Sen Bai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Sen Bai has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Jin Wang
Department of Thoracic Oncology and State Key Laboratory of Biotherapy, Cancer Center, West China Hospital, Sichuan University, Chengdu, 610041, P.R. China
4 shared publications - Youling Gong
Department of Thoracic Oncology and State Key Laboratory of Biotherapy, Cancer Center, West China Hospital, Sichuan University, Chengdu, 610041, P.R. China
3 shared publications - Feng Xu
Sichuan Univ, West China Hosp, Lung Canc Ctr, Chengdu, Peoples R China
2 shared publications - Qingfeng Xu
Radiation Physics Center, Cancer Center, West China Hospital, Sichuan University, Chengdu, 610041, P.R. China
2 shared publications - Xiaoqin Jiang
Department of Radiation Oncology, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, PR China
2 shared publications - Yongmei Liu
Division of Thoracic Tumor Multimodality Treatment, Cancer Center, West China Hospital, Sichuan University, Chengdu, China
2 shared publications
Latest Publications
- Open Access
- 26 September 2014
- Published by Springer Nature in BMC Cancer
- Vol. 14 (1) , 719
Stereotactic body radiation therapy for post-pulmonary lobectomy isolated lung metastasis of thoracic tumor: survival and side effects
Stereotactic body radiation therapy (SBRT) has emerged as an alternative treatment for patients with early stage non-small cell lung cancer (NSCLC) or metastatic pulmonary tumors. However, for isolated lung metastasis (ILM) of thoracic malignances after pulmonary lobectomy, reported outcomes of SBRT have been limited. This study evaluates the role of SBRT in the treatment of such patients. A retrospective search of the SBRT database was conducted in three hospitals. The parameters analyzed in the treated patients were local control, progression-free survival (PFS), overall survival (OS), and the treatment-related side-effects. In total, 23 patients with single ILM after pulmonary lobectomy treated with SBRT were identified and the median follow-up time was 14 months (range: 6.0-47.0 months). Local recurrences were observed in two patients during follow-up and the 1-year local control rate was 91.3%. Median PFS and OS for the studied cohort were 10.0 months [95% confidence interval (CI) 5.1-14.9 months] and 21.0 months (95% CI 11.4-30.6 months), respectively. Acute radiation pneumonitis (RP) of grade 2 or worse was observed in five (21.7%) and three (13.0%) patients, respectively. Other treatment-related toxicities included chest wall pain in one patient (4.3%) and acute esophagitis in two patients (8.7%). By Pearson correlation analysis, the planning target volume (PTV) volume and the volume of the ipsilateral lung exposed to a minimum dose of 5 Gy (IpV5) were significantly related to the acute RP of grade 2 or worse in present study (p < 0.05). The optimal thresholds of the PTV and IpV5 to predict RP of acute grade 2 or worse RP were 59 cm3 and 51% respectively, according to the receiver-operating characteristics curve analysis, with sensitivity/specificity of 75.0%/80.0% and 62.5%/80.0%. SBRT for post-lobectomy ILM was effective and well tolerated. The major reason for disease progression was distant failure but not local recurrence. The PTV and IpV5 are potential predictors of acute RP of grade 2 or higher and should be considered in treatment planning for such patients.
