Maciej Dobrzański
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Maciej Dobrzański has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Robert Cichowicz
Faculty of Civil Engineering, Architecture and Environmental Engineering, Lodz University of Technology, Al. Politechniki 6, 90-924 Lodz, Poland
10 shared publications Andrzej Jodłowski
Lodz University of Technology, Institute of Environmental Engineering and Building Installations, 90-924Lodz, Politechniki Ave 6, Poland
1 shared publication- Damian Piotr Muniak
Cracow University of Technology
1 shared publication Edyta Galoch
1 shared publication- Izabela Sówka
Wroclaw University of Science and Technology Department of Environment Protection Engineering, Faculty of Environmental Engineering
1 shared publication - Jarosław Müller
Faculty of Environmental Engineering and Energy, Cracow University of Technology, Warszawska 24, 31-155 Cracow, Poland
1 shared publication
Latest Publications
- 20 January 2026
- Published by Polskie Zrzeszenie Inżynierów i Techników Sanitarnych in Ciepłownictwo Ogrzewnictwo Wentylacja
- Vol. 57 (1) , 28
Zmiany stężenia zanieczyszczeń pyłowych w budynku użyteczności publiczne z wentylacją mechaniczną
W artykule przedstawiono wyniki badań jakości powietrza zewnętrznego i wewnętrznego w dwóch salach placówki wychowania przedszkolnego wyposażonego w wentylację mechaniczną nawiewno-wywiewną. Pomiary realizowano w 2023 roku, wykorzystując mobilne czujniki pyłów zawieszonych PM10 i PM2.5 oraz wilgotności i temperatury powietrza, które rozmieszczono wewnątrz oraz na zewnątrz pomieszczeń. Analiza zebranych danych pozwoliła na ocenę stanu powietrza wewnętrznego w pomieszczeniu wykorzystywanym w celach edukacyjnych w odniesieniu do pomieszczenia nieużytkowanego o zbliżonych parametrach budowlanych. Ponadto określono efektywność ograniczania przedostawania się zewnętrznych zanieczyszczeń pyłowych do wnętrza budynku przez wentylację mechaniczną. Wykazano, że stężenie pyłów w pomieszczeniu użytkowanym było średnio o 49 % wyższe niż w pomieszczeniu nieużytkowanym. Średnia efektywność zatrzymywania zanieczyszczeń pyłowych PM10 i PM2.5 przez wentylację mechaniczną wynosiła odpowiednio 52 i 37% względem stężenia na zewnątrz. Stwierdzono nieliczne momenty, w których stężenie wewnątrz pomieszczeń byłoby wyższe niż na zewnątrz co świadczy o sprawnej wymianie powietrza zużytego. Ocena wykazała, że jakość powietrza w pomieszczeniach była dobra lub bardzo dobra, a użytkownicy mogą z nich korzystać bezpiecznie. Jednakże wprowadzenie czujników stężenia pyłów zawieszonych sterujących pracą centrali wentylacyjnej mogłoby zniwelować pojawiające się chwilowe zwiększone stężenia pyłów.
- 20 January 2026
- Published by Polskie Zrzeszenie Inżynierów i Techników Sanitarnych in Ciepłownictwo Ogrzewnictwo Wentylacja
- Vol. 57 (1) , 28
Zmiany stężenia zanieczyszczeń pyłowych w budynku użyteczności publiczne z wentylacją mechaniczną
W artykule przedstawiono wyniki badań jakości powietrza zewnętrznego i wewnętrznego w dwóch salach placówki wychowania przedszkolnego wyposażonego w wentylację mechaniczną nawiewno-wywiewną. Pomiary realizowano w 2023 roku, wykorzystując mobilne czujniki pyłów zawieszonych PM10 i PM2.5 oraz wilgotności i temperatury powietrza, które rozmieszczono wewnątrz oraz na zewnątrz pomieszczeń. Analiza zebranych danych pozwoliła na ocenę stanu powietrza wewnętrznego w pomieszczeniu wykorzystywanym w celach edukacyjnych w odniesieniu do pomieszczenia nieużytkowanego o zbliżonych parametrach budowlanych. Ponadto określono efektywność ograniczania przedostawania się zewnętrznych zanieczyszczeń pyłowych do wnętrza budynku przez wentylację mechaniczną. Wykazano, że stężenie pyłów w pomieszczeniu użytkowanym było średnio o 49 % wyższe niż w pomieszczeniu nieużytkowanym. Średnia efektywność zatrzymywania zanieczyszczeń pyłowych PM10 i PM2.5 przez wentylację mechaniczną wynosiła odpowiednio 52 i 37% względem stężenia na zewnątrz. Stwierdzono nieliczne momenty, w których stężenie wewnątrz pomieszczeń byłoby wyższe niż na zewnątrz co świadczy o sprawnej wymianie powietrza zużytego. Ocena wykazała, że jakość powietrza w pomieszczeniach była dobra lub bardzo dobra, a użytkownicy mogą z nich korzystać bezpiecznie. Jednakże wprowadzenie czujników stężenia pyłów zawieszonych sterujących pracą centrali wentylacyjnej mogłoby zniwelować pojawiające się chwilowe zwiększone stężenia pyłów.
