Katsuyoshi Miura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Katsuyoshi Miura has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
Hiromu Fujioka
3 shared publications- Koji Nakamae
Osaka Univ. (Japan)
3 shared publications Yoshihiro Midoh
Graduate School of Information Science and Technology, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871, Japan
3 shared publicationsKoji Nakamae
Graduate School of Information Science and Technology, Osaka University, Yamada-Oka 1-5, Suita, Osaka 565-0871, Japan
2 shared publicationsAndrew Neureuther
1 shared publicationArsmah Ibrahim
1 shared publication
Latest Publications
- 1 September 2018
- Published by Elsevier in Microelectronics Reliability
- Vol. 88-90, 360-364
Simulation-based evaluation of probing attacks to arbiter PUFs using a time-resolved emission microscope
- 1 September 2018
- Published by Elsevier in Microelectronics Reliability
- Vol. 88-90, 360-364
Simulation-based evaluation of probing attacks to arbiter PUFs using a time-resolved emission microscope
- 1 September 2009
- Published by Elsevier in Microelectronics Reliability
- Vol. 49 (9-11) , 1116-1126
Laser THz emission microscope as a novel tool for LSI failure analysis
- 1 September 2009
- Published by Elsevier in Microelectronics Reliability
- Vol. 49 (9-11) , 1116-1126
Laser THz emission microscope as a novel tool for LSI failure analysis
- 22 January 2005
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 16 (2) , 477-487
Statistical optimization of Canny edge detector for measurement of fine line patterns in SEM image
- 22 January 2005
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 16 (2) , 477-487
Statistical optimization of Canny edge detector for measurement of fine line patterns in SEM image
- 1 January 2005
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 23 (6) , 3065
Pattern matching between a scanning electron microscopy exposed pattern image of large-scale integrated fine structures and computer-aided design layout data by using the relaxation method
A pattern matching technique between a scanning electron microscopy (SEM) exposed pattern image of large-scale integrated fine structures and computer-aided design (CAD) layout data based on the relaxation method is proposed wherein circular arc components are utilized. Edges are extracted from the SEM image and corners in the CAD layout are rounded. The edges in the SEM and CAD layout images are divided into three components: horizontal and vertical straight-line segments, and circular arcs. These components are expressed by bounding boxes; the optimal combination between the SEM and CAD components is then searched by using the probabilistic relaxation method. The mean vector among the obtained shift vectors shows the matching point. We applied our method to SEM exposed pattern images and compared the results with those of the conventional cross-correlation method. The results showed that our method has good robustness against change in shape of exposed pattern. The computation time of our method was comparable to the cross-correlation method.
- 1 January 2005
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 23 (6) , 3065
Pattern matching between a scanning electron microscopy exposed pattern image of large-scale integrated fine structures and computer-aided design layout data by using the relaxation method
A pattern matching technique between a scanning electron microscopy (SEM) exposed pattern image of large-scale integrated fine structures and computer-aided design (CAD) layout data based on the relaxation method is proposed wherein circular arc components are utilized. Edges are extracted from the SEM image and corners in the CAD layout are rounded. The edges in the SEM and CAD layout images are divided into three components: horizontal and vertical straight-line segments, and circular arcs. These components are expressed by bounding boxes; the optimal combination between the SEM and CAD components is then searched by using the probabilistic relaxation method. The mean vector among the obtained shift vectors shows the matching point. We applied our method to SEM exposed pattern images and compared the results with those of the conventional cross-correlation method. The results showed that our method has good robustness against change in shape of exposed pattern. The computation time of our method was comparable to the cross-correlation method.
- 1 November 2004
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 124 (9) , 1046-1052
Vertical Canal Function in Normal Subjects and Patients with Benign Paroxysmal Positional Vertigo
Objectives —To assess the dynamics of the vertical semicircular canal (VSCC)-ocular reflex in normal subjects and then to compare their gain in VSCC-ocular reflex with that of patients with benign paroxysmal positional vertigo (BPPV). Material and Methods —Subjects were sinusoidally rotated around the earth-vertical axis with their head tilted 60° backward and turned 45° to the right or left side from the sagittal plane at frequencies of 0.1, 0.3, 0.5, 0.7 and 1.0 Hz with a maximum angular velocity of 50°/s. Head rotation to the right side on the right anterior semicircular canal (SCC)–left posterior SCC plane or to the left side on the left anterior SCC--right posterior SCC plane stimulated the pair of VSCCs. Eye movements were recorded on a video imaging system with an infrared charge-coupled device camera, using our new technique for analyzing the rotation vector of eye movements in three dimensions. Results —The mean gains in left posterior SCC-ocular reflex in normal subjects ranged from 0.44 at 0.1 Hz to 0.79 at 1.0 Hz, while the mean gains in right anterior SCC-ocular reflex ranged from 0.45 at 0.1 Hz to 0.73 at 1.0 Hz. The mean gains in right posterior SCC-ocular reflex in normal subjects ranged from 0.53 at 0.1 Hz to 0.89 at 1.0 Hz, while the mean gains in left anterior SCC-ocular reflex ranged from 0.53 at 0.1 Hz to 0.88 at 1.0 Hz. Thus, the gains in VSCC-ocular reflex did not differ among the four VSCCs in normal subjects. Similarly, vestibulo-ocular reflex (VOR) gains of the four VSCCs in patients with right- or left-sided BPPV were almost the same at all frequencies compared to those of normal subjects. Conclusion —In patients with BPPV, gains in VOR in the four VSCCs were not changed in comparison with those of normal subjects. It is suggested that the mass of free-floating otoconial debris associated with canalolithiasis was too small compared to that of the endolymph to change the canal dynamics.
