Hossein Eivaz Mohammadloo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hossein Eivaz Mohammadloo has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Helia Heydarinasab
Department of Polymer Engineering and Color Technology, Amirkabir University of Technology, Tehran, Iran
3 shared publications- Bahram Ramezanzadeh
Department of Surface Coatings and Corrosion, Institute for Color Science and Technology, Tehran, Iran
2 shared publications - Faramarz Afshar Taromi
Department of Polymer Engineering and Color Technology, Amirkabir University of Technology (Tehran Polytechnic), Tehran P.O. Box 15875-4413, Iran
2 shared publications M. H. Shahini
Mining and Metallurgical Engineering Department, Amirkabir University of Technology, Tehran, Iran
2 shared publicationsM. Khorasani
Department of Polymer Engineering and Color Technology, Amirkabir University of Technology, Tehran, Iran
2 shared publicationsMaryam Nikpayam
Chemistry Department, Oregon State University, Corvallis, USA
2 shared publications
Latest Publications
- Open Access
- 13 May 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Synergistic effect of rare-earth and transition metal conversion coatings on bioactive hydroxyapatite mineralization and electrochemical behavior of AZ31 magnesium alloys
Cerium–vanadium conversion coatings were investigated as pretreatment layers to improve hydroxyapatite (HA) deposition on AZ31 magnesium alloy for enhanced corrosion protection and in-vitro bioactivity. Cerium-only (CeCC), vanadium-only (VCC), and a mixed Ce/V conversion coating (CeVCC) were prepared, and the optimized mixed conversion layer was subsequently used as the pretreatment for HA deposition to form a CeVCC + HA hybrid coating. Surface morphology and elemental composition were characterized by SEM/EDS, while wettability and surface functional groups were evaluated using static water contact-angle measurements and ATR-FTIR, respectively. Corrosion behavior in simulated body fluid (SBF) was assessed by electrochemical impedance spectroscopy (EIS) during prolonged immersion, complemented by hydrogen evolution measurements as kinetic indicators of Mg degradation. The CeVCC pretreatment produced a more compact and uniform surface and promoted homogeneous HA growth with improved interfacial integrity. Compared with bare AZ31 and single-layer coatings, the CeVCC + HA hybrid exhibited a higher impedance response and lower hydrogen evolution, indicating a markedly lower corrosion rate, while retaining Ca–P surface characteristics associated with bioactive behavior in SBF. These results demonstrate that Ce/V conversion pretreatment is an effective strategy for stabilizing HA coatings on Mg alloys and improving their performance in physiological environments.
- 13 May 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessSynergistic effect of rare-earth and transition metal conversion coatings on bioactive hydroxyapatite mineralization and electrochemical behavior of AZ31 magnesium alloys
Cerium–vanadium conversion coatings were investigated as pretreatment layers to improve hydroxyapatite (HA) deposition on AZ31 magnesium alloy for enhanced corrosion protection and in-vitro bioactivity. Cerium-only (CeCC), vanadium-only (VCC), and a mixed Ce/V conversion coating (CeVCC) were prepared, and the optimized mixed conversion layer was subsequently used as the pretreatment for HA deposition to form a CeVCC + HA hybrid coating. Surface morphology and elemental composition were characterized by SEM/EDS, while wettability and surface functional groups were evaluated using static water contact-angle measurements and ATR-FTIR, respectively. Corrosion behavior in simulated body fluid (SBF) was assessed by electrochemical impedance spectroscopy (EIS) during prolonged immersion, complemented by hydrogen evolution measurements as kinetic indicators of Mg degradation. The CeVCC pretreatment produced a more compact and uniform surface and promoted homogeneous HA growth with improved interfacial integrity. Compared with bare AZ31 and single-layer coatings, the CeVCC + HA hybrid exhibited a higher impedance response and lower hydrogen evolution, indicating a markedly lower corrosion rate, while retaining Ca–P surface characteristics associated with bioactive behavior in SBF. These results demonstrate that Ce/V conversion pretreatment is an effective strategy for stabilizing HA coatings on Mg alloys and improving their performance in physiological environments.
- 3 February 2026
- Published by IOP Publishing in Biomedical Materials
- Vol. 21 (2)
Polymeric Coatings Integrated with Drug-Loaded Micro and Nanostructures for Bioimplant Applications
Biomedical implants play a critical role in restoring tissue function; however, their long-term performance is often hindered by challenges such as infection, inflammation, and poor integration with the host tissue. Recent advances in polymer-based coatings, particularly those incorporating drug-loaded microparticles and nanostructured fillers, have demonstrated outstanding potential in overcoming these limitations. These multifunctional coatings not only enhance biocompatibility and mechanical stability but also enable controlled, localized drug delivery, thereby reducing systemic side effects and improving therapeutic outcomes. This review differentiate three different categories of polymer coatings which can be mostly found in research works including: Natural polymers with their remarkable promise due to their biodegradability, inherent bioactivity, and ability to support cell adhesion and tissue regeneration; Synthetic polymers, which can further contribute tunable degradation rates and mechanical versatility, making them suitable for a wide range of clinical applications; Hybrid/composite coatings, whose design rely on integrating both natural and synthetic polymers to enable to tackle more bottlenecks and expand the therapeutic scope of implants by providing infection resistance, anti-inflammatory effects, and osteogenic stimulation. Furthermore, this review brings together recent advances in micro- and nanoengineered drug-eluting coatings for medical implants, highlighting their design strategies, functional performance, and clinical relevance. Emerging trends and future directions are discussed to underscore the transformative potential of these systems in advancing next-generation implantable medical devices.