- 26 September 2014
- Published by Springer Nature in BMC Cancer
- Vol. 14 (1) , 719
Open AccessStereotactic body radiation therapy for post-pulmonary lobectomy isolated lung metastasis of thoracic tumor: survival and side effects
Stereotactic body radiation therapy (SBRT) has emerged as an alternative treatment for patients with early stage non-small cell lung cancer (NSCLC) or metastatic pulmonary tumors. However, for isolated lung metastasis (ILM) of thoracic malignances after pulmonary lobectomy, reported outcomes of SBRT have been limited. This study evaluates the role of SBRT in the treatment of such patients. A retrospective search of the SBRT database was conducted in three hospitals. The parameters analyzed in the treated patients were local control, progression-free survival (PFS), overall survival (OS), and the treatment-related side-effects. In total, 23 patients with single ILM after pulmonary lobectomy treated with SBRT were identified and the median follow-up time was 14 months (range: 6.0-47.0 months). Local recurrences were observed in two patients during follow-up and the 1-year local control rate was 91.3%. Median PFS and OS for the studied cohort were 10.0 months [95% confidence interval (CI) 5.1-14.9 months] and 21.0 months (95% CI 11.4-30.6 months), respectively. Acute radiation pneumonitis (RP) of grade 2 or worse was observed in five (21.7%) and three (13.0%) patients, respectively. Other treatment-related toxicities included chest wall pain in one patient (4.3%) and acute esophagitis in two patients (8.7%). By Pearson correlation analysis, the planning target volume (PTV) volume and the volume of the ipsilateral lung exposed to a minimum dose of 5 Gy (IpV5) were significantly related to the acute RP of grade 2 or worse in present study (p < 0.05). The optimal thresholds of the PTV and IpV5 to predict RP of acute grade 2 or worse RP were 59 cm3 and 51% respectively, according to the receiver-operating characteristics curve analysis, with sensitivity/specificity of 75.0%/80.0% and 62.5%/80.0%. SBRT for post-lobectomy ILM was effective and well tolerated. The major reason for disease progression was distant failure but not local recurrence. The PTV and IpV5 are potential predictors of acute RP of grade 2 or higher and should be considered in treatment planning for such patients.
- Open Access
- 15 July 2010
- Published by Springer Nature in Radiation Oncology
- Vol. 5 (1) , 65
Dosimetric comparison using different multileaf collimeters in intensity-modulated radiotherapy for upper thoracic esophageal cancer
Purpose: To study the impacts of multileaf collimators (MLC) width [standard MLC width of 10 mm (sMLC) and micro-MLC width of 4 mm (mMLC)] in the intensity-modulated radiotherapy (IMRT) planning for the upper thoracic esophageal cancer (UTEC). Methods and materials: 10 patients with UTEC were retrospectively planned with the sMLC and the mMLC. The monitor unites (MUs) and dose volume histogram-based parameters [conformity index (CI) and homogeneous index (HI)] were compared between the IMRT plans with sMLC and with mMLC. Results: The IMRT plans with the mMLC were more efficient (average MUs: 703.1 ± 68.3) than plans with the sMLC (average MUs: 833.4 ± 73.8) (p < 0.05). Also, compared to plans with the sMLC, the plans with the mMLC showed advantages in dose coverage of the planning gross tumor volume (Pgtv) (CI 0.706 ± 0.056/HI 1.093 ± 0.021) and the planning target volume (PTV) (CI 0.707 ± 0.029/HI 1.315 ± 0.013) (p < 0.05). In addition, the significant dose sparing in the D5 (3260.3 ± 374.0 vs 3404.5 ± 374.4)/gEUD (1815.1 ± 281.7 vs 1849.2 ± 297.6) of the spinal cord, the V10 (33.2 ± 6.5 vs 34.0 ± 6.7), V20 (16.0 ± 4.6 vs 16.6 ± 4.7), MLD (866.2 ± 174.1 vs 887.9 ± 172.1) and gEUD (938.6 ± 175.2 vs 956.8 ± 171.0) of the lungs were observed in the plans with the mMLC, respectively (p < 0.05). Conclusions: Comparing to the sMLC, the mMLC not only demonstrated higher efficiencies and more optimal target coverage, but also considerably improved the dose sparing of OARs in the IMRT planning for UTEC.
- 15 July 2010
- Published by Springer Nature in Radiation Oncology
- Vol. 5 (1) , 65
Open AccessDosimetric comparison using different multileaf collimeters in intensity-modulated radiotherapy for upper thoracic esophageal cancer
Purpose: To study the impacts of multileaf collimators (MLC) width [standard MLC width of 10 mm (sMLC) and micro-MLC width of 4 mm (mMLC)] in the intensity-modulated radiotherapy (IMRT) planning for the upper thoracic esophageal cancer (UTEC). Methods and materials: 10 patients with UTEC were retrospectively planned with the sMLC and the mMLC. The monitor unites (MUs) and dose volume histogram-based parameters [conformity index (CI) and homogeneous index (HI)] were compared between the IMRT plans with sMLC and with mMLC. Results: The IMRT plans with the mMLC were more efficient (average MUs: 703.1 ± 68.3) than plans with the sMLC (average MUs: 833.4 ± 73.8) (p < 0.05). Also, compared to plans with the sMLC, the plans with the mMLC showed advantages in dose coverage of the planning gross tumor volume (Pgtv) (CI 0.706 ± 0.056/HI 1.093 ± 0.021) and the planning target volume (PTV) (CI 0.707 ± 0.029/HI 1.315 ± 0.013) (p < 0.05). In addition, the significant dose sparing in the D5 (3260.3 ± 374.0 vs 3404.5 ± 374.4)/gEUD (1815.1 ± 281.7 vs 1849.2 ± 297.6) of the spinal cord, the V10 (33.2 ± 6.5 vs 34.0 ± 6.7), V20 (16.0 ± 4.6 vs 16.6 ± 4.7), MLD (866.2 ± 174.1 vs 887.9 ± 172.1) and gEUD (938.6 ± 175.2 vs 956.8 ± 171.0) of the lungs were observed in the plans with the mMLC, respectively (p < 0.05). Conclusions: Comparing to the sMLC, the mMLC not only demonstrated higher efficiencies and more optimal target coverage, but also considerably improved the dose sparing of OARs in the IMRT planning for UTEC.
