Karen Lok Man Tung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Karen Lok Man Tung has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Michael Ka Wah Li
Pamela Youde Nethersole Eastern Hosp, Dept Surg, Chai Wan, Hong Kong, Peoples R China
2 shared publicationsChung N. Tang
1 shared publicationCliff Chi Chiu Chung
Department of Surgery Pamela Youde Nethersole Eastern Hospital Hong Kong China
1 shared publicationEric C.H. Lai
1 shared publicationG. P. C. Yang
Department of Surgery, Pamela Youde Nethersole Eastern Hospital, Chai Wan, Hong Kong SAR, China
1 shared publicationGeorge P.C. Yang
1 shared publication
Latest Publications
- 27 October 2016
- Published by Wiley in Asian Journal of Endoscopic Surgery
- Vol. 9 (4) , 344-347
Preperitoneal onlay mesh repair for ventral abdominal wall and incisional hernia: a novel technique
Intraperitoneal onlay mesh repair is a current technique for laparoscopic repair of ventral and incisional hernias. However, the placement of synthetic mesh intraperitoneally may potentially lead to mesh-induced complications such as adhesive intestinal obstruction, enterocutaneous fistula, or even mesh erosion into organs. Inspired by the concept of laparoscopic inguinal hernia repair, we developed a novel technique: preperitoneal onlay mesh repair (PPOM). This involves placing the mesh in the preperitoneal plane to help eliminate mesh-induced complications. Our first case of PPOM was performed on a 54-year-old woman who developed a complex incisional hernia after multiple abdominal operations. The total size of the hernia defect was 8 × 13 cm. The peritoneal flap was carefully created with synthetic mesh placed on the preperitoneal plane, and then it was completely closed with sutures. The patient had an uneventful recovery except for a small seroma. We herein report the first case of incisional hernia successfully treated by this novel technique, PPOM. We explain the reasons to perform PPOM, the advantages it offers, and why we named this novel technique “PPOM.”
- 27 October 2016
- Published by Wiley in Asian Journal of Endoscopic Surgery
- Vol. 9 (4) , 344-347
Preperitoneal onlay mesh repair for ventral abdominal wall and incisional hernia: a novel technique
Intraperitoneal onlay mesh repair is a current technique for laparoscopic repair of ventral and incisional hernias. However, the placement of synthetic mesh intraperitoneally may potentially lead to mesh-induced complications such as adhesive intestinal obstruction, enterocutaneous fistula, or even mesh erosion into organs. Inspired by the concept of laparoscopic inguinal hernia repair, we developed a novel technique: preperitoneal onlay mesh repair (PPOM). This involves placing the mesh in the preperitoneal plane to help eliminate mesh-induced complications. Our first case of PPOM was performed on a 54-year-old woman who developed a complex incisional hernia after multiple abdominal operations. The total size of the hernia defect was 8 × 13 cm. The peritoneal flap was carefully created with synthetic mesh placed on the preperitoneal plane, and then it was completely closed with sutures. The patient had an uneventful recovery except for a small seroma. We herein report the first case of incisional hernia successfully treated by this novel technique, PPOM. We explain the reasons to perform PPOM, the advantages it offers, and why we named this novel technique “PPOM.”
- 1 January 2016
- Published by AME Publishing Company in Annals of Laparoscopic and Endoscopic Surgery
- Vol. 1 (1) , 46
Hybrid natural orifice transluminal endoscopic surgery colectomy versus conventional laparoscopic colectomy for left-sided colonic tumors: intermediate follow up of a randomized trial
Background: In 2009, we have described a novel technique of laparoscopic colectomy without abdominal incision [hybrid natural orifice transluminal endoscopic surgery (NOTES) colectomy] where laparoscopic dissection and intra-corporeal anastomosis were performed as usual but the specimen was delivered through the anus with the use of transanal endoscopic operation (TEO) device set-up without mini-laparotomy. We have completed a randomized trial comparing this technique with conventional laparoscopic colectomy (CL) for left sided colonic tumors, and early short term results had showed that in selected group of patients, they can enjoy the full benefit of minimally invasive surgery with significant lesser wound pain as well as a lower wound infection rate. This study is a follow up of previous trial, and aims to report immediate outcome between the two groups. Method: All 70 patients including 35 patients in the hybrid NOTES group and 35 patients in conventional colectomy group were continued to follow up in our outpatient clinic with regular surveillance. Patients were compared for clinicopathological variables, disease recurrence and survival rates. Results: Clinicopathological details were comparable between the two groups. Within median follow up of 37–45 months in the two groups, no statistically significant difference was observed in disease recurrence rate (conventional: 8.57%; hybrid: 5.71%; P value: 0.22) and 3-year disease free survival rates (conventional: 42%; hybrid: 62%; P value: 0.144). While the overall 3-year survival rate is statistically shorter in the conventional group (conventional: 54%; hybrid: 71%; P value Conclusions: It is safe for us to offer hybrid colectomy for selected patients with left sided colonic cancer, without adversely affect their oncological outcome and survival, while at the same time, benefit of minimally invasive surgery can be fully expressed.
