Satoru Kobayashi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Satoru Kobayashi has a total of 130 co-authors. Here are the top co-authors by number of shared publications:
- Toshiyuki Iwamoto
The University of Tokyo, 7-3-1 Hongo Bunkyo-ku, Tokyo, Japan
7 shared publications K. Ieki
5 shared publicationsR. Onda
4 shared publicationsS. Ogawa
4 shared publicationsToshinori Mori
International Center for Elementary Particle Physics (ICEPP) The University of Tokyo 113-0033 Tokyo Japan
4 shared publicationsW. Ootani
4 shared publications
Latest Publications
- 15 May 2023
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1053
Study on degradation of VUV-sensitivity of MPPC for liquid xenon scintillation detector by radiation damage in MEG II experiment
- 15 May 2023
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1053
Study on degradation of VUV-sensitivity of MPPC for liquid xenon scintillation detector by radiation damage in MEG II experiment
- Open Access
Study on degradation of VUV-sensitivity of MPPC for liquid xenon scintillation detector by radiation damage in MEG II experiment
In the MEG II experiment, the liquid xenon gamma-ray detector uses Multi-Pixel Photon Counters (MPPC) which are sensitive to vacuum ultraviolet (VUV) light under a high-intensity muon beam environment. In the commissioning phase of the detector with the beam, a significant degradation in the photon detection efficiency (PDE) for VUV light was found, while the degradation in the PDE for visible light was much less significant. This implies that the radiation damage is localized to the surface of the MPPC where incoming VUV photons create electron-hole pairs. It was also found that the PDE can recover to the original level by thermal annealing.
Open AccessStudy on degradation of VUV-sensitivity of MPPC for liquid xenon scintillation detector by radiation damage in MEG II experiment
In the MEG II experiment, the liquid xenon gamma-ray detector uses Multi-Pixel Photon Counters (MPPC) which are sensitive to vacuum ultraviolet (VUV) light under a high-intensity muon beam environment. In the commissioning phase of the detector with the beam, a significant degradation in the photon detection efficiency (PDE) for VUV light was found, while the degradation in the PDE for visible light was much less significant. This implies that the radiation damage is localized to the surface of the MPPC where incoming VUV photons create electron-hole pairs. It was also found that the PDE can recover to the original level by thermal annealing.
- Open Access
Towards a New μ→eγ Search with the MEG II Experiment: From Design to Commissioning
The MEG experiment represents the state of the art in the search for the Charged Lepton Flavour Violating decay. With its first phase of operations at the Paul Scherrer Institut (PSI), MEG set the most stringent upper limit on the BR at confidence level, imposing one of the tightest constraints on models predicting LFV-enhancements through new physics beyond the Standard Model. An upgrade of the MEG experiment, MEG II, was designed and it is presently in the commissioning phase, aiming at a sensitivity level of . The MEG II experiment relies on a series of upgrades, which include an improvement of the photon detector resolutions, brand new detectors on the positron side with better acceptance, efficiency and performances and new and optimized trigger and DAQ electronics to exploit a muon beam intensity twice as high as that of MEG ( /s). This paper presents a complete overview of the MEG II experimental apparatus and the current status of the detector commissioning in view of the physics data taking in the upcoming three years.Open AccessTowards a New μ→eγ Search with the MEG II Experiment: From Design to Commissioning
The MEG experiment represents the state of the art in the search for the Charged Lepton Flavour Violating decay. With its first phase of operations at the Paul Scherrer Institut (PSI), MEG set the most stringent upper limit on the BR at confidence level, imposing one of the tightest constraints on models predicting LFV-enhancements through new physics beyond the Standard Model. An upgrade of the MEG experiment, MEG II, was designed and it is presently in the commissioning phase, aiming at a sensitivity level of . The MEG II experiment relies on a series of upgrades, which include an improvement of the photon detector resolutions, brand new detectors on the positron side with better acceptance, efficiency and performances and new and optimized trigger and DAQ electronics to exploit a muon beam intensity twice as high as that of MEG ( /s). This paper presents a complete overview of the MEG II experimental apparatus and the current status of the detector commissioning in view of the physics data taking in the upcoming three years. - Open Access
The Search for μ+ → e+γ with 10–14 Sensitivity: The Upgrade of the MEG Experiment
The MEG experiment took data at the Paul Scherrer Institute in the years 2009–2013 to test the violation of the lepton flavor conservation law, which originates from an accidental symmetry that the Standard Model of elementary particle physics has, and published the most stringent limit on the charged lepton flavor violating decay : BR() at confidence level. The MEG detector has been upgraded in order to reach a sensitivity of . The basic principle of MEG II is to achieve the highest possible sensitivity using the full muon beam intensity at the Paul Scherrer Institute ( muons/s) with an upgraded detector. The main improvements are better rate capability of all sub-detectors and improved resolutions while keeping the same detector concept. In this paper, we present the current status of the preparation, integration and commissioning of the MEG II detector in the recent engineering runs.Open AccessThe Search for μ+ → e+γ with 10–14 Sensitivity: The Upgrade of the MEG Experiment
The MEG experiment took data at the Paul Scherrer Institute in the years 2009–2013 to test the violation of the lepton flavor conservation law, which originates from an accidental symmetry that the Standard Model of elementary particle physics has, and published the most stringent limit on the charged lepton flavor violating decay : BR() at confidence level. The MEG detector has been upgraded in order to reach a sensitivity of . The basic principle of MEG II is to achieve the highest possible sensitivity using the full muon beam intensity at the Paul Scherrer Institute ( muons/s) with an upgraded detector. The main improvements are better rate capability of all sub-detectors and improved resolutions while keeping the same detector concept. In this paper, we present the current status of the preparation, integration and commissioning of the MEG II detector in the recent engineering runs. - Open Access
- 13 November 2019
- Published by Physical Society of Japan
A Comparative Study on Various Methods for SiPM Gain Calibration
- 13 November 2019
- Published by Physical Society of Japan
Open AccessA Comparative Study on Various Methods for SiPM Gain Calibration
- Open Access
- 13 November 2019
- Published by Physical Society of Japan
Scintillator Hodoscope with a Few Millimeter Position Resolution for Cosmic-ray Test Stand
- 13 November 2019
- Published by Physical Society of Japan
Open AccessScintillator Hodoscope with a Few Millimeter Position Resolution for Cosmic-ray Test Stand
- Open Access
- 2 August 2019
- Published by Sissa Medialab Srl
Commissioning of liquid Xe detector with VUV-MPPC readout for MEG II experiment
- 2 August 2019
- Published by Sissa Medialab Srl
Open AccessCommissioning of liquid Xe detector with VUV-MPPC readout for MEG II experiment