    The 2023 wearable photoplethysmography roadmap

    by Peter H Charlton, John Allen, Raquel Bailón, Stephanie Baker, Joachim A Behar, Fei Chen, Gari D Clifford, David A Clifton, Harry J Davies, Cheng Ding, et al.

    Photoplethysmography is a key sensing technology which is used in wearable devices such as smartwatches and fitness trackers. Currently, photoplethysmography sensors are used to monitor physiological parameters including heart rate and heart rhythm, and to track activities like sleep and exercise. Yet, wearable photoplethysmography has potential to provide much more information on health and wellbeing, which could inform clinical decision making. This Roadmap outlines directions for research and development to realise the full potential of wearable photoplethysmography. Experts discuss key topics within the areas of sensor design, signal processing, clinical applications, and research directions. Their perspectives provide valuable guidance to researchers developing wearable photoplethysmography technology.


  • Open Access

    Overestimation of Oxygen Saturation Measured by Pulse Oximetry in Hypoxemia. Part 1: Effect of Optical Pathlengths-Ratio Increase

    by Eyal Elron, Ruben Bromiker, Ori Gleisner, Ohad Yosef-Hai, Ori Goldberg, Itamar Nitzan, Meir Nitzan

    On average, arterial oxygen saturation measured by pulse oximetry (SpO2) is higher in hypoxemia than the true oxygen saturation measured invasively (SaO2), thereby increasing the risk of occult hypoxemia. In the current article, measurements of SpO2 on 17 cyanotic newborns were performed by means of a Nellcor pulse oximeter (POx), based on light with two wavelengths in the red and infrared regions (660 and 900 nm), and by means of a novel POx, based on two wavelengths in the infrared region (761 and 820 nm). The SpO2 readings from the two POxs showed higher values than the invasive SaO2 readings, and the disparity increased with decreasing SaO2. SpO2 measured using the two infrared wavelengths showed better correlation with SaO2 than SpO2 measured using the red and infrared wavelengths. After appropriate calibration, the standard deviation of the individual SpO2−SaO2 differences for the two-infrared POx was smaller (3.6%) than that for the red and infrared POx (6.5%, p < 0.05). The overestimation of SpO2 readings in hypoxemia was explained by the increase in hypoxemia of the optical pathlengths-ratio between the two wavelengths. The two-infrared POx can reduce the overestimation of SpO2 measurement in hypoxemia and the consequent risk of occult hypoxemia, owing to its smaller increase in pathlengths-ratio in hypoxemia.


  • Open Access

    Feasibility of Precision Medicine in Hypertension Management—Scope and Technological Aspects

    by Meir Nitzan, Itamar Nitzan

    Personalized management of diseases by considering relevant patient features enables optimal treatment, instead of management according to an average patient. Precision management of hypertension is important, because both susceptibility to complications and response to treatment vary between individuals. While the use of genomic and proteomic personal features for widespread precision hypertension management is not practical, other features, such as age, ethnicity, and cardiovascular diseases, have been utilized in guidelines for hypertension management. In precision medicine, more blood-pressure-related clinical and physiological characteristics in the patient’s profile can be utilized for the determination of the threshold of hypertension and optimal treatment. Several non-invasive and simple-to-use techniques for the measurement of hypertension-related physiological features are suggested for use in precision management of hypertension. In order to provide precise management of hypertension, accurate measurement of blood pressure is required, but the available non-invasive blood pressure measurement techniques, auscultatory sphygmomanometry and oscillometry, have inherent significant inaccuracy—either functional or technological—limiting the precision of personalized management of hypertension. A novel photoplethysmography-based technique for the measurement of systolic blood pressure that was recently found to be more accurate than the two available techniques can be utilized for more precise and personalized hypertension management.


