Paloma Malagón
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Paloma Malagón has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
Jordi Vilà
Department of Plastic Surgery, Hospital Germans Trias i Pujol, Universitat Autonoma de Barcelona, Barcelona, Spain
5 shared publicationsCarmen Higueras
Hospital Universitari Germans Trias i Pujol, Barcelona, Spain
4 shared publicationsDavid Priego
Department of Plastic Surgery, Hospital Germans Trias i Pujol, Barcelona, Spain
4 shared publicationsCristian Carrasco
Hospital Universitari Germans Trias i Pujol, Barcelona, Spain
3 shared publications- Cristian Carrasco López
Department of Plastic Surgery, Hospital Germans Trias i Pujol, Universitat Autònoma de Barcelona, 08916 Barcelona, Spain
3 shared publications - Maria Del Rio
Department of Plastic, Reconstructive and Aesthetic Surgery, Germans Trias i Pujol University Hospital, Barcelona, Spain
3 shared publications
Latest Publications
- 4 September 2026
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 122, 169-177
Quantitative ultrasound skin thickness measurement for assessment of lower-limb lymphedema
- 4 September 2026
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 122, 169-177
Quantitative ultrasound skin thickness measurement for assessment of lower-limb lymphedema
- Open Access
- 12 June 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (12) , 4574
Open-Window Thoracostomy Closure Using a Free Musculocutaneous Flap, Fascia Patch Graft, and Postoperative Compression Guided by Near-Infrared Spectroscopy: A Case Report
Bronchopleural fistula is a rare but severe complication of lung resection, associated with significant morbidity and mortality, especially when an open-window thoracostomy is required. The clinical and surgical management is complex and becomes even more challenging in the presence of underlying conditions such as recurrent infections or malignancy. Postoperative management is equally demanding, as local compression may help prevent fistula recurrence but can compromise flap perfusion. A 65-year-old male with a history of right upper lobectomy and subsequent sublobar resection for lung adenocarcinoma presented with an 8 × 4 cm open-window thoracostomy complicated by chronic bronchopleural fistula and empyema. Extensive fibrosis of the surrounding tissues, including the ipsilateral latissimus dorsi muscle, limited the available reconstructive locoregional options. Reconstruction was performed using primary fistula closure reinforced with a contralateral free latissimus dorsi musculocutaneous flap and a fascia patch graft secured with cyanoacrylate-based bioadhesive. Postoperatively, continuous near-infrared spectroscopy monitoring enabled safe application of compressive bandage while minimizing the risk of flap perfusion compromise. Complete fistula closure was achieved. Apart from a surgical site abscess requiring debridement on postoperative day 7, no further complications occurred. At the 2-year follow-up, the patient remains free of fistula recurrence, wound dehiscence, or oncological relapse. We describe a novel approach for open-window thoracostomy closure combining a free musculocutaneous flap with a fascia patch graft reinforced by bioadhesive, together with postoperative perfusion monitoring using near-infrared spectroscopy. This strategy may help address both the reconstructive and postoperative challenges associated with complex bronchopleural fistulas.
- 12 June 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (12) , 4574
Open AccessOpen-Window Thoracostomy Closure Using a Free Musculocutaneous Flap, Fascia Patch Graft, and Postoperative Compression Guided by Near-Infrared Spectroscopy: A Case Report
Bronchopleural fistula is a rare but severe complication of lung resection, associated with significant morbidity and mortality, especially when an open-window thoracostomy is required. The clinical and surgical management is complex and becomes even more challenging in the presence of underlying conditions such as recurrent infections or malignancy. Postoperative management is equally demanding, as local compression may help prevent fistula recurrence but can compromise flap perfusion. A 65-year-old male with a history of right upper lobectomy and subsequent sublobar resection for lung adenocarcinoma presented with an 8 × 4 cm open-window thoracostomy complicated by chronic bronchopleural fistula and empyema. Extensive fibrosis of the surrounding tissues, including the ipsilateral latissimus dorsi muscle, limited the available reconstructive locoregional options. Reconstruction was performed using primary fistula closure reinforced with a contralateral free latissimus dorsi musculocutaneous flap and a fascia patch graft secured with cyanoacrylate-based bioadhesive. Postoperatively, continuous near-infrared spectroscopy monitoring enabled safe application of compressive bandage while minimizing the risk of flap perfusion compromise. Complete fistula closure was achieved. Apart from a surgical site abscess requiring debridement on postoperative day 7, no further complications occurred. At the 2-year follow-up, the patient remains free of fistula recurrence, wound dehiscence, or oncological relapse. We describe a novel approach for open-window thoracostomy closure combining a free musculocutaneous flap with a fascia patch graft reinforced by bioadhesive, together with postoperative perfusion monitoring using near-infrared spectroscopy. This strategy may help address both the reconstructive and postoperative challenges associated with complex bronchopleural fistulas.