- Open Access
- 27 February 2010
- Published by Springer Nature in Radiation Oncology
- Vol. 5 (1) , 19
Hypofractionated radiotherapy for lung tumors with online cone beam CT guidance and active breathing control
Background: To study the set-up errors, PTV margin and toxicity of cone beam CT (CBCT) guided hypofractionated radiotherapy with active breathing control (ABC) for patients with non-small cell lung cancer (NSCLC) or metastatic tumors in lung. Methods: 32 tumors in 20 patients were treated. Based on the location of tumor, dose per fraction given to tumor was divided into three groups: 12 Gy, 8 Gy and 6 Gy. ABC is applied for every patient. During each treatment, patients receive CBCT scan for online set-up correction. The pre- and post-correction setup errors between fractions, the interfractional and intrafractional, set-up errors, PTV margin as well as toxicity are analyzed. Results: The pre-correction systematic and random errors in the left-right (LR), superior-inferior (SI), anterior-posterior (AP) directions were 3.7 mm and 5.3 mm, 3.1 mm and 2.1 mm, 3.7 mm and 2.8 mm, respectively, while the post-correction residual errors were 0.6 mm and 0.8 mm, 0.8 mm and 0.8 mm, 1.2 mm and 1.3 mm, respectively. There was an obvious intrafractional shift of tumor position. The pre-correction PTV margin was 9.5 mm in LR, 14.1 mm in SI and 8.2 mm in AP direction. After CBCT guided online correction, the PTV margin was markedly reduced in all three directions. The post-correction margins ranged 1.5 to 2.1 mm. The treatment was well tolerated by patients, of whom there were 4 (20%) grade1-2 acute pneumonitis, 3 (15%) grade1 acute esophagitis, 2 (10%) grade1 late pneumonitis and 1 (5%) grade 1 late esophagitis. Conclusion: The positioning errors for lung SBRT using ABC were significant. Online correction with CBCT image guidance should be applied to reduce setup errors and PTV margin, which may reduce radiotherapy toxicity of tissues when ABC was used.
- 27 February 2010
- Published by Springer Nature in Radiation Oncology
- Vol. 5 (1) , 19
Open AccessHypofractionated radiotherapy for lung tumors with online cone beam CT guidance and active breathing control
Background: To study the set-up errors, PTV margin and toxicity of cone beam CT (CBCT) guided hypofractionated radiotherapy with active breathing control (ABC) for patients with non-small cell lung cancer (NSCLC) or metastatic tumors in lung. Methods: 32 tumors in 20 patients were treated. Based on the location of tumor, dose per fraction given to tumor was divided into three groups: 12 Gy, 8 Gy and 6 Gy. ABC is applied for every patient. During each treatment, patients receive CBCT scan for online set-up correction. The pre- and post-correction setup errors between fractions, the interfractional and intrafractional, set-up errors, PTV margin as well as toxicity are analyzed. Results: The pre-correction systematic and random errors in the left-right (LR), superior-inferior (SI), anterior-posterior (AP) directions were 3.7 mm and 5.3 mm, 3.1 mm and 2.1 mm, 3.7 mm and 2.8 mm, respectively, while the post-correction residual errors were 0.6 mm and 0.8 mm, 0.8 mm and 0.8 mm, 1.2 mm and 1.3 mm, respectively. There was an obvious intrafractional shift of tumor position. The pre-correction PTV margin was 9.5 mm in LR, 14.1 mm in SI and 8.2 mm in AP direction. After CBCT guided online correction, the PTV margin was markedly reduced in all three directions. The post-correction margins ranged 1.5 to 2.1 mm. The treatment was well tolerated by patients, of whom there were 4 (20%) grade1-2 acute pneumonitis, 3 (15%) grade1 acute esophagitis, 2 (10%) grade1 late pneumonitis and 1 (5%) grade 1 late esophagitis. Conclusion: The positioning errors for lung SBRT using ABC were significant. Online correction with CBCT image guidance should be applied to reduce setup errors and PTV margin, which may reduce radiotherapy toxicity of tissues when ABC was used.
