Jingheng Ning
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jingheng Ning has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Jianhui Wang
School of Food Science and Bioengineering, Changsha University of Science and Technology, Changsha, 410114, China; Prepared Dishes Modern Industrial College, Changsha University of Science and Technology, Changsha, 410114, China
6 shared publications - Xin Luo
School of Chemistry and Biological Engineering, Changsha University of Science & Technology, Changsha 410110, China
6 shared publications Chang Sun
School of Chemistry and Chemical Engineering, Changsha University of Science & Technology, Changsha, China
5 shared publicationsRui Wei
School of Chemistry and Chemical Engineering, Changsha University of Science & Technology, Changsha, China
5 shared publications- Donger Chen
School of Chemistry and Biological Engineering, Changsha University of Science & Technology, Changsha 410110, China
4 shared publications - Donglin Liu
School of Chemistry and Biological Engineering, Changsha University of Science & Technology, Changsha 410110, China
4 shared publications
Latest Publications
- 11 February 2025
- Published by Springer Nature in Ionics
- Vol. 31 (4) , 3745-3756
An electrochemical sensor utilizing the biocarbon/tin dioxide composite for sensitive detection of fenitrothion
- 11 February 2025
- Published by Springer Nature in Ionics
- Vol. 31 (4) , 3745-3756
An electrochemical sensor utilizing the biocarbon/tin dioxide composite for sensitive detection of fenitrothion
- 1 January 2024
- Published by Sociedade Brasileira de Quimica (SBQ) in Química Nova
- Vol. 47 (10)
RAPID DEGRADATION OF MALACHITE GREEN DYE WASTEWATER USING H2O2 UNDER RECYCLABLE SILICA/MAGNETIC NANOCATALYST
The discharge of dye contaminant malachite green (MG) into the water environment will seriously affect human health. In this paper, Fe3O4@SiO2 magnetic nanoparticles were prepared as catalysts using co-precipitation and sol-gel methods, which accelerated the removal of MG by H2O2 over a wide pH range with remarkable results. The degradation mechanism is consistent with the Fe2+-H2O2 Fenton system and the pseudo-first-order kinetic model, and the degradation rate can be increased by 179 times compared with not using this catalyst. When pH ≥ 5, Fe3O4@SiO2 catalyzes H2O2 oxidation of MG for only 10 min to achieve a high degradation rate of 99%, and less than 3 min to achieve a 95% degradation rate. The catalyst can be quickly separated and easily regenerated under an external magnetic field, and a degradation rate of 82% can still be reached after 5 uses. In a word, this work has successfully developed an efficient, green and economic MG wastewater treatment technology.
- 1 January 2024
- Published by Sociedade Brasileira de Quimica (SBQ) in Química Nova
- Vol. 47 (10)
RAPID DEGRADATION OF MALACHITE GREEN DYE WASTEWATER USING H2O2 UNDER RECYCLABLE SILICA/MAGNETIC NANOCATALYST
The discharge of dye contaminant malachite green (MG) into the water environment will seriously affect human health. In this paper, Fe3O4@SiO2 magnetic nanoparticles were prepared as catalysts using co-precipitation and sol-gel methods, which accelerated the removal of MG by H2O2 over a wide pH range with remarkable results. The degradation mechanism is consistent with the Fe2+-H2O2 Fenton system and the pseudo-first-order kinetic model, and the degradation rate can be increased by 179 times compared with not using this catalyst. When pH ≥ 5, Fe3O4@SiO2 catalyzes H2O2 oxidation of MG for only 10 min to achieve a high degradation rate of 99%, and less than 3 min to achieve a 95% degradation rate. The catalyst can be quickly separated and easily regenerated under an external magnetic field, and a degradation rate of 82% can still be reached after 5 uses. In a word, this work has successfully developed an efficient, green and economic MG wastewater treatment technology.
