Curtis P. Langlotz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Curtis P. Langlotz has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Paras Lakhani
Department of Radiology, Thomas Jefferson University Hospital, 132 S 10th St, Suite 796C, Philadelphia, PA 19107, USA
2 shared publications Alberto F. Goldszal
University of Pennsylvania
1 shared publicationElliot D. Menschik
Hx Technologies Inc
1 shared publicationJoseph P. Murray
Hx Technologies Inc
1 shared publicationMark G. Weiner
University of Pennsylvania
1 shared publicationParas Lakhani
Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
1 shared publication
Latest Publications
- 1 December 2012
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 265 (3) , 809-818
Automated Extraction of Critical Test Values and Communications from Unstructured Radiology Reports: An Analysis of 9.3 Million Reports from 1990 to 2011
To determine the frequency of critical radiology results in 9.3 million radiology reports from our health system, to identify those containing documentation of communication by using automated text-classification algorithms, and to assess the impact of a policy requiring documentation of critical results communication. This HIPAA-compliant retrospective study received institutional review board approval. Text-mining algorithms that were previously validated to have mean accuracies of more than 90% for identifying certain critical results and documentation of communications were applied to a database of 9.3 million radiology reports. The frequency of critical results and documentation of communication were then determined from 1990 to 2011. There was an increase in documentation of communication for all critical results from 1990 to 2011. In 1990, 19.0% of reports with critical values had evidence of documentation of communication compared with 72.4% of reports in 2010. The linear trend for increasing documentation of communications began in 1997 and continued until 2011 (P < .001). From 1990 to 2011, documentation of communication was highest in acute scrotal torsion (70.6%) and ectopic pregnancy (65.4%) and lowest in unexplained free-intraperitoneal air (29.5%) and malpositioned tubes (30.4%). In 2010-2011, radiologists were least likely to document communication of results for malpositioned endotracheal and enteric tubes (2010, 58.56%; 2011, 57.50%) and unexplained free-intraperitoneal air (2010, 59.57%; 2011, 75.51%). They were most likely to document communication of results for ectopic pregnancy (2010, 94.12%; 2011, 93.48%) and acute appendicitis (2010, 86.87%; 2011, 84.31%). There was an increase in documentation of communication of critical results, which demonstrated a rising linear trend that began in 1997 and continued until 2011. The increasing trend began well before policy implementation, indicating that other factors such as heightened awareness among radiologists likely had a role.
- 1 December 2012
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 265 (3) , 809-818
Automated Extraction of Critical Test Values and Communications from Unstructured Radiology Reports: An Analysis of 9.3 Million Reports from 1990 to 2011
To determine the frequency of critical radiology results in 9.3 million radiology reports from our health system, to identify those containing documentation of communication by using automated text-classification algorithms, and to assess the impact of a policy requiring documentation of critical results communication. This HIPAA-compliant retrospective study received institutional review board approval. Text-mining algorithms that were previously validated to have mean accuracies of more than 90% for identifying certain critical results and documentation of communications were applied to a database of 9.3 million radiology reports. The frequency of critical results and documentation of communication were then determined from 1990 to 2011. There was an increase in documentation of communication for all critical results from 1990 to 2011. In 1990, 19.0% of reports with critical values had evidence of documentation of communication compared with 72.4% of reports in 2010. The linear trend for increasing documentation of communications began in 1997 and continued until 2011 (P < .001). From 1990 to 2011, documentation of communication was highest in acute scrotal torsion (70.6%) and ectopic pregnancy (65.4%) and lowest in unexplained free-intraperitoneal air (29.5%) and malpositioned tubes (30.4%). In 2010-2011, radiologists were least likely to document communication of results for malpositioned endotracheal and enteric tubes (2010, 58.56%; 2011, 57.50%) and unexplained free-intraperitoneal air (2010, 59.57%; 2011, 75.51%). They were most likely to document communication of results for ectopic pregnancy (2010, 94.12%; 2011, 93.48%) and acute appendicitis (2010, 86.87%; 2011, 84.31%). There was an increase in documentation of communication of critical results, which demonstrated a rising linear trend that began in 1997 and continued until 2011. The increasing trend began well before policy implementation, indicating that other factors such as heightened awareness among radiologists likely had a role.
- 31 October 2010
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 7 (10) , 782-790
Documentation of Nonroutine Communications of Critical or Significant Radiology Results: A Multiyear Experience at a Tertiary Hospital
- 31 October 2010
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 7 (10) , 782-790
Documentation of Nonroutine Communications of Critical or Significant Radiology Results: A Multiyear Experience at a Tertiary Hospital
- 1 January 2006
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 19 (1) , 52-68
Development and Validation of Queries Using Structured Query Language (SQL) to Determine the Utilization of Comparison Imaging in Radiology Reports Stored on PACS
The purpose of this research was to develop queries that quantify the utilization of comparison imaging in free-text radiology reports. The queries searched for common phrases that indicate whether comparison imaging was utilized, not available, or not mentioned. The queries were iteratively refined and tested on random samples of 100 reports with human review as a reference standard until the precision and recall of the queries did not improve significantly between iterations. Then, query accuracy was assessed on a new random sample of 200 reports. Overall accuracy of the queries was 95.6%. The queries were then applied to a database of 1.8 million reports. Comparisons were made to prior images in 38.69% of the reports (693,955/1,793,754), were unavailable in 18.79% (337,028/1,793,754), and were not mentioned in 42.52% (762,771/1,793,754). The results show that queries of text reports can achieve greater than 95% accuracy in determining the utilization of prior images.
- 1 January 2006
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 19 (1) , 52-68
Development and Validation of Queries Using Structured Query Language (SQL) to Determine the Utilization of Comparison Imaging in Radiology Reports Stored on PACS
The purpose of this research was to develop queries that quantify the utilization of comparison imaging in free-text radiology reports. The queries searched for common phrases that indicate whether comparison imaging was utilized, not available, or not mentioned. The queries were iteratively refined and tested on random samples of 100 reports with human review as a reference standard until the precision and recall of the queries did not improve significantly between iterations. Then, query accuracy was assessed on a new random sample of 200 reports. Overall accuracy of the queries was 95.6%. The queries were then applied to a database of 1.8 million reports. Comparisons were made to prior images in 38.69% of the reports (693,955/1,793,754), were unavailable in 18.79% (337,028/1,793,754), and were not mentioned in 42.52% (762,771/1,793,754). The results show that queries of text reports can achieve greater than 95% accuracy in determining the utilization of prior images.