Pedro Henrique Reis da Silva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Pedro Henrique Reis da Silva has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Christian Fernandes
Universidade Federal de Minas Gerais
1 shared publication Gerson Antônio Pianetti
Federal University of Minas Gerais, Brazil
1 shared publication- Gerson Antônio Pianetti
Universidade Federal de Minas Gerais, Belo Horizonte
1 shared publication - Isabela Costa César
Departamento de Produtos Farmacêuticos, Faculdade de Farmácia, Universidade Federal de Minas Gerais
1 shared publication Paula Cristina Rezende Enéas
Oswaldo Cruz Foundation, Brazil
1 shared publication- Tiago A Miranda
Departamento de Produtos Farmacêuticos, Faculdade de Farmácia, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil
1 shared publication
Latest Publications
- Open Access
- 1 January 2017
- Published by FapUNIFESP (SciELO) in Brazilian Journal of Pharmaceutical Sciences
- Vol. 53 (2)
An innovative, simple, fast, and less toxic high-performance liquid chromatographic method for determination of prednisone in capsules
Prednisone is an anti-inflammatory steroid drug widely used in clinical practice. However, no high-performance liquid chromatographic (HPLC) method has been described in the literature for the determination of prednisone in capsules until now. Thus, an HPLC method was developed using a C18 (250x4.0, 5 µm) column, with methanol:water (70:30) as mobile phase at a flow rate of 1 mL/min and detection at 240 nm. The developed method was validated following current Brazilian legislation. Additionally, linearity was assessed by evaluating the assumptions of normality, homoscedasticity, and independency of residuals, and the fit to the linear model. The method showed linearity (r2>0.99) over the range of 14.0-26.0 µg/mL, selectivity, precision (RSD<2.0%), robustness, and accuracy (average recovery of 100.05%). The chromatographic procedure was applied for assay and uniformity content determination of three different batches of prednisone capsules, showing to be suitable for their quality control.
- 1 January 2017
- Published by FapUNIFESP (SciELO) in Brazilian Journal of Pharmaceutical Sciences
- Vol. 53 (2)
Open AccessAn innovative, simple, fast, and less toxic high-performance liquid chromatographic method for determination of prednisone in capsules
Prednisone is an anti-inflammatory steroid drug widely used in clinical practice. However, no high-performance liquid chromatographic (HPLC) method has been described in the literature for the determination of prednisone in capsules until now. Thus, an HPLC method was developed using a C18 (250x4.0, 5 µm) column, with methanol:water (70:30) as mobile phase at a flow rate of 1 mL/min and detection at 240 nm. The developed method was validated following current Brazilian legislation. Additionally, linearity was assessed by evaluating the assumptions of normality, homoscedasticity, and independency of residuals, and the fit to the linear model. The method showed linearity (r2>0.99) over the range of 14.0-26.0 µg/mL, selectivity, precision (RSD<2.0%), robustness, and accuracy (average recovery of 100.05%). The chromatographic procedure was applied for assay and uniformity content determination of three different batches of prednisone capsules, showing to be suitable for their quality control.
- Open Access
- 28 January 2015
- Published by Springer Nature in Malaria Journal
- Vol. 14 (1) , 29
Simultaneous quantitation of chloroquine and primaquine by UPLC-DAD and comparison with a HPLC-DAD method
Chloroquine and primaquine are the first-line treatment recommended by World Health Organization for malaria caused by Plasmodium vivax. Since the problem of counterfeit or substandard anti-malarials is well established all over the world, the development of rapid and reliable methods for quality control analysis of these drugs is essential. Thus, the aim of this study was to develop and validate a novel UPLC-DAD method for simultaneously quantifying chloroquine and primaquine in tablet formulations. The UPLC separation was carried out using a Hypersil C18 column (50 × 2.1 mm id; 1.9 μm particle size) and a mobile phase composed of acetonitrile (A) and 0.1% aqueous triethylamine, pH 3.0 adjusted with phosphoric acid (B), at a flow rate 0.6 mL/min. Gradient elution was employed. UV detection was performed at 260 nm. UPLC method was fully validated and the results were compared to a conventional HPLC-DAD method for the analysis of chloroquine and primaquine in tablet formulations. UPLC method was shown to be linear (r 2 > 0.99), precise (CV < 2.0%), accurate (recovery rates from 98.11 to 99.83%), specific, and robust. No significant differences were observed between the chloroquine and primaquine contents obtained by UPLC and HPLC methods. However, UPLC method promoted faster analyses, better chromatographic performance and lower solvent consumption. The developed UPLC method was shown to be a rapid and suitable technique to quantify chloroquine and primaquine in pharmaceutical preparations and may be successfully employed for quality control analysis.
- 28 January 2015
- Published by Springer Nature in Malaria Journal
- Vol. 14 (1) , 29
Open AccessSimultaneous quantitation of chloroquine and primaquine by UPLC-DAD and comparison with a HPLC-DAD method
Chloroquine and primaquine are the first-line treatment recommended by World Health Organization for malaria caused by Plasmodium vivax. Since the problem of counterfeit or substandard anti-malarials is well established all over the world, the development of rapid and reliable methods for quality control analysis of these drugs is essential. Thus, the aim of this study was to develop and validate a novel UPLC-DAD method for simultaneously quantifying chloroquine and primaquine in tablet formulations. The UPLC separation was carried out using a Hypersil C18 column (50 × 2.1 mm id; 1.9 μm particle size) and a mobile phase composed of acetonitrile (A) and 0.1% aqueous triethylamine, pH 3.0 adjusted with phosphoric acid (B), at a flow rate 0.6 mL/min. Gradient elution was employed. UV detection was performed at 260 nm. UPLC method was fully validated and the results were compared to a conventional HPLC-DAD method for the analysis of chloroquine and primaquine in tablet formulations. UPLC method was shown to be linear (r 2 > 0.99), precise (CV < 2.0%), accurate (recovery rates from 98.11 to 99.83%), specific, and robust. No significant differences were observed between the chloroquine and primaquine contents obtained by UPLC and HPLC methods. However, UPLC method promoted faster analyses, better chromatographic performance and lower solvent consumption. The developed UPLC method was shown to be a rapid and suitable technique to quantify chloroquine and primaquine in pharmaceutical preparations and may be successfully employed for quality control analysis.