- 2 May 2025
- Published by Elsevier in Chemosphere
- Vol. 380, 144442
Impact of the size of settlement units, Covid-19 pandemic, and the ongoing war in Ukraine on air quality in Poland
- 2 May 2025
- Published by Elsevier in Chemosphere
- Vol. 380, 144442
Impact of the size of settlement units, Covid-19 pandemic, and the ongoing war in Ukraine on air quality in Poland
- Open Access
- 13 December 2024
- Published by Politechnika Koszalinska in Rocznik Ochrona Środowiska
- Vol. 26, 716-727
Analysis of Ammonia Emissions from Thermal Sludge Treatment Plants
The article presents an analysis of the spatial dispersion of ammonia in the troposphere, emitted from the thermal treatment of sludge from the sewage treatment plant in Łódź. The study aimed to assess the impact of the emitter on the air quality in the nearby single-family housing estate. The results of field measurements of ammonia concentration were compared with computer simulations based on data measured at the emitter. Mobile measuring equipment mounted on a transport platform and an unmanned aerial vehicle was used to conduct field measurements, which were then subjected to analytical processing in ArcGis Pro software. Computer simulation of ammonia dispersion from two 25 m high chimneys was conducted in the OPA03 program. Both field measurements and simulation data showed a negligible impact of the emitter on the ammonia concentration in the air. This is primarily due to the low concentration of emitted ammonia at the chimney outlet and the emitter's location relative to the buildings, considering the dominant wind directions. Field studies have shown that the emission of ammonia in the analyzed area may be to a greater extent caused by the sewage collection station from sewage disposal vehicles and the composting plant, which are located close to the analyzed emitter and the residential area.
- 13 December 2024
- Published by Politechnika Koszalinska in Rocznik Ochrona Środowiska
- Vol. 26, 716-727
Open AccessAnalysis of Ammonia Emissions from Thermal Sludge Treatment Plants
The article presents an analysis of the spatial dispersion of ammonia in the troposphere, emitted from the thermal treatment of sludge from the sewage treatment plant in Łódź. The study aimed to assess the impact of the emitter on the air quality in the nearby single-family housing estate. The results of field measurements of ammonia concentration were compared with computer simulations based on data measured at the emitter. Mobile measuring equipment mounted on a transport platform and an unmanned aerial vehicle was used to conduct field measurements, which were then subjected to analytical processing in ArcGis Pro software. Computer simulation of ammonia dispersion from two 25 m high chimneys was conducted in the OPA03 program. Both field measurements and simulation data showed a negligible impact of the emitter on the ammonia concentration in the air. This is primarily due to the low concentration of emitted ammonia at the chimney outlet and the emitter's location relative to the buildings, considering the dominant wind directions. Field studies have shown that the emission of ammonia in the analyzed area may be to a greater extent caused by the sewage collection station from sewage disposal vehicles and the composting plant, which are located close to the analyzed emitter and the residential area.