- 18 December 2023
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 104 (20) , 9492-9508
(111) Facet-enhancing performance of pure octahedral Cu 2 O nanocrystal for the electrochemical detection of malachite green
- 18 December 2023
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 104 (20) , 9492-9508
(111) Facet-enhancing performance of pure octahedral Cu 2 O nanocrystal for the electrochemical detection of malachite green
- 1 December 2021
- Published by Springer Nature in Journal of Central South University
- Vol. 28 (12) , 3666-3680
Efficient adsorption removal and adsorption mechanism of basic fuchsin by recyclable Fe3O4@CD magnetic microspheres
- 1 December 2021
- Published by Springer Nature in Journal of Central South University
- Vol. 28 (12) , 3666-3680
Efficient adsorption removal and adsorption mechanism of basic fuchsin by recyclable Fe3O4@CD magnetic microspheres
- 12 October 2021
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 13 (46) , 5617-5627
A high performance Pb( ii ) electrochemical sensor based on spherical CuS nanoparticle anchored g-C 3 N 4
Highly efficient electrochemical detection of Pb 2+ is achieved by the composite CuS/g-C 3 N 4 , based on a synergistic effect of “coordination/adsorption” on Pb 2+ provided by both g-C 3 N 4 and CuS. The limit of detection is as low as 4 nM.
- 12 October 2021
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 13 (46) , 5617-5627
A high performance Pb( ii ) electrochemical sensor based on spherical CuS nanoparticle anchored g-C 3 N 4
Highly efficient electrochemical detection of Pb 2+ is achieved by the composite CuS/g-C 3 N 4 , based on a synergistic effect of “coordination/adsorption” on Pb 2+ provided by both g-C 3 N 4 and CuS. The limit of detection is as low as 4 nM.
- 10 July 2020
- Published by Wiley in Electroanalysis
- Vol. 32 (10) , 2273-2281
Highly Hydrophilic Polymer Composite Modified Electrode for Trace Copper Detection Based on Synergetic Electrostatic Attractions and Chelating Interactions
A new electrochemical sensor for Cu2+ detection by square wave voltammetry with high sensitivity has been constructed, based on a composite of sodium carboxymethyl cellulose and Nafion. Starting from these two polymers that are rich of hydrophilic groups in backbones, a highly negative‐charged composite has been easily prepared, which displays outstanding ability to adsorb and enrich Cu2+ onto the electrode surface through both electrostatic attractions and chelating interactions. After optimizing test conditions, this new sensor exhibits a good linear signal response to Cu2+ in a concentration range from 1.0 nΜ to 50.0 nM with a limit of detection of 0.6 nM (S/N=3), as well as good anti‐interference for commonly co‐existing metal ions. Besides, this new electrochemical copper sensor has been successfully applied to detect trace Cu2+ in natural water samples with satisfactory recoveries of 98–104 %. These findings provide a new simple but effective way for the determination of heavy metal ions in environmental pollutants.
- 10 July 2020
- Published by Wiley in Electroanalysis
- Vol. 32 (10) , 2273-2281
Highly Hydrophilic Polymer Composite Modified Electrode for Trace Copper Detection Based on Synergetic Electrostatic Attractions and Chelating Interactions
A new electrochemical sensor for Cu2+ detection by square wave voltammetry with high sensitivity has been constructed, based on a composite of sodium carboxymethyl cellulose and Nafion. Starting from these two polymers that are rich of hydrophilic groups in backbones, a highly negative‐charged composite has been easily prepared, which displays outstanding ability to adsorb and enrich Cu2+ onto the electrode surface through both electrostatic attractions and chelating interactions. After optimizing test conditions, this new sensor exhibits a good linear signal response to Cu2+ in a concentration range from 1.0 nΜ to 50.0 nM with a limit of detection of 0.6 nM (S/N=3), as well as good anti‐interference for commonly co‐existing metal ions. Besides, this new electrochemical copper sensor has been successfully applied to detect trace Cu2+ in natural water samples with satisfactory recoveries of 98–104 %. These findings provide a new simple but effective way for the determination of heavy metal ions in environmental pollutants.
- Open Access
Synergetic Sensing Effect of Sodium Carboxymethyl Cellulose and Bismuth on Cadmium Detection by Differential Pulse Anodic Stripping Voltammetry
In the present work, a novel electrochemical sensor was developed for the detection of trace cadmium with high sensitivity and selectivity in an easy and eco-friendly way. Firstly, a glassy carbon electrode (GCE) was modified with nontoxic sodium carboxymethyl cellulose (CMC) by a simple drop-casting method, which was applied to detect cadmium by differential pulse anodic stripping voltammetry (DPASV) in a solution containing both target cadmium and eco-friendly bismuth ions, based on a quick electro-codeposition of these two metal ions on the surface of the modified electrode (CMC-GCE). Investigated by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and Fourier transform infrared spectroscopy (FT-IR), both CMC (with good film-forming ability) and bismuth (with well-defined stripping signal) were found to be well complexed with target cadmium, leading to vital signal amplification for cadmium detection at a sub-nanomolar level. Under the optimal conditions, the proposed sensor exhibited a good linear stripping signal response to cadmium (Ⅱ) ion, in a concentration range of 0.001 μmol/L–1 μmol/L with a limit of detection of 0.75 nmol/L (S/N = 3). Meanwhile, the results demonstrate that this novel electrochemical sensor has excellent sensitivity and reproducibility, which can be used as a promising detection technique for testing natural samples such as tap water.
