PWPatrick L. Whitlow

Patrick L. Whitlow

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Patrick L. Whitlow has a total of 81 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Use of a Novel Crossing and Re-Entry System in Coronary Chronic Total Occlusions That Have Failed Standard Crossing Techniques

    by Patrick L. Whitlow, M. Nicholas Burke, William L. Lombardi, R. Michael Wyman, Jeffrey W. Moses, Emmanouil S. Brilakis, Richard R. Heuser, Charanjit S. Rihal, Alexandra J. Lansky, Craig A. Thompson


  • Subintimal guidewire tracking during successful percutaneous therapy for chronic coronary total occlusions: Insights from an intravascular ultrasound analysis

    by Kamran I. Muhammad, William L. Lombardi, Ryan Christofferson, Patrick L. Whitlow

    Objectives: We sought to determine the frequency of subintimal guidewire tracking during successful percutaneous coronary intervention (PCI) for chronic coronary total occlusions (CTOs) and to better understand the procedural implications of this event. Background: Successful PCI for chronic CTO is associated with improved outcomes in patients with ischemia. While subintimal guidewire tracking resulting in failure to cross is recognized as the major mode of failure for CTO PCI, the implications of subintimal guidewire tracking during successful CTO PCI are unknown. Methods: Between March 2007 and October 2007, 26 consecutive patients, each with one de‐novo CTO lesion successfully crossed with a guidewire were included in the analysis. Intravascular ultrasound (IVUS) was performed in each CTO vessel after guidewire crossing. Cases were classified as having definite subintimal wire tracking or no clear evidence of subintimal wire tracking based on analysis of IVUS images. Results: Subintimal wire tracking occurred in 45% of cases. In cases where subintimal wire tracking was present, a previous attempt at CTO PCI was more common (42% vs. 7%, P ≤ 0.05). Subintimal wire tracking was also associated with significantly longer final mean stent length (71 vs. 50 mm), procedure time (122 vs. 69 min), fluoroscopy time (47 vs. 22 min), and contrast dose (300 vs. 199 mL, P ≤ 0.05 for all). There was one perforation in the subintimal group which was successfully treated with stent placement. Conclusions: Subintimal wire tracking occurs frequently during successful PCI for CTO and is associated with increased lesion and procedural complexity.© 2011 Wiley Periodicals, Inc


  • Top Cited Papers

    Acute and 12-Month Results With Catheter-Based Mitral Valve Leaflet Repair

    by Patrick L. Whitlow, Ted Feldman, Wes R. Pedersen, D. Scott Lim, Robert Kipperman, Richard Smalling, Tanvir Bajwa, Howard C. Herrmann, John Lasala, James T. Maddux, et al.


  • Initial experience with a dedicated coronary re‐entry device for revascularization of chronic total occlusions

    by Patrick L. Whitlow, William L. Lombardi, Mario Araya, R. Michael Wyman, Humberto Torres, Christian Dauvergne, Etsuo Tsuchikane, Alexandra Lansky, Craig A. Thompson

    Objective: The aim of this registry was to evaluate a new device designed to facilitate antegrade guidewire re‐entry into the true lumen of a chronic total coronary occlusion (CTO) from the adjacent subintimal space. Background: Successful recanalization of CTOs results in clinical improvement in appropriately selected patients. CTO intervention is time‐ and resource‐consuming, and a simplified approach enabling antegrade guidewire re‐entry into the distal true lumen might improve success. Methods: Patients with CTO and ischemia were entered into a prospective registry regardless of lesion characteristics. If wire manipulation resulted in subintimal wire entrapment, a new re‐entry tool (a 2.5‐mm flat subintimal balloon with two exit ports offset by 180°) was used as a platform to attempt guidewire penetration into the distal true lumen. The primary endpoint assessed was successful device‐guided re‐entry. Standard techniques were then utilized to open the CTO. Results: In 40 consecutive CTO lesions attempted, 19 resulted in subintimal wire entrapment (mean occlusion length 44 mm). Sixteen of these 19 were successfully crossed with an antegrade guidewire into the distal true lumen using the new device (84%). One patient with unsuccessful re‐entry was subsequently recanalized with a retrograde technique. All crossed lesions were stented (17/17), resulting in TIMI 3 flow without major complications. Two cases were unsuccessful. One patient had a grade I coronary perforation requiring no treatment. Conclusions: A new device to recanalize CTOs complicated by subintimal wire entrapment can be used successfully by experienced operators. Further study of this coronary re‐entry device is ongoing.


