Xiaomin Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xiaomin Wang has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Zexiao Xie
4 shared publications- Zhou Zheng
College of Electrical Engineering and Automation, Shandong University of Science and Technology, Qingdao, China
4 shared publications Zhendong Sun
3 shared publicationsBenoit Clement
Ecole National Supérieure de Techniques Avancées (ENSTA) Bretagne, Brest, France
2 shared publicationsNingning Li
2 shared publicationsRuiyao Wang
2 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 14 (19) , 1817
RGB-Derived Multi-Representation Texture Enhancement for Underwater Object Detection
Underwater object detection is hindered by haze, color distortion, and weak object boundaries. This study develops MTUDNet, a YOLOv8n-based framework that combines a dehazed appearance, RGB-derived pseudo-depth, and depth-guided texture cues with frequency-spatial-channel attention and a boundary-adaptive box loss. The contribution lies in their task-oriented integration and in the boundary-discrepancy regression design; the dehazing and monocular depth estimators are adopted from prior work. Relative to YOLOv8n, MTUDNet increases mAP@0.5:0.95 by 6.6, 5.8, and 11.7 percentage points on DUO, UODD, and RUOD, respectively. It obtains 53.4% mAP@0.5:0.95 on UODD with 4.3 million detector parameters. Comparisons with U-DECN and GCC-Net show that this compact detector does not lead every accuracy metric. The 4.3 million parameters characterize the detector only; full-pipeline latency is not reported. Future work will measure complete inference time and assess pseudo-depth reliability under changing underwater conditions.
- 1 October 2026
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 14 (19) , 1817
Open AccessRGB-Derived Multi-Representation Texture Enhancement for Underwater Object Detection
Underwater object detection is hindered by haze, color distortion, and weak object boundaries. This study develops MTUDNet, a YOLOv8n-based framework that combines a dehazed appearance, RGB-derived pseudo-depth, and depth-guided texture cues with frequency-spatial-channel attention and a boundary-adaptive box loss. The contribution lies in their task-oriented integration and in the boundary-discrepancy regression design; the dehazing and monocular depth estimators are adopted from prior work. Relative to YOLOv8n, MTUDNet increases mAP@0.5:0.95 by 6.6, 5.8, and 11.7 percentage points on DUO, UODD, and RUOD, respectively. It obtains 53.4% mAP@0.5:0.95 on UODD with 4.3 million detector parameters. Comparisons with U-DECN and GCC-Net show that this compact detector does not lead every accuracy metric. The 4.3 million parameters characterize the detector only; full-pipeline latency is not reported. Future work will measure complete inference time and assess pseudo-depth reliability under changing underwater conditions.
- 25 June 2026
- Published by Elsevier in Pattern Recognition
- Vol. 180
RDFNet-SLAM: A deep learning-based RGB-D SLAM system for challenging indoor scenarios
- 25 June 2026
- Published by Elsevier in Pattern Recognition
- Vol. 180
RDFNet-SLAM: A deep learning-based RGB-D SLAM system for challenging indoor scenarios
- 13 June 2026
- Published by Elsevier in Measurement
- Vol. 284
A deep learning-assisted fingertip localization system based on CMUT arrays
- 13 June 2026
- Published by Elsevier in Measurement
- Vol. 284
A deep learning-assisted fingertip localization system based on CMUT arrays
- 3 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 5011614
A Distributed Underwater Structured-Light System: Refraction Compensation, Global Calibration, and Nuclear Metrology
Nuclear fuel assemblies are core reactor components whose geometric integrity is vital for thermal-hydraulic safety and control-rod insertion. This paper presents a high-precision underwater 3-D measurement system for full-scale deformation monitoring of fuel assemblies using a distributed network of non-overlapping binocular structured-light sensors. A virtual-image-plane-based global extrinsic calibration framework is developed to unify all units into a common coordinate system. To eliminate underwater imaging errors, a physical mitigate asymmetric refractive deviations caused by interface tilts, an innovative refraction-equivalent distortion compensation model and a thin-prism-based calibration strategy are introduced is proposed, which mathematically maps the complex multi-media physical tilt into an internal thin-prism distortion . The system’s performance has been validated using a full-scale simulated fuel assembly. Results demonstrate a maximum measurement deviation of less than 0.48 mm over a large measurement envelope (4050 × 1200 × 1200 mm), with bending errors within 0.44mm and twisting errors below 0.06◦ underwater. This system provides a robust, non-contact solution for the structural health monitoring of nuclear fuel, offering significant practical value for nuclear plant maintenance.
