Chuanyong Bai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chuanyong Bai has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Richard Conwell
Digirad Corporation, Poway, CA, USA
4 shared publicationsJoel Kindem
3 shared publicationsJamshid Maddahi
Department of Molecular and Medical Pharmacology (Nuclear Medicine) and Medicine (Cardiology), UCLA—David Geffen School of Medicine, Los Angeles, USA
2 shared publicationsRex Old
Digirad Corporation, Poway, USA
2 shared publicationsHetal Babla
Digirad Corporation, Poway, USA
1 shared publication- Michael Gurley
Digirad Corporation, Poway, USA
1 shared publication
Latest Publications
- 23 September 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 58 (5) , 2198-2204
New Daily Detector Uniformity Quality Control Methodology for Cardiac SPECT Using Solid-State Detectors
Detector non-uniformity can potentially introduce detectable artifacts into SPECT images. The degree of the non-uniformity and the extent and position of the non-uniform area on the detector surface determine the position and severity of the introduced artifacts. The commonly used daily uniformity quality control (QC) procedure follows the NEMA methodology but acquires fewer counts than the latter specifies. It has three major drawbacks: (1) it does not report the locations and extent of the non-uniform areas on the detector surface; (2) it may report a non-uniformity value that is lower than the true value due to the use of a 9-point filter, and it makes the reported non-uniformity value vary with the extent of the non-uniform area. These two drawbacks are inherited from the NEMA methodology. The third drawback is that the noise due to the relatively low counts collected in daily uniformity QC does not allow the measurement of certain degrees of non-uniformity with adequate statistical significance, yet such non-uniformity can potentially introduce observable artifacts. In this work we propose a new methodology for daily uniformity QC for cardiac SPECT imaging using solid-state detectors. The new QC procedure (1) reports the locations and extents of the non-uniform areas of the detectors and (2) can catch some detectors that pass the NEMA-based daily uniformity QC but are non-uniform enough to introduce detectable artifacts.
- 23 September 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 58 (5) , 2198-2204
New Daily Detector Uniformity Quality Control Methodology for Cardiac SPECT Using Solid-State Detectors
Detector non-uniformity can potentially introduce detectable artifacts into SPECT images. The degree of the non-uniformity and the extent and position of the non-uniform area on the detector surface determine the position and severity of the introduced artifacts. The commonly used daily uniformity quality control (QC) procedure follows the NEMA methodology but acquires fewer counts than the latter specifies. It has three major drawbacks: (1) it does not report the locations and extent of the non-uniform areas on the detector surface; (2) it may report a non-uniformity value that is lower than the true value due to the use of a 9-point filter, and it makes the reported non-uniformity value vary with the extent of the non-uniform area. These two drawbacks are inherited from the NEMA methodology. The third drawback is that the noise due to the relatively low counts collected in daily uniformity QC does not allow the measurement of certain degrees of non-uniformity with adequate statistical significance, yet such non-uniformity can potentially introduce observable artifacts. In this work we propose a new methodology for daily uniformity QC for cardiac SPECT imaging using solid-state detectors. The new QC procedure (1) reports the locations and extents of the non-uniform areas of the detectors and (2) can catch some detectors that pass the NEMA-based daily uniformity QC but are non-uniform enough to introduce detectable artifacts.
