FKFerdinand Kloos

Ferdinand Kloos

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ferdinand Kloos has a total of 23 co-authors. Here are the top co-authors by number of shared publications:

  • Gerrit Bode

    Department of Orthopedics and Trauma Surgery, Faculty of Medicine, Clinic of Orthopedic Surgery and Traumatology, Freiburg University Hospital, Medical Center-Albert-Ludwigs-University of Freiburg, Freiburg, Germany

    3 shared publications
  • Benjamin Fleischer

    Department of Orthopedic Surgery, Hannover Medical School, Hanover, Germany

    2 shared publications
  • Christoph Becher

    Department of Orthopedic Surgery, Hannover Medical School, Hanover, Germany

    2 shared publications
  • Andreas Fuchs

    Department of Orthopedics and Trauma Surgery, Faculty of Medicine, Clinic of Orthopedic Surgery and Traumatology, Freiburg University Hospital, Medical Center-Albert-Ludwigs-University of Freiburg, Freiburg, Germany

    1 shared publication
  • Andreas Fuchs

    Department of Orthopedic Surgery and Traumatology, Freiburg University Hospital, Albert Ludwigs University Freiburg, Hugstetter Straße 55, 79106 Freiburg, Germany

    1 shared publication
  • Anna-Sophie Brenner

    Department of Orthopedics and Trauma Surgery, Faculty of Medicine, Albert-Ludwigs-University of Freiburg, Freiburg, Germany

    1 shared publication

Latest Publications

  • Open Access

    Discharging the medial knee compartment: comparison of pressure distribution and kinematic shifting after implantation of an extra-capsular absorber system (ATLAS) and open-wedge high tibial osteotomy—a biomechanical in vitro analysis

    by Ferdinand Kloos, Christoph Becher, Benjamin Fleischer, Max Ettinger, Lisa Bode, Hagen Schmal, Andreas Fuchs, Sven Ostermeier, Gerrit Bode

    Purpose: Young and active patients suffering early degenerative changes of the medial compartment with an underlying straight-leg axis do face a therapeutical gap as unloading of the medial compartment cannot be achieved by high tibial osteotomy. Extracapsular absorbing implants were developed to close this existing therapeutical gap. Purpose of the present cadaveric biomechanical study was to compare the unloading effect of the knee joint after implantation of an extra-articular absorber system (ATLAS) in comparison to open-wedge high tibial osteotomy (OW-HTO) under physiological conditions. The hypothesis of the study was that implantation of an extra-capsular absorber results in an unloading effect comparable to the one achievable with OW-HTO. Methods: Eight fresh-frozen cadaveric knees were tested under isokinetic flexion–extension motions and physiological loading using a biomechanical knee simulator. Tibiofemoral area contact and peak contact pressures were measured using pressure-sensitive film in the untreated medial compartment. The tibiofemoral superior–inferior, latero-medial translation and varus/valgus rotation were measured with a 3D tracking system Polaris. Pressures and kinematics changes were measured after native testing, ATLAS System implantation and OW-HTO (5° and 10° correction angles) performed with an angular stable internal fixator (TomoFix). Results: The absorber device decreased the pressure in the medial compartment near full extension moments. Implantation of the ATLAS absorbing system according to the manufacturers’ instruction did not result in a significant unloading effect. Deviating from the surgery manual provided by the manufacturer the implantation of a larger spring size while applying varus stress before releasing the absorber resulted in a significant pressure diminution. Contact pressure decreased significantly Δ0.20 ± 0.04 MPa p = 0.044. Performing the OW-HTO in 5° correction angle resulted in significant decreased contact pressure (Δ0.25 ± 0.10 MPa, p = 0.0036) and peak contact pressure (Δ0.39 ± 0.38 MPa, p = 0.029) compared with the native test cycle. With a 10° correction angle, OW-HTO significantly decreased area contact pressure by Δ0.32 ± 0.09 MPa, p = 0.006 and peak contact pressure by Δ0.48 ± 0.12 MPa, p = 0.0654 compared to OW-HTO 5°. Surgical treatment did not result in kinematic changes regarding the superior–inferior translation of the medial joint section. A significant difference was observed for the translation towards the lateral compartment for the ATLAS system Δ1.31 ± 0.54 MPa p = 0.022 and the osteotomy Δ3.51 ± 0.92 MPa p = 0.001. Furthermore, significant shifting varus to valgus rotation of the treated knee joint was verified for HTO 5° about Δ2.97–3.69° and for HTO 10° Δ4.11–5.23° (pHTO 5 = 0.0012; pHTO 10 = 0.0007) over the entire extension cycle. Conclusion: OW-HTO results in a significant unloading of the medial compartment. Implantation of an extra-capsular absorbing device did not result in a significant unloading until the implantation technique was applied against the manufacturer’s recommendation. While the clinical difficulty for young and active patients with straight-leg axis and early degenerative changes of the medial compartment persists further biomechanical research to develop sufficient unloading devices is required.