- Open Access
Analysis of Air Pollutants for a Small Paintshop by Means of a Mobile Platform and Geostatistical Methods
Air pollution, in terms of particulate matter (PM10, PM2.5, PM1.0) and gaseous pollutants (H2S and VOC), has serious health effects, particularly in cities. The evaluation of outdoor air quality was carried out in the vicinity of a small paintshop operating in the city of Łódź, Poland. The concentrations of pollutants in the vertical profiles (up to 47 m a.g.l.) of ambient air were measured using a mobile platform (unmanned aerial vehicle with measuring equipment) during three measurement campaigns in September 2021. The vertical structure of the pollutant concentrations indicated the occurrence of different types of layers with an almost constant concentration near the land surface, a strong decrease (up to ca. 10–15 m a.g.l.), and significant fluctuations in concentrations to higher levels (above 25 m a.g.l.). Particulate matter concentrations (PM10, PM2.5, PM1.0) did not exceed 39 µg m−3, with stable levels on the surface. The maximum value of particulate matter concentrations (up to 38.5 µg m−3) in the vertical profiles was recorded at ca. 35–40 m a.g.l. The average concentrations of H2S and VOC varied between 0.07 and 0.12 ppm and 0.01 and 0.27 ppm, respectively. The highest H2S concentrations were observed at ca. 18–23 m a.g.l., reaching 0.14 ppm. A rapid increase in VOC concentrations, reaching 0.29 ppm, was measured in vertical profiles from 20 m a.g.l. and up to about 40 m a.g.l. In situ measurement approaches were combined with interpolation methods in the GIS system to investigate the spatial variability of pollution levels from a specified source in the urban atmosphere. Based on the survey results, the kriging interpolation method was well suited for generating spatially distributed pollution maps for individual measurement campaigns.
Open AccessAnalysis of Air Pollutants for a Small Paintshop by Means of a Mobile Platform and Geostatistical Methods
Air pollution, in terms of particulate matter (PM10, PM2.5, PM1.0) and gaseous pollutants (H2S and VOC), has serious health effects, particularly in cities. The evaluation of outdoor air quality was carried out in the vicinity of a small paintshop operating in the city of Łódź, Poland. The concentrations of pollutants in the vertical profiles (up to 47 m a.g.l.) of ambient air were measured using a mobile platform (unmanned aerial vehicle with measuring equipment) during three measurement campaigns in September 2021. The vertical structure of the pollutant concentrations indicated the occurrence of different types of layers with an almost constant concentration near the land surface, a strong decrease (up to ca. 10–15 m a.g.l.), and significant fluctuations in concentrations to higher levels (above 25 m a.g.l.). Particulate matter concentrations (PM10, PM2.5, PM1.0) did not exceed 39 µg m−3, with stable levels on the surface. The maximum value of particulate matter concentrations (up to 38.5 µg m−3) in the vertical profiles was recorded at ca. 35–40 m a.g.l. The average concentrations of H2S and VOC varied between 0.07 and 0.12 ppm and 0.01 and 0.27 ppm, respectively. The highest H2S concentrations were observed at ca. 18–23 m a.g.l., reaching 0.14 ppm. A rapid increase in VOC concentrations, reaching 0.29 ppm, was measured in vertical profiles from 20 m a.g.l. and up to about 40 m a.g.l. In situ measurement approaches were combined with interpolation methods in the GIS system to investigate the spatial variability of pollution levels from a specified source in the urban atmosphere. Based on the survey results, the kriging interpolation method was well suited for generating spatially distributed pollution maps for individual measurement campaigns.
- 30 March 2023
- Published by Elsevier in Science of The Total Environment
- Vol. 878, 163126
Impact of building types and CHP plants on air quality (2019–2021) in central-eastern European monocentric agglomeration
- 30 March 2023
- Published by Elsevier in Science of The Total Environment
- Vol. 878, 163126
Impact of building types and CHP plants on air quality (2019–2021) in central-eastern European monocentric agglomeration
- Open Access
Analysis of Air Pollution around a CHP Plant: Real Measurements vs. Computer Simulations
This study examines the concentrations of air pollution in the vicinity of a combined heat and power plant (CHP) and a communication route, using computer modeling of pollutant dispersion and spatial analysis based on real measurements in the city of Łódź, Poland, Europe. The research takes into account the concentrations of particulate matter (PM10, PM2.5, PM1.0) and gaseous pollutants (SO2 and VOC) in winter and summer. The spatial distribution of pollutants is discussed, including the presence of areas with increased accumulations of pollutants. Because atmospheric air has no natural boundaries, when analyzing any location, not only local sources of pollution, but also background pollution, should be analyzed. A clear difference was observed between the concentrations of pollutants in the summer and winter seasons, with significantly higher concentrations in the winter (heating) period. The impacts of road transport, individual heating systems, and combined heat and power plants were also assessed. Computer calculations confirmed that road transport accounted for the largest share of both PM and SO2 emissions. The CHP plant was responsible for the smallest percentage of dust emissions and was the next largest producer of SO2 emissions. The share of the total emissions from the individual sources were compared with the results of detailed field tests. The numerical analysis of selected pollution sources in combination with the field analysis shows that the identified pollution sources included in the analysis represent only a part of the total observed pollutant concentrations (suggesting that other background sources account for the rest).