- Open Access
- 29 April 2026
- Published by Georg Thieme Verlag KG in Archives of Plastic Surgery
- Vol. 53 (04) , 352-360
The Use of Dynamic Neck Lymphaticovenous Anastomosis in the Adjunctive Treatment of Alzheimer's Disease: A Retrospective Case Series
Lymphovenous anastomosis (LVA) has recently emerged as a potential method for the symptomatic management of Alzheimer's disease (AD). Building on this, we conceptualize the “dynamic neck lymphovenous anastomosis” (DN-LVA) to illustrate the versatility of our technique. DN-LVA utilizes a vein graft that traverses through the sternocleidomastoid muscle to facilitate the drainage of lymphatic fluid from the deep cervical lymphatic vessels to the external jugular vein. This study presents a retrospective analysis of patients who underwent DN-LVA between November 2024 and January 2025. The clinical outcome was evaluated through positron emission tomography/computed tomography (PET/CT) imaging and cognitive assessment tools, which included Mini-Mental State Examination (MMSE), Montreal Cognitive Assessment (MoCA), Neuropsychiatric Inventory (NPI), and Clinical Dementia Rating (CDR). The vein graft was harvested from the lower limb. Five subjects were recruited into this study. Postoperative PET/CT scans revealed up to a 6.9% increase in glucose metabolism in patient 3, a decrease of 12.3% in amyloid deposits, and a 4.7% reduction in tau deposits in patient 5 and patient 4, respectively. Clinically, MMSE and MoCA scores were improved by 1.6 and 1.4, respectively. NPI scores decreased by 5.8 across five overall, and the CDR remained unchanged in all subjects. All grafts demonstrated vessel patency, and no postoperative complications were observed. DN-LVA appears to be a safe, minimally invasive procedure with potential cognitive and metabolic benefits in AD. Further studies with larger cohorts and longer follow-up are warranted to confirm these preliminary findings.
- 29 April 2026
- Published by Georg Thieme Verlag KG in Archives of Plastic Surgery
- Vol. 53 (04) , 352-360
Open AccessThe Use of Dynamic Neck Lymphaticovenous Anastomosis in the Adjunctive Treatment of Alzheimer's Disease: A Retrospective Case Series
Lymphovenous anastomosis (LVA) has recently emerged as a potential method for the symptomatic management of Alzheimer's disease (AD). Building on this, we conceptualize the “dynamic neck lymphovenous anastomosis” (DN-LVA) to illustrate the versatility of our technique. DN-LVA utilizes a vein graft that traverses through the sternocleidomastoid muscle to facilitate the drainage of lymphatic fluid from the deep cervical lymphatic vessels to the external jugular vein. This study presents a retrospective analysis of patients who underwent DN-LVA between November 2024 and January 2025. The clinical outcome was evaluated through positron emission tomography/computed tomography (PET/CT) imaging and cognitive assessment tools, which included Mini-Mental State Examination (MMSE), Montreal Cognitive Assessment (MoCA), Neuropsychiatric Inventory (NPI), and Clinical Dementia Rating (CDR). The vein graft was harvested from the lower limb. Five subjects were recruited into this study. Postoperative PET/CT scans revealed up to a 6.9% increase in glucose metabolism in patient 3, a decrease of 12.3% in amyloid deposits, and a 4.7% reduction in tau deposits in patient 5 and patient 4, respectively. Clinically, MMSE and MoCA scores were improved by 1.6 and 1.4, respectively. NPI scores decreased by 5.8 across five overall, and the CDR remained unchanged in all subjects. All grafts demonstrated vessel patency, and no postoperative complications were observed. DN-LVA appears to be a safe, minimally invasive procedure with potential cognitive and metabolic benefits in AD. Further studies with larger cohorts and longer follow-up are warranted to confirm these preliminary findings.