  • Open Access

    10-Year Survival Rates After High Tibial Osteotomy Using Angular Stable Internal Plate Fixation: Case Series With Subgroup Analysis of Outcomes After Combined Autologous Chondrocyte Implantation and High Tibial Osteotomy

    by Lisa Bode, Helge Eberbach, Anna-Sophie Brenner, Ferdinand Kloos, Philipp Niemeyer, Hagen Schmal, Norbert P. Suedkamp, Gerrit Bode

    Background: Good-to-excellent midterm results after high tibial osteotomy (HTO) to treat medial compartment cartilage defects or osteoarthritis (OA) have been published, but little is known about long-term survival rates in terms of conversion to total knee arthroplasty (TKA) using angular stable internal plate fixation. Purpose: To determine TKA-free survival rates and functional and radiological outcomes at 10 years after HTO. A subgroup analysis of patients who underwent combined HTO and autologous cartilage implantation (ACI) was also performed. Study Design: Case series; Level of evidence, 4. Methods: Included were 125 patients with a mean follow-up of 9.90 ± 2.25 years; 90 patients underwent HTO for medial OA, and 35 patients underwent ACI and HTO for medial focal cartilage defects. Functional outcome measures included visual analog scale (VAS) for pain, Lysholm, International Knee Documentation Committee (IKDC), and Knee injury and Osteoarthritis Outcome Score (KOOS) subscales and KOOS4 (average of 4 KOOS subscales: Pain, Symptoms, Sport, and Quality of Life). Radiological outcomes included lateral distal femoral angle, medial proximal tibial angle, and joint line convergence angle. Results: Overall, 16 patients required conversion to TKA at a mean 86.75 ± 25.73 months (10-year survival rate, 87.2%). Only 2 patients in the HTO+ACI subgroup required a conversion to TKA (10-year survival rate, 94.3%). The complication rate for all patients was 8.8%. In both the HTO and HTO+ACI subgroups, VAS pain levels decreased and Lysholm scores increased significantly from pre- to postoperatively ( P < .001). A higher preoperative Tegner score led to a significantly lower risk for conversion to TKA ( P = .001), and a preoperative body mass index of ≥35 was associated with a significantly higher risk ( P = .019), as was female sex ( P = .046). Radiological parameters remained within physiological ranges. The postoperative joint line conversion angle did correlate with postoperative functional outcome but not with TKA conversion. Conclusion: Long-term results of HTO for medial compartment OA or cartilage defects with underlying varus deformity were good to excellent. In particular, patients who underwent HTO+ACI presented excellent long-term survival rates. HTO, therefore, delays or prevents TKA implantation, especially in young, active patients with medial compartment damage.


  • Open Access

    Isolated revision meniscal repair – failure rates, clinical outcome, and patient satisfaction

    by Andreas Fuchs, Ferdinand Kloos, Gerrit Bode, Kaywan Izadpanah, Norbert P. Südkamp, Matthias J. Feucht

    Failure of isolated primary meniscal repair must be expected in approximately 10–25% of cases. Patients requiring revision surgery may benefit from revision meniscal repair, however, the results of this procedure remain underreported. The purpose of this study was therefore to evaluate the outcome and failure rates of isolated revision meniscal repair in patients with re-tears or failed healing after previous meniscal repair in stable knee joints. A chart review was performed to identify all patients undergoing revision meniscal repair between 08/2010 and 02/2016. Only patients without concomitant procedures, without ligamentous insufficiency, and a minimum follow-up of 24 months were included. The records of all patients were reviewed to collect patient demographics, injury patterns of the meniscus, and details about primary and revision surgery. Follow-up evaluation included failure rates, clinical outcome scores (Lysholm Score, KOOS Score), sporting activity (Tegner scale), and patient satisfaction. A total of 12 patients with a mean age of 22 ± 5 years were included. The mean time between primary repair and revision repair was 27 ± 21 months. Reasons for failed primary repairs were traumatic re-tears in 10 patients (83%) and failed healing in two patients (17%). The mean follow-up period after revision meniscal repair was 43 (± 23.4) months. Failure of revision meniscal repair occurred in 3 patients (25%). In two of these patients, successful re-revision repair was performed. At final follow-up, the mean Lysholm Score was 95.2 (± 4.2) with a range of 90–100, representing a good to excellent result in all patients. The final assessment of the KOOS subscores also showed good to excellent results. The mean Tegner scale was 6.8 ± 1.8, indicating a relatively high level of sports participation. Ten patients (83%) were either satisfied or very satisfied with the outcome. In patients with re-tears or failed healing after previous isolated meniscal repair, revision meniscal repair results in good to excellent knee function, high level of sports participation, and high patient satisfaction. The failure rate is slightly higher compared to isolated primary meniscal repair, but still acceptable. Therefore, revision meniscal repair is worthwhile in selected cases in order to save as much meniscal tissue as possible.


  • High tibial osteotomy increases patellofemoral pressure if adverted proximal, while open-wedge HTO with distal biplanar osteotomy discharges the patellofemoral joint: different open-wedge high tibial osteotomies compared to an extra-articular unloading device

    by Ferdinand Kloos, Christoph Becher, Benjamin Fleischer, Matthias J. Feucht, Lisa Hohloch, Norbert Südkamp, Philipp Niemeyer, Gerrit Bode

    Valgus high tibial osteotomy (HTO) and a recently introduced extra-articular absorber have been shown to efficiently unload the medial compartment of the knee. However, only little is known about the influence of these treatment modalities on biomechanics of the patellofemoral joint. The purpose of this study was to investigate and compare the impact of different HTO techniques and implantation of an extra-articular absorber on patellofemoral contact forces.