- 1 January 2016
- Published by AME Publishing Company in Annals of Laparoscopic and Endoscopic Surgery
- Vol. 1 (1) , 46
Hybrid natural orifice transluminal endoscopic surgery colectomy versus conventional laparoscopic colectomy for left-sided colonic tumors: intermediate follow up of a randomized trial
Background: In 2009, we have described a novel technique of laparoscopic colectomy without abdominal incision [hybrid natural orifice transluminal endoscopic surgery (NOTES) colectomy] where laparoscopic dissection and intra-corporeal anastomosis were performed as usual but the specimen was delivered through the anus with the use of transanal endoscopic operation (TEO) device set-up without mini-laparotomy. We have completed a randomized trial comparing this technique with conventional laparoscopic colectomy (CL) for left sided colonic tumors, and early short term results had showed that in selected group of patients, they can enjoy the full benefit of minimally invasive surgery with significant lesser wound pain as well as a lower wound infection rate. This study is a follow up of previous trial, and aims to report immediate outcome between the two groups. Method: All 70 patients including 35 patients in the hybrid NOTES group and 35 patients in conventional colectomy group were continued to follow up in our outpatient clinic with regular surveillance. Patients were compared for clinicopathological variables, disease recurrence and survival rates. Results: Clinicopathological details were comparable between the two groups. Within median follow up of 37–45 months in the two groups, no statistically significant difference was observed in disease recurrence rate (conventional: 8.57%; hybrid: 5.71%; P value: 0.22) and 3-year disease free survival rates (conventional: 42%; hybrid: 62%; P value: 0.144). While the overall 3-year survival rate is statistically shorter in the conventional group (conventional: 54%; hybrid: 71%; P value Conclusions: It is safe for us to offer hybrid colectomy for selected patients with left sided colonic cancer, without adversely affect their oncological outcome and survival, while at the same time, benefit of minimally invasive surgery can be fully expressed.
- 3 June 2015
- Published by Wiley in Asian Journal of Endoscopic Surgery
- Vol. 8 (3) , 275-280
Comparative study of 2‐D and bichanneled 3‐D laparoscopic images: Is there a difference?
Introduction: Lack of depth perception and spatial orientation are drawbacks of laparoscopic surgery. The advent of the 3‐D camera system enables surgeons to regain binocular vision. The aim of this study was to gain subjective and objective data to determine whether 3‐D systems are superior to 2‐D systems.Materials and Methods: Our study consisted of two parts: a laparoscopic training model and an actual operation assessment. In the first part, we compared two groups of surgeon (specialists and trainees) performing a laparoscopic task using a 2‐D and a 3‐D camera system. In the second part, surgeons were assessed on their performance of standard laparoscopic cholecystectomies using the two different camera systems. At the end of each assessment, participants were required to complete a questionnaire on their impressions of the comparative ease of operation tasks under 2‐D and 3‐D vision.Result: In the laboratory training model, trainees' performance time was shorter with the 3‐D camera system than with the 2‐D camera, but no difference was observed in the specialists group. In the surgical (cholecystectomy) assessment, no significant difference was observed between the 2‐D and 3‐D camera systems in terms of operative time and precision. The questionnaire indicated that all participants did not significantly favor the 3‐D system.Conclusion: We believe that the 3‐D camera system can allow young surgeons to perform standard laparoscopic tasks safely and quickly, so as to accelerate the learning curve. However, new‐generation 3‐D systems will be essential to overcome surgeons' discomfort.
- 3 June 2015
- Published by Wiley in Asian Journal of Endoscopic Surgery
- Vol. 8 (3) , 275-280
Comparative study of 2‐D and bichanneled 3‐D laparoscopic images: Is there a difference?
Introduction: Lack of depth perception and spatial orientation are drawbacks of laparoscopic surgery. The advent of the 3‐D camera system enables surgeons to regain binocular vision. The aim of this study was to gain subjective and objective data to determine whether 3‐D systems are superior to 2‐D systems.Materials and Methods: Our study consisted of two parts: a laparoscopic training model and an actual operation assessment. In the first part, we compared two groups of surgeon (specialists and trainees) performing a laparoscopic task using a 2‐D and a 3‐D camera system. In the second part, surgeons were assessed on their performance of standard laparoscopic cholecystectomies using the two different camera systems. At the end of each assessment, participants were required to complete a questionnaire on their impressions of the comparative ease of operation tasks under 2‐D and 3‐D vision.Result: In the laboratory training model, trainees' performance time was shorter with the 3‐D camera system than with the 2‐D camera, but no difference was observed in the specialists group. In the surgical (cholecystectomy) assessment, no significant difference was observed between the 2‐D and 3‐D camera systems in terms of operative time and precision. The questionnaire indicated that all participants did not significantly favor the 3‐D system.Conclusion: We believe that the 3‐D camera system can allow young surgeons to perform standard laparoscopic tasks safely and quickly, so as to accelerate the learning curve. However, new‐generation 3‐D systems will be essential to overcome surgeons' discomfort.