- 28 November 2025
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 113, 284-286
A practical method for flap perforator selection: Qualitative hemodynamic evaluation with conventional and portable ultrasound
- 28 November 2025
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 113, 284-286
A practical method for flap perforator selection: Qualitative hemodynamic evaluation with conventional and portable ultrasound
- 7 May 2025
- Published by Wolters Kluwer Health in Annals of Plastic Surgery
- Vol. 95 (2) , 163-169
Practical Lymphatic Ultrasound for Supermicrosurgical Lymphaticovenous Anastomosis
Background: Ultrasound (US) has many advantages and is useful for mapping lymph vessels and veins for lymphovenous anastomosis (LVA) and improving their outcomes. However, it is operator-dependent and required some experience. Our aim was to describe how to perform preoperative mapping of LVA using high-frequency US (HFUS) in B mode. Methods: Experiences about preoperative planning of LVA surgeries in patients with upper and lower limb lymphedema using HFUS were the basis of our guide. In addition, data of women with secondary lower limb lymphedema who undergone LVA was analyzed. US examination was performed on the previous day of surgery for mapping lymph vessels and veins using a linear transducer of 18 MHz and B mode. Results: A standardized method to perform step by step the preoperative planning of LVA using HFUS was described. A total of 349 incisions performed in 97 lower limbs were analyzed. The overall success rate for identifying lymph vessels was 99.7%. Mean diameters of lymph vessels and veins were 0.65 mm and 0.81 mm, respectively. Skin incision length was 1.97 cm (range, 1.2–3.8 cm). Surgical time for each LVA was 21.7 minutes (range, 13–47 min). There were a reduction of limb volume index (281.2 vs 267.6, P = 0.002) and an improvement in the quality of life of patients (48.3 vs 21.9, P < 0.001). Conclusions: A standardized method can be followed to effectively perform the preoperative mapping of LVA using HFUS to reduce the limb volume and improve the quality of life of patients with lymphedema.
- 7 May 2025
- Published by Wolters Kluwer Health in Annals of Plastic Surgery
- Vol. 95 (2) , 163-169
Practical Lymphatic Ultrasound for Supermicrosurgical Lymphaticovenous Anastomosis
Background: Ultrasound (US) has many advantages and is useful for mapping lymph vessels and veins for lymphovenous anastomosis (LVA) and improving their outcomes. However, it is operator-dependent and required some experience. Our aim was to describe how to perform preoperative mapping of LVA using high-frequency US (HFUS) in B mode. Methods: Experiences about preoperative planning of LVA surgeries in patients with upper and lower limb lymphedema using HFUS were the basis of our guide. In addition, data of women with secondary lower limb lymphedema who undergone LVA was analyzed. US examination was performed on the previous day of surgery for mapping lymph vessels and veins using a linear transducer of 18 MHz and B mode. Results: A standardized method to perform step by step the preoperative planning of LVA using HFUS was described. A total of 349 incisions performed in 97 lower limbs were analyzed. The overall success rate for identifying lymph vessels was 99.7%. Mean diameters of lymph vessels and veins were 0.65 mm and 0.81 mm, respectively. Skin incision length was 1.97 cm (range, 1.2–3.8 cm). Surgical time for each LVA was 21.7 minutes (range, 13–47 min). There were a reduction of limb volume index (281.2 vs 267.6, P = 0.002) and an improvement in the quality of life of patients (48.3 vs 21.9, P < 0.001). Conclusions: A standardized method can be followed to effectively perform the preoperative mapping of LVA using HFUS to reduce the limb volume and improve the quality of life of patients with lymphedema.
