Hamid Abudhaise
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hamid Abudhaise has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Brian R. Davidson
Affiliation UCL Division of Surgery and Interventional Sciences, Royal Free Hospital, London, United Kingdom
2 shared publicationsA Bashir
University Hospitals Birmingham NHS Foundation Trust, UK
1 shared publicationAaron M. Ranasinghe
From the Department of Cardiac Surgery, UHB NHS FT, Edgbaston, Birmingham, United Kingdom (R.S.B., H.A., M.B., A.M.R.); and the School of Clinical and Experimental Medicine, University of Birmingham, United Kingdom (R.S.B., A.M.R.).
1 shared publicationB Fuller
UCL Division of Surgery and Interventional Sciences, Royal Free Hospital, London, United Kingdom
1 shared publicationB R Davidson
UCL Division of Surgery and Interventional Sciences, Royal Free Hospital, London, United Kingdom
1 shared publicationBarry Fuller
Affiliation UCL Division of Surgery and Interventional Sciences, Royal Free Hospital, London, United Kingdom
1 shared publication
Latest Publications
- Open Access
- 28 October 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (10) , e0257783
Mitochondrial respiratory chain and Krebs cycle enzyme function in human donor livers subjected to end-ischaemic hypothermic machine perfusion
Introduction: Marginal human donor livers are highly susceptible to ischaemia reperfusion injury and mitochondrial dysfunction. Oxygenation during hypothermic machine perfusion (HMP) was proposed to protect the mitochondria but the mechanism is unclear. Additionally, the distribution and uptake of perfusate oxygen during HMP are unknown. This study aimed to examine the feasibility of mitochondrial function analysis during end-ischaemic HMP, assess potential mitochondrial viability biomarkers, and record oxygenation kinetics. Methods: This was a randomised pilot study using human livers retrieved for transplant but not utilised. Livers (n = 38) were randomised at stage 1 into static cold storage (n = 6), hepatic artery HMP (n = 7), and non-oxygen supplemented portal vein HMP (n = 7) and at stage 2 into oxygen supplemented and non-oxygen supplemented portal vein HMP (n = 11 and 7, respectively). Mitochondrial parameters were compared between the groups and between low- and high-risk marginal livers based on donor history, organ steatosis and preservation period. The oxygen delivery efficiency was assessed in additional 6 livers using real-time measurements of perfusate and parenchymal oxygen. Results: The change in mitochondrial respiratory chain (complex I, II, III, IV) and Krebs cycle enzyme activity (aconitase, citrate synthase) before and after 4-hour preservation was not different between groups in both study stages (p > 0.05). Low-risk livers that could have been used clinically (n = 8) had lower complex II-III activities after 4-hour perfusion, compared with high-risk livers (73 nmol/mg/min vs. 113 nmol/mg/min, p = 0.01). Parenchymal pO2 was consistently lower than perfusate pO2 (p ≤ 0.001), stabilised in 28 minutes compared to 3 minutes in perfusate (p = 0.003), and decreased faster upon oxygen cessation (75 vs. 36 minutes, p = 0.003). Conclusions: Actively oxygenated and air-equilibrated end-ischaemic HMP did not induce oxidative damage of aconitase, and respiratory chain complexes remained intact. Mitochondria likely respond to variable perfusate oxygen levels by adapting their respiratory function during end-ischaemic HMP. Complex II-III activities should be further investigated as viability biomarkers.