Open AccessSynergetic Sensing Effect of Sodium Carboxymethyl Cellulose and Bismuth on Cadmium Detection by Differential Pulse Anodic Stripping Voltammetry
In the present work, a novel electrochemical sensor was developed for the detection of trace cadmium with high sensitivity and selectivity in an easy and eco-friendly way. Firstly, a glassy carbon electrode (GCE) was modified with nontoxic sodium carboxymethyl cellulose (CMC) by a simple drop-casting method, which was applied to detect cadmium by differential pulse anodic stripping voltammetry (DPASV) in a solution containing both target cadmium and eco-friendly bismuth ions, based on a quick electro-codeposition of these two metal ions on the surface of the modified electrode (CMC-GCE). Investigated by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and Fourier transform infrared spectroscopy (FT-IR), both CMC (with good film-forming ability) and bismuth (with well-defined stripping signal) were found to be well complexed with target cadmium, leading to vital signal amplification for cadmium detection at a sub-nanomolar level. Under the optimal conditions, the proposed sensor exhibited a good linear stripping signal response to cadmium (Ⅱ) ion, in a concentration range of 0.001 μmol/L–1 μmol/L with a limit of detection of 0.75 nmol/L (S/N = 3). Meanwhile, the results demonstrate that this novel electrochemical sensor has excellent sensitivity and reproducibility, which can be used as a promising detection technique for testing natural samples such as tap water.
- Open Access
Abnormal Anionic Porphyrin Sensing Effect for HER2 Gene Related DNA Detection via Impedance Difference between MWCNTs and Single-Stranded DNA or Double-Stranded DNA
Human epidermal growth factor receptor 2 (HER2) is a key tumor marker for several common and deadly cancers. It is of great importance to develop efficient detection methods for its over-expression. In this work, an electrochemical impedance spectroscopy (EIS) method adjustable by anionic porphyrin for HER2 gene detection has been proposed, based on the impedance difference between multi-walled carbon nanotubes (MWCNTs) and DNA. The interesting finding herein is that with the addition of anionic porphyrin, i.e., meso-tetra(4-sulfophenyl)-porphyrin (TSPP), the impedance value obtained at a glass carbon electrode (GCE) modified with MWCNTs and a single stranded DNA (ssDNA), the probe DNA that might be assembled tightly onto MWCNTs through π-π stacking interaction, gets a slight decrease; however, the impedance value from a GCE modified with MWCNTs and a double stranded DNA (dsDNA), the hybrid of the probe DNA with a target DNA, which might be assembled loosely onto MWCNTs for the screening effect of phosphate backbones in dsDNA, gets an obvious decrease. The reason may be that on the one hand, being rich in negative sulfonate groups, TSPP will try to push DNA far away from CNTs surface due to its strong electrostatic repulsion towards DNA; on the other hand, rich in planar phenyl or pyrrole rings, TSPP will compete with DNA for the surface of CNTs since it can also be assembled onto CNTs through conjugative interactions. In this way, the “loosely assembled” dsDNA will be repelled by this anionic porphyrin and released off CNTs surface much more than the “tightly assembled” ssDNA, leading to a bigger difference in the impedance value between dsDNA and ssDNA. Thus, through the amplification effect of TSPP on the impedance difference, the perfectly matched target DNA could be easily determined by EIS without any label. Under the optimized experimental conditions, this electrochemical sensor shows an excellent linear response to target DNA in a concentration range of 2.0 × 10−11–2.0 × 10−6 M with a limit of detection (LOD) of 6.34 × 10−11 M (S/N = 3). This abnormally sensitive electrochemical sensing performance resulting from anionic porphyrin for DNA sequences specific to HER2 gene will offer considerable promise for tumor diagnosis and treatment.
