AZAriel Zisman

Ariel Zisman

*This is an algorithmically generated author record based on publicly available information.

Ariel Zisman has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Correction to: Bedtime-to-Morning Glucose Difference and iGlarLixi in Type 2 Diabetes: Post Hoc Analysis of LixiLan-L

    by Ariel Zisman, Terry Dex, Michelle Roberts, Aramesh Saremi, Jason Chao, Vanita R. Aroda

    In the original publication, the text in abstract section under the 'Results' section is incorrectly published as 'higher proportion of patients reached a BeAM value < 55 mg/dL.

  • Open Access

    Bedtime-to-Morning Glucose Difference and iGlarLixi in Type 2 Diabetes: Post Hoc Analysis of LixiLan-L

    by Ariel Zisman, Terry Dex, Michelle Roberts, Aramesh Saremi, Jason Chao, Vanita R. Aroda

    Introduction A difference of ≥ 50–55 mg/dL between bedtime and morning glucose (BeAM) values in patients with type 2 diabetes (T2D) on basal insulin is an indicator of poor postprandial glucose control. This analysis compared the effect of treatment with a fixed-ratio combination of insulin glargine/lixisenatide (iGlarLixi) vs insulin glargine (iGlar) on BeAM values, and evaluated the impact of BeAM values on glycemic and safety endpoints. Methods In this post hoc analysis of 517 participants from the LixiLan-L trial, change in BeAM values and composite efficacy and safety endpoints stratified by BeAM value < 55 mg/dL or ≥ 55 mg/dL were evaluated in patients with T2D uncontrolled on basal insulin randomized to iGlarLixi or iGlar over 30 weeks (LixiLan-L). Results Greater reductions in BeAM values were seen with iGlarLixi vs iGlar, and a higher proportion of patients reached a BeAM value < 55 mg/dL in the iGlarLixi arm. A BeAM value < 55 mg/dL was associated with improved glycemic control, lower risk of hypoglycemia, and a greater proportion of patients achieving glycemic targets without hypoglycemia or weight gain. Greater reductions in BeAM values were seen with iGlarLixi vs iGlar, irrespective of stratification by glycated hemoglobin A1c or glycemic endpoints. Conclusions Greater reductions in bedtime-to-morning glucose differential, or BeAM, were observed with iGlarLixi vs iGlar in patients with T2D uncontrolled on basal insulin, reflecting better overall control of both fasting and prandial glucose and more appropriate matching of therapy to physiologic needs. Trial Registration ClinicalTrials.gov Identifier NCT02058160. Funding Sanofi US, Inc.


  • Open Access

    BeAM value: an indicator of the need to initiate and intensify prandial therapy in patients with type 2 diabetes mellitus receiving basal insulin

    by Ariel Zisman, Francienid Morales, John Stewart, Andreas Stuhr, Aleksandra Vlajnic, Rong Zhou

    Introduction In patients with type 2 diabetes mellitus (T2DM) with uncontrolled glycemia despite ongoing upward titration of basal insulin, targeting postprandial hyperglycemia may be required. Nevertheless, the point at which basal insulin is fully optimized and postprandial glucose (PPG) should be targeted with additional treatment remains unclear. We report here on the BeAM value (difference between bedtime and morning blood glucose values) as an indicator of the need to target PPG. Methods This study had 3 stages: exploratory, main, and proof-of-concept analyses. For the exploratory and main analyses, data were pooled from phase 3 trials in adults with T2DM adding basal insulin to oral antidiabetic drugs (OADs). The main analysis included only patients who did not reach A1C ≤7.0% (53 mmol/mol) at week 24. The proof-of-concept analysis used pooled data from phase 3 trials in adults with T2DM adding insulin glargine and a single insulin glulisine injection to OADs. Results In patients undergoing basal insulin titration, BeAM value increased over 24 weeks (27.8–61.7 mg/dL, n=1188; 32.6–71.2 mg/dL, n=553; exploratory and main analyses, respectively). There were significant correlations between week 24 BeAM value and postprandial contribution to hyperglycemia (Pearson's correlation coefficient (r)=0.375, pConclusions The BeAM value described in this study is a simple, easy-to-calculate value that may identify patients with T2DM using basal insulin that need targeting of postprandial control rather than advancing basal insulin dose.