- Open Access
- 8 October 2009
- Published by Springer Nature in Journal of Experimental & Clinical Cancer Research
- Vol. 28 (1) , 136
In vivo99mTc-HYNIC-annexin V imaging of early tumor apoptosis in mice after single dose irradiation
Background: Apoptosis is a major mode of hematological tumor death after radiation. Early detection of apoptosis may be beneficial for cancer adaptive treatment. 99mTc-HYNIC-annexinV has been reported as a promising agent for in vivo apoptosis imaging. The purpose of this study is to evaluate the feasibility of in vivo99mTc-HYNIC-annexinV imaging of radiation- induced apoptosis, and to investigate its correlation with radiosensitivity. Methods: Ten days after inoculation of tumor cells in the right upper limbs, the mice were randomly divided into two groups. The imaging group (4 mice each level, 4 dose levels) was injected with 4-8 MBq 99mTc-HYNIC-annexinV 24 hours after irradiation and imaged 1 hr post-injection, and the mice were sacrificed immediately after imaging for biodistribution analysis of annexin V. The observation group (4 mice each level, 2 dose levels) was only observed for tumor regression post-radiation. The number of apoptotic cells in a tumor was estimated with TUNEL assay. Results: The 99mTc-HYNIC-annexin V uptake in E14 lymphoma significantly increased as the radiation dose escalated from 0 to 8 Gy, and significantly correlated with the number of TUNEL-positive cells (r = 0.892, P < 0.001). The Annexin-V uptake and the number of TUNEL-positive cells in El4 lymphoma were significantly greater than those in S180 sarcoma. With 8 Gy, S180 sarcoma tumor showed scanty apoptosis and less shrinkage while El4 lymphoma showed remarkable apoptosis and complete remission. Conclusion: 99mTc-HYNIC-annexinV in vivo imaging is a feasible method to detect early radiation-induced apoptosis in different tumors, and might be predictive for radiation sensitivity.
- 8 October 2009
- Published by Springer Nature in Journal of Experimental & Clinical Cancer Research
- Vol. 28 (1) , 136
Open AccessIn vivo99mTc-HYNIC-annexin V imaging of early tumor apoptosis in mice after single dose irradiation
Background: Apoptosis is a major mode of hematological tumor death after radiation. Early detection of apoptosis may be beneficial for cancer adaptive treatment. 99mTc-HYNIC-annexinV has been reported as a promising agent for in vivo apoptosis imaging. The purpose of this study is to evaluate the feasibility of in vivo99mTc-HYNIC-annexinV imaging of radiation- induced apoptosis, and to investigate its correlation with radiosensitivity. Methods: Ten days after inoculation of tumor cells in the right upper limbs, the mice were randomly divided into two groups. The imaging group (4 mice each level, 4 dose levels) was injected with 4-8 MBq 99mTc-HYNIC-annexinV 24 hours after irradiation and imaged 1 hr post-injection, and the mice were sacrificed immediately after imaging for biodistribution analysis of annexin V. The observation group (4 mice each level, 2 dose levels) was only observed for tumor regression post-radiation. The number of apoptotic cells in a tumor was estimated with TUNEL assay. Results: The 99mTc-HYNIC-annexin V uptake in E14 lymphoma significantly increased as the radiation dose escalated from 0 to 8 Gy, and significantly correlated with the number of TUNEL-positive cells (r = 0.892, P < 0.001). The Annexin-V uptake and the number of TUNEL-positive cells in El4 lymphoma were significantly greater than those in S180 sarcoma. With 8 Gy, S180 sarcoma tumor showed scanty apoptosis and less shrinkage while El4 lymphoma showed remarkable apoptosis and complete remission. Conclusion: 99mTc-HYNIC-annexinV in vivo imaging is a feasible method to detect early radiation-induced apoptosis in different tumors, and might be predictive for radiation sensitivity.
