor and amplifier modules controlling by computing microcontroller. Real-time in vitro monitoring of the simulated ECG signals were observed, including normal condition at 60 BPM and abnormal heart rhythms, through the interfaces of graphene/PHA electrodes. The signals have been shown obviously and no degradation over time, however, the signal attenuation might increase due to in vivo measurement of human skin-electrode impedance.


  • Low-cost instrumentation of Automated Whole – slide Microscope for Biomedical Imaging

    by Suejit Pechprasarn, Chayanisa Sukkasem, Phitsini Suvarnaphaet, Rujirada Thongchoom, Suteeboon Chuwittaya, Metini Janyasupab

    Microscope is one of the essential devices in medical profession. It is usually used for finding out types of abnormal cells or tissues, detecting the diseases, and defining a range treatment option for patient. Recently, there is a new technology of whole-slide imaging (WSI) which has been developed in the microscope. The technology provides the scanning of conventional glass slides to produce digital images of cumulative data. Since the WSI is a complex system and very expensive price, hence we aim to implement the prototype of a cost- effective whole - slide imaging system based on the principle of microscopic design. The implemented prototype consisting of optical and mechanical parts was developed using 3D printing. The optical system employed a 40x objective lens aligning with the digital camera for imaging the specimen on the standard slide. The mechanical system was designed for the movement of the slide in 3 dimensions automatically and controlled by stepper motors and microcontrollers based on controlling computer program. To accumulate the whole- slide image, the slide was scanned and captured in the X-Y axes and the focal (Z) axis in a sequence. The cumulative data was then analyzed and rendered the whole- slide image. The implemented device would be advantageous to cytologists and doctors for the biomedical imaging and recording numerous medical data of the patients.


  • Automated Screening of Cervical Cancer Cell Images

    by Manas Sangworasil, Chayanisa Sukkasem, Suvicha Sasivimolkul, Phitsini Suvarnaphaet, Suejit Pechprasarn, Rujirada Thongchoom, Metini Janyasupab

    Cervical cancer is the first-most common type of female cancer and the second leading cause of death in Thailand. The number of cervical cancer is increasing in every year, even though it is preventable by the screening in early detection. The most popular method for the screening is so-called Pap smear test via examining morphology change in cervix cells. The aim of this research is to implement an image processing algorithm for classifying Pap smear cell images by calculating nucleus-to-cytoplasm area ratio. The algorithm used to classify the nucleus was mathematically calculated through k-mean clustering. The cytoplasm area was calculated from its edge profile relating to geometrical rotation method. Finally, the abnormal cells can be segmented using the area of nucleus-to-cytoplasm ratio with the accuracy of detection at 79%.


  • Open Access

    Quantitative Cross-Platform Performance Comparison between Different Detection Mechanisms in Surface Plasmon Sensors for Voltage Sensing

    by Phitsini Suvarnaphaet, Suejit Pechprasarn

    Surface plasmon Resonance (SPR) has recently been of interest for label-free voltage sensing. Several SPR structures have been proposed. However, making a quantitative cross-platform comparison for these structures is not straightforward due to (1) different SPR measurement mechanisms; (2) different electrolytic solution and concentration in the measurement; and (3) different levels of external applied potential. Here, we propose a quantitative approach to make a direct quantitative comparison across different SPR structures, different electrolytic solutions and different SPR measurement mechanisms. There are two structures employed as example in this theoretical study including uniform plasmonic gold sensor and bimetallic layered structure consisting of uniform silver layer (Ag) coated by uniform gold layer (Ag). The cross-platform comparison was carried by several performance parameters including sensitivity (S), full width half maximum (FWHM) and figure of merit (FoM). We also discuss how the SPR measurement mechanisms enhance the performance parameters and how the bimetallic layer can be employed to enhance the FoM by a factor of 1.34 to 25 depending on the SPR detection mechanism.


  • Open Access

    Enhancement of Long-Range Surface Plasmon Excitation, Dynamic Range and Figure of Merit Using a Dielectric Resonant Cavity

    by Phitsini Suvarnaphaet, Suejit Pechprasarn

    In this paper, we report a theoretical framework on the effect of multiple resonances inside the dielectric cavity of insulator-insulator-metal-insulator (IIMI)-based surface plasmon sensors. It has been very well established that the structure can support both long-range surface plasmon polaritons (LRSPP) and short-range surface plasmon polaritons (SRSPP). We found that the dielectric resonant cavity under certain conditions can be employed as a resonator to enhance the LRSPP properties. These conditions are: (1) the refractive index of the resonant cavity was greater than the refractive index of the sample layer and (2) when light propagated in the resonant cavity and was evanescent in the sample layer. We showed through the analytical calculation using Fresnel equations and rigorous coupled wave theory that the proposed structure with the mentioned conditions can extend the dynamic range of LRSPP excitation and enhance at least five times more plasmon intensity on the surface of the metal compared to the surface plasmon excited by the conventional Kretschmann configuration. It can enhance the dip sensitivity and the dynamic range in refractive index sensing without losing the sharpness of the LRSPP dip. We also showed that the interferometric modes in the cavity can be insensitive to the surface plasmon modes. This allowed a self-referenced surface plasmon resonance structure, in which the interferometric mode measured changes in the sensor structure and the enhanced LRSPP measured changes in the sample channel.


  • Top Cited Papers
    Open Access

    Graphene-Based Materials for Biosensors: A Review

    by Phitsini Suvarnaphaet, Suejit Pechprasarn

    The advantages conferred by the physical, optical and electrochemical properties of graphene-based nanomaterials have contributed to the current variety of ultrasensitive and selective biosensor devices. In this review, we present the points of view on the intrinsic properties of graphene and its surface engineering concerned with the transduction mechanisms in biosensing applications. We explain practical synthesis techniques along with prospective properties of the graphene-based materials, which include the pristine graphene and functionalized graphene (i.e., graphene oxide (GO), reduced graphene oxide (RGO) and graphene quantum dot (GQD). The biosensing mechanisms based on the utilization of the charge interactions with biomolecules and/or nanoparticle interactions and sensing platforms are also discussed, and the importance of surface functionalization in recent up-to-date biosensors for biological and medical applications.