Michael Kapinsky
Research Subjects
Michael Kapinsky has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Anders Handrup Kverneland
National Center of Cancer Immune Therapy, CCIT-DK, Department of Oncology, Copenhagen University Hospital, Herlev, Denmark
1 shared publication - Anis Larbi
Department of Medicine, Faculty of Medicine and Health Sciences, University of Sherbrooke
1 shared publication - Birgit Sawitzki
Preprint Club, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Berlin, Germany
1 shared publication - Christian Meisel
Department of Immunology, Labor Berlin Charité-Vivantes , Berlin
1 shared publication - Eda Holl
Beckman Coulter Life Sciences, Miami, FL 33196, USA
1 shared publication - Edward K. Geissler
University Hospital Regensburg, Department of Surgery, Regensburg, Germany
1 shared publication
Latest Publications
- Open Access
An Update on Flow Cytometry Analysis of Hematological Malignancies: Focus on Standardization
Flow cytometry use has significantly increased in clinical laboratories and has significantly helped improve the diagnosis of leukemias, lymphomas, and follow-up of minimal residual disease. Mastering this technique enables the performance of multiparametric single-cell analysis and increases the odds of identifying abnormal populations. As in many fields, there is a need to improve the quality of the data generated for accuracy, reproducibility, and trueness. The implementation of solutions reducing variability is achievable and needed, as the flow cytometry workflow involves many manual steps and items susceptible to operator bias and human error. Standardization of flow cytometry assays is sought and already implemented in many clinical hematology laboratories. However, the clinical community would highly benefit from further efforts in that direction to increase the comparability of findings across laboratories. This review covers the strengths and weaknesses of flow cytometry and focuses on the standardization approaches developed, including recent advances in the field.
Open AccessAn Update on Flow Cytometry Analysis of Hematological Malignancies: Focus on Standardization
Flow cytometry use has significantly increased in clinical laboratories and has significantly helped improve the diagnosis of leukemias, lymphomas, and follow-up of minimal residual disease. Mastering this technique enables the performance of multiparametric single-cell analysis and increases the odds of identifying abnormal populations. As in many fields, there is a need to improve the quality of the data generated for accuracy, reproducibility, and trueness. The implementation of solutions reducing variability is achievable and needed, as the flow cytometry workflow involves many manual steps and items susceptible to operator bias and human error. Standardization of flow cytometry assays is sought and already implemented in many clinical hematology laboratories. However, the clinical community would highly benefit from further efforts in that direction to increase the comparability of findings across laboratories. This review covers the strengths and weaknesses of flow cytometry and focuses on the standardization approaches developed, including recent advances in the field.
- Open Access
- 25 October 2013
- Published by Springer Nature in Transplantation Research
- Vol. 2 (1) , 17
Standardization of whole blood immune phenotype monitoring for clinical trials: panels and methods from the ONE study
Background: Immune monitoring by flow cytometry is a fast and highly informative way of studying the effects of novel therapeutics aimed at reducing transplant rejection or treating autoimmune diseases. The ONE Study consortium has recently initiated a series of clinical trials aimed at using different cell therapies to promote tolerance to renal allografts. To compare the effectiveness of different cell therapies, the consortium developed a robust immune monitoring strategy, including procedures for whole blood (WB) leukocyte subset profiling by flow cytometry. Methods: Six leukocyte profiling panels computing 7- to 9-surface marker antigens for monitoring the major leukocyte subsets as well as characteristics of T cell, B cell, and dendritic cell (DC) subsets were designed. The precision and variability of these panels were estimated. The assay was standardized within eight international laboratories using Flow-Set Pro beads for mean fluorescence intensity target definition and the flow cytometer setup procedure. Standardization was demonstrated by performing inter-site comparisons. Results: Optimized methods for sample collection, storage, preparation, and analysis were established, including protocols for gating target subsets. WB specimen age testing demonstrated that staining must be performed within 4 hours of sample collection to keep variability low, meaning less than or equal to 10% for the majority of defined leukocyte subsets. Inter-site comparisons between all participating centers testing shipped normal WB revealed good precision, with a variability of 0.05% to 30% between sites. Intra-assay analyses revealed a variability of 0.05% to 20% for the majority of subpopulations. This was dependent on the frequency of the particular subset, with smaller subsets showing higher variability. The intra-assay variability performance defined limits of quantitation (LoQ) for subsets, which will be the basis for assessing statistically significant differences achieved by the different cell therapies. Conclusions: Local performance and central analysis of the ONE Study flow cytometry panel yields acceptable variability in a standardized assay at multiple international sites. These panels and procedures with WB allow unmanipulated analysis of changes in absolute cell numbers of leukocyte subsets in single- or multicenter clinical trials. Accordingly, we propose the ONE Study panel may be adopted as a standardized method for monitoring patients in clinical trials enrolling transplant patients, particularly trials of novel tolerance promoting therapies, to facilitate fair and meaningful comparisons between trials.
- 25 October 2013
- Published by Springer Nature in Transplantation Research
- Vol. 2 (1) , 17
Open AccessStandardization of whole blood immune phenotype monitoring for clinical trials: panels and methods from the ONE study
Background: Immune monitoring by flow cytometry is a fast and highly informative way of studying the effects of novel therapeutics aimed at reducing transplant rejection or treating autoimmune diseases. The ONE Study consortium has recently initiated a series of clinical trials aimed at using different cell therapies to promote tolerance to renal allografts. To compare the effectiveness of different cell therapies, the consortium developed a robust immune monitoring strategy, including procedures for whole blood (WB) leukocyte subset profiling by flow cytometry. Methods: Six leukocyte profiling panels computing 7- to 9-surface marker antigens for monitoring the major leukocyte subsets as well as characteristics of T cell, B cell, and dendritic cell (DC) subsets were designed. The precision and variability of these panels were estimated. The assay was standardized within eight international laboratories using Flow-Set Pro beads for mean fluorescence intensity target definition and the flow cytometer setup procedure. Standardization was demonstrated by performing inter-site comparisons. Results: Optimized methods for sample collection, storage, preparation, and analysis were established, including protocols for gating target subsets. WB specimen age testing demonstrated that staining must be performed within 4 hours of sample collection to keep variability low, meaning less than or equal to 10% for the majority of defined leukocyte subsets. Inter-site comparisons between all participating centers testing shipped normal WB revealed good precision, with a variability of 0.05% to 30% between sites. Intra-assay analyses revealed a variability of 0.05% to 20% for the majority of subpopulations. This was dependent on the frequency of the particular subset, with smaller subsets showing higher variability. The intra-assay variability performance defined limits of quantitation (LoQ) for subsets, which will be the basis for assessing statistically significant differences achieved by the different cell therapies. Conclusions: Local performance and central analysis of the ONE Study flow cytometry panel yields acceptable variability in a standardized assay at multiple international sites. These panels and procedures with WB allow unmanipulated analysis of changes in absolute cell numbers of leukocyte subsets in single- or multicenter clinical trials. Accordingly, we propose the ONE Study panel may be adopted as a standardized method for monitoring patients in clinical trials enrolling transplant patients, particularly trials of novel tolerance promoting therapies, to facilitate fair and meaningful comparisons between trials.