Abid Soomro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Abid Soomro has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Keith Robert Pullen
School of Mathematics, Computer Science and Engineering, City University of London, London EC1V 0HB, UK
2 shared publications - Mustafa E. Amiryar
School of Mathematics, Computer Science and Engineering at City, University of London, London EC1V 0HB, UK
2 shared publications - Daniel Nankoo
School of Mathematics, Computer Science and Engineering, University of London, London EC1V 0HB, UK
1 shared publication
Latest Publications
- Open Access
- 20 April 2021
- Published by MDPI AG in Clean Technologies
- Vol. 3 (2) , 351-376
Hybrid PV System with High Speed Flywheel Energy Storage for Remote Residential Loads
Due to low system inertia in microgrids, frequencies may vary rapidly from the nominal value, leading to the complete blackout of the system unless there is an adequate spinning reserve available for balancing the supply with the demand load. This issue of instability in microgrids under islanded operation has attracted particular attention recently. A diesel generator is considered to be an ideal spinning reserve to provide back-up power to the load along with the renewable energy source in islanded system. However, the high maintenance cost and CO2 emissions of diesel generator are detrimental factors which have inspired searches for more cost effective and cleaner technologies. The integration of an energy storage system (ESS) in islanded system along with generator not only reduces generator maintenance costs but also reduces the CO2 emissions by limiting its operating hours. This paper proposes an islanded PV hybrid microgrid system (PVHMS) utilizing flywheel energy storage systems (FESS) as an alternative to battery technology to support the PV system and meet the peak demand of a small residential town with 100 dwellings. The diesel generator is used in the islanded system as a spinning reserve to maintain the stability of the islanded system when the PV system and flywheel storage cannot meet the load demand. Results of analysis of such a system demonstrate that flywheel energy storage technology of appropriate size offers a viable solution to support the operation of the standalone PV system. Furthermore, the reduction in CO2 emissions and fuel consumption has been quantified as compared with the case with flywheel energy storage systems which means the diesel generator but always be operating.
- 20 April 2021
- Published by MDPI AG in Clean Technologies
- Vol. 3 (2) , 351-376
Open AccessHybrid PV System with High Speed Flywheel Energy Storage for Remote Residential Loads
Due to low system inertia in microgrids, frequencies may vary rapidly from the nominal value, leading to the complete blackout of the system unless there is an adequate spinning reserve available for balancing the supply with the demand load. This issue of instability in microgrids under islanded operation has attracted particular attention recently. A diesel generator is considered to be an ideal spinning reserve to provide back-up power to the load along with the renewable energy source in islanded system. However, the high maintenance cost and CO2 emissions of diesel generator are detrimental factors which have inspired searches for more cost effective and cleaner technologies. The integration of an energy storage system (ESS) in islanded system along with generator not only reduces generator maintenance costs but also reduces the CO2 emissions by limiting its operating hours. This paper proposes an islanded PV hybrid microgrid system (PVHMS) utilizing flywheel energy storage systems (FESS) as an alternative to battery technology to support the PV system and meet the peak demand of a small residential town with 100 dwellings. The diesel generator is used in the islanded system as a spinning reserve to maintain the stability of the islanded system when the PV system and flywheel storage cannot meet the load demand. Results of analysis of such a system demonstrate that flywheel energy storage technology of appropriate size offers a viable solution to support the operation of the standalone PV system. Furthermore, the reduction in CO2 emissions and fuel consumption has been quantified as compared with the case with flywheel energy storage systems which means the diesel generator but always be operating.
- Open Access
- 25 October 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (21) , 4537
Performance and Loss Analysis of Squirrel Cage Induction Machine Based Flywheel Energy Storage System
Flywheel energy storage systems (FESS) are one of the earliest forms of energy storage technologies with several benefits of long service time, high power density, low maintenance, and insensitivity to environmental conditions being important areas of research in recent years. This paper focusses on the electrical machine and power electronics, an important part of a flywheel system, the electrical machine rotating with the flywheel inertia in order to perform charge-discharge cycles. The type of machine used in the electrical drive plays an important role in the characteristics governing electrical losses as well as standby losses. Permanent magnet synchronous machine (PMSM) and induction machines (IM) are the two most common types of electric machines used in FESS applications where the latter has negligible standby losses due to its lower rotor magnetic field until energised by the stator. This paper describes research in which the operational and standby losses of a squirrel-cage induction machine-based flywheel storage system (SCIM-FESS) are modelled as a system developed in MATLAB/Simulink environment inclusive of the control system for the power electronics converters. Using the proposed control algorithm and in-depth analysis of the system losses, a detailed assessment of the dynamic performance of the SCIM-FESS is performed for different states of charging, discharging, and standby modes. The results of the analysis show that, in presence of system losses including aerodynamic and bearing friction losses, the SCIM-FESS has satisfactory characteristics in energy regulation and dynamic response during load torque variations. The compliance of FESS and its conversion between the generating and motoring mode within milliseconds show the responsiveness of the proposed control system.
- 25 October 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (21) , 4537
Open AccessPerformance and Loss Analysis of Squirrel Cage Induction Machine Based Flywheel Energy Storage System
Flywheel energy storage systems (FESS) are one of the earliest forms of energy storage technologies with several benefits of long service time, high power density, low maintenance, and insensitivity to environmental conditions being important areas of research in recent years. This paper focusses on the electrical machine and power electronics, an important part of a flywheel system, the electrical machine rotating with the flywheel inertia in order to perform charge-discharge cycles. The type of machine used in the electrical drive plays an important role in the characteristics governing electrical losses as well as standby losses. Permanent magnet synchronous machine (PMSM) and induction machines (IM) are the two most common types of electric machines used in FESS applications where the latter has negligible standby losses due to its lower rotor magnetic field until energised by the stator. This paper describes research in which the operational and standby losses of a squirrel-cage induction machine-based flywheel storage system (SCIM-FESS) are modelled as a system developed in MATLAB/Simulink environment inclusive of the control system for the power electronics converters. Using the proposed control algorithm and in-depth analysis of the system losses, a detailed assessment of the dynamic performance of the SCIM-FESS is performed for different states of charging, discharging, and standby modes. The results of the analysis show that, in presence of system losses including aerodynamic and bearing friction losses, the SCIM-FESS has satisfactory characteristics in energy regulation and dynamic response during load torque variations. The compliance of FESS and its conversion between the generating and motoring mode within milliseconds show the responsiveness of the proposed control system.