  • One-year results of percutaneous myocardial revascularization for refractory angina pectoris

    by Patrick L. Whitlow, Samuel J. DeMaio, Emerson C. Perin, William W. O’neill, John M. Lasala, Joel E. Schneider, Lou S. McKeever, Ari M. Ezratty, William D. Knopf, Eric R. Powers, et al.


  • Emergency Coronary Artery Bypass Surgery in the Contemporary Percutaneous Coronary Intervention Era

    by Niranjan Seshadri, Patrick L. Whitlow, Naveen Acharya, Penny Houghtaling, Eugene H. Blackstone, Stephen G. Ellis

    Background— Since the advent of percutaneous coronary interventions (PCIs), technological advances, adjunctive pharmacotherapy, and increasing operator experience have contributed to lowering the occurrence of major complications. However, emergency coronary artery bypass surgery (CABG) for failed PCI is still associated with important morbidity and mortality, even in the era of coronary stenting. We sought to determine the prevalence, indications, predictors, and complications of emergency CABG after PCI in the past decade. Methods and Results— We reviewed 18 593 PCIs performed from 1992 through 2000. There was a need for emergency CABG in 113 (0.61%) cases. The major indications were extensive dissection (n=61, 54%), perforation/tamponade (n=23, 20%), and recurrent acute closure (n=23, 20%). Prevalence of emergency CABG decreased from 1.5% of PCIs in 1992 to 0.14% in 2000 ( P P P = 0.028), whereas history of prior bypass surgery and use of stents resulted in a decreased need for emergency CABG ( P Conclusions— The need for emergency CABG has considerably decreased over time. Risk factors include female sex and a higher ACC/AHA score of the intervened lesion. However, morbidity and mortality of emergency CABG remain high even in the new millennium.


  • Carotid Artery Stenting Protected With an Emboli Containment System

    by Patrick L. Whitlow, Pedro Lylyk, Hugo Londero, Oscar A. Mendiz, Klaus Mathias, Horst Jaeger, Juan Parodi, Claudio SchönHolz, Jose Milei

    Background and Purpose — Fear of distal embolization and stroke has aroused concern regarding carotid stenting. Devices to protect the cerebral circulation may make carotid stenting safer. Methods — A multidisciplinary study group tested a balloon occlusion-aspiration emboli entrapment device in conjunction with carotid stenting. The device consists of an elastomeric balloon on a steerable wire with a detachable adapter that inflates and deflates the distal temporary occlusion balloon. An aspiration catheter is used to remove trapped emboli after stenting and before occlusion balloon deflation. Results — Seventy-five patients with severe internal carotid artery stenosis were treated with stents deployed with this cerebrovasculature protection system. All 75 patients (100%) had grossly visible particulate material aspirated, and all were treated successfully without major or minor stroke or death at 30 days. Preintervention stenosis was 81±10%, and residual stenosis was 5±7%. Nine patients (12%) had angiographic evidence of thrombus before intervention, but no patient had thrombus or vessel cutoff after the procedure. Four patients (5%) developed transient neurological symptoms during protection balloon occlusion, but symptoms resolved with balloon deflation. The 22 to 667 particles aspirated per patient ranged from 3.6 to 5262 μm in maximum diameter (mean, 203±256 μm). These particles included fibrous plaque debris, lipid or cholesterol vacuoles, and calcific plaque fragments. Conclusions — Protected carotid stenting was performed successfully and safely in this study early in the experience with cerebrovascular protection devices. Particulate emboli are frequent with stenting, and cerebral protection will likely be necessary to minimize stroke. Randomized trials comparing protected carotid stenting with endarterectomy are warranted.


  • Results of the study to determine rotablator and transluminal angioplasty strategy (STRATAS)

    by Patrick L Whitlow, Theodore A Bass, Robert M Kipperman, Barry L Sharaf, Kalon K.L Ho, Donald E Cutlip, Yan Zhang, Richard E Kuntz, David O Williams, David M Lasorda, et al.