Haiping Ren
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Haiping Ren has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Chenxi Wang
National Institutes for Food and Drug Control, Beijing 100050
1 shared publication - Hao Wang
Institute for Medical Device Control, National Institutes for Food and Drug Control, Beijing 102629, China
1 shared publication Quan Wang
1 shared publication- Quan Wang
National Institutes for Food and Drug Control, Institute for Medical Devices Control, Beijing 102629, China
1 shared publication - Shu Li
Institute for Medical Device Control, National Institutes for Food and Drug Control, Beijing, China
1 shared publication - Zengwen Su
National Institutes for Food and Drug Control, Institute for Medical Devices Control, Beijing 102629, China
1 shared publication
Latest Publications
- Open Access
- 15 October 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (10) , 1929
Research on an Anthropomorphic Phantom for Evaluation of the Medical Device Electromagnetic Field Exposure SAR
A medical device will emit electromagnetic radiation to its surrounding environment either actively or passively. However, clinicians are unaware as to whether the ambient electromagnetic radiation will exceed the human body’s endurance capacity. In this paper, the mathematical model of electromagnetic parameters devoted to Specific Absorption Rate (SAR) testing of medical devices was established using a Debye Model. Body liquids featuring dielectric properties including the conductivity and permittivity of tissues at various body parts were simulated on the basis of results derived from the model. A simplified anthropomorphic phantom for the SAR test was founded on the basis of geometric parameters by following the principles of resemblance and consistent conductivity. A full-band electromagnetic mathematical model of brain, muscle, heart, lungs, stomach, and kidneys was set up. Electromagnetic radiation levels of a wearable Electrocardiograph monitoring device were measured and found that the maximum electric field intensity was up to 30 V/m, and the electromagnetic radiation SAR value was 0.96 W/kg, which were equivalent to the electromagnetic radiation exposure of the occupational group. The results established that electromagnetic radiation of certain medical devices exceeded the allowed values specified by the World Health Organization (WHO). Therefore, further studies within the field of medicine are required to decide whether additional evaluation measures should be required.
- 15 October 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (10) , 1929
Open AccessResearch on an Anthropomorphic Phantom for Evaluation of the Medical Device Electromagnetic Field Exposure SAR
A medical device will emit electromagnetic radiation to its surrounding environment either actively or passively. However, clinicians are unaware as to whether the ambient electromagnetic radiation will exceed the human body’s endurance capacity. In this paper, the mathematical model of electromagnetic parameters devoted to Specific Absorption Rate (SAR) testing of medical devices was established using a Debye Model. Body liquids featuring dielectric properties including the conductivity and permittivity of tissues at various body parts were simulated on the basis of results derived from the model. A simplified anthropomorphic phantom for the SAR test was founded on the basis of geometric parameters by following the principles of resemblance and consistent conductivity. A full-band electromagnetic mathematical model of brain, muscle, heart, lungs, stomach, and kidneys was set up. Electromagnetic radiation levels of a wearable Electrocardiograph monitoring device were measured and found that the maximum electric field intensity was up to 30 V/m, and the electromagnetic radiation SAR value was 0.96 W/kg, which were equivalent to the electromagnetic radiation exposure of the occupational group. The results established that electromagnetic radiation of certain medical devices exceeded the allowed values specified by the World Health Organization (WHO). Therefore, further studies within the field of medicine are required to decide whether additional evaluation measures should be required.
- 1 May 2013
- Vol. 37 (3) , 178-81
[Realization of DICOM medical image compression technology].
This paper introduces the implement method of DICOM medical image compression technology, The image part of DICOM files are extracted and converted to BMP format. The non-image information in DICOM file are stored into the text. When the final image of JPEG standard and non-image information are encapsulated to DICOM format images, it realizes the compression of medical image, which is beneficial to the image storage and transmission.
- 1 May 2013
- Vol. 37 (3) , 178-81
[Realization of DICOM medical image compression technology].
This paper introduces the implement method of DICOM medical image compression technology, The image part of DICOM files are extracted and converted to BMP format. The non-image information in DICOM file are stored into the text. When the final image of JPEG standard and non-image information are encapsulated to DICOM format images, it realizes the compression of medical image, which is beneficial to the image storage and transmission.