- 28 October 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (10) , e0257783
Open AccessMitochondrial respiratory chain and Krebs cycle enzyme function in human donor livers subjected to end-ischaemic hypothermic machine perfusion
Introduction: Marginal human donor livers are highly susceptible to ischaemia reperfusion injury and mitochondrial dysfunction. Oxygenation during hypothermic machine perfusion (HMP) was proposed to protect the mitochondria but the mechanism is unclear. Additionally, the distribution and uptake of perfusate oxygen during HMP are unknown. This study aimed to examine the feasibility of mitochondrial function analysis during end-ischaemic HMP, assess potential mitochondrial viability biomarkers, and record oxygenation kinetics. Methods: This was a randomised pilot study using human livers retrieved for transplant but not utilised. Livers (n = 38) were randomised at stage 1 into static cold storage (n = 6), hepatic artery HMP (n = 7), and non-oxygen supplemented portal vein HMP (n = 7) and at stage 2 into oxygen supplemented and non-oxygen supplemented portal vein HMP (n = 11 and 7, respectively). Mitochondrial parameters were compared between the groups and between low- and high-risk marginal livers based on donor history, organ steatosis and preservation period. The oxygen delivery efficiency was assessed in additional 6 livers using real-time measurements of perfusate and parenchymal oxygen. Results: The change in mitochondrial respiratory chain (complex I, II, III, IV) and Krebs cycle enzyme activity (aconitase, citrate synthase) before and after 4-hour preservation was not different between groups in both study stages (p > 0.05). Low-risk livers that could have been used clinically (n = 8) had lower complex II-III activities after 4-hour perfusion, compared with high-risk livers (73 nmol/mg/min vs. 113 nmol/mg/min, p = 0.01). Parenchymal pO2 was consistently lower than perfusate pO2 (p ≤ 0.001), stabilised in 28 minutes compared to 3 minutes in perfusate (p = 0.003), and decreased faster upon oxygen cessation (75 vs. 36 minutes, p = 0.003). Conclusions: Actively oxygenated and air-equilibrated end-ischaemic HMP did not induce oxidative damage of aconitase, and respiratory chain complexes remained intact. Mitochondria likely respond to variable perfusate oxygen levels by adapting their respiratory function during end-ischaemic HMP. Complex II-III activities should be further investigated as viability biomarkers.
- 1 September 2019
- Published by Royal College of Surgeons of England in The Annals of The Royal College of Surgeons of England
- Vol. 101 (7) , 533
The anatomical relationship between the axillary arch of Langer and sentinel lymph node in breast cancer surgery
- 1 September 2019
- Published by Royal College of Surgeons of England in The Annals of The Royal College of Surgeons of England
- Vol. 101 (7) , 533
The anatomical relationship between the axillary arch of Langer and sentinel lymph node in breast cancer surgery
- 1 July 2019
- Published by Elsevier in Transplantation Proceedings
- Vol. 51 (6) , 1679-1683
Reliability and Accuracy of Clinical Assessment and Digital Image Analysis for Steatosis Evaluation in Discarded Human Livers
- 1 July 2019
- Published by Elsevier in Transplantation Proceedings
- Vol. 51 (6) , 1679-1683
Reliability and Accuracy of Clinical Assessment and Digital Image Analysis for Steatosis Evaluation in Discarded Human Livers
- Open Access
- 14 September 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (9) , e0203803
Evolution of dynamic, biochemical, and morphological parameters in hypothermic machine perfusion of human livers: A proof-of-concept study
Hypothermic machine perfusion (HMP) is increasingly investigated as a means to assess liver quality, but data on viability markers is inconsistent and the effects of different perfusion routes and oxygenation on perfusion biomarkers are unclear. This is a single-centre, randomised, multi-arm, parallel study using discarded human livers for evaluation of HMP using arterial, oxygen-supplemented venous and non-oxygen-supplemented venous perfusion. The study included 2 stages: in the first stage, 25 livers were randomised into static cold storage (n = 7), hepatic artery HMP (n = 10), and non-oxygen-supplemented portal vein HMP (n = 8). In the second stage, 20 livers were randomised into oxygen-supplemented and non-oxygen-supplemented portal vein HMP (n = 11 and 9, respectively). Changes in dynamic, biochemical, and morphologic parameters during 4-hour preservation were compared between perfusion groups, and between potentially transplantable and non-transplantable livers. During arterial perfusion, resistance was higher and flow was lower than venous perfusion (p = 0.001 and 0.01, respectively); this was associated with higher perfusate markers during arterial perfusion (p>0.05). Supplementary oxygen did not cause a significant alteration in the studied parameters. Morphology was similar between static and dynamic preservation groups. Perfusate markers were 2 fold higher in non-transplantable livers (p>0.05). Arterial only perfusion might not be adequate for graft perfusion. Hepatocellular injury markers are accessible and easy to perform and could offer insight into graft quality, but large randomised trials are needed to identify reliable quality assessment biomarkers.