- 24 February 2025
- Published by Wiley in Microsurgery
- Vol. 45 (2) , e70041
Conventional High‐Frequency Ultrasound for Preoperative Planning of Superficial Circumflex Iliac Artery Perforator ( SCIP ) Pure Skin Perforator ( PSP ) Flaps
Background: Pure skin perforator (PSP) flaps had shown their reliability and usefulness for the reconstruction of thin soft‐tissue defects. However, accurate localization of PSP is required for safe and fast flap elevation. This study aimed to evaluate the usefulness of conventional high‐frequency ultrasound (US) for PSP flap elevation. Methods: Patients who underwent reconstruction using PSP flap based on the superficial branch of the superficial circumflex iliac artery (SCIA) were retrospectively included and divided into two groups according to the use of preoperative US mapping of SCIA PSPs; a portable US device with an 18 MHz probe was used to localize the PSP in a US group, whereas US was not used in a control group. Intraoperative findings and postoperative results were compared between the groups. Results: Twenty‐seven patients were included: 12 in the US group and 15 in the control group. There were no statistically significant differences in patient characteristics and postoperative results between the groups; both groups showed flap survival without major complications in all cases. Flap thickness ranged from 1.0 to 2.5 mm (average, 1.87 mm). Time for flap harvest was significantly shorter in the US group than in the control group (18.9 ± 4.5 vs. 50.5 ± 20.8 min, p < 0.001). Conclusions: Preoperative mapping of PSP using high‐frequency US allowed reducing the surgical time for harvesting PSP flaps.
- 24 February 2025
- Published by Wiley in Microsurgery
- Vol. 45 (2) , e70041
Conventional High‐Frequency Ultrasound for Preoperative Planning of Superficial Circumflex Iliac Artery Perforator ( SCIP ) Pure Skin Perforator ( PSP ) Flaps
Background: Pure skin perforator (PSP) flaps had shown their reliability and usefulness for the reconstruction of thin soft‐tissue defects. However, accurate localization of PSP is required for safe and fast flap elevation. This study aimed to evaluate the usefulness of conventional high‐frequency ultrasound (US) for PSP flap elevation. Methods: Patients who underwent reconstruction using PSP flap based on the superficial branch of the superficial circumflex iliac artery (SCIA) were retrospectively included and divided into two groups according to the use of preoperative US mapping of SCIA PSPs; a portable US device with an 18 MHz probe was used to localize the PSP in a US group, whereas US was not used in a control group. Intraoperative findings and postoperative results were compared between the groups. Results: Twenty‐seven patients were included: 12 in the US group and 15 in the control group. There were no statistically significant differences in patient characteristics and postoperative results between the groups; both groups showed flap survival without major complications in all cases. Flap thickness ranged from 1.0 to 2.5 mm (average, 1.87 mm). Time for flap harvest was significantly shorter in the US group than in the control group (18.9 ± 4.5 vs. 50.5 ± 20.8 min, p < 0.001). Conclusions: Preoperative mapping of PSP using high‐frequency US allowed reducing the surgical time for harvesting PSP flaps.
- 14 November 2024
- Published by Springer Nature in European Journal of Plastic Surgery
- Vol. 47 (1) , 1-9
Analytical assessment of the learning curve for preoperative planning of lymphovenous anastomosis using ultrahigh frequency ultrasound
- 14 November 2024
- Published by Springer Nature in European Journal of Plastic Surgery
- Vol. 47 (1) , 1-9
Analytical assessment of the learning curve for preoperative planning of lymphovenous anastomosis using ultrahigh frequency ultrasound
- 21 April 2023
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 83, 334-342
A new protocol for improving immediate monitoring of skin-island free flap with near-infrared spectroscopy and ultrasound
- 21 April 2023
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 83, 334-342
A new protocol for improving immediate monitoring of skin-island free flap with near-infrared spectroscopy and ultrasound
- 28 June 2022
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 75 (8) , 2831-2870
Improving the learning process of ultrasound in plastic surgery: How easy is to read ultrasound images?
- 28 June 2022
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 75 (8) , 2831-2870
Improving the learning process of ultrasound in plastic surgery: How easy is to read ultrasound images?