H Christina Fan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
H Christina Fan has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Paul C. Blainey
Massachusetts Institute of Technology
2 shared publications - Stephen R. Quake
Stanford University
2 shared publications - Richard A WhiteIII
Department of Bioengineering at Stanford University and Howard Hughes Medical Institute, Stanford, California 94305, USA
1 shared publication - Richard Allen White
North Carolina Research Center (NCRC), Department of Bioinformatics and Genomics, The University of North Carolina at Charlotte
1 shared publication
Latest Publications
- Open Access
- 19 November 2009
- Published by Springer Nature in BMC Genomics
- Vol. 10 (1) , 541
Erratum to: Digital PCR provides sensitive and absolute calibration for high throughput sequencing
- 19 November 2009
- Published by Springer Nature in BMC Genomics
- Vol. 10 (1) , 541
Open AccessErratum to: Digital PCR provides sensitive and absolute calibration for high throughput sequencing
- Open Access
- 19 March 2009
- Published by Springer Nature in BMC Genomics
- Vol. 10 (1) , 116
Digital PCR provides sensitive and absolute calibration for high throughput sequencing
Background: Next-generation DNA sequencing on the 454, Solexa, and SOLiD platforms requires absolute calibration of the number of molecules to be sequenced. This requirement has two unfavorable consequences. First, large amounts of sample-typically micrograms-are needed for library preparation, thereby limiting the scope of samples which can be sequenced. For many applications, including metagenomics and the sequencing of ancient, forensic, and clinical samples, the quantity of input DNA can be critically limiting. Second, each library requires a titration sequencing run, thereby increasing the cost and lowering the throughput of sequencing. Results: We demonstrate the use of digital PCR to accurately quantify 454 and Solexa sequencing libraries, enabling the preparation of sequencing libraries from nanogram quantities of input material while eliminating costly and time-consuming titration runs of the sequencer. We successfully sequenced low-nanogram scale bacterial and mammalian DNA samples on the 454 FLX and Solexa DNA sequencing platforms. This study is the first to definitively demonstrate the successful sequencing of picogram quantities of input DNA on the 454 platform, reducing the sample requirement more than 1000-fold without pre-amplification and the associated bias and reduction in library depth. Conclusion: The digital PCR assay allows absolute quantification of sequencing libraries, eliminates uncertainties associated with the construction and application of standard curves to PCR-based quantification, and with a coefficient of variation close to 10%, is sufficiently precise to enable direct sequencing without titration runs.
- 19 March 2009
- Published by Springer Nature in BMC Genomics
- Vol. 10 (1) , 116
Open AccessDigital PCR provides sensitive and absolute calibration for high throughput sequencing
Background: Next-generation DNA sequencing on the 454, Solexa, and SOLiD platforms requires absolute calibration of the number of molecules to be sequenced. This requirement has two unfavorable consequences. First, large amounts of sample-typically micrograms-are needed for library preparation, thereby limiting the scope of samples which can be sequenced. For many applications, including metagenomics and the sequencing of ancient, forensic, and clinical samples, the quantity of input DNA can be critically limiting. Second, each library requires a titration sequencing run, thereby increasing the cost and lowering the throughput of sequencing. Results: We demonstrate the use of digital PCR to accurately quantify 454 and Solexa sequencing libraries, enabling the preparation of sequencing libraries from nanogram quantities of input material while eliminating costly and time-consuming titration runs of the sequencer. We successfully sequenced low-nanogram scale bacterial and mammalian DNA samples on the 454 FLX and Solexa DNA sequencing platforms. This study is the first to definitively demonstrate the successful sequencing of picogram quantities of input DNA on the 454 platform, reducing the sample requirement more than 1000-fold without pre-amplification and the associated bias and reduction in library depth. Conclusion: The digital PCR assay allows absolute quantification of sequencing libraries, eliminates uncertainties associated with the construction and application of standard curves to PCR-based quantification, and with a coefficient of variation close to 10%, is sufficiently precise to enable direct sequencing without titration runs.