Open AccessAnalysis of Air Pollution around a CHP Plant: Real Measurements vs. Computer Simulations
This study examines the concentrations of air pollution in the vicinity of a combined heat and power plant (CHP) and a communication route, using computer modeling of pollutant dispersion and spatial analysis based on real measurements in the city of Łódź, Poland, Europe. The research takes into account the concentrations of particulate matter (PM10, PM2.5, PM1.0) and gaseous pollutants (SO2 and VOC) in winter and summer. The spatial distribution of pollutants is discussed, including the presence of areas with increased accumulations of pollutants. Because atmospheric air has no natural boundaries, when analyzing any location, not only local sources of pollution, but also background pollution, should be analyzed. A clear difference was observed between the concentrations of pollutants in the summer and winter seasons, with significantly higher concentrations in the winter (heating) period. The impacts of road transport, individual heating systems, and combined heat and power plants were also assessed. Computer calculations confirmed that road transport accounted for the largest share of both PM and SO2 emissions. The CHP plant was responsible for the smallest percentage of dust emissions and was the next largest producer of SO2 emissions. The share of the total emissions from the individual sources were compared with the results of detailed field tests. The numerical analysis of selected pollution sources in combination with the field analysis shows that the identified pollution sources included in the analysis represent only a part of the total observed pollutant concentrations (suggesting that other background sources account for the rest).
- Open Access
Modeling Pollutant Emissions: Influence of Two Heat and Power Plants on Urban Air Quality
Large industrial plants, power plants, and combined heat and power plants are popularly believed to be the main sources of point emissions, affecting both local and global air quality. This is because these installations emit significant amounts of pollutants at high altitudes every year. In this study, we investigate the impact of two solid fuel (hard coal)-fired CHP plants located within the urban agglomeration on the air quality of the city of Lodz in Poland (Europe). We used an OPA03 computer software to model the spatial distribution of pollutants. The results show that the annual average concentrations of pollutants were highest at an altitude of 25 m above ground level and decreased at lower measurement heights. The concentrations did not exceed permissible levels, reaching only 4% of national and international regulatory limits. We also made field measurements during the winter heating period, using an unmanned aerial vehicle (UAV) equipped with sensors to map the distributions of dust and gas pollutants in the areas with the highest concentrations of emissions from the two heat and power plants. Overall, the field measurements confirmed that it is not high-altitude emissions that have the greatest impact on local air quality.
Open AccessModeling Pollutant Emissions: Influence of Two Heat and Power Plants on Urban Air Quality
Large industrial plants, power plants, and combined heat and power plants are popularly believed to be the main sources of point emissions, affecting both local and global air quality. This is because these installations emit significant amounts of pollutants at high altitudes every year. In this study, we investigate the impact of two solid fuel (hard coal)-fired CHP plants located within the urban agglomeration on the air quality of the city of Lodz in Poland (Europe). We used an OPA03 computer software to model the spatial distribution of pollutants. The results show that the annual average concentrations of pollutants were highest at an altitude of 25 m above ground level and decreased at lower measurement heights. The concentrations did not exceed permissible levels, reaching only 4% of national and international regulatory limits. We also made field measurements during the winter heating period, using an unmanned aerial vehicle (UAV) equipped with sensors to map the distributions of dust and gas pollutants in the areas with the highest concentrations of emissions from the two heat and power plants. Overall, the field measurements confirmed that it is not high-altitude emissions that have the greatest impact on local air quality.