- 3 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 5011614
A Distributed Underwater Structured-Light System: Refraction Compensation, Global Calibration, and Nuclear Metrology
Nuclear fuel assemblies are core reactor components whose geometric integrity is vital for thermal-hydraulic safety and control-rod insertion. This paper presents a high-precision underwater 3-D measurement system for full-scale deformation monitoring of fuel assemblies using a distributed network of non-overlapping binocular structured-light sensors. A virtual-image-plane-based global extrinsic calibration framework is developed to unify all units into a common coordinate system. To eliminate underwater imaging errors, a physical mitigate asymmetric refractive deviations caused by interface tilts, an innovative refraction-equivalent distortion compensation model and a thin-prism-based calibration strategy are introduced is proposed, which mathematically maps the complex multi-media physical tilt into an internal thin-prism distortion . The system’s performance has been validated using a full-scale simulated fuel assembly. Results demonstrate a maximum measurement deviation of less than 0.48 mm over a large measurement envelope (4050 × 1200 × 1200 mm), with bending errors within 0.44mm and twisting errors below 0.06◦ underwater. This system provides a robust, non-contact solution for the structural health monitoring of nuclear fuel, offering significant practical value for nuclear plant maintenance.
- 9 February 2026
- Published by Elsevier in Measurement
- Vol. 269
UW-MBSM: Multi-binocular vision system with non-overlapping fields of view-based underwater kinematic state measurement framework
- 9 February 2026
- Published by Elsevier in Measurement
- Vol. 269
UW-MBSM: Multi-binocular vision system with non-overlapping fields of view-based underwater kinematic state measurement framework
- 21 September 2025
- Published by Elsevier in Ocean Engineering
- Vol. 342
A CPP-ESO controller for robust multi-USV formation under complex environments and communication constraints
- 21 September 2025
- Published by Elsevier in Ocean Engineering
- Vol. 342
A CPP-ESO controller for robust multi-USV formation under complex environments and communication constraints
- 23 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (15) , 28192-28201
Miniaturized Respiratory Monitoring System With Subsecond Response Enabled by Microresonator Sensing Technology
Existing respiratory sensing techniques face challenges including low sensitivity, slow response, and bulky size, which limit their capability of recognizing abnormal breathing patterns. In this work, a miniaturized and portable respiratory monitoring system featuring high sensitivity and subsecond response speed is proposed based on a capacitive micromachined ultrasonic transducer (CMUT). The CMUT micro-resonator with a 520 nm-thick resonant nitride membrane is designed and implemented by the nitride-to-oxide wafer bonding process. Without any coatings for functionalization, the ultra-thin membrane allows the device to identify the loaded mass of exhaled water molecules at the fg level. Based on the modified Butterworth-Van Dyke equivalent circuit model, a compact signal processing unit is developed to stably track the CMUT’s resonance frequency in real-time with a high signal to noise ratio of 47.96 dB. The experimental results demonstrate that the device is able to distinguish various respiratory rates and patterns, including abnormal rates of up to 120 BPM. Investigation into the sensing mechanism confirms that the frequency response of the device is triggered by local humidity changes rather than variations in pressure or temperature.
- 23 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (15) , 28192-28201
Miniaturized Respiratory Monitoring System With Subsecond Response Enabled by Microresonator Sensing Technology
Existing respiratory sensing techniques face challenges including low sensitivity, slow response, and bulky size, which limit their capability of recognizing abnormal breathing patterns. In this work, a miniaturized and portable respiratory monitoring system featuring high sensitivity and subsecond response speed is proposed based on a capacitive micromachined ultrasonic transducer (CMUT). The CMUT micro-resonator with a 520 nm-thick resonant nitride membrane is designed and implemented by the nitride-to-oxide wafer bonding process. Without any coatings for functionalization, the ultra-thin membrane allows the device to identify the loaded mass of exhaled water molecules at the fg level. Based on the modified Butterworth-Van Dyke equivalent circuit model, a compact signal processing unit is developed to stably track the CMUT’s resonance frequency in real-time with a high signal to noise ratio of 47.96 dB. The experimental results demonstrate that the device is able to distinguish various respiratory rates and patterns, including abnormal rates of up to 120 BPM. Investigation into the sensing mechanism confirms that the frequency response of the device is triggered by local humidity changes rather than variations in pressure or temperature.
- 1 March 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (3)
A wireless sensor for nanosecond transient electric field measurement based on asymptotic conical antenna and high-speed data acquisition technology
The transient electromagnetic field generated by the operation of high-voltage switches in substations can cause electromagnetic interference to the communication and control electronic equipment in the substation. On the other hand, it can also reflect the working status of the high-voltage switch itself. Therefore, it is necessary to measure and study it. However, the laying of optical fibers and cables is not allowed in the substation. So, a wireless E-field sensor is developed in this paper for measuring the switching E-field pulse in substations. A monopole asymptotic conical antenna is designed as the transient E-field receiving antenna, which has better low-frequency response performance and higher sensitivity than ordinary electrically small antennas. The developed wireless sensor can perform analog-to-digital conversion on the signal received by the antenna at a sampling rate of 2 Gsps and then transmit the digitized switching E-field pulse signal to the host computer through 5G communication technology. The calibration results show that the wireless sensor has a measurement range of 0.1–10 kV/m and a measurement bandwidth of 180 Hz to 350 MHz. Moreover, the measurement range can be adjusted by adjusting the size of the antenna and the circuit parameters of the antenna matching circuit. In addition, based on the developed wireless sensor, the switching E-field pulse in a 330 kV substation is measured, and its time domain and frequency domain waveform characteristics are analyzed and summarized.