Open AccessAbnormal Anionic Porphyrin Sensing Effect for HER2 Gene Related DNA Detection via Impedance Difference between MWCNTs and Single-Stranded DNA or Double-Stranded DNA
Human epidermal growth factor receptor 2 (HER2) is a key tumor marker for several common and deadly cancers. It is of great importance to develop efficient detection methods for its over-expression. In this work, an electrochemical impedance spectroscopy (EIS) method adjustable by anionic porphyrin for HER2 gene detection has been proposed, based on the impedance difference between multi-walled carbon nanotubes (MWCNTs) and DNA. The interesting finding herein is that with the addition of anionic porphyrin, i.e., meso-tetra(4-sulfophenyl)-porphyrin (TSPP), the impedance value obtained at a glass carbon electrode (GCE) modified with MWCNTs and a single stranded DNA (ssDNA), the probe DNA that might be assembled tightly onto MWCNTs through π-π stacking interaction, gets a slight decrease; however, the impedance value from a GCE modified with MWCNTs and a double stranded DNA (dsDNA), the hybrid of the probe DNA with a target DNA, which might be assembled loosely onto MWCNTs for the screening effect of phosphate backbones in dsDNA, gets an obvious decrease. The reason may be that on the one hand, being rich in negative sulfonate groups, TSPP will try to push DNA far away from CNTs surface due to its strong electrostatic repulsion towards DNA; on the other hand, rich in planar phenyl or pyrrole rings, TSPP will compete with DNA for the surface of CNTs since it can also be assembled onto CNTs through conjugative interactions. In this way, the “loosely assembled” dsDNA will be repelled by this anionic porphyrin and released off CNTs surface much more than the “tightly assembled” ssDNA, leading to a bigger difference in the impedance value between dsDNA and ssDNA. Thus, through the amplification effect of TSPP on the impedance difference, the perfectly matched target DNA could be easily determined by EIS without any label. Under the optimized experimental conditions, this electrochemical sensor shows an excellent linear response to target DNA in a concentration range of 2.0 × 10−11–2.0 × 10−6 M with a limit of detection (LOD) of 6.34 × 10−11 M (S/N = 3). This abnormally sensitive electrochemical sensing performance resulting from anionic porphyrin for DNA sequences specific to HER2 gene will offer considerable promise for tumor diagnosis and treatment.
- Open Access
Ultrasensitive Electrochemical Sensor Based on Polyelectrolyte Composite Film Decorated Glassy Carbon Electrode for Detection of Nitrite in Curing Food at Sub-Micromolar Level
To ensure food quality and safety, developing cost-effective, rapid and precision analytical techniques for quantitative detection of nitrite is highly desirable. Herein, a novel electrochemical sensor based on the sodium cellulose sulfate/poly (dimethyl diallyl ammonium chloride) (NaCS/PDMDAAC) composite film modified glass carbon electrode (NaCS/PDMDAAC/GCE) was proposed toward the detection of nitrite at sub-micromolar level, aiming to make full use of the inherent properties of individual component (biocompatible, low cost, good electrical conductivity for PDMDAAC; non-toxic, abundant raw materials, good film forming ability for NaCS) and synergistic enhancement effect. The NaCS/PDMDAAC/GCE was fabricated by a simple drop-casting method. Electrochemical behaviors of nitrite at NaCS/PDMDAAC/GCE were investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Under optimum conditions, the NaCS/PDMDAAC/GCE exhibits a wide linear response region of 4.0 × 10−8 mol·L−1~1.5 × 10−4 mol·L−1 and a low detection 1imit of 43 nmol·L−1. The NaCS/PDMDAAC shows a synergetic enhancement effect toward the oxidation of nitrite, and the sensing performance is much better than the previous reports. Moreover, the NaCS/PDMDAAC also shows good stability and reproducibility. The NaCS/PDMDAAC/GCE was successfully applied to the determination of nitrite in ham sausage with satisfactory results.