- 11 April 2014
- Published by Springer Nature in Hernia
- Vol. 19 (3) , 401-405
A comparative study of single incision versus conventional laparoscopic inguinal hernia repair
Over the past years, safety and feasibility of conventional laparoscopic inguinal hernia repair was well established. However, conventional laparoscopic hernia repair (CL) usually requires three working ports ranging from 5 to 10 mm, and each increasing port is associated with possible increasing morbidity and pain related to ports. This has led to the development of single incision laparoscopic hernia repair (SIL) which can further reduce the port-related morbidities and improve cosmetic outcomes. The aim of the study was to evaluate the safety and feasibility of SIL using both transabdominal preperitoneal (TAPP) and totally preperitoneal (TEP) approaches and compare the patients’ wound satisfaction between the two groups. This is a retrospective review of prospectively collected data. We analyzed the results of patients who underwent either CL or SIL for inguinal hernia between January 2011 and July 2012 in Pamela Youde Nethersole Eastern Hospital. Patients’ demographic details, type of hernia, operative time, mesh used, and post-operative complications were compared. A telephone survey was also conducted to evaluate patients’ subjective wound satisfaction. In total, 32 SIL and 35 CL procedures were performed in this period. The two groups were matched for age, sex, type of hernia and ASA grading. The mean operative time was significantly shorter in the CL group (52.6 vs. 62.6 min, p = 0.02). All SIL procedures were completed successfully without conversion to CL or open repair and post-operative complications such as wound infection, seroma, recurrence and chronic pain were also comparable between the two groups. As for the telephone survey, SIL groups’ wound is less obvious and less detectable by others as compared to CL, but on the whole both groups of patients are very satisfied with the wound outcomes. All the SIL groups would continue with their decision on SIL and 60 % of CL group would choose SIL if they had to go back in time. Our results have shown that in experienced hands, SIL is feasible and as safe as CL. Further randomized trials should be performed to evaluate the clinical application of single incision TEP and TAPP.
- 11 April 2014
- Published by Springer Nature in Hernia
- Vol. 19 (3) , 401-405
A comparative study of single incision versus conventional laparoscopic inguinal hernia repair
Over the past years, safety and feasibility of conventional laparoscopic inguinal hernia repair was well established. However, conventional laparoscopic hernia repair (CL) usually requires three working ports ranging from 5 to 10 mm, and each increasing port is associated with possible increasing morbidity and pain related to ports. This has led to the development of single incision laparoscopic hernia repair (SIL) which can further reduce the port-related morbidities and improve cosmetic outcomes. The aim of the study was to evaluate the safety and feasibility of SIL using both transabdominal preperitoneal (TAPP) and totally preperitoneal (TEP) approaches and compare the patients’ wound satisfaction between the two groups. This is a retrospective review of prospectively collected data. We analyzed the results of patients who underwent either CL or SIL for inguinal hernia between January 2011 and July 2012 in Pamela Youde Nethersole Eastern Hospital. Patients’ demographic details, type of hernia, operative time, mesh used, and post-operative complications were compared. A telephone survey was also conducted to evaluate patients’ subjective wound satisfaction. In total, 32 SIL and 35 CL procedures were performed in this period. The two groups were matched for age, sex, type of hernia and ASA grading. The mean operative time was significantly shorter in the CL group (52.6 vs. 62.6 min, p = 0.02). All SIL procedures were completed successfully without conversion to CL or open repair and post-operative complications such as wound infection, seroma, recurrence and chronic pain were also comparable between the two groups. As for the telephone survey, SIL groups’ wound is less obvious and less detectable by others as compared to CL, but on the whole both groups of patients are very satisfied with the wound outcomes. All the SIL groups would continue with their decision on SIL and 60 % of CL group would choose SIL if they had to go back in time. Our results have shown that in experienced hands, SIL is feasible and as safe as CL. Further randomized trials should be performed to evaluate the clinical application of single incision TEP and TAPP.