- 1 March 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (3)
A wireless sensor for nanosecond transient electric field measurement based on asymptotic conical antenna and high-speed data acquisition technology
The transient electromagnetic field generated by the operation of high-voltage switches in substations can cause electromagnetic interference to the communication and control electronic equipment in the substation. On the other hand, it can also reflect the working status of the high-voltage switch itself. Therefore, it is necessary to measure and study it. However, the laying of optical fibers and cables is not allowed in the substation. So, a wireless E-field sensor is developed in this paper for measuring the switching E-field pulse in substations. A monopole asymptotic conical antenna is designed as the transient E-field receiving antenna, which has better low-frequency response performance and higher sensitivity than ordinary electrically small antennas. The developed wireless sensor can perform analog-to-digital conversion on the signal received by the antenna at a sampling rate of 2 Gsps and then transmit the digitized switching E-field pulse signal to the host computer through 5G communication technology. The calibration results show that the wireless sensor has a measurement range of 0.1–10 kV/m and a measurement bandwidth of 180 Hz to 350 MHz. Moreover, the measurement range can be adjusted by adjusting the size of the antenna and the circuit parameters of the antenna matching circuit. In addition, based on the developed wireless sensor, the switching E-field pulse in a 330 kV substation is measured, and its time domain and frequency domain waveform characteristics are analyzed and summarized.
- 24 September 2024
- Published by Elsevier in Pattern Recognition
- Vol. 158
Self-supervised fusion network for RGB-D interest point detection and description
- 24 September 2024
- Published by Elsevier in Pattern Recognition
- Vol. 158
Self-supervised fusion network for RGB-D interest point detection and description
- Open Access
- 30 September 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (10) , 1651
Comparative Study of Gravimetric Humidity Sensor Platforms Based on CMUT and QCM
Humidity sensors with comprehensive performance are of great interest for industrial and environmental applications. Most sensors, however, have to compromise on at least one characteristic such as sensitivity, response speed, and linearity. This paper reports a gravimetric humidity sensor based on a capacitive micromachined ultrasonic transducer (CMUT) with exceptional all-around performance, and presents a side-by-side comparative investigation of two types of gravimetric humidity sensors for a better understanding of their characteristics and sensing mechanisms. For these purposes, a circular CMUT and a quartz crystal microbalance (QCM) with a resonance frequency of 10 MHz were designed and fabricated. Poly(vinyl alcohol) (PVA) was employed as the humidity sensing layer for its hydrophilicity and ease of film formation. The electrical properties of the sensors, including the electrical input impedances and quality factors, were characterized by a vector network analyzer. The relative humidity (RH) sensing performance of the sensors was evaluated and compared from RH levels of 11% to 97%. Both sensors exhibited good repeatability and low hysteresis. The unique microscale resonant structure of the CMUT humidity sensor contributed to a high sensitivity of 2.01 kHz/%RH, short response and recovery times of 8 s and 3 s, respectively, and excellent linearity (R2 = 0.973), which were far superior to their QCM counterparts. The underlying mechanism was revealed and discussed.
- 30 September 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (10) , 1651
Open AccessComparative Study of Gravimetric Humidity Sensor Platforms Based on CMUT and QCM
Humidity sensors with comprehensive performance are of great interest for industrial and environmental applications. Most sensors, however, have to compromise on at least one characteristic such as sensitivity, response speed, and linearity. This paper reports a gravimetric humidity sensor based on a capacitive micromachined ultrasonic transducer (CMUT) with exceptional all-around performance, and presents a side-by-side comparative investigation of two types of gravimetric humidity sensors for a better understanding of their characteristics and sensing mechanisms. For these purposes, a circular CMUT and a quartz crystal microbalance (QCM) with a resonance frequency of 10 MHz were designed and fabricated. Poly(vinyl alcohol) (PVA) was employed as the humidity sensing layer for its hydrophilicity and ease of film formation. The electrical properties of the sensors, including the electrical input impedances and quality factors, were characterized by a vector network analyzer. The relative humidity (RH) sensing performance of the sensors was evaluated and compared from RH levels of 11% to 97%. Both sensors exhibited good repeatability and low hysteresis. The unique microscale resonant structure of the CMUT humidity sensor contributed to a high sensitivity of 2.01 kHz/%RH, short response and recovery times of 8 s and 3 s, respectively, and excellent linearity (R2 = 0.973), which were far superior to their QCM counterparts. The underlying mechanism was revealed and discussed.