  • Open Access

    The Various Oximetric Techniques Used for the Evaluation of Blood Oxygenation

    by Meir Nitzan, Itamar Nitzan, Yoel Arieli

    Adequate oxygen delivery to a tissue depends on sufficient oxygen content in arterial blood and blood flow to the tissue. Oximetry is a technique for the assessment of blood oxygenation by measurements of light transmission through the blood, which is based on the different absorption spectra of oxygenated and deoxygenated hemoglobin. Oxygen saturation in arterial blood provides information on the adequacy of respiration and is routinely measured in clinical settings, utilizing pulse oximetry. Oxygen saturation, in venous blood (SvO2) and in the entire blood in a tissue (StO2), is related to the blood supply to the tissue, and several oximetric techniques have been developed for their assessment. SvO2 can be measured non-invasively in the fingers, making use of modified pulse oximetry, and in the retina, using the modified Beer–Lambert Law. StO2 is measured in peripheral muscle and cerebral tissue by means of various modes of near infrared spectroscopy (NIRS), utilizing the relative transparency of infrared light in muscle and cerebral tissue. The primary problem of oximetry is the discrimination between absorption by hemoglobin and scattering by tissue elements in the attenuation measurement, and the various techniques developed for isolating the absorption effect are presented in the current review, with their limitations.


  • Systolic blood pressure measurement by detecting the photoplethysmographic pulses and electronic Korotkoff-sounds during cuff deflation

    by Eran Shalom, Elad Hirshtal, Itzchak Slotki, Linda Shavit, Yitzhak Yitzhaky, Shlomo Engelberg, Meir Nitzan

    Objective: The commonly used noninvasive techniques for blood pressure measurement, auscultatory Korotkoff-based sphygmomanometry and oscillometry, both have limitations in their clinical use. The former is relatively accurate but is limited to use in a physician’s office because its automatic variant is subject to noise artifacts. Automatic oscillometers can be used at home, but their accuracy is low. In the current study, we present two electronic techniques for systolic blood pressure (SBP) measurement that are more accurate than the available techniques, and can be automated. Approach: The cuff-based electronic techniques for SBP measurement used in this study utilize a finger photoplethysmographic (PPG) signal or electronically recorded Korotkoff sounds, and detection of the first appearance of PPG or Korotkoff-based pulses during cuff deflation. Most noise artefacts were eliminated by means of a time-reference signal—a PPG signal measured in the free hand. Main results: The two electronic techniques showed good agreement. Both techniques were found to be more accurate than the auscultatory Korotkoff-based technique, the gold-reference, in those examinations where large discrepancies were found between them, since the PPG and Korotkoff-based electronic pulses appeared before Korotkoff sounds were heard. The PPG signal in the free hand, that served as a time-reference signal, enabled both electronic techniques to eliminate artefacts—noise pulses that appeared outside the time intervals in which a blood-pressure-related pulses should appear. Significance: The two electronic techniques provide accurate systolic blood pressure measurements and can be implemented automatically, as was shown in a previous study on blood pressure measurement by PPG. Trial registration number of the institutional ethical committee of Shaare-Zedek Medical Center, Jerusalem is 0154-16-SZMC.


  • Open Access

    Pulse Oximetry with Two Infrared Wavelengths without Calibration in Extracted Arterial Blood

    by Ohad Yossef Hay, Meir Cohen, Itamar Nitzan, Yair Kasirer, Sarit Shahroor-Karni, Yitzhak Yitzhaky, Shlomo Engelberg, Meir Nitzan

    Oxygen saturation in arterial blood (SaO2) provides information about the performance of the respiratory system. Non-invasive measurement of SaO2 by commercial pulse oximeters (SpO2) make use of photoplethysmographic pulses in the red and infrared regions and utilizes the different spectra of light absorption by oxygenated and de-oxygenated hemoglobin. Because light scattering and optical path-lengths differ between the two wavelengths, commercial pulse oximeters require empirical calibration which is based on SaO2 measurement in extracted arterial blood. They are still prone to error, because the path-lengths difference between the two wavelengths varies among different subjects. We have developed modified pulse oximetry, which makes use of two nearby infrared wavelengths that have relatively similar scattering constants and path-lengths and does not require an invasive calibration step. In measurements performed on adults during breath holding, the two-infrared pulse oximeter and a commercial pulse oximeter showed similar changes in SpO2. The two pulse oximeters showed similar accuracy when compared to SaO2 measurement in extracted arterial blood (the gold standard) performed in intensive care units on newborns and children with an arterial line. Errors in SpO2 because of variability in path-lengths difference between the two wavelengths are expected to be smaller in the two-infrared pulse oximeter.