- 22 April 2013
- Published by Wiley in Asian Journal of Endoscopic Surgery
- Vol. 6 (2) , 78-81
Endo‐laparoscopic approach versus conventional open surgery in the treatment of obstructing left‐sided colon cancer: Long‐term follow‐up of a randomized trial
Introduction: We previously conducted a randomized trial comparing the endo‐laparoscopic approach (i.e. placing self‐expanding metallic stents followed by laparoscopic resection) and conventional open surgery in the treatment of obstructing left‐sided colon cancer. This study is a follow‐up of the previous randomized trial and aims to report the long‐term outcomes of the two groups.Methods: Forty‐eight patients from the randomized trial were followed up in an outpatient clinic with regular monitoring. Patients were compared for clinicopathological variables, disease recurrence and survival rates.Results: Clinicopathological details were comparable between the two groups. During the median follow‐up periods of 32 months for the open group and 65 months endo‐laparoscopic group, no statistically significant difference was observed between the groups in disease recurrence rate, 5‐year overall survival (27% vs 48%, P = 0.076) and 5‐year disease‐free survival rates (48% vs 52%, P = 0.63).Conclusion: Besides being a safe bridge to subsequent elective laparoscopic surgery, preoperative self‐expanding metallic stents insertion does not adversely affect oncological outcomes and patient survival. Based on our data, the endo‐laparoscopic approach is the treatment of choice for patients presenting with malignant left‐sided colonic obstruction.
- 22 April 2013
- Published by Wiley in Asian Journal of Endoscopic Surgery
- Vol. 6 (2) , 78-81
Endo‐laparoscopic approach versus conventional open surgery in the treatment of obstructing left‐sided colon cancer: Long‐term follow‐up of a randomized trial
Introduction: We previously conducted a randomized trial comparing the endo‐laparoscopic approach (i.e. placing self‐expanding metallic stents followed by laparoscopic resection) and conventional open surgery in the treatment of obstructing left‐sided colon cancer. This study is a follow‐up of the previous randomized trial and aims to report the long‐term outcomes of the two groups.Methods: Forty‐eight patients from the randomized trial were followed up in an outpatient clinic with regular monitoring. Patients were compared for clinicopathological variables, disease recurrence and survival rates.Results: Clinicopathological details were comparable between the two groups. During the median follow‐up periods of 32 months for the open group and 65 months endo‐laparoscopic group, no statistically significant difference was observed between the groups in disease recurrence rate, 5‐year overall survival (27% vs 48%, P = 0.076) and 5‐year disease‐free survival rates (48% vs 52%, P = 0.63).Conclusion: Besides being a safe bridge to subsequent elective laparoscopic surgery, preoperative self‐expanding metallic stents insertion does not adversely affect oncological outcomes and patient survival. Based on our data, the endo‐laparoscopic approach is the treatment of choice for patients presenting with malignant left‐sided colonic obstruction.
- 1 February 2013
- Published by Wolters Kluwer Health in Surgical Laparoscopy, Endoscopy & Percutaneous Techniques
- Vol. 23 (1) , e17-e21
Robot-assisted Laparoscopic Approach of Management for Mirizzi Syndrome
Mirizzi syndrome is an uncommon cause of common hepatic duct obstruction resulting from gallstone impaction in the cystic duct or gallbladder neck. Mirizzi syndrome is traditionally considered as a contraindication to laparoscopic surgery mainly due to risk of bile duct injury during dissection. We present the surgical experience of 5 patients with Mirizzi syndrome who were diagnosed preoperatively and managed using minimally access surgical technique, either total laparoscopic or robotic-assisted laparoscopic approach. All patients had successful operations and recovered without complications. We concluded that with a correct preoperative diagnosis, careful operative strategy, increasing expertise with laparoscopic technique, and introduction of robotic surgical system, minimally invasive approach of management of Mirizzi syndrome becomes safe and feasible.
- 1 February 2013
- Published by Wolters Kluwer Health in Surgical Laparoscopy, Endoscopy & Percutaneous Techniques
- Vol. 23 (1) , e17-e21
Robot-assisted Laparoscopic Approach of Management for Mirizzi Syndrome
Mirizzi syndrome is an uncommon cause of common hepatic duct obstruction resulting from gallstone impaction in the cystic duct or gallbladder neck. Mirizzi syndrome is traditionally considered as a contraindication to laparoscopic surgery mainly due to risk of bile duct injury during dissection. We present the surgical experience of 5 patients with Mirizzi syndrome who were diagnosed preoperatively and managed using minimally access surgical technique, either total laparoscopic or robotic-assisted laparoscopic approach. All patients had successful operations and recovered without complications. We concluded that with a correct preoperative diagnosis, careful operative strategy, increasing expertise with laparoscopic technique, and introduction of robotic surgical system, minimally invasive approach of management of Mirizzi syndrome becomes safe and feasible.