- 20 May 2010
- Published by Wiley in Medical Physics
- Vol. 37 (6Part1) , 2796-2803
A randomization approach to handling data scaling in nuclear medicine
In medical imaging, data scaling is sometimes desired to handle the system complexity, such as uniformity calibration. Since the data are usually saved in short integer, conventional data scaling will first scale the data in floating point format and then truncate or round the floating point data to short integer data. For example, when using truncation, scaling of 9 by 1.1 results in 9 and scaling of 10 by 1.1 results in 11. When the count level is low, such scaling may change the local data distribution and affect the intended application of the data.In this work, the authors use an example gated cardiac SPECT study to illustrate the effect of conventional scaling by factors of 1.1 and 1.2. The authors then scaled the data with the same scaling factors using a randomization approach, in which a random number evenly distributed between 0 and 1 is generated to determine how the floating point data will be saved as short integer data. If the random number is between 0 and 0.9, then 9.9 will be saved as 10, otherwise 9. In other words, the floating point value 9.9 will be saved in short integer value as 10 with 90% probability or 9 with 10% probability. For statistical analysis of the performance, the authors applied the conventional approach with rounding and the randomization approach to 50 consecutive gated studies from a clinical site.For the example study, the image reconstructed from the original data showed an apparent perfusion defect at the apex of the myocardium. The defect size was noticeably changed by scaling with 1.1 and 1.2 using the conventional approaches with truncation and rounding. Using the randomization approach, in contrast, the images from the scaled data appeared identical to the original image. Line profile analysis of the scaled data showed that the randomization approach introduced the least change to the data as compared to the conventional approaches. For the 50 gated data sets, significantly more studies showed quantitative differences between the original images and the images from the data scaled by 1.2 using the rounding approach than the randomization approach [46/50 (92%) versus 3/50 (6%), p < 0.05]. Likewise, significantly more studies showed visually noticeable differences between the original images and the images from the data scaled by 1.2 using the rounding approach than randomization [29/50 (58%) versus 1/50 (2%), p < 0.05].In conclusion, the proposed randomization approach minimizes the scaling-introduced local data change as compared to the conventional approaches. It is preferred for nuclear medicine data scaling.
- 20 May 2010
- Published by Wiley in Medical Physics
- Vol. 37 (6Part1) , 2796-2803
A randomization approach to handling data scaling in nuclear medicine
In medical imaging, data scaling is sometimes desired to handle the system complexity, such as uniformity calibration. Since the data are usually saved in short integer, conventional data scaling will first scale the data in floating point format and then truncate or round the floating point data to short integer data. For example, when using truncation, scaling of 9 by 1.1 results in 9 and scaling of 10 by 1.1 results in 11. When the count level is low, such scaling may change the local data distribution and affect the intended application of the data.In this work, the authors use an example gated cardiac SPECT study to illustrate the effect of conventional scaling by factors of 1.1 and 1.2. The authors then scaled the data with the same scaling factors using a randomization approach, in which a random number evenly distributed between 0 and 1 is generated to determine how the floating point data will be saved as short integer data. If the random number is between 0 and 0.9, then 9.9 will be saved as 10, otherwise 9. In other words, the floating point value 9.9 will be saved in short integer value as 10 with 90% probability or 9 with 10% probability. For statistical analysis of the performance, the authors applied the conventional approach with rounding and the randomization approach to 50 consecutive gated studies from a clinical site.For the example study, the image reconstructed from the original data showed an apparent perfusion defect at the apex of the myocardium. The defect size was noticeably changed by scaling with 1.1 and 1.2 using the conventional approaches with truncation and rounding. Using the randomization approach, in contrast, the images from the scaled data appeared identical to the original image. Line profile analysis of the scaled data showed that the randomization approach introduced the least change to the data as compared to the conventional approaches. For the 50 gated data sets, significantly more studies showed quantitative differences between the original images and the images from the data scaled by 1.2 using the rounding approach than the randomization approach [46/50 (92%) versus 3/50 (6%), p < 0.05]. Likewise, significantly more studies showed visually noticeable differences between the original images and the images from the data scaled by 1.2 using the rounding approach than randomization [29/50 (58%) versus 1/50 (2%), p < 0.05].In conclusion, the proposed randomization approach minimizes the scaling-introduced local data change as compared to the conventional approaches. It is preferred for nuclear medicine data scaling.
- Open Access
- 19 February 2010
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 17 (3) , 459-469
Phantom evaluation of a cardiac SPECT/VCT system that uses a common set of solid-state detectors for both emission and transmission scans
- 19 February 2010
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 17 (3) , 459-469
Open AccessPhantom evaluation of a cardiac SPECT/VCT system that uses a common set of solid-state detectors for both emission and transmission scans
- Open Access
- 2 June 2009
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 16 (4) , 580-589
Development and evaluation of a new fully automatic motion detection and correction technique in cardiac SPECT imaging
- 2 June 2009
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 16 (4) , 580-589
Open AccessDevelopment and evaluation of a new fully automatic motion detection and correction technique in cardiac SPECT imaging