- 1 November 2004
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 124 (9) , 1046-1052
Vertical Canal Function in Normal Subjects and Patients with Benign Paroxysmal Positional Vertigo
Objectives —To assess the dynamics of the vertical semicircular canal (VSCC)-ocular reflex in normal subjects and then to compare their gain in VSCC-ocular reflex with that of patients with benign paroxysmal positional vertigo (BPPV). Material and Methods —Subjects were sinusoidally rotated around the earth-vertical axis with their head tilted 60° backward and turned 45° to the right or left side from the sagittal plane at frequencies of 0.1, 0.3, 0.5, 0.7 and 1.0 Hz with a maximum angular velocity of 50°/s. Head rotation to the right side on the right anterior semicircular canal (SCC)–left posterior SCC plane or to the left side on the left anterior SCC--right posterior SCC plane stimulated the pair of VSCCs. Eye movements were recorded on a video imaging system with an infrared charge-coupled device camera, using our new technique for analyzing the rotation vector of eye movements in three dimensions. Results —The mean gains in left posterior SCC-ocular reflex in normal subjects ranged from 0.44 at 0.1 Hz to 0.79 at 1.0 Hz, while the mean gains in right anterior SCC-ocular reflex ranged from 0.45 at 0.1 Hz to 0.73 at 1.0 Hz. The mean gains in right posterior SCC-ocular reflex in normal subjects ranged from 0.53 at 0.1 Hz to 0.89 at 1.0 Hz, while the mean gains in left anterior SCC-ocular reflex ranged from 0.53 at 0.1 Hz to 0.88 at 1.0 Hz. Thus, the gains in VSCC-ocular reflex did not differ among the four VSCCs in normal subjects. Similarly, vestibulo-ocular reflex (VOR) gains of the four VSCCs in patients with right- or left-sided BPPV were almost the same at all frequencies compared to those of normal subjects. Conclusion —In patients with BPPV, gains in VOR in the four VSCCs were not changed in comparison with those of normal subjects. It is suggested that the mass of free-floating otoconial debris associated with canalolithiasis was too small compared to that of the endolymph to change the canal dynamics.
- 19 May 2003
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5011, 190-200
Fine structure measurement in the SEM cross section of LSI using the Canny edge detector
In this paper, we describe a method to optimize parameters of the Canny edge detector, when it is applied to critical dimension (CD) measurements in the cross-sectional scanning electron microscope (SEM) image of the LSI. The Canny is a typical boundary extraction method that convolves the input image with the Laplacian of the Gaussian mask to suppress noise and identify the zero crossing points. The parameters to be optimized are a standard deviation of the Gaussian mask and a threshold value that is used when the zero crossing points are identified. The statistical characteristics of the noise in the SEM image are well known: the major gredient of the SEM image is shot noise. Therefore shot noise is assumed in this method. We apply the method to a model image where shot noise is added and derive the condition where the Canny is effective to measure the fine structure in the image accurately.
- 19 May 2003
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5011, 190-200
Fine structure measurement in the SEM cross section of LSI using the Canny edge detector
In this paper, we describe a method to optimize parameters of the Canny edge detector, when it is applied to critical dimension (CD) measurements in the cross-sectional scanning electron microscope (SEM) image of the LSI. The Canny is a typical boundary extraction method that convolves the input image with the Laplacian of the Gaussian mask to suppress noise and identify the zero crossing points. The parameters to be optimized are a standard deviation of the Gaussian mask and a threshold value that is used when the zero crossing points are identified. The statistical characteristics of the noise in the SEM image are well known: the major gredient of the SEM image is shot noise. Therefore shot noise is assumed in this method. We apply the method to a model image where shot noise is added and derive the condition where the Canny is effective to measure the fine structure in the image accurately.