DGDominik Geier

Dominik Geier

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Dominik Geier has a total of 65 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Non-invasive cleaning monitoring in pipeline systems using ultrasound: an experimental study

    by Yogesh Sharma, Michael Metzenmacher, Sanghyun Cha, Dominik Ulrich Geier, Thomas Becker

  • Open Access

    A physics-guided neural framework for rheology measurement from dynamical laser speckles

    by Tianliang Wang, Thomas Goudoulas, Ehsan Fattahi, Dominik Geier, Yiyuan Yang, Ivan Ezhov, Yixiao Liu, Yi Li, Martin J Booth, Thomas Becker

  • Open Access

    Crude protein prediction in grain-based powder systems using VIS–NIR hyperspectral imaging and feedforward neural networks

    by Ronny Takacs, Günther Gaßner, Dominik Geier, Thomas Becker

    Crude protein content is a key quality parameter in cereal processing, yet conventional reference methods such as Dumas combustion are destructive and require sample preparation. Hyperspectral imaging (HSI) extends conventional point spectroscopy by coupling broadband spectral acquisition with camera-based imaging. This study presents the design, assembly, and characterization of a custom-built two-dimensional VIS/NIR HSI system continuously covering 400–1600 nm within a single measurement configuration. The system integrates illumination-side wavelength selection using a Czerny–Turner monochromator, synchronized VIS and NIR area-scan cameras, a xenon arc lamp, and control electronics. The broadband range was deliberately selected to capture scattering and autofluorescence-related contributions in the visible range alongside chemically specific overtone absorption bands in the near-infrared, providing complementary information. As a proof of concept, a feedforward neural network (FFNN; N–25–1) was trained and evaluated under grouped nested cross-validation (outer 5 × 5; inner threefold) on 27 subsample groups derived from six starch–gluten powder mixtures (reference: Dumas combustion). The model achieved an R 2 of 0.86 ± 0.15 and an RMSE of 0.97 ± 0.54% (w/w) for crude protein estimation across the outer test folds. These results demonstrate the feasibility of non-destructive VIS–NIR hyperspectral imaging for crude protein determination in cereal powder matrices. Future work will extend validation to real wheat flour samples, incorporate additional quality parameters, and investigate systematic wavelength selection to enable compact, cost-effective multispectral sensor concepts.

  • Open Access

    Noninvasive monitoring and prediction of cell count of Saccharomyces suspensions using ultrasonic measurements and artificial neural networks

    by Dominik Geier, Michael Metzenmacher, Iain Whitehead, Thomas Becker

    The dynamic nature of biological suspensions during fermentation requires continuous monitoring. In Saccharomyces suspensions, cell count directly influences biomass production and is an indicator of metabolic efficiency. However, established methods to monitor cell count require sampling, are invasive, or are restricted by detection limits. In contrast, ultrasound techniques are noninvasive and provide real-time feedback. In this study, ultrasound was used to analyze yeast suspensions with increasing concentrations (0.0–1.0 wt%) from three Saccharomyces strains, each assessed at three wort concentrations (10, 12, and 14 wt% extract). The collected analytical data, consisting of manually determined cell count and nine ultrasound-derived features, were used to develop separate artificial neural network (ANN) models for cell count prediction. Three strain-specific regression models were initially developed; their evaluation metrics confirmed that the selected ANN architecture reliably predicted cell count for each strain ( R 2 = 0.96–0.98). Subsequently, regression models able to predict cell count across all strains were developed. The performance of these regression models progressively improved with the integration of non-ultrasound data into the input layer ( R 2 = 0.92–0.97). Additionally, a separate classification model was developed to distinguish between yeast strains, using solely the nine ultrasound-derived features. This classification model achieved an overall accuracy of 96.6%, demonstrating high generalization performance across different biological and process conditions. These findings confirmed that ultrasound-derived features could be effectively modeled using artificial neural networks for cell count prediction and characterization of Saccharomyces suspensions. Graphical Abstract


  • Open Access

    Optimized Laser Speckle Rheology Measurement Based on Speckle Pattern’s Gamma Correction and Neural Network

    by Tianliang Wang, Thomas Goudoulas, Arash Moeini, Dominik Geier, Ehsan Fattahi, Thomas Becker


  • Die Herausforderung der Implementierung von digitalen Zwillingen in operativen Wertschöpfungsketten

    by Roman Werner, Ronny Takacs, Dominik Geier, Thomas Becker, Norbert Weißenberg, Hendrik Haße, Rudolf Sollacher, Michael Thalhofer, Bernhard Schumm, Ines Steinke