- 3 February 2026
- Published by IOP Publishing in Biomedical Materials
- Vol. 21 (2)
Polymeric Coatings Integrated with Drug-Loaded Micro and Nanostructures for Bioimplant Applications
Biomedical implants play a critical role in restoring tissue function; however, their long-term performance is often hindered by challenges such as infection, inflammation, and poor integration with the host tissue. Recent advances in polymer-based coatings, particularly those incorporating drug-loaded microparticles and nanostructured fillers, have demonstrated outstanding potential in overcoming these limitations. These multifunctional coatings not only enhance biocompatibility and mechanical stability but also enable controlled, localized drug delivery, thereby reducing systemic side effects and improving therapeutic outcomes. This review differentiate three different categories of polymer coatings which can be mostly found in research works including: Natural polymers with their remarkable promise due to their biodegradability, inherent bioactivity, and ability to support cell adhesion and tissue regeneration; Synthetic polymers, which can further contribute tunable degradation rates and mechanical versatility, making them suitable for a wide range of clinical applications; Hybrid/composite coatings, whose design rely on integrating both natural and synthetic polymers to enable to tackle more bottlenecks and expand the therapeutic scope of implants by providing infection resistance, anti-inflammatory effects, and osteogenic stimulation. Furthermore, this review brings together recent advances in micro- and nanoengineered drug-eluting coatings for medical implants, highlighting their design strategies, functional performance, and clinical relevance. Emerging trends and future directions are discussed to underscore the transformative potential of these systems in advancing next-generation implantable medical devices.
- Open Access
- 16 July 2025
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 37, 4949-4972
Recent progress in smart coatings for Mg implants: Functional strategies for corrosion protection
- 16 July 2025
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 37, 4949-4972
Open AccessRecent progress in smart coatings for Mg implants: Functional strategies for corrosion protection
- 2 July 2025
- Published by Elsevier in Advances in Colloid and Interface Science
- Vol. 344, 103592
Multi-metal/ligand MOFs: Transformative materials for energy storage, photocatalysis, and sensor technologies
- 2 July 2025
- Published by Elsevier in Advances in Colloid and Interface Science
- Vol. 344, 103592
Multi-metal/ligand MOFs: Transformative materials for energy storage, photocatalysis, and sensor technologies
- 11 January 2025
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 296, 139792
Tartaric acid, an effective additive to improve the surface properties and bio-corrosion resistance of HA-coated magnesium-based implants
- 11 January 2025
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 296, 139792
Tartaric acid, an effective additive to improve the surface properties and bio-corrosion resistance of HA-coated magnesium-based implants
- RetractedOpen Access
RETRACTED: Hydroxyapatite-based coatings on Mg and Ti-based implants: A detailed examination of various coating methodologies
- Open Access
Maximizing Corrosion Resistance of HA+Ce Coated Mg Implants Using Random Forest and Whale Optimization Algorithm
In this paper, a hybrid three-stage methodology based on in vitro experiments, simulations, and metaheuristic optimization is presented to enhance the corrosion resistance of hydroxyapatite (HA)-coated magnesium implants in biomedical applications. In the first stage, we add cerium (Ce) to HA and present a new coating (named HA+Ce) to improve the resistance of the coating to corrosion. Then, various HA+Ce compounds with different factors (e.g., concentration, pH, immersion time, and temperature) are generated and their propensity for corrosion is examined in a physiological environment using EIS and DC polarization tests in a simulated body fluid solution. Eventually, a comprehensive dataset comprising 1024 HA+Ce coating samples is collected. In the second stage, machine learning using random forest (RF) is used to learn the relation between the input factors of the coating and its corrosion resistance. In the third stage, a metaheuristic algorithm based on the whale optimization algorithm (WOA) is utilized to find the best HA+Ce compound with the maximum corrosion resistance, while the objective function of WOA for a new unseen coating solution is estimated using the trained RF model. Finally, the morphology and composition of the best coating solution are inspected using FE-SEM. According to the obtained results, the HA+Ce coating with an immersion time of 60 min, concentrations of 0.9 for Ce and 1.2 for HA, pH of 4.1 for solution, and temperature of 70 °C demonstrated the highest level of corrosion resistance among all experiments and simulations. The final optimized HA+Ce coating solution has obtained a corrosion resistance of 14,050 Ω·cm2, which resulted in a gain of 14.9% compared to the HA-coated Mg implants.
