Koki Ogura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Koki Ogura has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Mutsuo Nakaoka
University of Malaya
3 shared publications- Mohan Lal Kolhe
Faculty of Engineering and Science, University of Agder, 4604 Kristiansand, Norway
2 shared publications - Siraporn Sakphrom
School of Engineering and Technology, Walailak University, Nakhon Si Thammarat 80160, Thailand
2 shared publications - Srawouth Chandhaket
School of Engineering and Technology, Walailak University, Nakhon Si Thammarat 80160, Thailand
2 shared publications - Charernkiat Pochaiya
Department of Electrical Engineering, School of Engineering and Technology, Walailak University, Nakhon Si Thammarat 80161, Thailand
1 shared publication Haruo Terai
Matsushita Electric Industrial Co., Ltd., Japan
1 shared publication
Latest Publications
- Open Access
Implementing a Low-Cost Non-Destructive Microwave Sensor to Monitor the Real-Time Moisture Content of Rubber Wood in Industrial Dehydration Processes
This study aims to present a low-cost, non-destructive microwave sensor implementation to monitor the real-time moisture content of rubber wood in industrial dehydration processes. The proposed sensor is based on the free-space measurement technique with magnitudes S11 and S21 only. The novelties of this study consist of the natural frequency determination of rubber wood and the design of a sensor system using devices available on the market with reasonable cost performance. The natural frequency was determined using a simulation and was equal to 1.25 GHz. It specified the sensor system design and device selection. The designed system was initially verified by measuring the moisture content of rubber wood in the laboratory. The measured S11 and S21 voltages correlating with moisture content percentages were obtained and programmed. The system was then installed to monitor the moisture content of rubber wood in the dehydration process. The measured results deviated from those obtained from a standard method in the range of 7.67–15.38%. The error compensation was analyzed to improve the measured results that provided the deviated moisture content in the range of 3.58–5.21%. It can be inferred that the proposed sensor system has the capability to be implemented in industrial dehydration processes.
Open AccessImplementing a Low-Cost Non-Destructive Microwave Sensor to Monitor the Real-Time Moisture Content of Rubber Wood in Industrial Dehydration Processes
This study aims to present a low-cost, non-destructive microwave sensor implementation to monitor the real-time moisture content of rubber wood in industrial dehydration processes. The proposed sensor is based on the free-space measurement technique with magnitudes S11 and S21 only. The novelties of this study consist of the natural frequency determination of rubber wood and the design of a sensor system using devices available on the market with reasonable cost performance. The natural frequency was determined using a simulation and was equal to 1.25 GHz. It specified the sensor system design and device selection. The designed system was initially verified by measuring the moisture content of rubber wood in the laboratory. The measured S11 and S21 voltages correlating with moisture content percentages were obtained and programmed. The system was then installed to monitor the moisture content of rubber wood in the dehydration process. The measured results deviated from those obtained from a standard method in the range of 7.67–15.38%. The error compensation was analyzed to improve the measured results that provided the deviated moisture content in the range of 3.58–5.21%. It can be inferred that the proposed sensor system has the capability to be implemented in industrial dehydration processes.
- Open Access
- 21 January 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (3) , 1122
Simple Lossless Inductive Snubbers-Assisted Series Load Resonant Inverter Operating under ZCS-PDM Scheme for High-Frequency Induction Heating Fixed Roller
This paper presents a high-frequency pulse-density-modulated (PDM) soft-switching series load resonant inverter for use in induction heating (IH) fixed roller applications, which is used in copy and printing machines. The proposed simple high-frequency resonant inverter uses an asymmetrical pulse pattern PDM control scheme to achieve complete zero-current soft-switching commutations over a wide output range of input power regulation. Additionally, when the printer toner requires operation in very light load conditions, this causes difficulty in achieving zero-voltage or zero-current soft-switching operations in the IH high-frequency resonant inverters with pulse frequency modulation or pulse width modulation control schemes. The proposed resonant inverter demonstrates the capability to accomplish highly efficient power conversions. In this work, a fixed roller for printing machines is developed for doing experiments to verify the efficiency of the proposed circuit topology and its PDM control schemes. The inverter’s steady-state and transient operating principles are analyzed based on the proposed control strategy at a high-frequency PDM. Operating conditions such as power loss analysis, power conversion efficiency and temperature rise characteristics of the proposed inverter are presented and analyzed through experimental results. Finally, from a practical viewpoint, a comparative study of a conventional halogen lamp heater and the proposed IH fixed roller is deliberated.
- 21 January 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (3) , 1122
Open AccessSimple Lossless Inductive Snubbers-Assisted Series Load Resonant Inverter Operating under ZCS-PDM Scheme for High-Frequency Induction Heating Fixed Roller
This paper presents a high-frequency pulse-density-modulated (PDM) soft-switching series load resonant inverter for use in induction heating (IH) fixed roller applications, which is used in copy and printing machines. The proposed simple high-frequency resonant inverter uses an asymmetrical pulse pattern PDM control scheme to achieve complete zero-current soft-switching commutations over a wide output range of input power regulation. Additionally, when the printer toner requires operation in very light load conditions, this causes difficulty in achieving zero-voltage or zero-current soft-switching operations in the IH high-frequency resonant inverters with pulse frequency modulation or pulse width modulation control schemes. The proposed resonant inverter demonstrates the capability to accomplish highly efficient power conversions. In this work, a fixed roller for printing machines is developed for doing experiments to verify the efficiency of the proposed circuit topology and its PDM control schemes. The inverter’s steady-state and transient operating principles are analyzed based on the proposed control strategy at a high-frequency PDM. Operating conditions such as power loss analysis, power conversion efficiency and temperature rise characteristics of the proposed inverter are presented and analyzed through experimental results. Finally, from a practical viewpoint, a comparative study of a conventional halogen lamp heater and the proposed IH fixed roller is deliberated.
- Open Access
- 17 October 2018
- Published by Springer Nature in Journal of Modern Power Systems and Clean Energy
- Vol. 6 (6) , 1338-1343
Partial sine wave tracking dual mode control topology for a single-phase transformerless photovoltaic system
- 17 October 2018
- Published by Springer Nature in Journal of Modern Power Systems and Clean Energy
- Vol. 6 (6) , 1338-1343
Open AccessPartial sine wave tracking dual mode control topology for a single-phase transformerless photovoltaic system
- Open Access
- 29 May 2003
- Published by Wiley in Electrical Engineering in Japan
- Vol. 144 (3) , 58-68
Comparative performance evaluations of IGBTs and MCT incorporated into voltage-source-type single-ended quasi-resonant zero-voltage soft switching inverter
- 29 May 2003
- Published by Wiley in Electrical Engineering in Japan
- Vol. 144 (3) , 58-68
Open AccessComparative performance evaluations of IGBTs and MCT incorporated into voltage-source-type single-ended quasi-resonant zero-voltage soft switching inverter