- 14 September 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (9) , e0203803
Open AccessEvolution of dynamic, biochemical, and morphological parameters in hypothermic machine perfusion of human livers: A proof-of-concept study
Hypothermic machine perfusion (HMP) is increasingly investigated as a means to assess liver quality, but data on viability markers is inconsistent and the effects of different perfusion routes and oxygenation on perfusion biomarkers are unclear. This is a single-centre, randomised, multi-arm, parallel study using discarded human livers for evaluation of HMP using arterial, oxygen-supplemented venous and non-oxygen-supplemented venous perfusion. The study included 2 stages: in the first stage, 25 livers were randomised into static cold storage (n = 7), hepatic artery HMP (n = 10), and non-oxygen-supplemented portal vein HMP (n = 8). In the second stage, 20 livers were randomised into oxygen-supplemented and non-oxygen-supplemented portal vein HMP (n = 11 and 9, respectively). Changes in dynamic, biochemical, and morphologic parameters during 4-hour preservation were compared between perfusion groups, and between potentially transplantable and non-transplantable livers. During arterial perfusion, resistance was higher and flow was lower than venous perfusion (p = 0.001 and 0.01, respectively); this was associated with higher perfusate markers during arterial perfusion (p>0.05). Supplementary oxygen did not cause a significant alteration in the studied parameters. Morphology was similar between static and dynamic preservation groups. Perfusate markers were 2 fold higher in non-transplantable livers (p>0.05). Arterial only perfusion might not be adequate for graft perfusion. Hepatocellular injury markers are accessible and easy to perform and could offer insight into graft quality, but large randomised trials are needed to identify reliable quality assessment biomarkers.
- Open Access
- 1 July 2014
- Published by Royal College of Surgeons of England in The Annals of The Royal College of Surgeons of England
- Vol. 96 (5) , e3-e4
Delayed aorto-right atrial fistula following percutaneous closure of atrial septal defect
We present the case of a 27-year-old man who underwent percutaneous atrial septal defect (ASD) repair using the Amplatzer® (St Jude Medical, St Paul, MN, US) septal occluder (ASO). Six weeks later, he presented with heart failure and was found to have an aorto-right atrial fistulation. He required urgent surgical device explantation and repair of the existing ASD using a pericardial patch repair technique. This is the first case to be reported from the UK describing a delayed aorto-right atrial fistula following percutaneous closure using ASO.
- 1 July 2014
- Published by Royal College of Surgeons of England in The Annals of The Royal College of Surgeons of England
- Vol. 96 (5) , e3-e4
Open AccessDelayed aorto-right atrial fistula following percutaneous closure of atrial septal defect
We present the case of a 27-year-old man who underwent percutaneous atrial septal defect (ASD) repair using the Amplatzer® (St Jude Medical, St Paul, MN, US) septal occluder (ASO). Six weeks later, he presented with heart failure and was found to have an aorto-right atrial fistulation. He required urgent surgical device explantation and repair of the existing ASD using a pericardial patch repair technique. This is the first case to be reported from the UK describing a delayed aorto-right atrial fistula following percutaneous closure using ASO.
- 17 May 2011
- Published by Wolters Kluwer Health in Circulation
- Vol. 123 (19) , e592-e593
Left Atrial Compression Secondary to Contained Rupture of Type A Aortic Dissection
- 17 May 2011
- Published by Wolters Kluwer Health in Circulation
- Vol. 123 (19) , e592-e593
Left Atrial Compression Secondary to Contained Rupture of Type A Aortic Dissection