  • Open Access

    Non-Invasive Characterization of Different Saccharomyces Suspensions with Ultrasound

    by Dominik Geier, Markus Mailänder, Iain Whitehead, Thomas Becker

    In fermentation processes, changes in yeast cell count and substrate concentration are indicators of yeast performance. Therefore, monitoring the composition of the biological suspension, particularly the dispersed solid phase (i.e., yeast cells) and the continuous liquid phase (i.e., medium), is a prerequisite to ensure favorable process conditions. However, the available monitoring methods are often invasive or restricted by detection limits, sampling requirements, or susceptibility to masking effects from interfering signals. In contrast, ultrasound measurements are non-invasive and provide real-time data. In this study, the suitability to characterize the dispersed and the liquid phase of yeast suspensions with ultrasound was investigated. The ultrasound signals collected from three commercially available Saccharomyces yeast were evaluated and compared. For all three yeasts, the attenuation coefficient and speed of sound increased linearly with increasing yeast concentrations (0.0–1.0 wt%) and cell counts (R2 > 0.95). Further characterization of the dispersed phase revealed that cell diameter and volume density influence the attenuation of the ultrasound signal, whereas changes in the speed of sound were partially attributed to compositional variations in the liquid phase. This demonstrates the ability of ultrasound to monitor industrial fermentations and the feasibility of developing targeted control strategies.


  • Open Access

    Ultrasonic mode conversion for in-line foam structure measurement in highly aerated batters using machine learning

    by Michael Metzenmacher, Eva Pfaller, Dominik Geier, Thomas Becker

    An ultrasonic-based method was developed to enable in-line measurements of foam structure parameters for highly aerated batters by mode conversion. Biscuit batters were foamed to different degrees (density: 364–922 g/L) by varying the mixing head speed and pressure. Density and foam structure changes were detected by efficient offline analytics (nref measurement = 96). Ultrasonic signal data were recorded using two ultrasonic sensors attached to an industry-standard tube. Mode conversion effects in the ultrasonic signals were obtained to predict the rheological parameters of the batters. The frequency range in which surface waves are expected was particularly suitable for detecting rheological changes in highly aerated batters. An ultrasonic-based, online-capable method for process monitoring was implemented and established regarding feature selection in combination with machine learning and 5-fold cross-validation. The developed ultrasonic sensor system shows high accuracy for online density measurement (R2 = 0.98) and offers decent accuracy for measurements of foam structure parameters (Bubble count: R2 = 0.95, Relative span: R2 = 0.93, Sauter diameter: R2 = 0.83). The main benefit of this novel technique is that integrating ultrasonic signal features based on mode conversion leads to a robust foam structure analysis, which has the advantage of being retrofitable into existing processes.


  • Open Access

    Improvement of Saccharomyces propagation performance through oxygen-enriched air and aeration parameter variation

    by Alexander Beugholt, Dominik Ulrich Geier, Thomas Becker

    A variety of yeast applications in the food and beverage industry require individual and reproducible yeast propagation at high yields and consistent quality. One quality-determining parameter for yeast propagation is effective aeration to avoid oxygen depletion. Therefore, this work investigated three important aeration parameters: airflow, pulse time, and oxygen concentration, for their influence on yeast propagation. The aeration of a propagator involves phase transitions which are gradient-driven processes and can be accelerated with higher gradients between the liquid medium and the gas bubbles. In this study, oxygen-enriched air generated with membrane filters was used to aerate the system in an easy and cost-efficient way without the need for expensive technical gas usage. Propagation experiments were carried out in a pilot-scale reactor equipped with a membrane filter system for enhanced oxygen concentrations in ingas and online sensors for representative monitoring of the process. The membrane filter system is based on the separation of nitrogen in compressed air, leading to oxygen enrichment. Using oxygen-enriched air for propagation aeration showed higher oxygen transfer into the medium and the anaerobic process time caused by oxygen depletion due to high cell numbers was reduced by an average of 7.4% for pulsed aeration. Additionally, we conducted experiments with controlled measures of dissolved oxygen using different oxygen concentrations for aeration. The main objective of this study is to present a new and affordable optimization of propagation aeration using membrane filtration to enrich process air. The results showed increased cell counts for higher ingas oxygen concentrations and no negative impact on cell vitality was observed. Hence, our investigations showed that using oxygen-enriched air reduced the frequency of pulsed aeration, thus hindering foam formation, a limiting factor of the yeast propagation process.


  • Open Access

    Ultrasonic Wave Mode-Based Application for Contactless Density Measurement of Highly Aerated Batters

    by Michael Metzenmacher, Dominik Geier, Thomas Becker

    An ultrasonic wave mode-based method for density measurement in highly foamed batters was developed. Therefore, a non-contact ultrasonic sensor system was designed to generate signals for batch-wise processes. An ultrasonic sensor, containing a piezoelectric ceramic at the fundamental longitudinal frequency of 2 MHz, was used to take impedance measurements in pulse-echo mode. The ultrasonic signals were processed and analysed wave-mode wise, using a feature-driven approach. The measurements were carried out for different mixing times within a container, with the attached ultrasonic sensor. Within the biscuit batter, the change to the ultrasonic signals caused by density changes during the batter-mixing process was monitored (R2 = 0.96). The density range detected by the sensor ranges between 500 g/L and 1000 g/L. The ultrasonic sensor system developed also shows a reasonable level of accuracy for the measurements of biscuit batter variations (R2 > 0.94). The main benefit of this novel technique, which comprises multiple wave modes for signal features and combines these features with the relevant process parameters, leads to a more robust system as regards to multiple interference factors.