Open AccessUltrasensitive Electrochemical Sensor Based on Polyelectrolyte Composite Film Decorated Glassy Carbon Electrode for Detection of Nitrite in Curing Food at Sub-Micromolar Level
To ensure food quality and safety, developing cost-effective, rapid and precision analytical techniques for quantitative detection of nitrite is highly desirable. Herein, a novel electrochemical sensor based on the sodium cellulose sulfate/poly (dimethyl diallyl ammonium chloride) (NaCS/PDMDAAC) composite film modified glass carbon electrode (NaCS/PDMDAAC/GCE) was proposed toward the detection of nitrite at sub-micromolar level, aiming to make full use of the inherent properties of individual component (biocompatible, low cost, good electrical conductivity for PDMDAAC; non-toxic, abundant raw materials, good film forming ability for NaCS) and synergistic enhancement effect. The NaCS/PDMDAAC/GCE was fabricated by a simple drop-casting method. Electrochemical behaviors of nitrite at NaCS/PDMDAAC/GCE were investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Under optimum conditions, the NaCS/PDMDAAC/GCE exhibits a wide linear response region of 4.0 × 10−8 mol·L−1~1.5 × 10−4 mol·L−1 and a low detection 1imit of 43 nmol·L−1. The NaCS/PDMDAAC shows a synergetic enhancement effect toward the oxidation of nitrite, and the sensing performance is much better than the previous reports. Moreover, the NaCS/PDMDAAC also shows good stability and reproducibility. The NaCS/PDMDAAC/GCE was successfully applied to the determination of nitrite in ham sausage with satisfactory results.
- Open Access
SiO2 Stabilized Magnetic Nanoparticles as a Highly Effective Catalyst for the Degradation of Basic Fuchsin in Industrial Dye Wastewaters
Catalytic degradation of organic pollutants by nanomaterials is an effective way for environmental remediation. The Fenton reaction involving H2O2 oxidation catalysed by Fe3+ is an advisable way for wastewater degradation. Herein, Fe3O4/SiO2 core-shell nanoparticles were prepared as catalyst by coprecipitation and sol-gel methods, and this catalyst is used for degradation of fuchsin in wastewater by H2O2. The Fenton reaction between H2O2 and Fe3O4 is proposed to explain the catalytic performance. The coating of SiO2 on Fe3O4 nanoparticles could dramatically stabilize the Fe3O4 in aqueous solution and prevent their oxidation. More importantly, the magnetic property of Fe3O4 nanoparticles endows them with good recyclability. Thus, due to the outstanding catalytic results, almost 100% removal degradation was achieved within 5 min over a wide pH value range at room temperature, which is better than that without catalysts. Temperature is a positive factor for improving the degradation rate, but room temperature is selected as the best temperature for economic and energy savings reasons, because more than 98% of fuchsins can still be degraded at room temperature. Moreover, these Fe3O4/SiO2 core-shell nanoparticles exhibit excellent magnetic recyclability and stable properties after repeated utilization. Therefore, these as-presented Fe3O4/SiO2 core-shell nanoparticles with low-cost and high performance are expected to be applied in practical industry wastewater degradation.
Open AccessSiO2 Stabilized Magnetic Nanoparticles as a Highly Effective Catalyst for the Degradation of Basic Fuchsin in Industrial Dye Wastewaters
Catalytic degradation of organic pollutants by nanomaterials is an effective way for environmental remediation. The Fenton reaction involving H2O2 oxidation catalysed by Fe3+ is an advisable way for wastewater degradation. Herein, Fe3O4/SiO2 core-shell nanoparticles were prepared as catalyst by coprecipitation and sol-gel methods, and this catalyst is used for degradation of fuchsin in wastewater by H2O2. The Fenton reaction between H2O2 and Fe3O4 is proposed to explain the catalytic performance. The coating of SiO2 on Fe3O4 nanoparticles could dramatically stabilize the Fe3O4 in aqueous solution and prevent their oxidation. More importantly, the magnetic property of Fe3O4 nanoparticles endows them with good recyclability. Thus, due to the outstanding catalytic results, almost 100% removal degradation was achieved within 5 min over a wide pH value range at room temperature, which is better than that without catalysts. Temperature is a positive factor for improving the degradation rate, but room temperature is selected as the best temperature for economic and energy savings reasons, because more than 98% of fuchsins can still be degraded at room temperature. Moreover, these Fe3O4/SiO2 core-shell nanoparticles exhibit excellent magnetic recyclability and stable properties after repeated utilization. Therefore, these as-presented Fe3O4/SiO2 core-shell nanoparticles with low-cost and high performance are expected to be applied in practical industry wastewater degradation.