  • The effect of patent ductus arteriosus on pre-ductal and post-ductal perfusion index in preterm neonates

    by Itamar Nitzan, Cathy Hammerman, Daniel Fink, Meir Nitzan, Robert Koppel, Ruben Bromiker

    Objective : The ductus arteriosus is a blood vessel that connects the pulmonary artery to the descending aorta during fetal life and generally undergoes spontaneous closure shortly after birth. In premature neonates it often fails to close (patent ductus arteriosus—PDA), which can result in diversion of a significant part of the left-ventricular cardiac output to the pulmonary circulation. This left-to-right shunt may result in significant increase of pulmonary blood flow and decrease of systemic perfusion (hemodynamically significant PDA—hsPDA), which may lead to severe neonatal morbidity. The study objective was to find the relationship between hsPDA and perfusion index (PI), a photoplethysmographic parameter related to systemic perfusion. Approach : PI measures the relative systolic increase in tissue light absorption due to the systolic increase in the tissue blood volume. PI has been found to be directly related to tissue perfusion and is therefore expected to be affected by hsPDA. Main results : PI was found to be higher in preterm neonates with hsPDA after first week of life, in comparison to those with closed DA, despite the lower systemic perfusion, probably due to reverse flow during diastole. Significance : In our study, perfusion index increased despite the lower systemic perfusion, indicating that in neonates with hsPDA, perfusion index is not necessarily a measure of perfusion. Nevertheless, PI can be used as a screening tool for suspicious PDA, in order to select a relatively small group of neonates for a more definitive examination by echocardiography, which is not suitable for universal screening.


  • Open Access

    More accurate systolic blood pressure measurement is required for improved hypertension management: a perspective

    by Meir Nitzan, Itzchak Slotki, Linda Shavit

    The commonly used techniques for systolic blood pressure (SBP) and diastolic blood pressure (DBP) measurement are the auscultatory Korotkoff-based sphygmomanometry and oscillometry. The former technique is relatively accurate but is limited to a physician’s office because its automatic variant is subject to noise artifacts. Consequently, the Korotkoff-based measurement overestimates the blood pressure in some patients due to white coat effect, and because it is a single measurement, it cannot properly represent the variable blood pressure. Automatic oscillometry can be used at home by the patient and is preferred even in clinics. However, the technique’s accuracy is low and errors of 10–15 mmHg are common. Recently, we have developed an automatic technique for SBP measurement, based on an arm pressure cuff and a finger photoplethysmographic probe. The technique was found to be significantly more accurate than oscillometry, and comparable to the Korotkoff-based technique, the reference-standard for non-invasive blood pressure measurements. The measurement of SBP is a mainstay for the diagnosis and follow-up of hypertension, which is a major risk factor for several adverse events, mainly cardiovascular. Lowering blood pressure evidently reduces the risk, but excessive lowering can result in hypotension and consequently hypoperfusion to vital organs, since blood pressure is the driving force for blood flow. Erroneous measurement by 10 mmHg can lead to a similar unintended reduction of SBP and may adversely affect patients treated to an SBP of 120–130 mmHg. In particular, in elderly patients, unintended excessive reduction of blood pressure due to inaccurate SBP measurement can result in cerebral hypoperfusion and consequent cognitive decline. By using a more accurate technique for automatic SBP measurement (such as the photoplethysmographic-based technique), the optimal blood pressure target can be achieved with lower risk for hypotension and its adverse events.