Behrouz Nourozi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Behrouz Nourozi has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Qian Wang
KTH Royal Institute of Technology
5 shared publications Adnan Ploskic
2 shared publicationsAdnan Ploskić
2 shared publications- Adnan Ploskić
Bravida Holding AB, Mikrofonvägen 28, SE-12637, Hägersten, Sweden
2 shared publications - Amirmohammad Behzadi
School of Mechanical Engineering, College of Engineering, University of Tehran, P.O. Box 11155-4563, Tehran, Iran
2 shared publications Qian Wang
2 shared publications
Latest Publications
- Open Access
- 30 October 2023
- Published by Elsevier in Building and Environment
- Vol. 247
A systematic review of ventilation solutions for hospital wards: Addressing cross-infection and patient safety
- 30 October 2023
- Published by Elsevier in Building and Environment
- Vol. 247
Open AccessA systematic review of ventilation solutions for hospital wards: Addressing cross-infection and patient safety
- Open Access
- 16 June 2023
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 396, 03014
A smart zero-energy building having bidirectional interaction with electricity/heating networks: An attempt to achieve a higher renewable penetration
The present research introduces an innovative zero-energy building complex equipped with a rule-based control approach for higher integration of renewable resources in the local energy network while bringing down energy costs. The idea centers on establishing several smart controllers to achieve a bidirectional interaction with the heating/electricity network for peak demand shaving and mitigate energy costs. The proposed system comprises Alkaline fuel cells integrated with a hydrogen storage tank driven by either a vanadium chloride cycle or an electrolyzer unit. The system also has an absorption chiller and smart thermal energy storage to supply the heating and cooling demands. TRNSYS-MATLAB developed code is applied to assess the system's indicators from techno-economic standpoints for a residential building complex in the Scandinavian climate. Also, the parametric investigation and time-dependent analysis are carried out to examine the impact of decision parameters and the ambient condition. According to the results, the solar system's physical appearance is very important since it significantly affects performance efficiency and total cost. The results further reveal that picking up the cells' current from 300 A to 500 A improves the performance efficiency by around 12% while lowering the total cost, illustrating the importance of optimization. The results highlight the importance of smart controllers by showing that over 70% of the year's net energy values are positive, indicating that the proposed system may meet demand and sell excess electricity+heating productions to regional networks. The results further demonstrate that since the net energy values are positive for the majority of days in the spring and summer, the system might operate more independently from the local energy networks on warmer days. Eventually, the higher share of solar in summer and wind energy in colder days for hydrogen production shows that the renewable resources combination results in a secure energy supply to obtain the highest independence from the local grid throughout the year.
- 16 June 2023
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 396, 03014
Open AccessA smart zero-energy building having bidirectional interaction with electricity/heating networks: An attempt to achieve a higher renewable penetration
The present research introduces an innovative zero-energy building complex equipped with a rule-based control approach for higher integration of renewable resources in the local energy network while bringing down energy costs. The idea centers on establishing several smart controllers to achieve a bidirectional interaction with the heating/electricity network for peak demand shaving and mitigate energy costs. The proposed system comprises Alkaline fuel cells integrated with a hydrogen storage tank driven by either a vanadium chloride cycle or an electrolyzer unit. The system also has an absorption chiller and smart thermal energy storage to supply the heating and cooling demands. TRNSYS-MATLAB developed code is applied to assess the system's indicators from techno-economic standpoints for a residential building complex in the Scandinavian climate. Also, the parametric investigation and time-dependent analysis are carried out to examine the impact of decision parameters and the ambient condition. According to the results, the solar system's physical appearance is very important since it significantly affects performance efficiency and total cost. The results further reveal that picking up the cells' current from 300 A to 500 A improves the performance efficiency by around 12% while lowering the total cost, illustrating the importance of optimization. The results highlight the importance of smart controllers by showing that over 70% of the year's net energy values are positive, indicating that the proposed system may meet demand and sell excess electricity+heating productions to regional networks. The results further demonstrate that since the net energy values are positive for the majority of days in the spring and summer, the system might operate more independently from the local energy networks on warmer days. Eventually, the higher share of solar in summer and wind energy in colder days for hydrogen production shows that the renewable resources combination results in a secure energy supply to obtain the highest independence from the local grid throughout the year.
- Open Access
- 9 March 2023
- Published by Elsevier in Journal of Energy Storage
- Vol. 63
Provision of multiple services with controllable loads as multi-area thermal energy storage
- 9 March 2023
- Published by Elsevier in Journal of Energy Storage
- Vol. 63
Open AccessProvision of multiple services with controllable loads as multi-area thermal energy storage
- Open Access
- 1 June 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 56
Thermodynamic and thermal comfort performance evaluation of two geothermal high-temperature cooling systems in the mediterranean climate
- 1 June 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 56
Open AccessThermodynamic and thermal comfort performance evaluation of two geothermal high-temperature cooling systems in the mediterranean climate
- Open Access
Design and Parametric Investigation of an Efficient Heating System, an Effort to Obtain a Higher Seasonal Performance Factor
The present work introduces an innovative yet feasible heating system consisting of a ground source heat pump, borehole thermal energy storage, an auxiliary heater, radiators, and ventilation coils. The concept is developed by designing a new piping configuration monitored by a smart control system to reduce the return flow temperature and increase the temperature differential between the supply and return flows. The radiators and ventilation heating circuits are connected in series to provide the heat loads with the same demand. The investigation of the proposed model is performed through developed Python code considering a case study hospital located in Norway. The article presents, after validation of the primary heating system installed in the hospital, a parametric investigation to evaluate the effect of main operational parameters on the performance metrics of both the heat pump and the total system. According to the results, the evaporator temperature is a significant parameter that considerably impacts the system performance. The parametric study findings show that the heat pumps with a thermal capacity of 400 kW and 600 kW lead to the highest heat pump and total seasonal performance factors, respectively. It is also observed that increasing the heat pump capacity does not affect the performance indicators when the condensation temperature is 40 °C and the heat recovery is 50%. Moreover, choosing a heat pump with a smaller capacity at the heat recovery of 75% (or higher) would be an appropriate option because the seasonal performance values are not varied by changing the heat pump capacity. The results reveal that reducing return temperature under a proper parameters selection results in substantially higher seasonal performance factors of the heat pump and total system. These outcomes are in-line with the United Nations sustainable development goals including Sustainable Cities and Communities.