- Open Access
- 22 April 2008
- Published by Springer Nature in Radiation Oncology
- Vol. 3 (1) , 11
Conventionally-fractionated image-guided intensity modulated radiotherapy (IG-IMRT): a safe and effective treatment for cancer spinal metastasis
Background: Treatments for cancer spinal metastasis were always palliative. This study was conducted to investigate the safety and effectiveness of IG-IMRT for these patients. Methods: 10 metastatic lesions were treated with conventionally-fractionated IG-IMRT. Daily kilovoltage cone-beam computed tomography (kV-CBCT) scan was applied to ensure accurate positioning. Plans were evaluated by the dose-volume histogram (DVH) analysis. Results: Before set-up correction, the positioning errors in the left-right (LR), superior-inferior (SI) and anterior-posterior (AP) axes were 0.3 ± 3.2, 0.4 ± 4.5 and -0.2 ± 3.9 mm, respectively. After repositioning, those errors were 0.1 ± 0.7, 0 ± 0.8 and 0 ± 0.7 mm, respectively. The systematic/random uncertainties ranged 1.4–2.3/3.0–4.1 before and 0.1–0.2/0.7–0.8 mm after online set-up correction. In the original IMRT plans, the average dose of the planning target volume (PTV) was 61.9 Gy, with the spinal cord dose less than 49 Gy. Compared to the simulated PTVs based on the pre-correction CBCT, the average volume reduction of PTVs was 42.3% after online correction. Also, organ at risk (OAR) all benefited from CBCT-based set-up correction and had significant dose reduction with IGRT technique. Clinically, most patients had prompt pain relief within one month of treatment. There was no radiation-induced toxicity detected clinically during a median follow-up of 15.6 months. Conclusion: IG-IMRT provides a new approach to treat cancer spinal metastasis. The precise positioning ensures the implementation of optimal IMRT plan, satisfying both the dose escalation of tumor targets and the radiation tolerance of spinal cord. It might benefit the cancer patient with spinal metastasis.
- 22 April 2008
- Published by Springer Nature in Radiation Oncology
- Vol. 3 (1) , 11
Open AccessConventionally-fractionated image-guided intensity modulated radiotherapy (IG-IMRT): a safe and effective treatment for cancer spinal metastasis
Background: Treatments for cancer spinal metastasis were always palliative. This study was conducted to investigate the safety and effectiveness of IG-IMRT for these patients. Methods: 10 metastatic lesions were treated with conventionally-fractionated IG-IMRT. Daily kilovoltage cone-beam computed tomography (kV-CBCT) scan was applied to ensure accurate positioning. Plans were evaluated by the dose-volume histogram (DVH) analysis. Results: Before set-up correction, the positioning errors in the left-right (LR), superior-inferior (SI) and anterior-posterior (AP) axes were 0.3 ± 3.2, 0.4 ± 4.5 and -0.2 ± 3.9 mm, respectively. After repositioning, those errors were 0.1 ± 0.7, 0 ± 0.8 and 0 ± 0.7 mm, respectively. The systematic/random uncertainties ranged 1.4–2.3/3.0–4.1 before and 0.1–0.2/0.7–0.8 mm after online set-up correction. In the original IMRT plans, the average dose of the planning target volume (PTV) was 61.9 Gy, with the spinal cord dose less than 49 Gy. Compared to the simulated PTVs based on the pre-correction CBCT, the average volume reduction of PTVs was 42.3% after online correction. Also, organ at risk (OAR) all benefited from CBCT-based set-up correction and had significant dose reduction with IGRT technique. Clinically, most patients had prompt pain relief within one month of treatment. There was no radiation-induced toxicity detected clinically during a median follow-up of 15.6 months. Conclusion: IG-IMRT provides a new approach to treat cancer spinal metastasis. The precise positioning ensures the implementation of optimal IMRT plan, satisfying both the dose escalation of tumor targets and the radiation tolerance of spinal cord. It might benefit the cancer patient with spinal metastasis.