- Open Access
3D Spatial Analysis of Particulate Matter (PM10, PM2.5 and PM1.0) and Gaseous Pollutants (H2S, SO2 and VOC) in Urban Areas Surrounding a Large Heat and Power Plant
In many regions of the world, the winter period is a time of poor air quality, due primarily to the increased use of individual and district heating systems. As a consequence, the atmospheric air contains increased concentrations of both particulate matter and gaseous pollutants (as a result of “low” emissions at altitudes of up to 40 m and “high” emissions more than 40 m above ground level). In winter, the increased pollution is very often exacerbated by meteorological conditions, including air temperature, pressure, air speed, wind direction, and thermal inversion. Here, we analyze the concentrations of particulate matter (PM10, PM2.5, and PM1.0) and gaseous pollutants (H2S, SO2, and VOC) in the immediate vicinity of a large solid fuel-fired heat and power plant located in an urban agglomeration. Two locations were selected for analysis. The first was close to an air quality measurement station in the center of a multi-family housing estate. The second was the intersection of two main communication routes. To determine the impact of “low” and “high” emissions on air quality, the selected pollutants were measured at heights of between 2 and 50 m using an unmanned aerial vehicle. The results were compared with permissible standards for the concentration of pollutants. Temperature inversion was found to have a strong influence on the level of pollutants at various heights, with higher concentrations of particulate matter registered at altitudes above 40 m. The source of PM, H2S, and SO2 pollutants was confirmed to be “low emission” from local transport, industrial plant areas, and the housing estate comprising detached houses located in the vicinity of the measuring points. “High emission” was found to be responsible for the high concentrations of VOC at altitudes of more than 40 m above the intersection and in the area of the housing estate.
Open Access3D Spatial Analysis of Particulate Matter (PM10, PM2.5 and PM1.0) and Gaseous Pollutants (H2S, SO2 and VOC) in Urban Areas Surrounding a Large Heat and Power Plant
In many regions of the world, the winter period is a time of poor air quality, due primarily to the increased use of individual and district heating systems. As a consequence, the atmospheric air contains increased concentrations of both particulate matter and gaseous pollutants (as a result of “low” emissions at altitudes of up to 40 m and “high” emissions more than 40 m above ground level). In winter, the increased pollution is very often exacerbated by meteorological conditions, including air temperature, pressure, air speed, wind direction, and thermal inversion. Here, we analyze the concentrations of particulate matter (PM10, PM2.5, and PM1.0) and gaseous pollutants (H2S, SO2, and VOC) in the immediate vicinity of a large solid fuel-fired heat and power plant located in an urban agglomeration. Two locations were selected for analysis. The first was close to an air quality measurement station in the center of a multi-family housing estate. The second was the intersection of two main communication routes. To determine the impact of “low” and “high” emissions on air quality, the selected pollutants were measured at heights of between 2 and 50 m using an unmanned aerial vehicle. The results were compared with permissible standards for the concentration of pollutants. Temperature inversion was found to have a strong influence on the level of pollutants at various heights, with higher concentrations of particulate matter registered at altitudes above 40 m. The source of PM, H2S, and SO2 pollutants was confirmed to be “low emission” from local transport, industrial plant areas, and the housing estate comprising detached houses located in the vicinity of the measuring points. “High emission” was found to be responsible for the high concentrations of VOC at altitudes of more than 40 m above the intersection and in the area of the housing estate.
- 5 February 2021
- Published by Cracow University of Technology in Technical Transactions
- p. 1-10
The influence of water price and the number of residents on the economic efficiency of water recovery from grey water
This article presents the results of an analysis of the economic viability of using an installation for the treatment of grey water. Economic indicators in the form of simple payback time (SPBT) and net present value (NPV) were used in the analysis. The use of a dual water supply system should theoretically enable the reduction of the costs of both water supply and sewage disposal, ensuring investment profitability. The article presents the impact of the number of residents as well as the impact of water and sewage on the profitability of using example water-recovery systems. It was found that both factors have a huge impact on the result of the economic analysis. For a small number of residents and at a low price of water supply and sewage disposal, it is not profitable to invest in a water-recovery system. This is due to the high price of purification devices.
- 5 February 2021
- Published by Cracow University of Technology in Technical Transactions
- p. 1-10
The influence of water price and the number of residents on the economic efficiency of water recovery from grey water
This article presents the results of an analysis of the economic viability of using an installation for the treatment of grey water. Economic indicators in the form of simple payback time (SPBT) and net present value (NPV) were used in the analysis. The use of a dual water supply system should theoretically enable the reduction of the costs of both water supply and sewage disposal, ensuring investment profitability. The article presents the impact of the number of residents as well as the impact of water and sewage on the profitability of using example water-recovery systems. It was found that both factors have a huge impact on the result of the economic analysis. For a small number of residents and at a low price of water supply and sewage disposal, it is not profitable to invest in a water-recovery system. This is due to the high price of purification devices.