Open AccessDesign and Parametric Investigation of an Efficient Heating System, an Effort to Obtain a Higher Seasonal Performance Factor
The present work introduces an innovative yet feasible heating system consisting of a ground source heat pump, borehole thermal energy storage, an auxiliary heater, radiators, and ventilation coils. The concept is developed by designing a new piping configuration monitored by a smart control system to reduce the return flow temperature and increase the temperature differential between the supply and return flows. The radiators and ventilation heating circuits are connected in series to provide the heat loads with the same demand. The investigation of the proposed model is performed through developed Python code considering a case study hospital located in Norway. The article presents, after validation of the primary heating system installed in the hospital, a parametric investigation to evaluate the effect of main operational parameters on the performance metrics of both the heat pump and the total system. According to the results, the evaporator temperature is a significant parameter that considerably impacts the system performance. The parametric study findings show that the heat pumps with a thermal capacity of 400 kW and 600 kW lead to the highest heat pump and total seasonal performance factors, respectively. It is also observed that increasing the heat pump capacity does not affect the performance indicators when the condensation temperature is 40 °C and the heat recovery is 50%. Moreover, choosing a heat pump with a smaller capacity at the heat recovery of 75% (or higher) would be an appropriate option because the seasonal performance values are not varied by changing the heat pump capacity. The results reveal that reducing return temperature under a proper parameters selection results in substantially higher seasonal performance factors of the heat pump and total system. These outcomes are in-line with the United Nations sustainable development goals including Sustainable Cities and Communities.
- Open Access
- 1 October 2021
- Published by Elsevier in Building and Environment
- Vol. 204
Evaluating the cooling potential of a geothermal-assisted ventilation system for multi-family dwellings in the Scandinavian climate
- 1 October 2021
- Published by Elsevier in Building and Environment
- Vol. 204
Open AccessEvaluating the cooling potential of a geothermal-assisted ventilation system for multi-family dwellings in the Scandinavian climate
- Open Access
- 1 September 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 609 (5) , 052007
Frost reduction in mechanical balanced ventilation by efficient means of preheating cold supply air
This study has focused on evaluating the financial potential of wastewater and geothermal heat recovery systems in a multi-family building. The recovered heat was used to improve the performance of mechanical ventilation with heat recovery (MVHR) system during the coldest days in central Sweden. The main issue, which was targeted with these solutions, was to reduce frost formation in the system and hence increase its thermal efficiency. By looking at the life cycle cost over a lifespan of 20 years, the observed systems were being evaluated economically. Furthermore, statistical analyses were carried-out to counter the uncertainty that comes with the calculation. It was found that the studied wastewater systems have a high possibility of generating savings in this period, while the one fed by geothermal energy is less likely to compensate for its high initial cost. All designed systems however, managed to reduce operational cost by 35-45% due to lower energy usage.
- 1 September 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 609 (5) , 052007
Open AccessFrost reduction in mechanical balanced ventilation by efficient means of preheating cold supply air
This study has focused on evaluating the financial potential of wastewater and geothermal heat recovery systems in a multi-family building. The recovered heat was used to improve the performance of mechanical ventilation with heat recovery (MVHR) system during the coldest days in central Sweden. The main issue, which was targeted with these solutions, was to reduce frost formation in the system and hence increase its thermal efficiency. By looking at the life cycle cost over a lifespan of 20 years, the observed systems were being evaluated economically. Furthermore, statistical analyses were carried-out to counter the uncertainty that comes with the calculation. It was found that the studied wastewater systems have a high possibility of generating savings in this period, while the one fed by geothermal energy is less likely to compensate for its high initial cost. All designed systems however, managed to reduce operational cost by 35-45% due to lower energy usage.
- 1 April 2019
- Published by Elsevier in Resources, Conservation and Recycling
- Vol. 143, 90-98
Maximizing thermal performance of building ventilation using geothermal and wastewater heat
- 1 April 2019
- Published by Elsevier in Resources, Conservation and Recycling
- Vol. 143, 90-98
Maximizing thermal performance of building ventilation using geothermal and wastewater heat
- 1 January 2019
- Published by Elsevier in Applied Thermal Engineering
- Vol. 146, 180-189
Energy and defrosting contributions of preheating cold supply air in buildings with balanced ventilation
- 1 January 2019
- Published by Elsevier in Applied Thermal Engineering
- Vol. 146, 180-189
Energy and defrosting contributions of preheating cold supply air in buildings with balanced ventilation