Patrizia Sulser
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Patrizia Sulser has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Adrian Dalbert
Department of Otorhinolaryngology, Head and Neck Surgery University Hospital Zurich, University of Zurich Zurich Switzerland
1 shared publication - Alexander M. Huber
Department of Otorhinolaryngology – Head and Neck Surgery University Hospital Zurich Zürich Switzerland
1 shared publication - Christof Röösli
Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Zurich, University of Zurich, 8091 Zurich, Switzerland
1 shared publication - Dominik Obrist
University of Bern
1 shared publication - Dominik Péus
Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Zurich, University of Zurich, 8091 Zurich, Switzerland
1 shared publication - Flurin Pfiffner
Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Zurich, University of Zurich 1 , 8091 Zurich
1 shared publication
Latest Publications
- Open Access
Proof of Concept for an Intracochlear Acoustic Receiver for Use in Acute Large Animal Experiments
(1) Background: The measurement of intracochlear sound pressure (ICSP) is relevant to obtain better understanding of the biomechanics of hearing. The goal of this work was a proof of concept of a partially implantable intracochlear acoustic receiver (ICAR) fulfilling all requirements for acute ICSP measurements in a large animal. The ICAR was designed not only to be used in chronic animal experiments but also as a microphone for totally implantable cochlear implants (TICI). (2) Methods: The ICAR concept was based on a commercial MEMS condenser microphone customized with a protective diaphragm that provided a seal and optimized geometry for accessing the cochlea. The ICAR was validated under laboratory conditions and using in-vivo experiments in sheep. (3) Results: For the first time acute ICSP measurements were successfully performed in a live specimen that is representative of the anatomy and physiology of the human. Data obtained are in agreement with published data from cadavers. The surgeons reported high levels of ease of use and satisfaction with the system design. (4) Conclusions: Our results confirm that the developed ICAR can be used to measure ICSP in acute experiments. The next generation of the ICAR will be used in chronic sheep experiments and in TICI.
Open AccessProof of Concept for an Intracochlear Acoustic Receiver for Use in Acute Large Animal Experiments
(1) Background: The measurement of intracochlear sound pressure (ICSP) is relevant to obtain better understanding of the biomechanics of hearing. The goal of this work was a proof of concept of a partially implantable intracochlear acoustic receiver (ICAR) fulfilling all requirements for acute ICSP measurements in a large animal. The ICAR was designed not only to be used in chronic animal experiments but also as a microphone for totally implantable cochlear implants (TICI). (2) Methods: The ICAR concept was based on a commercial MEMS condenser microphone customized with a protective diaphragm that provided a seal and optimized geometry for accessing the cochlea. The ICAR was validated under laboratory conditions and using in-vivo experiments in sheep. (3) Results: For the first time acute ICSP measurements were successfully performed in a live specimen that is representative of the anatomy and physiology of the human. Data obtained are in agreement with published data from cadavers. The surgeons reported high levels of ease of use and satisfaction with the system design. (4) Conclusions: Our results confirm that the developed ICAR can be used to measure ICSP in acute experiments. The next generation of the ICAR will be used in chronic sheep experiments and in TICI.