Open AccessMaximizing Corrosion Resistance of HA+Ce Coated Mg Implants Using Random Forest and Whale Optimization Algorithm
In this paper, a hybrid three-stage methodology based on in vitro experiments, simulations, and metaheuristic optimization is presented to enhance the corrosion resistance of hydroxyapatite (HA)-coated magnesium implants in biomedical applications. In the first stage, we add cerium (Ce) to HA and present a new coating (named HA+Ce) to improve the resistance of the coating to corrosion. Then, various HA+Ce compounds with different factors (e.g., concentration, pH, immersion time, and temperature) are generated and their propensity for corrosion is examined in a physiological environment using EIS and DC polarization tests in a simulated body fluid solution. Eventually, a comprehensive dataset comprising 1024 HA+Ce coating samples is collected. In the second stage, machine learning using random forest (RF) is used to learn the relation between the input factors of the coating and its corrosion resistance. In the third stage, a metaheuristic algorithm based on the whale optimization algorithm (WOA) is utilized to find the best HA+Ce compound with the maximum corrosion resistance, while the objective function of WOA for a new unseen coating solution is estimated using the trained RF model. Finally, the morphology and composition of the best coating solution are inspected using FE-SEM. According to the obtained results, the HA+Ce coating with an immersion time of 60 min, concentrations of 0.9 for Ce and 1.2 for HA, pH of 4.1 for solution, and temperature of 70 °C demonstrated the highest level of corrosion resistance among all experiments and simulations. The final optimized HA+Ce coating solution has obtained a corrosion resistance of 14,050 Ω·cm2, which resulted in a gain of 14.9% compared to the HA-coated Mg implants.
- Open Access
Investigating the Concurrent Effect of Cerium/Hydroxyapatite Coatings on Mg-Based Implant for Enhancing Corrosion Performance and In-Vitro Activity
Magnesium alloy is emerging as a leading choice for biodegradable orthopedic implants, thanks to its superior biocompatibility and mechanical characteristics that align with those of natural bone. Nonetheless, its swift corrosion rate poses a challenge to its use in clinical settings. In this study, two methods were used to apply Cerium and Hydroxyapatite (HA) coatings on Mg AZ31 implants, specifically a one-step process (HA + Ce) and a two-step process (HA + Ce/CeCC), with the aim of improving their resistance to corrosion. The susceptibility of the samples to corrosion and the efficiency of the coatings in a physiological media were evaluated using Electrochemical Impedance Spectroscopy (EIS) and Direct Current (DC) polarization tests in a Simulated Body Fluid (SBF) solution. In the HA + Ce sample, the effect of immersion time was also examined. The Field Emission Scanning Electron Microscope (FE-SEM) results showed that after 15 min of coating process, a very weak and uneven coating is formed on the surface. However, at 30 and 60 min, the structure of the coating changes, forming a more crystalline and denser coating on the surface, which also has greater corrosion resistance. The results of the electrochemical tests showed that the sample prepared using the two-step method (HA + Ce/CeCC sample) had the highest resistance to both corrosion and biocorrosion. The morphology and composition of the coatings were inspected using FE-SEM and X-ray diffraction (XRD), confirming the formation of HA crystals and an amorphous layer of Cerium. Moreover, the HA + Ce/CeCC sample demonstrated the highest level of corrosion resistance in an Simulated Body Fluid (SBF) media over an extended duration of submersion.
Open AccessInvestigating the Concurrent Effect of Cerium/Hydroxyapatite Coatings on Mg-Based Implant for Enhancing Corrosion Performance and In-Vitro Activity
Magnesium alloy is emerging as a leading choice for biodegradable orthopedic implants, thanks to its superior biocompatibility and mechanical characteristics that align with those of natural bone. Nonetheless, its swift corrosion rate poses a challenge to its use in clinical settings. In this study, two methods were used to apply Cerium and Hydroxyapatite (HA) coatings on Mg AZ31 implants, specifically a one-step process (HA + Ce) and a two-step process (HA + Ce/CeCC), with the aim of improving their resistance to corrosion. The susceptibility of the samples to corrosion and the efficiency of the coatings in a physiological media were evaluated using Electrochemical Impedance Spectroscopy (EIS) and Direct Current (DC) polarization tests in a Simulated Body Fluid (SBF) solution. In the HA + Ce sample, the effect of immersion time was also examined. The Field Emission Scanning Electron Microscope (FE-SEM) results showed that after 15 min of coating process, a very weak and uneven coating is formed on the surface. However, at 30 and 60 min, the structure of the coating changes, forming a more crystalline and denser coating on the surface, which also has greater corrosion resistance. The results of the electrochemical tests showed that the sample prepared using the two-step method (HA + Ce/CeCC sample) had the highest resistance to both corrosion and biocorrosion. The morphology and composition of the coatings were inspected using FE-SEM and X-ray diffraction (XRD), confirming the formation of HA crystals and an amorphous layer of Cerium. Moreover, the HA + Ce/CeCC sample demonstrated the highest level of corrosion resistance in an Simulated Body Fluid (SBF) media over an extended duration of submersion.