Ross Martin Walker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ross Martin Walker has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- David J. Warren
Department of Biomedical Engineering, The University of Utah, Salt Lake City, UT, USA
2 shared publications - Hunter Joseph Strathman
Department of Biomedical Engineering, University of Utah, Salt Lake City, USA
2 shared publications - Avery Tye Gardner
Electrical & Computer Engineering, University of Utah, Salt Lake CIty, Utah United States 84112
1 shared publication - Avery Tye Gardner
Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT 84112, USA
1 shared publication Hunter J. Strathman
1 shared publication- Jason Silver
Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT 84112, USA
1 shared publication
Latest Publications
- Open Access
- 9 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 13 (6) , 1655-1663
Verification of a Rapidly Multiplexed Circuit for Scalable Action Potential Recording
This report presents characterizations of in vivo neural recordings performed with a CMOS multichannel neural recording chip that uses rapid multiplexing directly at the electrodes, without any pre-amplification or buffering. Neural recordings were taken from a 16-channel microwire array implanted in rodent cortex, with comparison to a gold-standard commercial bench-top recording system. We were able to record well-isolated threshold crossings from 10 multiplexed electrodes and typical local field potential waveforms from 16, with strong agreement with the standard system (average SNR = 2.59 and 3.07 respectively). For 10 electrodes, the circuit achieves an effective area per channel of 0.0077 mm 2 , which is >5× smaller than typical multichannel chips. Extensive characterizations of noise and signal quality are presented and compared to fundamental theory, as well as results from in vivo and in vitro experiments. By demonstrating the validation of rapid multiplexing directly at the electrodes, this report confirms it as a promising approach for reducing circuit area in massively-multichannel neural recording systems, which is crucial for scaling recording site density and achieving large-scale sensing of brain activity with high spatiotemporal resolution.
- 9 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 13 (6) , 1655-1663
Open AccessVerification of a Rapidly Multiplexed Circuit for Scalable Action Potential Recording
This report presents characterizations of in vivo neural recordings performed with a CMOS multichannel neural recording chip that uses rapid multiplexing directly at the electrodes, without any pre-amplification or buffering. Neural recordings were taken from a 16-channel microwire array implanted in rodent cortex, with comparison to a gold-standard commercial bench-top recording system. We were able to record well-isolated threshold crossings from 10 multiplexed electrodes and typical local field potential waveforms from 16, with strong agreement with the standard system (average SNR = 2.59 and 3.07 respectively). For 10 electrodes, the circuit achieves an effective area per channel of 0.0077 mm 2 , which is >5× smaller than typical multichannel chips. Extensive characterizations of noise and signal quality are presented and compared to fundamental theory, as well as results from in vivo and in vitro experiments. By demonstrating the validation of rapid multiplexing directly at the electrodes, this report confirms it as a promising approach for reducing circuit area in massively-multichannel neural recording systems, which is crucial for scaling recording site density and achieving large-scale sensing of brain activity with high spatiotemporal resolution.
- Open Access
- 20 September 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (10) , 477
Acquisition of Neural Action Potentials Using Rapid Multiplexing Directly at the Electrodes
Neural recording systems that interface with implanted microelectrodes are used extensively in experimental neuroscience and neural engineering research. Interface electronics that are needed to amplify, filter, and digitize signals from multichannel electrode arrays are a critical bottleneck to scaling such systems. This paper presents the design and testing of an electronic architecture for intracortical neural recording that drastically reduces the size per channel by rapidly multiplexing many electrodes to a single circuit. The architecture utilizes mixed-signal feedback to cancel electrode offsets, windowed integration sampling to reduce aliased high-frequency noise, and a successive approximation analog-to-digital converter with small capacitance and asynchronous control. Results are presented from a 180 nm CMOS integrated circuit prototype verified using in vivo experiments with a tungsten microwire array implanted in rodent cortex. The integrated circuit prototype achieves 2 area per channel, 7 µW power dissipation per channel, 5.6 µVrms input referred noise, 50 dB common mode rejection ratio, and generates 9-bit samples at 30 kHz per channel by multiplexing at 600 kHz. General considerations are discussed for rapid time domain multiplexing of high-impedance microelectrodes. Overall, this work describes a promising path forward for scaling neural recording systems to numbers of electrodes that are orders of magnitude larger.
- 20 September 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (10) , 477
Open AccessAcquisition of Neural Action Potentials Using Rapid Multiplexing Directly at the Electrodes
Neural recording systems that interface with implanted microelectrodes are used extensively in experimental neuroscience and neural engineering research. Interface electronics that are needed to amplify, filter, and digitize signals from multichannel electrode arrays are a critical bottleneck to scaling such systems. This paper presents the design and testing of an electronic architecture for intracortical neural recording that drastically reduces the size per channel by rapidly multiplexing many electrodes to a single circuit. The architecture utilizes mixed-signal feedback to cancel electrode offsets, windowed integration sampling to reduce aliased high-frequency noise, and a successive approximation analog-to-digital converter with small capacitance and asynchronous control. Results are presented from a 180 nm CMOS integrated circuit prototype verified using in vivo experiments with a tungsten microwire array implanted in rodent cortex. The integrated circuit prototype achieves 2 area per channel, 7 µW power dissipation per channel, 5.6 µVrms input referred noise, 50 dB common mode rejection ratio, and generates 9-bit samples at 30 kHz per channel by multiplexing at 600 kHz. General considerations are discussed for rapid time domain multiplexing of high-impedance microelectrodes. Overall, this work describes a promising path forward for scaling neural recording systems to numbers of electrodes that are orders of magnitude larger.
- 2 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 2 (4) , 234-241
Impedance and Noise Characterizations of Utah and Microwire Electrode Arrays
This work presents an in-depth noise and impedance characterization of two of the most widely used microelectrode arrays (the Utah Electrode Array and the TDT Microwire Array) and provides quantitative analysis of how properties change when implanted in rodent cortex. Custom low-noise circuits and de-embedding methods were designed to acquire $\mathrm{nV} /\sqrt {\mathrm{Hz}}$ noise power spectral densities from high impedance electrodes. A total of 80 electrodes were implanted across five rats and measured under deep anesthesia, demonstrating a 1.5x to 3x increase in noise and 2.25x to 9x in impedance compared to in vitro measurements. Low frequency biological noise was also observed and studied through post mortem measurements. These results are informative for designing neural interfacing systems for both neuroscience and medical applications.- 2 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 2 (4) , 234-241
Impedance and Noise Characterizations of Utah and Microwire Electrode Arrays
This work presents an in-depth noise and impedance characterization of two of the most widely used microelectrode arrays (the Utah Electrode Array and the TDT Microwire Array) and provides quantitative analysis of how properties change when implanted in rodent cortex. Custom low-noise circuits and de-embedding methods were designed to acquire $\mathrm{nV} /\sqrt {\mathrm{Hz}}$ noise power spectral densities from high impedance electrodes. A total of 80 electrodes were implanted across five rats and measured under deep anesthesia, demonstrating a 1.5x to 3x increase in noise and 2.25x to 9x in impedance compared to in vitro measurements. Low frequency biological noise was also observed and studied through post mortem measurements. These results are informative for designing neural interfacing systems for both neuroscience and medical applications.