    Verification of a Rapidly Multiplexed Circuit for Scalable Action Potential Recording

    by Mohit Sharma, Hunter Joseph Strathman, Ross Martin Walker

    This report presents characterizations of in vivo neural recordings performed with a CMOS multichannel neural recording chip that uses rapid multiplexing directly at the electrodes, without any pre-amplification or buffering. Neural recordings were taken from a 16-channel microwire array implanted in rodent cortex, with comparison to a gold-standard commercial bench-top recording system. We were able to record well-isolated threshold crossings from 10 multiplexed electrodes and typical local field potential waveforms from 16, with strong agreement with the standard system (average SNR = 2.59 and 3.07 respectively). For 10 electrodes, the circuit achieves an effective area per channel of 0.0077 mm 2 , which is >5× smaller than typical multichannel chips. Extensive characterizations of noise and signal quality are presented and compared to fundamental theory, as well as results from in vivo and in vitro experiments. By demonstrating the validation of rapid multiplexing directly at the electrodes, this report confirms it as a promising approach for reducing circuit area in massively-multichannel neural recording systems, which is crucial for scaling recording site density and achieving large-scale sensing of brain activity with high spatiotemporal resolution.


  • Open Access

    Acquisition of Neural Action Potentials Using Rapid Multiplexing Directly at the Electrodes

    by Mohit Sharma, Avery Tye Gardner, Hunter J. Strathman, David J. Warren, Jason Silver, Ross M. Walker

    Neural recording systems that interface with implanted microelectrodes are used extensively in experimental neuroscience and neural engineering research. Interface electronics that are needed to amplify, filter, and digitize signals from multichannel electrode arrays are a critical bottleneck to scaling such systems. This paper presents the design and testing of an electronic architecture for intracortical neural recording that drastically reduces the size per channel by rapidly multiplexing many electrodes to a single circuit. The architecture utilizes mixed-signal feedback to cancel electrode offsets, windowed integration sampling to reduce aliased high-frequency noise, and a successive approximation analog-to-digital converter with small capacitance and asynchronous control. Results are presented from a 180 nm CMOS integrated circuit prototype verified using in vivo experiments with a tungsten microwire array implanted in rodent cortex. The integrated circuit prototype achieves 2 area per channel, 7 µW power dissipation per channel, 5.6 µVrms input referred noise, 50 dB common mode rejection ratio, and generates 9-bit samples at 30 kHz per channel by multiplexing at 600 kHz. General considerations are discussed for rapid time domain multiplexing of high-impedance microelectrodes. Overall, this work describes a promising path forward for scaling neural recording systems to numbers of electrodes that are orders of magnitude larger.


  • Impedance and Noise Characterizations of Utah and Microwire Electrode Arrays

    by Avery Tye Gardner, Hunter J. Strathman, David J. Warren, Ross M. Walker

    This work presents an in-depth noise and impedance characterization of two of the most widely used microelectrode arrays (the Utah Electrode Array and the TDT Microwire Array) and provides quantitative analysis of how properties change when implanted in rodent cortex. Custom low-noise circuits and de-embedding methods were designed to acquire $\mathrm{nV} /\sqrt {\mathrm{Hz}}$ noise power spectral densities from high impedance electrodes. A total of 80 electrodes were implanted across five rats and measured under deep anesthesia, demonstrating a 1.5x to 3x increase in noise and 2.25x to 9x in impedance compared to in vitro measurements. Low frequency biological noise was also observed and studied through post mortem measurements. These results are informative for designing neural interfacing systems for both neuroscience and medical applications.